• Title/Summary/Keyword: '-고'

Search Result 45,380, Processing Time 0.064 seconds

Change of Serum Levels of C-Reactive Protein After Coronary Angioplasty and Its Effects on Clinical Restenosis (협심증 환자에서 관동맥중재술에 따른 C-reactive Protein의 변화 및 임상경과)

  • Park, Jong-Seon;Hong, Gu-Ru;Lee, Chae-Hoon;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.2
    • /
    • pp.215-225
    • /
    • 2001
  • Background: There are many evidences that inflammation is an important determinant of the development of atherosclerosis and one of the systemic markers of inflammation, C-reactive protein(CRP), is associated with extent of coronary artery disease and risk of coronary events. We assessed the time response of CRP response after coronary angioplasty and it's influence on the clinical restenosis in angina patients. Materials and Methods: Patients included 36 angina patients undergoing single vessel angioplasty. Levels of CRP were measured before and 12, 24, 48, and 72 hours after angioplasty. Clinical restenosis was assessed at 6 months after procedure. Results: Baseline CRP level was $0.30{\pm}0.01$ mg/dL in stable and $0.46{\pm}0.28$ mg/dL in unstable angina patients(p<0.05). After angioplasty, CRP level was increased with peak at 24 hour and persisted to 72 hours after angioplasty. At 24 hour after angioplasty, the magnitude of CRP change was $0.32{\pm}0.31$ mg/dL in stable and $0.79{\pm}0.73$ mg/dL in unstable angina patient(p<0.05). The change of CRP level was not associated with troponin-T after angioplasty. In unstable angina patients, clinical restenosis was developed in 8% of patients with low baseline CRP levels and in 50% of those with high baseline CRP levels more than 0.6 mg/dL(p<0.05). Conclusion: In unstable angina patients, inflammatory response is more increased than stable angina patients, and increased inflammatory response effects on the restenosis after coronary angioplasty.

  • PDF

Diagnostic Value of Serum Beta-hCG Measured by EIA in Suspected Ectopic Pregnancy (EIA로 측정한 혈청 ${\beta}$-hCG치의 자궁외 임신에 대한 진단적 가치)

  • Park, Yoon-Ki;Kim, Jong-Wook;Lee, Tae-Hyung;Park, Wan-Seok;Lee, Sung-Ho;Chung, Wun-Yong
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.221-227
    • /
    • 1985
  • Thirty-four patients with suspected ectopic pregnancy whose serum hCG levels had been measured by beta-hCG EIA before surgery were evaluated retrospectively. The results were as follows: 1. Final diagnosis of thirty-four patients with suspected ectopic pregnancy comprised twenty- eight tubal pregnancy, five ruptures of hemorrhagic corpus luteum and, one tubo-ovarian abscess. One of the five patients with rupture of hemorrhagic corpus luteum was accompanied by missed abortion. 2. Range of serum hCG levels in twenty-eight patients with tubal pregnancy was 59-21,980 mIU/ml and that of four patients with rupture of hemorrhagic corpus luteum and one patient with tubo-ovarian abscess was 0.6-6.6mIU/ml. Serum hCG level of a patient with rupture of hemorrhagic corpus luteum who was accompanied by missed abostion was 200 mIU/ml. 3. Serum hCG levels in twenty-two of twenty-eight patients with tubal pregnancy were lower than 3,000 mIU/ml. Low serum hCG level below 100mIU/ml and high serum hCG level above 6,500 mIU/ml were noticed in four and six patients with tubal pregnancy, respectively. 4. Mean serum hCG levels (${\pm}SD$) of twelve patients with tubal pregnancy who had intra-abdominal free blood of less than 500ml and sixteen patients with tubal pregnancy who had intra-abdominal free blood of more than 500ml were 4,131 (${\pm}7,801$) mIU/ml and 3,208 (${\pm}5,081$) mIU/ml, respectively. There was no statistical difference in the mean level of serum hCG between both group (P>0.05). 5. Mean serum hCG levels (${\pm}SD$) of thirteen patients with unruptured tubal pregnancy and fifteen patients with ruptured tubal pregnancy were 2,628 (${\pm}5,448$) mIU/ml and 4,449 (${\pm}6,938$) mIU/ml, respectively. Mean level of serum hCG was statistically higher in ruptured tubal pregnancy (P<0.01). 6. Positive rate of urine pregnancy test in the diagnosis of ectopic pregnancy was 64% (16/25) and mean range of serum hCG level of nine patients with false negative result were 353 mIU/ml and 59-933 mIU/ml.

