• Title/Summary/Keyword: [BQ] method

Search Result 104, Processing Time 0.025 seconds

The Evaluation of Reconstruction Method Using Attenuation Correction Position Shifting in 3D PET/CT (PET/CT 3D 영상에서 감쇠보정 위치 변화 방법을 이용한 영상 재구성법의 평가)

  • Hong, Gun-Chul;Park, Sun-Myung;Jung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.172-176
    • /
    • 2010
  • Purpose: The patients' moves occurred at PET/CT scan will cause the decline of correctness in results by resulting in inconsistency of Attenuation Correction (AC) and effecting on quantitative evaluation. This study has evaluated the utility of reconstruction method using AC position changing method when having inconsistency of AC depending on the position change of emission scan after transmission scan in obtaining PET/CT 3D image. Materials and Methods: We created 1 mL syringe injection space up to ${\pm}2$, 6, 10 cm toward x and y axis based on central point of polystyrene ($20{\times}20110$ cm) into GE Discovery STE16 equipment. After projection of syringe with $^{18}F$-FDG 5 kBq/mL, made an emission by changing the position and obtained the image by using AC depending on the position change. Reconstruction method is an iteration reconstruction method and is applied two times of iteration and 20 of subset, and for every emission data, decay correction depending on time pass is applied. Also, after setting ROI to the position of syringe, compared %Difference (%D) at each position to radioactivity concentrations (kBq/mL) and central point. Results: Radioactivity concentrations of central point of emission scan is 2.30 kBq/mL and is indicated as 1.95, 1.82 and 1.75 kBq/mL, relatively for +x axis, as 2.07, 1.75 and 1.65 kBq/mL for -x axis, as 2.07, 1.87 and 1.90 kBq/mL for +y axis and as 2.17, 1.85 and 1.67 kBq/mL for -y axis. Also, %D is yield as 15, 20, 23% for +x axis, as 9, 23, 28% for -x axis, as 12, 21, 20% for +y axis and as 8, 22, 29% for -y axis. When using AC position changing method, it is indicated as 2.00, 1.95 and 1.80 kBq/mL, relatively for +x axis, as 2.25, 2.15 and 1.90 kBq/mL for -x axis, as 2.07, 1.90 and 1.90 kBq/mL for +y axis, and as 2.10, 2.02, and 1.72 kBq/mL for -y axis. Also, %D is yield as 13, 15, 21% for +x axis, as 2, 6, 17% for -x axis, as 9, 17, 17% for +y axis, and as 8, 12, 25% for -y axis. Conclusion: When in inconsistency of AC, radioactivity concentrations for using AC position changing method increased average of 0.14, 0.03 kBq/mL at x, y axis and %D was improved 6.1, 4.2%. Also, it is indicated that the more far from the central point and the further position from the central point under the features that spatial resolution is lowered, the higher in lowering of radioactivity concentrations. However, since in actual clinic, attenuation degree increases more, it is considered that when in inconsistency, such tolerance will be increased. Therefore, at the lesion of the part where AC is not inconsistent, the tolerance of radioactivity concentrations will be reduced by applying AC position changing method.

  • PDF

Performance Evaluation of Biofuel cell using Benzoquinone Entrapped Polyethyleneimine-Carbon nanotube supporter Based Enzymatic Catalyst (벤조퀴논 포집 폴리에틸렌이민-탄소나노튜브 지지체 기반 효소촉매의 바이오연료전지로서의 성능평가)

  • Ahn, Yeonjoo;Chung, Yongjin;Kwon, Yongchai
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.258-263
    • /
    • 2017
  • In this study, we synthesized biocatalyst consisting of glucose oxidase (GOx), polyethyleneimine (PEI) and carbon nanotube (CNT) with addition of p-benzoquinone (BQ) that was considered anodic catalysts of enzymatic biofuel cell (EBC). For doing this, PEI/CNT supporter was bonded with BQ by physical entrapping method stemmed from electrostatic attractive force ([BQ/PEI]/CNT). In turn, GOx moiety was further immobilized on the [BQ/PEI]/CNT to form GOx/[BQ/PEI]/CNT catalyst. This catalyst has a special advantage in that the BQ that has been usually dissolved into electrolyte was immobilized on supporter. According to the electrochemical analysis, maximum current density of the GOx/[BQ/PEI]/CNT catalyst was 1.9 fold better than that of the catalyst that did not entrap BQ with the value of $34.16{\mu}A/cm^2$, verifying that catalytic activity of the catalyst was enhanced by adoption of BQ. Also, when it was used as anodic catalyst of the EBC, its maximum power density was 1.2 fold better than that of EBC using the catalyst that did not entrap BQ with the value of $0.91mW/cm^2$. Based on such results, it turned out that the GOx/[BQ/PEI]/CNT catalyst was promising and viable as anodic catalyst of EBC.

