• Title/Summary/Keyword: (칩유동)

Search Result 48, Processing Time 0.035 seconds

Design Analysis in a Cavity with Leadframe during Semiconductor Chip Encapsulation (반도체 칩 캡슐화(encapsulation)를 위한 트랜스퍼 금형 캐비티(cavity)에서의 설계 해석 및 실험에 관한 연구)

  • Han, Sejin;Huh, Yong-Jeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.12
    • /
    • pp.91-99
    • /
    • 1995
  • An effort has been made to more accurately analyze the flow in the chip cavity, particularly to model the flow through the openings in the leadframe and correctly treat the thermal boundary condition at the leadframe. The theoretical analysis of the flow has been done by using the Hele- Shaw approximation in each cavity separated by a leadframe. The cross-flow through the openings in the leadframe has been incorporated into the Hele-Shaw formulation as a mass source term. The temperature of the leadframe has been calculated based on energy balance in the leadframe. The flow behavior in the leadframe has been verified experimentally. In the experiment, a transparent mold and clear fluid have been used for flow visualization. Comparisons were made between the calculation and experimental results which showed a good agreement.

  • PDF

A Study on the Finite Element Analysis of Chip Formation in Machining (절삭가공시 집형성의 유한요소 해석에 관한 연구)

  • 김남용;박종권;이동주
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.973-976
    • /
    • 1997
  • Process behavior in metal cutting results from the chip formation process which is not easily observable and measurable during machining. By means of the finite element method chip formation in orthogonal metal cutting is modeled. The reciprocal interaction between mechanical and thermal loads is taken into consideration by involving the thermo-viscoplastic flow behavior of workpiece material. Local and temporal distributions of stress and temperature in the cutting zone are calculated depending on the cutting parameters. The calculated cutting forces and temperatures are compared with the experimental results obtarned from orthogonal cutting of steel AISl 4140. The model can be applied in process design for selection of appropriate tool-workpiece combination and optimum cutting conditions in term of mechanical and thermal loads.

  • PDF

Production of alginate hollow tube by diffusion of hydrogen ions at oil-prepolymer interface using a microfluidic chip (Oil-prepolymer 계면에서의 수소이온 확산을 통한 마이크로 플루이딕 칩 기반의 alginate hollow tube 제조)

  • Lee, Jae-Seon;Tran, Buu Minh;Nguyen, Phuoc Ouang Huy;Lee, Nae-Yun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.109-109
    • /
    • 2017
  • 알지네이트 하이드로 젤은 해조류에서 추출되는 천연 고분자인 알지네이트가 칼슘 또는 마그네슘 양이온과 이온가교(Ioninc cross linking)를 형성할 때 알지네이트의 고분자 구조가 칼슘, 마그네슘 양이온을 감싸면서 형성되는 고분자이다. 알지네이트 하이드로 젤은 높은 생체적합성(Biocompatibility)으로 인해 세포 재생을 위한 조직공학 및 재생의학, 약물전달 등의 제약 관련 분야에 광범위하게 적용될 수 있는 물질로 많은 연구가 이루어지고 있다. 본 연구에서는 마이크로 플루이딕 칩을 이용하여 알지네이트 튜브를 제조하였다. 먼저 유동 포커싱 방식(flow focussing)을 유도할 수 있는 PDMS(Polydimethylsiloxane) 마이크로 플루이딕 칩을 제조하였다. 마이크로 플루이딕 칩은 CNC(Computer Numeric Control) milling machine을 이용한 template를 만들고 NOA mold를 이용하여 최종 PDMS 칩을 제작하였다. 튜브를 만들기 위한 마이크로 채널은 내부 채널 ($200{\times}200um$), 중간 채널 ($200{\times}200um$) 및 외부 채널 ($200{\times}200um$)로 구성되며 내부, 중간, 외부의 유체가 합류하는 수집채널은 폭 500 um, 깊이 200 um로 구성되었다. 운반체로는 5%의 acetic acid를 함유한 mineral oil를 이용하였으며 내부의 core flow는 $H_2O$로 하였다. 중간 유체인 2% 알지네이트 프리폴리머는 칼슘 이온의 존재 하에서 젤화 과정이 매우 빠르기 때문에 마이크로 채널 내부에서의 반응을 제어하고 막힘을 방지하기 위해 수용성 복합 칼슘-에틸렌 디아민 테트라 아세트산 (EDTA)을 사용하였다. 본 마이크로 플루이딕 칩에 각각의 유체를 이동시켰을 때, 운반체인 oil phase의 수소이온은 중간 유체인 알지네이트 프리폴리머와의 계면을 통해 확산되어 Ca-EDTA 복합체로부터 칼슘 양이온의 방출을 유발하게 된다. 방출된 칼슘 양이온은 알지네이트 고분자와의 이온 가교를 통해 알지네이트 하이드로 젤을 형성하여, 각 유체의 flow에 따라 알지네이트 튜브를 쉽고 빠르게 제조 가능하였다. 본 연구에서 제조된 알지네이트 튜브는 인체 내 장기간 약물 전달을 위한 나노섬유로 활용하거나 인공혈관을 구성하는 extracellular matrix로 활용될 잠재력을 가지고 있어 추후 활발한 연구개발이 진행될 예정이다.