  • PDF

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

Response for Lead Block Thickness of Parallel Plate Detector using Dielectric Film (유전체필름을 이용한 평행판검출기의 납 차폐물 두께변화에 대한 반응)

  • Kim Yong-Eun;Cho Moon-June;Kim Jun-Sang;Oh Young-Kee;Kim Jhin-Kee;Shin Kyo-Chul;Kim Jeung-Kee;Jeong Dong-Hyeok;Kim Ki-Hwan
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • A parallel plate detector containing PTFE films in FEP film for relative dosimetry was designed to measure the response of detectors to S and 10 MV X-rays from a medical linear accelerator through different thicknesses of lead. The dielectric materials were 100 m thick. The set-up conditions for measurements with this detector were as follows: SSD=100 cm the test detector was at a depth of 5 cm and the reference chamber was at a depth of 10 cm from the phantom surface for 6 and 10 MV X-rays. Lead blocks were designed to cover the irradiated field. They were added to the tray to increase thickness sequentially. We found that the detector response decreased exponentially with the thickness of lead added. The linear attenuation coefficients of the test detector and reference chamber were 0.1414 and 0.541, respectively, for 6 MV X-rays and 0.1358 and 0.5279 for 10 MV X-rays. The test detector response was greater than that of the reference chamber. The response function was calculated from the measured values of the test detector and reference chamber using optimization. These optimized constants for the detector response function were independent of theenergy. As a result of optimizing the response function between detectors, the use of a relative dosimeter was validated, because the response of the test detector was 1% for 6 MV X-rays and 4% for 10 MV X-rays.

  • PDF

Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator ($N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2012
  • For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor $N_x$ or air kerma calibration factor $N_k$ of air ionization chamber. We used the exposure calibration factor $N_x$ to find the absorbed dose calibration factors of water in a reference source through the TG-21 and TRS-277 protocol. TG-21 used for determine the absorbed dose in accuracy, but it required complex calculations including the chamber dependent factors. The authors obtained the absorbed dose calibration factor $N_{dw}{^{Co-60}}$ for reduce the complex calculations with unknown $N_{dw}$ only with $N_x$ or $N_k$ calibration factor in a TM31010 (S/N 1055, 1057) ionization chambers. The results showed the uncertainty of calculated $N_{dw}$ of IC-15 which was known the $N_x$ and $N_{dw}$ is within -0.6% in TG-21, but 1.0% in TRS-277. and TM31010 was compared the $N_{dw}$ of SSDL to that of PSDL as shown the 0.4%, -2.8% uncertainty, respectively. The authors experimented with good agreement the calculated $N_{dw}$ is reliable for cross check the discrepancy of the calibration factor with unknown that of TM31010 and IC-15 chamber.

A Study of Various Filter Setups with FBP Reconstruction for Digital Breast Tomosynthesis (디지털 유방단층영상합성법의 FBP 알고리즘 적용을 위한 다양한 필터 조합에 대한 연구)

  • Lee, Haeng-Hwa;Kim, Ye-Seul;Lee, Youngjin;Choi, Sunghoon;Lee, Seungwan;Park, Hye-Suk;Kim, Hee-Joung;Choi, Jae-Gu;Choi, Young-Wook
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.271-280
    • /
    • 2014
  • Recently, digital breast tomosynthesis (DBT) has been investigated to overcome the limitation of conventional mammography for overlapping anatomical structures and high patient dose with cone-beam computed tomography (CBCT). However incomplete sampling due to limited angle leads to interference on the neighboring slices. Many studies have investigated to reduce artifacts such as interference. Moreover, appropriate filters for tomosynthesis have been researched to solve artifacts resulted from incomplete sampling. The primary purpose of this study is finding appropriate filter scheme with FBP reconstruction for DBT system to reduce artifacts. In this study, we investigated characteristics of various filter schemes with simulation and prototype digital breast tomosynthesis under same acquisition parameters and conditions. We evaluated artifacts and noise with profiles and COV (coefficinet of variation) to study characteristic of filter. As a result, the noise with parameter 0.25 of Spectral filter reduced by 10% in comparison to that with only Ramp-lak filter. Because unbalance of information reduced with decreasing B of Slice thickness filter, artifacts caused by incomplete sampling reduced. In conclusion, we confirmed basic characteristics of filter operations and improvement of image quality by appropriate filter scheme. The results of this study can be utilized as base in research and development of DBT system by providing information that is about noise and artifacts depend on various filter schemes.

Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT (급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교)

  • Kim Hye-seon;Park Dong Woo;Kim Yongsoo;Kim Young-sun;Choi Yo Won;Jeon Seok Chul;Seo Heung Suk;Hahm Chang Kok;Kim Soon Kil;Ahn You hern;Choi Yoon Young;Park Choong-Ki
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Purpose : To assess the usefulness of cardiac MR imaging (MRI) in the diagnosis of acute myocardial infarction and in the assessment of myocardial viability in comparision with T1-201 SPECT. Materials and Methods : We retrospectively studied 17 patients who complained of chest pain and dyspnea with cardiac MRI . The patients were evaluated for the presence or absence of high signal intensity on T2-weighted image (T2wI), abnormal wall motion on 2D-FIESTA, perfusion defect on Gd-DTPA enhanced T1WI, and delayed myocardial enhancement on 15-minutes delay Gd-DTPA enhanced T1WI. The results were correlated with the images on T1-201 SPECT, taken at rest and stress, through which reversibility of perfusion defect was assessed. Results : Both cardiac MRI and T1-201 SPECT proved to be useful methods for diagnosing acute myocardial infarction. In order of decreasing correspondence, T2WI, T1-201 SPECT, delayed enhancement study, and wall motion images all showed significant statistical correlation with the clinical diagnosis of myocardial infarction. Perfusion MRI, on the other hand, showed no significant statistical difference was found between T1-201 SPECT and cardiac MRI. The results on T2WI showed high accordance with those on Tl-201 SPECT, while delayed myocardial enhancement and wall motion studies showed no agreement with Tl-201 SPECT. Conclusion : Cardiac MRI is useful method for diagnosis of acute myocardiac infarction. With respect to the assessment of myocardial viability, the results obtained on cardiac MRI showed high agreement with those on Tl-201 SPECT. However, further study is necessary at this point for standardization and establishment of the methods for assessing myocardial viability on cardiac MRI.

  • PDF

Acute Cerebral Infarction in a Rabbit Model: Perfusion and Diffusion MR Imaging (가토의 급성 뇌경색에서 관류 및 확산강조 자기공명영상)

  • Heo Suk-Hee;Yim Nam-Yeol;Jeong Gwang-Woo;Yoon Woong;Kim Yun-Hyeon;Jeong Young-Yeon;Chung Tae-Woong;Kim Jeong;Park Jin-Gyoon;Kang Heoung-Keun;Seo Jeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.116-123
    • /
    • 2003
  • Purpose : The present study was undertaken to evaluate the usefulness of cerebral diffusion (DWI) and perfusion MR imaging (PWI) in rabbit models with hyperacute cerebral ischemic infarction. Materials and Methods : Experimental cerebral infarction were induced by direct injection of mixture of Histoacryl glue, lipiodol, and tungsten powder into the internal cerebral artery of 6 New-Zealand white rabbits, and they underwent conventional T1 and T2 weighted MR imaging, DWI, and PWI within 1 hour after the occlusion of internal cerebral artery. The PWI scan for each rabbit was obtained at the level of lateral ventricle and 1cm cranial to the basal ganglia. By postprocessing using special imaging software, perfusion images including cerebral blood volume (CBV), cerebral blood flow (CBF), and mean transit time (MTT) maps were obtained. The detection of infarcted lesion were evaluated on both perfusion maps and DWI. MTT difference time were measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Results : In all rabbits, there was no abnormal signal intensity on T2WI. But on DWI, abnormal high signal intensity, suggesting cerebral infarction, were detected in all rabbits. PWI (rCBV, CBF and MTT map) also showed perfusion defect in all rabbits. In four rabbits, the calculated square of perfusion defect in MTT map is larger than that of CBF map and in two rabbits, the calculated size of perfusion defect in MTT map and CBF map is same. Any rabbits do not show larger perfusion defect on CBF map than MTT map. In comparison between CBF map and DWI, 3 rabbits show larger square of lesion on CBF map than on DWI. The others shows same square of lesion on both technique. The size of lesion shown in 6 MTT map were larger than DWI. In three cases, the size of lesion shown in CBF map is equal to DWI. But these were smaller than MTT map. The calculated square of lesion in CBF map, equal to that of DWI and smaller than MTT map was three. And in one case, the calculated square of perfusion defect in MTT map was largest, and that of DWI was smallest. Conclusion : DWI and PWI may be useful in diagnosing hyperacute cerebral ischemic infarction and in e-valuating the cerebral hemodynamics in the rabbits.

