• Title/Summary/Keyword: (L,M)-filters

Search Result 75, Processing Time 0.026 seconds

Kaolin Separation Characteristics of the Disc Filters (디스크 필터의 카올린 분리특성)

  • Park, Hye Jung;Kim, Dae Chun;Kim, Hyung Sung;Chung, Kun Yong
    • Membrane Journal
    • /
    • v.24 no.5
    • /
    • pp.393-399
    • /
    • 2014
  • The permeation experiments were carried out to examine the separation characteristics of the modules which were piled up the disc-ring shape patterned membranes in this study. First of all, permeability of the pure water was measured for the self-made 5 shape disc filters, and varied from 0.25 to $2.24L/m^2{\cdot}hr{\cdot}bar$. The module showed the maximum pure water permeability was the maximum permeation flux, and the module showed the minimum pure water permeability was the minimum permeation flux for 0.1 wt% kaolin solution. However, all of the modules were not proportioned to the pure water permeability. Also, the backwashing was performed periodically for the module 1 in order to operate with 0.1 wt% kaolin solution for a long time. The most efficient operating condition was the 8 minute permeation and 2 minute backwashing cycle.

Development of Biological Filtration Process for Effective Nitrogen Removal in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거법의 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.222-229
    • /
    • 2006
  • The treatment performance and operational parameters of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. In Filter 2, denitrification was accomplished under LV of 50~168 m/d in a 1 m filter-bed. However, the denitrification capacity reached the maximum when the linear velocity was increased to 202 m/d. Relationship between increase in microorganism and headloss was clearer in Filter 2. As a result, the denitrification rate increased from 1.0~2.3 kgN/($m^3-filter-bed{\cdot}d$) as the headloss increased. The COD removal rate was 6.0~9.6 kgCOD/($m^3-filter-bed{\cdot}d$) when operated with Filters 1 and 2. These results mean that captured bacteria contributed a part of COD consumption and denitrification. The maximum nitrification and denitrification rate was 0.5 and 4 kgN/($m^3-filter-bed{\cdot}d$) in Filter 1 and 2.The ratio of backwashing water to the treated water was about 5~10 %. In Filter 1, wasted sludge in backwashing was only 0.7~5.3 gSS/($m^3$-treated water). In Filter 2, added methanol was converted into sludge and its value was 8.0~24 gSS/($m^3$-treated water). These results proved that this process is both convenient to install as tertiary treatment and cost effective to build and operate.

Evaluation of the biocidal effects of activated carbon filter supporting silver

  • Moon, Kyong-Whan;Kim, Young-Whan;Choi, Dal-Woong
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2004.06a
    • /
    • pp.202-206
    • /
    • 2004
  • The objectives of this study are to investigate the relationship between the silver ion concentrations released from the point-of-use(POU) water purification devices installed silver impregnated activated carbon filters and the antibacterial activities against HPC bacteria. Total of 68 POU devices were tested. The concentrations of the eluted silver ion from the silver impregnated activated carbon filter showed the range from $4\;{\mu}g/L$ to $386\;{\mu}g/L$, and the HPC bacteria were found to diversely grow within the range 0-5,200 cfu/mL. The average silver concentrations released from UF units system and RO units system were $30\;{\mu}g/L$ and $73\;{\mu}g/L$, respectively. And the number of colonies were reduced significantly as the elution levels of silver exceeded $100\;{\mu}g/L$, however silver ions below the concentration of $100\;{\mu}g/L$ were not particularly effective for eradicating HPC bacteria from water.

  • PDF

Reuse Possibility of By-pass Flow and Secondary Effluent using BAF (BAF를 이용한 2차 처리수의 재이용 가능성 및 강우시 하수처리장 월류수의 처리)

  • An, J.H.;Park, J.B.;Kim, S.W.;Park, J.H.;Ha, J.S.;Choi, E.
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.2
    • /
    • pp.190-195
    • /
    • 2005
  • The laboratory and pilot scale BAFs (biological aerated filters) were operated with 0.3 hr to 1.1 hr EBCT(empty bed contact time) at a maximum filtration rate of $472m^3/m^2/day$ as a treatment method for reuse of secondary effluent and by-pass flow in this study. The effluent BOD and SS were generally 3.5 to 5 mg/L and 2 to 3 mg/L, respectively with 2ndary effluent, but the SS concentrations increased to 4 to 8 mg/L with the increased flow rates of by-pass flow. Potential nitrification rates were very high, but the nitrogen removal efficiencies were low due to the limited carbon sources. Bypass of a part of primary effluent seemed to be desirable to increase the nitrogen removal. Disinfection must be furnished for the reuse of BAF effluent.