Alternative Method for the Treatment of Chemical Wastes Containing Uranium (우라늄함유 화학폐수의 적정처리 기술)

  • Kim Kil-Jeong;Shon Jong-Sik;Hong Kwon-Pyo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.179-186
    • /
    • 2006
  • Chemical wastes are generated from nuclear facilities and R&D laboratories, but the uranium concentration in the final dried cake is evaluated into 11.2 Bq/g, which exceeds the exemption level of 10 Bq/g for each U isotopes, so the cake is categorized into a radioactive waste. Acid dissolution was applied to extract uranium from the waste sludge, and uranium adsorption on the dissolved solution was experimented by using IRN-77 and Diphosil bead. A large amount of resin was required to get above 80% of uranium removal, which was found to be due to a large amount of metal ions simultaneously dissolved from the precipitates with uranium. As an alternative method, acid dissolution is applied to the dewatered wet cake of the sludge, and the natural evaporation method is adopted for the dissolved solution. The uranium concentration of the dissolved solution was estimated to be 6.97E-01 Bq/ml, and the specific activity of the final waste sheets is evaluated to be 4.3 Bq/g. These results lead to the suggestion that the application of acid dissolution to the wet cake and the natural evaporation for the dissolved solution is an effective treatment method for chemical wastes containing uranium.

  • PDF

Bq-ZSI fed Induction Motor Drive System Using Modified Space Vector Modulation (변형 공간벡터 변조 기법이 적용된 Bq-ZSI를 이용한 유도전동기 구동시스템)

  • Han, Sang-Hyup;Kim, Heung-Geun;Cha, Honnyong;Chun, Tea-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.1
    • /
    • pp.9-15
    • /
    • 2018
  • This study investigates a bidirectional quasi-Z-source inverter (Bq-ZSI) system with bidirectional power transfer capability and a modified space vector modulation scheme for reducing the ripple of the inductor current. By replacing the diode in the impedance network with an active switch, the power flow can be bidirectional. The average inductor current of the Bq-ZSI network is negative in the regenerative braking mode, thereby regenerating the power. In addition, modified space vector modulation scheme is applied to the Bq-ZSI to control shoot-through time effectively. A 5 kW prototype is built and tested to implement the proposed system. Experimental results show that the Bq-ZSI system is capable of regenerative braking of the induction motor and that the modified space vector modulation method is efficient.

Absolute Activity Measurement of $^{137}Cs$ Solution by the Tracer Method (추적자 방법에 의한 $^{137}Cs$용액의 방사능 절대측정)

  • Park, Tae-Soon;Oh, Pil-Jae;Hwang, Sun-Tae;Lee, Kun-Jai
    • Nuclear Engineering and Technology
    • /
    • v.19 no.2
    • /
    • pp.107-114
    • /
    • 1987
  • Using a solution of $^{137}$ Cs as a tracer, radioactivity of a $^{137}$ Cs solution is measured by coincidence and anticoincidence counting methods. Sample sources in this study are fabricated by mixing $^{137}$ Cs with tracer, and the mixing ratios are 1/3 and 1/5, respectively in coincidence and anticoincidence methods. Specific activities of a $^{137}$ Cs solution are calculated by means of f-channel low energy threshold level variation and efficiency extrapolation. The results obtained by coincidence and anticoincidence counting methods are 552.78 kBq/g and 554.32kBq/g, respectively on the reference date and the combined uncertainties are 1.60kBq/g and 1.51kBq/g for each method. These two results show a good agreement within the uncertainty range.

