• 제목/요약/키워드: (TEM)

검색결과 3,859건 처리시간 0.027초

Modified TEM Horn for Enhanced Radiation Characteristics at Low Frequency

  • Kim, Jae Sik;Park, Hyeong Soon;Yoon, Young Joong;Ryu, Jiheon;Choi, Jin Soo
    • Journal of electromagnetic engineering and science
    • /
    • 제14권2호
    • /
    • pp.74-78
    • /
    • 2014
  • This paper presents a modified TEM horn that improves radiation characteristics at a low frequency region. The proposed antenna consists of an asymmetric TEM (ATEM) horn and a loop structure with an elliptical shape. The bandwidth and gain at low frequency region can be enhanced by using the ATEM horn configuration and adding a loop structure with an elliptical shape to the ATEM horn. The bandwidth of the proposed antenna is from 2.14 to over 20 GHz, whereas that of the conventional TEM horn is from 2.7 to over 20 GHz, where the dimensions of both antennas are the same except for the thickness of the loop structure. The physical and electrical dimensions of the proposed antenna are $60mm{\times}62.5mm{\times}64mm$ ($width{\times}height{\times}length$) and $0.428{\lambda}_L{\times}0.445{\lambda}_L{\times}0.456{\lambda}_L$, where ${\lambda}_L$ corresponds to the lowest frequency of the bandwidth. The realized gain of the proposed antenna is improved by 0.802 dB on average at the low frequency region (2 to 8 GHz), where the maximum gain increase is 2.932 dB when compared to a conventional TEM horn.

TEM 도파관을 이용한 전자파 장해 측정 연구 및 표준화 동향

  • 권종화
    • 한국전자파학회지:전자파기술
    • /
    • 제13권1호
    • /
    • pp.51-62
    • /
    • 2002
  • EMI/EMS 측정을 위해서는 주변 전자파 잡음(background noise)이 낮은 야외시험장(Open Area Test Site)이 가장 바람직하나, 근래 전자(전기 기기 사용의 증가와 방송.무선통신 시스템의 다양화로 인한 인공잡음(artificial noise)의 증대로 조건에 부합된 부지 선정이 어렵고, 설치 비용이 매우 크며 날씨 변화에 따라 시험 계획이 변경 될 수도 있는 단점이 있다. 전자파 분-무반사실(Semi Anechoic Chamber)은 대부분의 환경 잡음을 감쇠시키므로 야외시험장처럼 장소의 구애를 받지 않아 도시나 혹은 제품 생산지 가까이에 설치 운용이 가능하다. 그러나 큰 설치 공간과 많은 시설 유지 비용을 필요로 하며, 저주파 대역에서는 반사에 의한 공진을 완전히 제거할 수 없어 성능이 떨어진다. 또한, 최근 컴퓨터 CPU의 동작주파수가 급속하게 높아지고 PCS, IMT-2000 등과 같은 이동전화의 사용주파수도 계속해서 높아짐에 다라 미연방통신위원회(Federal Communication Commission)에서는 5㎓까지의 복사 방출 시험을 요구하고 있다. IEC 61000-4-3 복사 내성 시험규격도 휴대폰 주파수인 2㎓까지 확장되었으며 IMT-2000, Bluetooth 등 새로운 이동통신서비스가 속속 개발됨에 따라 18㎓ 까지 시험 주파수가 확장되는 추세이다. 그러나, 현재 국내 각 연구실에서 보유하고 있는 야외시험장이나 전자파 반-무반사실의 경우 1㎓이상에서의 시험이 곤란하여 수 ㎓주파수대역에서 시험이 가능한 복사 및 내성시험 시설이 필요하게 되었다. 이러한 문제점들을 해결하기 위해 고안된 대용 측정 시설 중 대표적인 것이 TEM 셀이나 GTEM셀과 같은 TEM 도파관(waveguide) 형태의 장비들이다. 이들은 본래 EMS 측정을 위한 장비이지만 협소한 공간이나 외부와의 전자파 간섭의 우려가 없고, 설치가 비교적 자유로워 여러 연구기관에서 도파관 원리를 이용한 측정 방식을 연구(개발하여 범용적인 전자파 적합성 측정 장비로서 활용하고 있다. 야외시험장과 무반사실 등이 안테나에 의한 피시험기기 주변 공간에서의 1점 측정으로 인해 시험 시간이 많아 소요되는 공통적인 단점이 있는 반면, TEM 도파관에 의한 측정은 일단 피시험기기의 모델링 정보만 얻어지면 계산에 의해 EMI 측정을 바로 할 수 있다. <표 1>에서 현재 상용화되어 사용되고 있는 TEM/GTEM 셀, 야외 시험장 및 전자파 무반사실에 대해 EMI 측정과 관련된 몇 가지 사안에 대해 비교하였다. 본 문서에서는 야외시험장이나 전자파 반-무반사실 등과 같은 기존 EMI/EMS 측정 시설의 단점을 보완하고, 광대역 특성을 갖는 대용 측정 시설로서의 TEM 도파관에 대해 소개하고 야외시험장 결과와의 상관관계 알고리즘 및 표준화 동향에 대해 기술하였다. 2절에서는 대표적인 TEM 도파관 구조의 측정 시설인 TEM 셀과 GTEM 셀의 전기적.구조적 특징에 대해 간단히 기술하고, 3절에서는 TEM 셀과 GTEM 셀에서이 측정결과를 이용하여 야외 시험장 결과를 얻어내는 상관관계 알고리즘에 대해 기술하였다. 4절에서는 IEC/CISPR와 TC77에서의 표준화 활동을 중심으로 현재 진행중인 TEM 도파관 관련 표준화 동향과 내용에 대해 기술하고자 한다.