Characteristics of ZnO thin film for surface acoustic filters (표면탄성파 필터를 위한 ZnO 박막의 특성)

  • Kim, Young-Jin;Park, Wuk-Dong;Kim, Ki-Wan
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.45-50
    • /
    • 1995
  • The excellent c-axis oriented zinc oxide thin films were prepared by the RF magnetron sputtering method on glass substrates. Optimum fabrication conditions of the ZnO films were such that RF power, substrate temperature, and gas pressure of mixture Ar(50%):$O_{2}$(50%) were 150 W, $200^{\circ}C$, and 5 mTorr, respectively. In these conditions, the deposition rate was $310\;{\AA}/min$, and the resistivity of the film was $1{\times}10^6\;{\Omega}{\cdot}cm$. The ZnO film also showed high c-axis orientation and crystalinity according to XRD pattern and SEM photograph. A fabricated interdigital transducer generated 1st mode surface acoustic wave at 46.6 MHz and 2nd mode surface acoustic wave at 52.5 MHz. At the 1st mode, the phase velocity of surface acoustic wave and the electromechanical coupling coefficient were 2795 m/sec and 0.031 %, respectivly. At the 2nd mode, they were 3149 m/sec and 0.019 %. respectivly.

  • PDF

DIRECT ESTIMATION OF PHYSICAL PARAMETERS OF AN RLC ELECTRICAL CIRCUIT BY SIXTEEN CONTINUOUS-TIME METHODS

  • Mensler, M.;Wada, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.526-526
    • /
    • 2000
  • The present has a double objective. The first one is to compare and estimate sixteen continuous-time methods through the identificatiun of a system consisted with an RLC electrical circuit. These sixteen methods are classified into three groups that are the linear filters, the modulating functions and the integral methods. The second objective is to estimate directly the physical parameters of the RLC circuit, without resorting to a discrete-time model. The system is consisted of a coil with inductance L and resistance H, and of a capacitor with capacitance C. Having written the physical equations which describe the behavior of the system, the transfer function in where the initial conditions appear is given. These initial conditions should be taken into account during the parameter estimation phase, because they are inevitable within the framework of real signals. A physical interpretation of the identified models is tempted by the direct estimation of the physical parameters L and C. In conclusion, a classification of the studied methods is proposed.

  • PDF

Effects of an Angle Droop Controller on the Performance of Distributed Generation Units with Load Uncertainty and Nonlinearity

  • Niya, M.S. Koupaei;Kargar, Abbas;Derakhshandeh, S.Y.
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.551-560
    • /
    • 2017
  • The present study proposes an angle droop controller for converter interfaced (dispatchable) distributed generation (DG) resources in the islanded mode of operation. Due to the necessity of proper real and reactive power sharing between different types of resources in microgrids and the ability of systems to respond properly to abnormal conditions (sudden load changes, load uncertainty, load current disturbances, transient conditions, etc.), it is necessary to produce appropriate references for all of the mentioned above conditions. The proposed control strategy utilizes a current controller in addition to an angle droop controller in the discrete time domain to generate appropriate responses under transient conditions. Furthermore, to reduce the harmonics caused by switching at converters' output, a LCL filter is used. In addition, a comparison is done on the effects that LCL filters and L filters have on the performance of DG units. The performance of the proposed control strategy is demonstrated for multi islanded grids with various types of loads and conditions through simulation studies in the DigSilent Power Factory software environment.

