• Title/Summary/Keyword: [BQ]

Search Result 448, Processing Time 0.031 seconds

Radon Removal Efficiency of Activated Carbon Filter from Coconut (코코넛 기반 활성탄 필터의 라돈 제거 효율)

  • Yun-Jin Ahn;Gi-Sub Kim;Tae-Hwan Kim;Sang-Rok Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.141-149
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences plans to produce 225Ac, a therapeutic radio-pharmaceutical for precision oncology, such as prostate cancer. Radon, a radioactive gas, is generated by radium, the target material for producing 225Ac. The radon concentration is expected to be about 2000 Bq·m-3. High-concentration radon-generating facilities must meet radioactive isotope emission standards by lowering the radon concentration. However, most existing studies concerning radon removal using activated carbon filters measured radon levels at concentrations lower than 1000 Bq·m-3. This study measured 222Rn removal of coconut-based activated carbon filter under a high radon concentration of about 2000 Bq·m-3. The 222Rn removal efficiency of activated carbon impregnated with triethylenediamine was also measured. As a result, the 222Rn removal amount of the activated carbon filter showed sufficient removal efficiency in a 222Rn concentration environment of about 2000 Bq·m-3. In addition, despite an expectation of low radon reduction efficiency of Triethylenediamine-impregnated activated carbon, it was difficult to confirm a significant difference in the results. Therefore, it is considered that activated carbon can be used as a radioisotope exhaust filter regardless of whether or not Triethylenediamine is impregnated. The results of this study are expected to be used as primary data when building an air purification system for radiation safety management in facilities with radon concentrations of about 2000 Bq·m-3.

Activity concentrations and radiological hazard assessments of 226Ra, 232Th, 40K, and 137Cs in soil samples obtained from the Dongnam Institute of Radiological & Medical Science, Korea

  • Jieun Lee;HyoJin Kim;Yong Uk Kye; Dong Yeon Lee;Wol Soon Jo;Chang Geun Lee;Jeung Kee Kim;Jeong-Hwa Baek;Yeong-Rok Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2388-2394
    • /
    • 2023
  • The radioactivity concentration of environmental radionuclides was analyzed for soil and sand at eight locations within a radius of 255 m centered on the Dongnam Institute of Radiological & Medical Science (DIRAMS), Korea. The average activity concentrations of 40K, 137Cs, 226Ra, and 232Th were 661.1 Bq/kg-dry, 0.9 Bq/kg-dry, 21.9 Bq/kg-dry, and 11.1 Bq/kg-dry, respectively. The activity of 40K and 137Cs was lower than the 3-year (2017-2019) average reported by the Korea Institute of Nuclear Safety, respectively. Due to the nature of granite-rich soil, the radioactivity of 40K was 0.6-fold higher than in other countries, while 137Cs was in the normal fluctuation range (15-30 Bq/kg-dry) of the concentration of radioactive fallout from nuclear tests. The activity of 226Ra and 232Th was lower than in Korean soils reported by the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). The average activity concentrations of 232Th and 40K for the soil and sand samples from DIRAMS were within the range specified by UNSCEAR in 2000. The radium equivalent activity and internal and external hazard index values were below the recommended limits (1 mSv/y). These radionuclide concentration (226Ra, 232Th, 40K, and 137Cs) data can be used for regional environmental monitoring and ecological impact assessments of nuclear power plant accidents.

A study on evaluation of the image with washed-out artifact after applying scatter limitation correction algorithm in PET/CT exam (PET/CT 검사에서 냉소 인공물 발생 시 산란 제한 보정 알고리즘 적용에 따른 영상 평가)