휴대폰 전자파의 혈액 조사를 위한 SAR별 TEM 셀의 입력 전력 산출 (Input Power Determination of TEM Cell Due to SAR for Mobile Phone Wave Blood Exposure)

  • 윤지훈;손태호
    • 한국전자파학회논문지
    • /
    • 제16권8호
    • /
    • pp.810-814
    • /
    • 2005
  • TEM 셀 내에 있는 혈액에 대한 삽입 손실과 반사율을 측정하여, 원하는 혈액 흡수 SAR(Specific Absorption Rate) 선택에 따른 TEM셀 입력 전력을 구하였다. 혈액 세포는 피부 세포와 함께 전자파 영향을 연구하기 위한 기준 세포이다. 따라서 SAR에 따른 혈액 세포에 인가할 전력 산출은 정확해야 함은 물론 타당성이 있어야 한다. 이 연구에서는 g당 혈액 세포가 받는 전력을 산출하기 위해 50 g의 혈액을 이용하여 전달 전력 감소를 측정하였다. 측정된 데이터로부터 휴대폰 전자파 생체 흡수율 SAR 0.8, 1.6, 3, 4 mW/g에 해당하는 TEM셀 입력 전력을 계산하였다. 이 연구 결과는 배양 세포의 전자파 방사 장치에 응용함을 목적으로 하고 있다.

열화학증기증착법을 이용한 그래핀의 합성 및 투과전자현미경 관찰용 그리드 멤브레인으로의 응용 (Synthesis of Graphene Using Thermal Chemical Vapor Deposition and Application as a Grid Membrane for Transmission Electron Microscope Observation)

  • 이병주;정구환
    • 한국재료학회지
    • /
    • 제22권3호
    • /
    • pp.130-135
    • /
    • 2012
  • We present a method of graphene synthesis with high thickness uniformity using the thermal chemical vapor deposition (TCVD) technique; we demonstrate its application to a grid supporting membrane using transmission electron microscope (TEM) observation, particularly for nanomaterials that have smaller dimensions than the pitch of commercial grid mesh. Graphene was synthesized on electron-beam-evaporated Ni catalytic thin films. Methane and hydrogen gases were used as carbon feedstock and dilution gas, respectively. The effects of synthesis temperature and flow rate of feedstock on graphene structures have been investigated. The most effective condition for large area growth synthesis and high thickness uniformity was found to be $1000^{\circ}C$ and 5 sccm of methane. Among the various applications of the synthesized graphenes, their use as a supporting membrane of a TEM grid has been demonstrated; such a grid is useful for high resolution TEM imaging of nanoscale materials because it preserves the same focal plane over the whole grid mesh. After the graphene synthesis, we were able successfully to transfer the graphenes from the Ni substrates to the TEM grid without a polymeric mediator, so that we were able to preserve the clean surface of the as-synthesized graphene. Then, a drop of carbon nanotube (CNT) suspension was deposited onto the graphene-covered TEM grid. Finally, we performed high resolution TEM observation and obtained clear image of the carbon nanotubes, which were deposited on the graphene supporting membrane.