Reducing Methods of Patient's Exposed Dose Using Auto Exposure Control System in Digital Radiography (디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안)

  • Shin, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.36 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • This study was carried out to reduce patient dose through focus-detector distance, kilovoltage, and a combination of copper filters. In the C, L-spine lateral, Skull AP views were obtained by making changes of 60-100 kV in tube voltage and of 100-200 cm in focus-detector distance and by adding a copper filter when using an auto exposure control device in the digital radiography equipment. The incident dose showed 90 kV, 0.3 mmCu in C-spine lateral with 0.06 mGy under the condition of 200 cm; 100 kV, 0.3 mmCu with 0.40 mGy under the condition of 200 cm and 90 kV 0.3 mmCu in Skull AP with the lowest value of 0.24 mGy under the condition of 140 cm. It was observed that entrance surface dose decreased the most when was increased by 150 cm, 70 kV (C-spine lateral), 81 kV (L-spine lateral). It was also found out that as the between the focus-detector increased in the expansion of the video decreased but the difference was not significant when the distance was 180 cm or more. Skull AP showed the most reduction in the entrance surface dose when the tube voltage was changed by 80 kV, 0.1 mmCu, and 120 cm. Therefore, when using the automatic exposure control device, it is recommended to use the highest tube voltage if possible and to increase focus-detector distance at least by 150~200 cm in wall and 120~140 cm in table in consideration of the radiotechnologist's physical conditions, and to combine 0.1~0.3 mmCu and higher filters. It is thus expected to reduce patient dose by avoiding distortion of images and reducing the entrance surface dose.

PHOTOMETRIC PROPERTIES OF FOUR NEW VARIABLE STARS IN THE VICINITY OF BR CAM

  • KIM S.-L.;LEE C.-D.;LEE J. W.;LEE J. A.;KANG Y.B.;KOO J.-R.;VAUCLAIR G.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.143-149
    • /
    • 2004
  • We present photometric results for four new variable stars discovered in the vicinity of the ZZ Ceti-type pulsating white dwarf BR Cam. Observations were performed on 5 nights in November 2003 using the 1.8m telescope at Bohyunsan Optical Astronomy Observatory with no filter, on 3 nights in December 2003 using the 0.61m telescope at Sobaeksan Optical Astronomy Observatory with V, I filters, and on 3 nights in October 2004 using the 1.0m telescope at Mt. Lemmon Optical Astronomy Observatory with V, I filters. We estimated their periods from the phase-match technique for one eclipsing binary and the multiple frequency analysis for three pulsating stars. By considering the light curve shape, period and amplitude difference between two passbands, we classified the objects by their variability types as follows: V1 (USNO-A2.0 1425-05691757) is a W UMa-type eclipsing binary with an orbital period of $0^d.4641$; V2 (USNO-A2.0 1425-05703335) is a multi-periodic $\delta$ Set-type pulsating star with a dominant period of $0^d.0649$; V3 (USNO-A2.0 1425-05699659) is also a $\delta$ Set-type pulsating star with a period of $0^d.1408$; and V 4 (USNO-A2.0 1425-05707705) is a RR Lyr-type pulsating star with a period of $0^d.2643$.

PIV Measurements of the Pressure Driven Flow Inside a T-Shaped Microchannel Junction (T헝 마이크로채널 연결부 압력구동 유동의 PIV계측)

  • Choi Jayho;Lee In-Seop
    • Journal of the Korean Society of Visualization
    • /
    • v.1 no.1
    • /
    • pp.75-81
    • /
    • 2003
  • A custom micro-PIV optics assembly has been used to measure the flow fold inside a T-junction of a microchannel. The micro-PIV system consists of microscope objectives of various magnifications, a dichroic cube, and an 8-bit CCD camera. Fluorescent particles of diameters 620 nm have been used with a Nd:YAG laser and color filters. A programmable syringe pump with Teflon tubings were used to inject particle-seeded distilled water into the channel at flow rates of 2.0, 4.0, 6.0 mL/hr. The micro-channels are fabricated with PDMS with a silicon mold, then O$_{2}$ -ion bonded onto a slide glass. Results show differences in flow characteristics and resolution according to fluid injection rates, and magnifications, respectively. The results include PIV data with vector-to-vector distances of 2 $\mu$m with 32 pixel-square interrogation windows at 50$\%$ overlap.

  • PDF