  • PDF

Performance Assessment of Passive Micromixer using Numerical Analysis (수치해석을 이용한 패시브 마이크로 믹서의 성능평가)

  • Lee, Jeong-Ick;Kim, Chul-Kyu
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.10
    • /
    • pp.237-242
    • /
    • 2018
  • A micromixer is a component of a lab-on-a-chip or microfluidic device that mixes two or more chemicals together(convergence). The purpose of this study is to assess the performance of passive micromixer of various shapes. Six shapes of micromixers were compared and three dimensional modeling was carried out to have the same hydraulic diameter. The commercial code, ANSYS Fluent, was used to simulate the internal mixing flow. A numerical analysis method is described in detail in this paper. The performance of the micromixer was compared with the mixing index and pressure drop. Consequently, the CDM-8T shape showed reasonable mixing performance and relatively low pressure drop.

A Study on the Wearing Analysis of Insert Tip and Chip's Shape in Turning Operations (선삭가공에서의 인서트 팁의 마모분석과 칩의 형상에 관한 연구)

  • Park, Dong-Keun;Lee, Joon-Seong;Jo, Gye-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2430-2435
    • /
    • 2015
  • In order to achieve high flexibility in manufacture, analysis of chip's shape is one of the most important problems. This paper describes the change of machining characteristics in workpiece materials depending on turning clearance angle. The experiments start from choosing three workpiece materials that are SM45C(machine structural carbon steel), STS303(stainless steel), SCM415 (chrome-molybdenum steel). Then, the experiments show specifically how features of selected materials changed when they were processed with diverse machining depths and with feed rate starting from fixed rotational speed. Especially, the experiments were also analyzed in chip's shape and wear of insert tip. In conclusion, these experiments show that chip's shape was changed by quality of the materials, depth of cut, and conveying speed. When machining feedrate and machining depth were 0.10mm/rev and 0.3mm respectively, workpiece materials showed the best shapes, not categorizing quality of the materials and machining characteristics.

The Fabrication and Characteristics of Micro Heat Pipe for IC Chip Cooling (IC 칩 냉각용 초소형 히트 파이프의 제작 및 성능 평가)

  • Park, Jin-Sung;Choi, Jang-Hyun;Cho, Hyoung-Chul;Yang, Sang-Sik;Yoo, Jae-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.586-588
    • /
    • 2000
  • 본 논문은 전자 패키징의 방열 성능을 개선하기 위하여 초소형 히트 파이프를 제작하고 열전달 성능을 시험한 결과를 보여준다. IC 칩이 점점 고성능화되고 고집적화되어 감에 따라 발열 문제가 대두되는데, 이 열은 전도만으로는 충분히 소산시킬 수 없고 패키징 표면에 별도의 장치를 장착하는 것은 시스템 소형화의 장애 요소가 된다. 따라서, 고성능 칩 개발을 위한 선결 과제로 고성능 초소형 냉각 장치가 요구되고 있다. 히트파이프는 밀봉된 파이프 내의 2상 유동과 상변화 잠열을 이용하여 열원으로부터 히트 싱크로 열을 효과적으로 전달하는 열교환 장치이다. 본 논문에서는 전자 패키징 내에 집적화할 수 있도록 초소형 히트 파이프 어레이를 제작하여 그 성능을 시험한 결과 증발부의 온도가 $12.1^{\circ}C$ 감소됨을 보인다.

  • PDF

Development of Microchip Removal Equipment Using Neodymium Permanent Magnets (네오디뮴 영구자석을 이용한 미세칩 제거장치의 개발)

  • Choi, Sung-Yun;Wang, Jun-hyeong;Wang, Duck Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.3
    • /
    • pp.122-128
    • /
    • 2021
  • Machining operations require removal of chips to keep the coolant clean and fresh throughout the operation time. In this study, microchip removal equipment was developed using AutoCAD and CATIA programs for 3D modeling and 2D draft. In addition, the flow analysis and electromagnetic field analysis of the equipment were performed using the COMSOL Multiphysics program. The flow design of the coolant oil tank was realized on the basis of fluid analysis results. Further, on the basis of magnetic density analysis, a conveyer was designed for effectively removing metal microchips in the tank by using arrays of neodymium permanent magnets.

Simulation of liquid crystal polymer injection molded parts with thin wall and multi holes (다공성 액정고분자 박판의 사출성형 전산모사)

  • 정만석;김성훈
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2001.10a
    • /
    • pp.287-290
    • /
    • 2001
  • 최근 정보통신 산업의 급속한 발전으로 이동 통신용 단말기 및 반도체 칩 케리어 등의 플라스틱 부품의 초소형 경량화 요구가 증대되고 있다. 미세 사출성형용(micro injection molding) 박판의 사출을 위한 미세사출 성형 고분자 재료는 매우 우수한 용융 유동 특성을 가져야 하고, 반도체나 소형 엔지니어링 부품으로 사용하려면 높은 인장강도, 충격강도 및 치수안정성을 가져야 한다. (중략)

  • PDF

A Numerical Simulation on Mixing Enhancement by Inlet Flow Pulsation in a Micro Conduit (마이크로 유로에서 맥동유동에 의한 혼합촉진에 관한 수치해석)

  • Kim, Seo-Young;Rhee, Gwang-Hoon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.231-237
    • /
    • 2003
  • A numerical study has been conducted to investigate the effect of an inlet flow pulsation on mixing of two solutions with different concentrations in a micro conduit. We treat an unsteady, incompressible and two-dimensional flow through a micro conduit by adopting the momentum equations with the electrostatic force due to streaming current and the concentration equation. The feasibility of the inlet flow pulsation to enhance the mixing process inside the micro conduit is carefully examined by varying the inlet pulsation frequency. When a low-frequency pulsation is induced at the inlet, the interface between two solutions with different concentrations becomes wavy, which results in mixing enhancement. As the pulsation frequency increases, the waviness of the interface becomes meager, and the concentration gradients at the interface approach the value for the non-pulsating steady flow.

  • PDF