  • PDF

Characteristics of airborne radon and thoron levels monitored in Seoul Subway stations and circulation lines (서울 일부 지하철 공기 중 라돈과 토론 발생 특성)

  • Kwak, Hyunseok;Kim, So-Yeon;Park, Jihoon;Choi, Sangjun;Park, Dong-Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.176-184
    • /
    • 2019
  • Objective: This study aims to characterize airborne radon and thoron levels ($Bq/m^3$) generated from working environments in three subway stations in Seoul. Method: A radon and thoron detector (EQF3220) was used to monitor real-time airborne radon and thoron levels ($Bq/m^3$) and their daughters ($Bq/m^3$) every two hours. They were monitored not only in the driver's cabin of seven circulation lines, but also three offices, platforms, and water pump reservoirs in the three stations. Results: The average levels of radon and thoron were $67.9Bq/m^3$ (range; $7.2-619.4Bq/m^3$) and $44.4Bq/m^3$ (range; $4.3-819.2Bq/m^3$), respectively. Notably, higher than legal airborne radon levels ($600Bq/m^3$) were frequently monitored in the driver's cabin of seven circulation lines. Airborne radon levels monitored in the platforms and administrative offices were found to be over $100Bq/m^3$. The average equilibrium factors (F) were 0.12 and 0.06, respectively. The percentages detected were found to be 84.9 for radon and 72.4 for thoron, respectively. Conclusions: Significant airborne radon and thoron levels were frequently found to be generated in subway facilities including water reservoirs, platforms and driver's cabins. Further study is necessary to thoroughly investigate airborne radon and thoron in all subway stations and to devise proper measures.

Evaluation of Radon Exposure During Highway Tunnel Construction by New Austrian Tunneling Method (NATM 공법에 의한 고속도로 터널 공사 중 라돈 노출 평가)

  • Ye-Ji Yu;Hyoung-Ryoul Kim;Mo-Yeol Kang;Sangjun Choi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.115-125
    • /
    • 2023
  • Objectives: This study was conducted to measure the level of radon in the air at a highway tunnel construction site in a gneiss area using the New Austrian Tunneling Method (NATM) and to evaluate exposure levels by occupation. Methods: Radon concentrations in the air were measured using E-PERM at points 300 m, 600 m, and 900 m from the tunnel entrance during the excavation and waterproofing work inside the tunnel. In addition, radon concentrations were measured during external excavation to compare with the inside of the tunnel. Personal exposure levels for major occupations including tunnel workers, construction equipment operators, waterproofers, shotcrete workers, and safety and health managers who participated in the construction were estimated using radon concentration measured in the work process area and working hours by occupation. Results: As a result of a total of 77 radon measurements, the geometric mean (GM) concentration was 71.1 Bq/m3, and the maximum concentration was 127.3 Bq/m3, which was below the indoor air quality criteria. Radon concentration by process decreased in the order of the tunnel excavation process (GM= Bq/m3, GSD=1.2), waterproofing process (GM=73.35 Bq/m3, GSD=1.2), and outside excavating process (GM=45.28 Bq/m3, GSD=1.2). Processes inside the tunnel were significantly higher than outside excavating processes (p<0.05). There was no statistically significant difference in radon concentration measured inside by distance from the tunnel entrance, but the innermost point of the tunnel, 900 m (GM=79.24 Bq/m3, GSD=1.27), measured the highest. Conclusions: The occupation with the highest individual exposure to radon was tunnel worker (64.16 Bq/m3), followed by construction equipment driver (64.04 Bq/m3) and waterproofer (63.13 Bq/m3).

Determination of $^{226}Ra$ Isotope in the Leachate around Phosphogypsum Stack Using Ethylenediaminetetraacetic Acid (EDTA) (Ethylenediaminetetraacetic acid (EDTA)를 이용한 인산석고 야적장 침출수 중의 $^{226}Ra$ 분석법 개발)