  • Ko, Hyun-Soo;Ryu, Jae-kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Purpose In PET/CT exam, washed-out artifact could occur due to severe motion of the patient and high specific activity, it results in lowering not only qualitative reading but also quantitative analysis. Scatter limitation correction by GE is an algorism to correct washed-out artifact and recover the images in PET scan. The purpose of this study is to measure the threshold of specific activity which can recovers to original uptake values on the image shown with washed-out artifact from phantom experiment and to compare the quantitative analysis of the clinical patient's data before and after correction. Materials and Methods PET and CT images were acquired in having no misalignment(D0) and in 1, 2, 3, 4 cm distance of misalignment(D1, D2, D3, D4) respectively, with 20 steps of each specific activity from 20 to 20,000 kBq/ml on $^{68}Ge$ cylinder phantom. Also, we measured the distance of misalignment of foley catheter line between CT and PET images, the specific activity which makes washed-out artifact, $SUV_{mean}$ of muscle in artifact slice and $SUV_{max}$ of lesion in artifact slice and $SUV_{max}$ of the other lesion out of artifact slice before and after correction respectively from 34 patients who underwent $^{18}F-FDG$ Fusion Whole Body PET/CT exam. SPSS 21 was used to analyze the difference in the SUV between before and after scatter limitation correction by paired t-test. Results In phantom experiment, $SUV_{mean}$ of $^{68}Ge$ cylinder decreased as specific activity of $^{18}F$ increased. $SUV_{mean}$ more and more decreased as the distance of misalignment between CT and PET more increased. On the other hand, the effect of correction increased as the distance more increased. From phantom experiments, there was no washed-out artifact below 50 kBq/ml and $SUV_{mean}$ was same from origin. On D0 and D1, $SUV_{mean}$ recovered to origin(0.95) below 120 kBq/ml when applying scatter limitation correction. On D2 and D3, $SUV_{mean}$ recovered to origin below 100 kBq/ml. On D4, $SUV_{mean}$ recovered to origin below 80 kBq/ml. From 34 clinical patient's data, the average distance of misalignment was 2.02 cm and the average specific activity which makes washed-out artifact was 490.15 kBq/ml. The average $SUV_{mean}$ of muscles and the average $SUV_{max}$ of lesions in artifact slice before and after the correction show a significant difference according to a paired t-test respectively(t=-13.805, p=0.000)(t=-2.851, p=0.012), but the average $SUV_{max}$ of lesions out of artifact slice show a no significant difference (t=-1.173, p=0.250). Conclusion Scatter limitation correction algorism by GE PET/CT scanner helps to correct washed-out artifact from motion of a patient or high specific activity and to recover the PET images. When we read the image occurred with washed-out artifact by measuring the distance of misalignment between CT and PET image, specific activity after applying scatter limitation algorism, we can analyze the images more accurately without repeating scan.

Determination of $^{14}C$ in Environmental Samples Using $CO_2$ Absorption Method ($Co_2$ 흡수법에 의한 환경시료중 $^{14}C$ 정량)

  • Lee, Sang-Kuk;Kim, Chang-Kyu;Kim, Cheol-Su;Kim, Yong-Jae;Rho, Byung-Hwan,
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.1
    • /
    • pp.35-46
    • /
    • 1997
  • A simple and precise method of $^{14}C$ was developed to analyze $^{14}C$ in the environment samples using a commercially available $^{14}CO_2$ absorbent and a liquid scintillation counter. An air sampler and a combustion system were developed to collect HTO and $^{14}CO_2$ in the air and the biological samples simultaneously. The collection yield of $^{14}CO_2$ by the air sampler was in the range of 73-89% . The yield of the combustion system was 97%. In preparing samples for counting, the optimum ratio of $CO_2$ absorbent to the scintillator for mixing was 1:1. No variation of the specific activity of $^{14}C$ in the counting sample was observed up to 70 days after preparation of the samples. The detection limit for$^{14}C$ was 0.025 Bq/gC, which is the level applicable to the natural level of $^{14}C$. The analytical result of $^{14}C$ obtained by the present method were within ${\pm}6%$ of the relative error from the one by the benzene synthesis. The specific activity of $^{14}C$ in the air collected at Taejon during the period of October 1996 ranged from 0.26 to 0.27 Bq/gC. The specific activity of $^{14}C$ in the air collected at 1km from the Wolsong nuclear power plant a 679 MWe PHWR, was $0.54{\pm}0.03$ Bq/gC. The ranges of specific activities of $^{14}C$ in the pine needles and the vegetations from the areas around the Wolsong nuclear power plant were 0.56-0.67 Bq/gC and 0.23-1.41 Bq/gC, respectively.

  • PDF

Maximum Value Calculation of High Dose Radioiodine Therapy Room (고용량 방사성옥소 치료 병실의 최대치 산출)