Micro-TEM Cell을 사용한 표준 전자기장의 발생 및 측정불확도 평가 (Standard Field Generation Using a Micro-TEM Cell and Its Measurement Uncertainty Evaluation)

  • 강진섭;김정환;강웅택;강노원;강태원
    • 한국전자파학회논문지
    • /
    • 제20권1호
    • /
    • pp.91-99
    • /
    • 2009
  • 본 논문에서는 micro-TEM cell을 사용한 표준 전자기장 발생법을 기술하고 측정불확도를 평가하였다. 표준 전자기장 발생 시스템은 auto-leveling 기능을 가진 신호발생부, 최대 1.2 GHz까지 동작하는 micro-TEM cell, 서미스터 마운트를 사용한 전력측정부로 구성된다. 표준 전자기장 발생법의 타당성을 보이기 위해 $10\;MHz{\sim}1\;GHz$ 대역에서 전자기장의 세기 20 V/m에 대해 실시된 전자기장의 세기 국제비교(CCEM.RF-K20)의 참여 결과를 제시하였다.

분말 시료의 투과전자현미경 직접 가열 실험법 연구 (An Investigation of In Situ TEM Heating Experiments of Powder Samples)

  • 김윤중;정종만;이영부;이수정;송지호
    • Applied Microscopy
    • /
    • 제31권4호
    • /
    • pp.315-323
    • /
    • 2001
  • Kaolinite분말 시료를 이용한 TEM 직접 가열 실험에서 얻은 결론은 아래와 같다. (1) Gatan사의 가열 시료지지대에서 사용하고 있는 증류수 순환장치는 $500^{\circ}C$이상의 가열 실험에서 시료의 유동을 막는 필수적인 장비이다. (2) $600^{\circ}C$이하의 가열 실험에서는 분말의 두께에 따른 상전이 진행정도의 차이가 나타나기 때문에 앙은 시편과 두꺼운 시편을 고루 관찰하는 노력이 필요하다. (3) $900^{\circ}C$ 이상의 고온 가열 실험에서는 융점이 높은 Mo-grid의 사용이 필수적이다. 전체적으로 온도 상승률이나 온도 지속 시간이 상전이 과정에 미치는 영향이 증가하기 때문에 이들의 정량적인 제어가 가능한 자동제어방식의 사용이 필요하다. (4) 단면 관찰을 위해 고온용 epoxy에 포매된 kaolinite분말의 TEM가열 실험은 고온 가열시 epoxy의 유동 문제를 극복할 새로운 방법의 개발이 필요하다.

  • PDF

원심분리기를 이용한 분말시료의 TEM용 시편 준비법 연구 (An Investigation of TEM Specimen Preparation Methods from Powders Using a Centrifuge)

  • 정종만;이영부;김윤중
    • Applied Microscopy
    • /
    • 제29권1호
    • /
    • pp.67-73
    • /
    • 1999
  • 분말시료를 epoxy로 포매 (embedding)한 후 ion milling하는 방법으로 TEM 시편을 준비하는 경우에는 시료와 epoxy와의 milling정도의 차이 때문에 좋은 시편을 만들기 어렵다. 이러한 문제점을 극복하기 위해서 포매 물질에 대한 분말시료의 상대 밀도를 높여 주는 방법을 시도하였다. 일반적인 진공법보다는 원심분리기법을 이용하여 포매하는 것이 시료의 밀도를 높일 수 있었다. 또한, 비슷한 크기의 분말의 혼합보다는 서로 다른 크기의 분말을 혼합한 후 원심분리기를 이용하여 포매할 때, 큰 입자들 사이로 작은 입자들이 유입되면서 분말의 밀도가 더욱 높아지는 것을 알 수 있었다. 이렇게 준비된 시료는 ion milling정도의 차이에서 오는 문제점을 크게 줄일 수가 있어 TEM 관찰에 필요한 시편을 얻을 수 있었다. 원심분리기법은 마이크로미터 이하 크기의 구형, 판상 및 침상의 분말시료에서부터 TEM 시편을 준비하는 데에도 매우 효과적임이 드러났다.

  • PDF