  • Kim, Geun-Ho;Kim, Yong-Jae;Chang, Byung-Uck
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.223-229
    • /
    • 2011
  • Ba is the most useful element to get the $Ba(Ra)SO_4$ precipitate. However, when the high concentrations of ions such as sulfate, calcium are existed in the leachate of phosphogypsum stack, it is difficult to get the $Ba(Ra)SO_4$ precipitate. Since this reason, the developed method for the Ba coprecipitate using EDTA was performed to determine the $^{226}Ra$ concentration in the high sulfate sample. The average concentration of $^{226}Ra$ in a leachate of phosphogypsum using this method was 0.102 $Bq{\cdot}kg^{-1}$ and the minimal detectable activity is 3.4 $mBq{\cdot}kg^{-1}$. The $mBq{\cdot}kg^{-1}$ method was 0.102 $Bq{\cdot}kg^{-1}$ and the minimal detectable activity is 3.4 $mBq{\cdot}kg^{-1}$. The $^{226}Ra$ stock solution and the CRM (Certified Reference Material) were analyzed to verify this method. In analyzed $^{226}Ra$ stock solution, bias with added concentration was approximately 1% and the correlation curve between $^{226}Ra$ concentration in simulated standard sample and measured $^{226}Ra$ concentration showed good agreement with a correlation coefficient ($R^2$) of 0.99. In analyzed CRM, maximum bias with reference value was 5.8% (k=1) and the analytical results were in good agreement with the reference value.

Distribution of Radon Concentration at Subway Station in Seoul (서울시 지하철역사의 라돈농도분포 조사)

  • Lee Cheol-Min;Kim Yoon-Shin;Kim Jong-Cheol;Jeon Hyung-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.469-480
    • /
    • 2004
  • The radon concentrations were measured to survey distribution of radon concentrations in Seoul subway stations. The radon concentrations in air and water were measured at seventeen subway stations(Mapo, Chungjongno, Sodaemun, Kwanghwamun, Chongno3ga, Ulchiro4ga, Tangdaemun, Sangildong on Line 5;Nowon, Chunggye, Hagye, Kongnung, Taenung, Mokkol, Chunghwa, Sangbong, Myomok on Line 7) using the $RAdtrak^{TM}$ radon gas detector, Pylon AB-5 continuous passive radon detector and liquid scintillation counting method from January to May 1999. The major results obtained from this study were as follows: The long-term mean concentrations of radon were $61.8\;Bq/m^3$ in office, $78.9\;Bq/m^3$ in platform, $38.2\;Bq/m^3$ in concourse and $20.1\;Bq/m^3$ in outdoor, respectively. These levels were less than the action level ($148\;Bq/m^3$) of the U.S. EPA. The highest level of short-term mean concentrations was $116.55\;Bq/m^3$ at Chongno3ga station on the 5th line subway stations, while the lowest mean concentration was $19.55\;Bq/m^3$ at Mokkol station on the 7th line subway stations. The highest concentration of radon in the road water and storing underground water in the subway stations was $234.7\;KBq/m^3\;and\;155.5\;KBq/m^3$ in Sodaemun subway station, respectively. The results suggest that radon concentration in subway stations seems to be affected by ventilation and radon concentratin in underground water in the subway stations.

Effective Doses Estimated According to Characteristics of Airborne Radon and Thoron Levels Generated from Some Household Products (일부 생활용품에서 발생한 공기 중 라돈과 토론의 발생 특성 및 연간 유효선량 추정)

  • Park, Dong-Uk;Yi, Seongjin;Kim, So-Yeon;Kwak, Hyunseok;Lee, Seunghee;Park, Jihoon
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.2
    • /
    • pp.99-112
    • /
    • 2019
  • Objective: This study aims to analyze the characteristics of airborne radon and thoron level ($Bq/m^3$) generated from household products containing monazites, and estimate the effective doses (mSv/yr). Method: Radon & Thoron detector EQF3220 was used to monitor real-time airborne radon and thoron level ($Bq/m^3$), and their daughters ($Bq/m^3$) were recorded every two hours. Effective doses (mSv/yr) for radon and thoron were estimated according to models developed by International Commission on Radiological Protection (ICRP) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Results: The average levels of radon and thoron were $87.8Bq/m^3$ (range; $20.8-156.3Bq/m^3$) and $1,347.5Bq/m^3$ (range; $4-5,839.7Bq/m^3$), respectively. The average equilibrium factors (F) were 0.23 and 0.007, respectively. The levels of radon progeny were far higher than that thoron. Latex mattress showed the highest F (0.38). The average effective doses were estimated to be ICRP (1.9 mSv/yr) and UNSCER (1.3 mSv/yr) for radon and UNSCEAR (1.6 mSv/yr) for thoron. Conclusions: Our results have far exceeded the allowable effective dose for general population (1 mSv/yr). The government's actions such as the ban of use of consumer products containing monazite and the establishment of surveillance system to evaluate health effects for the people affected should be taken as early as possible.