  • Lee, Kyung-Jae;Cho, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.28-34
    • /
    • 2010
  • Purpose: According to increment of thyroid cancer recently, patients of high dose radioiodine therapy were accumulated. Taking into consideration the acceptance capability in the current facility, this study is to calculate the maximum value of high dose radioiodine therapy in patients for treatment. Materials and Methods: The amount and radioactivity of waste water discharged from high dose radioiodine therapy in patients admitted at present hospital as well as the radiation density of the air released into the atmosphere from the high dose radioiodine therapy ward were measured. When the calculated waste water's radiation and its density in the released air satisfies the standard (management standard for discharge into water supply 30 Bq/L, management standard for release into air 3 $Bq/m^3$) set by the Ministry of Education, Science and Technology, the maximum value of treatable high dose radioiodine therapy in patients was calculated. Results: When we calculated in a conservative view, the average density of radiation of waste water discharged from treating high dose radioiodine therapy one patient was 8 MBq/L and after 117 days of diminution in the water-purifier tank, it was 29.5 Bq/L. Also, the average density of radiation of waste water discharged from treating high dose radioiodine therapy two patients was 16 MBq/L and after 70 days of diminution in the water-purifier tank, it was 29.7 Bq/L. Under the same conditions, the density of radiation released into air through RI Ventilation Filter from the radioiodine therapy ward was 0.38 $Bq/m^3$. Conclusion: The maximum value of high dose radioiodine therapy in patients that can be treated within the acceptance capability was calculated and applied to the current facility, and if double rooms are managed by improving the ward structure, it would be possible to reduce the accumulated treatment waiting period for radioiodine therapy in patients.

  • PDF

Radioactivity concentrations of natural radionuclides in fine dust of Jeju, Korea

  • Chung-Hun Han;Sohyeon Lim;Hee-Jung Im
    • Analytical Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.191-197
    • /
    • 2023
  • Radioactivity concentrations for natural radionuclides were determined from fine dust samples collected in Jeju, Korea according to atmospheric events (Asian dust, haze, fog-mist, and non-event), and radium equivalent activity was calculated. The mean atmospheric radioactivity concentrations for 238U, 232Th, and 40K in 127 fine dust samples were 0.49, 0.24, and 7.23 µBq m-3, respectively, and the radium equivalent activity was 33.25 Bq kg-1. The mean concentrations of 238U and 232Th in the fine dust during the Asian dust period were 1.31 and 1.60 µBq m-3, respectively, above the global average, while the values for the other three atmospheric events were lower. The ratio of 232Th/238U radioactivity during the Asian dust period was 1.22, higher than the ratio for the other three atmospheric events.

Evaluation of Changes in Radon Levels in Educational Research Facilities by Number of Ventilation and Time (환기횟수 및 환기시간에 따른 교육연구시설 라돈 수치변화 평가)

  • Shin, Yoon-Seok;An, Jae-Seung;Kim, Seong-Bin;Park, Min-Young
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2023.11a
    • /
    • pp.335-336
    • /
    • 2023
  • 최근 환경에 대한 관심이 지속적으로 증가함에 따라 실내 공기질에 대한 관심 역시 증폭되었다. 이에 따라 실내 공기질을 결정 짓고 흡연에 이어 폐암 사망률이 높은 라돈에 대한 관심 역시 증가하였다. 따라서 본 연구에서는 실내 라돈가스의 농도를 낮추기 위한 방법을 찾기 위해 RADON EYE RD200을 이용하여 교육연구시설에서의 세 강의동을 대상으로 라돈 방출량을 측정하고, 환기를 통해 라돈의 감소량을 측정한다. 세 강의동 모두 현재 기준치인 148 Bq/m3을 초과하는 수치를 기록하였고, 강의실을 10분간 환기한 결과 1회 환기 시 평균 77 Bq/m3만큼 감소하였고, 2회 환기 시 평균 56 Bq/m3만큼 감소하였다. 본 연구를 통해 라돈의 실태 및 위험성을 인지하고 라돈에 관련된 시설물 지침 및 환기를 강조하는 방안에 대한 마련이 필요하다고 판단된다.

  • PDF

Natural Radioactivity of Soils by Bed Rocks Distributed in the Keum River Area (금강유역 기반암 토양의 자연방사능 특성)

  • Lee, Kil-Yong;Yoon, Yoon-Yeol;Cho, Soo-Young;Lee, Jung-Hwa;Lee, Jin-Soo;Koh, Kyung-Seok;Kim, Yong-Je
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.10-16
    • /
    • 2009
  • Characteristics of natural radioactivity were investigated for soils collected from seven sites of different bed rocks distributed in the Keum River area of Korea by the use of a Gamma-ray spectrometry. Specific activity (SA) and SA ratio (SAR) of typical naturally occurring radioactive nuclide such as $^{226}$Ra, $^{228}$Ac and $^{40}$K were determined for the soil samples. The SA values of $^{226}$Ra, $^{228}$Ac and $^{40}$K in 41 soils of 7 sites are 26.7-485 (74.2 ${\pm}$ 72.2), 30.9-157 (90.7 ${\pm}$ 32.7) and 203-1558 (990 ${\pm}$ 203) Bq/kg, respectively. The SA of $^{226}$Ra has very different values by the soils and the sites. Especially the SA of $^{226}$Ra in a soil sample of Ogcheon site is 485 Bq/kg while most SA of 41 soil samples are < 100 Bq/kg. SA of $^{228}$Ac has a little different values with the soils and sites, however the SA of $^{40}$K has almost constant values in all soil samples. The SAR values of $^{26}$Ra/$^{228}$Ac, $^{226}$Ra/$^{40}$K and $^{228}$Ac/$^{40}$K in 41 soils of 7 sites are 0.343-6.11 (0.865 ${\pm}$ 0.883), 0.0258-0.759 (0.0814 ${\pm}$ 0.1l17) and 0.0373-0.178 (0.0945 ${\pm}$ 0.0373), respectively. The SARs of $^{226}$Ra/$^{228}$Ac and $^{226}$Ra/$^{40}$K have very different values by the soils and the sites, however the SAR of $^{228}$Ac/$^{40}$K has a little difference by the soil and sites.

Monitoring on Radioactivity in Foodstuffs (식품에 대한 방사능 오염실태 조사)

  • Kwon, Ki-Sung;Hong, Jin-Hwan;Han, Sang-Bae;Lee, Eun-Ju;Kang, Kil-Jin;Chung, Hyung-Wook;Park, Seong-Gyu;Jang, Gui-Hyun;An, Ji-Seung;Kim, Dong-Sul;Kim, Myung-Chul;Kim, Chang-Min;Chung, Kun-Ho;Lee, Chang-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.183-187
    • /
    • 2004
  • Radioactivity in foodstuffs was surveyed for reference in amending regulation on the maximum permitted levels of radioactive contamination of foodstuffs. Most domestic and imported (?) foodstuffs were sampled, some domestic items collected around nuclear power plants to compare site-specific contamination. The collected samples were dried and ashed. Radioactivity in foodstuffs was measured using HPGe gamma spectrometer, Cs-137 activity ranged from 0.025-0.053, 0.045-0.500, 0.062-0.105, 0.025-1.151, 0.021-0.145 and 0.046-0.155 Bq/kg-fresh in cereals, pulses, mot vegetables (potato), ginsengs, meat, and marine products, respectively, with imported dried ginseng showing the highest radioactivity, Results reveal radioactivity in foodstuffs collected in 2002 is far below the maximum permitted levels of 370 Bq/kg. No significant differences were observed in radioactivity among sampling sites and between domestic and imported foodstuffs.

Correction of Artifacts due to Patient Arm Motion in PET/CT: Scatter-Limit Correction (PET/CT 검사에서 움직임에 의한 인공물의 산란제한보정법 적용 영상 평가)

  • Bahn, Young Kag;Lee, Seung Jae;Kim, Jung Yul;Oh, Sin Hyun;Nam-Koong, Hyuk;Park, Hoon-Hee;Kang, Chun Koo;Lim, Han Sang;Lee, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.44-48
    • /
    • 2012
  • Purpose : Arm motion can give rise to striking cold artifact on PET/CT. We investigated that evaluation of scatter-limit correction and correct the patient arm motion artifact in Discovery 600 PET/CT. Materials and Methods : To evaluate a radioactivity uptake (Bq/ml) and a standard uptake value (SUV), the scatter limit correction and scatter correction were compared using 1994 NEMA Phantom$^{TM}$ in Discovery 600 PET/CT (GE Healthcare, Mi, We). Arm motion phantom study was involved a central 20 cm diameter cylinder simulating the neck and 2 peripheral 10 cm diameter cylinders simulating arms. The positions of the arms were altered so as to introduce different amounts of misalignment. The evaluation of arm motion phantom study used the radioactivity uptake and SUV in scatter correction and scatter limit correction. Results : The statistical significance of radioactivity uptake and SUV did not show the differences in comparisons of the scatter limit correction and the scatter correction that not show (p<0.05). Radioactivity uptake of the scatter correction was up to 3.1 kBq/ml in the 0.04 kBq/ml. It was approximately 98.7% undervalued in the arm motion phantom study. However, Radioactivity uptake of the scatter limit correction was up to 3.0 kBq/ml in the 2.11 kBq/ml. It was approximately 30% undervalued in arm motion phantom study. SUV of the scatter correction was 1.05 to 0.006 and underestimated about 98%. However, an applying SUV of the scatter limit correction changed the value as 0.67 which is underestimated about 25%. Radioactivity uptake and SUV of the scatter limit correction was increased approximately 60%, or more than the scatter correction. Conclusion : It is considered that if the patient arm motion artifact was occurred the scatter limit correction will be applicable to give an accurate diagnosis.

  • PDF