  • PDF

Gadolinium-Enhanced Magnetic Resonance Imaging of Atherosclerotic Plaques in Comparison with Histopathology: An In Vivo Study in Aorta of Rabbits (조직병리와 비교한 죽상경화반의 가돌리니움 조영증강 자기공명영상: 토끼 대동맥을 이용한 생체 실험)

  • Choi, Byoung-Wook;Hur, Jin;Lee, Hye-Jeong;Kim, Young-Jin;Kim, Tae-Hoon;Choe, Kyu-Ok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.81-87
    • /
    • 2009
  • Purpose : We sought to evaluate enhancement of plaque with gadolinium-based contrast agent by magnetic resonance imaging (MRI) in comparison with histopathology, namely lipid-rich and macrophage-rich components that were two representative characteristics of plaque vulnerability using atherosclerotic rabbit aorta in order to determine which histopathologic component is relevant to the enhancement. Materials and Methods : New Zealand white rabbit (n=4, weight 3.0 to 3.5 kg, all male) was used for animal model of atherosclerosis. Atherosclerotic aortic lesions were induced by high-cholesterol diet and double balloon injury. T1-weight axial images were acquired before and after gadolinium-based contrast agent using a 3-T MRI. MR images and the matched histopathological sections (n=35) were divided into 4 quadrants or 3 (n=130). Enhancement ratio (ER, ER=SIpost/SIpre) on MRI was calculated for each quadrant and compared with histopathology in regard to lipid-rich and macrophage-rich areas. Results : Lipid-rich quadrants were 72 and fibrous quadrants were 58. The number of quadrants which had macrophage-rich areas was 105 and that of quadrants which did not have macrophage-rich areas was 25. ER was significantly higher in lipid-rich quadrants than in fibrous quadrants (mean ER 2.25c$\pm$0.41 vs. 2.72$\pm$0.65, p=0.013). ER poorly correlated with macrophage-rich areas when lipid-component was controlled (correlation coefficient -0.203, p=0.236). Conclusion : Lipid-rich plaques showed stronger enhancement than fibrous plaques using a standard gadolinium-based extracellular contrast agent. Macrophage infiltration did not correlate with degree of enhancement. Further study is warranted that account for optimal time of imaging after contrast injection using various plaque models from early to advanced stages and all possible parameters associated with contrast enhancement.

  • PDF

Consideration on the Musicality of Modern Sijo (현대 시조의 음악성 고(考))

  • Sin, Woong-Sun
    • Sijohaknonchong
    • /
    • v.42
    • /
    • pp.7-28
    • /
    • 2015
  • This article defines sijo's musicality in two ways and verifies how musicality is shown in modern sijo with some examples. First, the first metre of a song's fourth part, that is, the sijo's jongjang, should include a reverse of its poetic image. A song consists of five parts. Each part is sung as a part of the song, that is, the sijo's dimetre, trimetre, or tetrametre, but its fourth part is sung as the monometre which is the first metre of its jongjang. This is because the first metre of a sijo's jongjang forms the axis of the reverse in its poetic image, and when this works properly, it can maintain musicality as a sijo. Second, a sijo's tetrametre and sijo-chang's gak should correspond as the same value along with the completion of its meaning. If a sijo does not keep the metre, each part's completion of meaning and also the sijo-chang's gak become problematic, so it is impossible to perform sijo-chang. Only when each part's completion of meaning and the gak of the metre correspond to each other as the same value, the sijo can maintain its musicality. Next, the study verifies how musicality is shown in modern sijo. This was examined through the examples of gyeol-metre and yangjang-sijo in dan-sijo that cannot form any tongsa madi, arrangement of syllable units beyond metres, or the examples of loose reverse of meaning in a transitional phrase. The two kinds of musicality presented by this author have already been proved with old sijo. However, modern sijo has been created mainly centering around its image, so such musicality has been ignored and sijo's identity has been damaged seriously. In sijo, musicality gives life. If modern sijo is created mainly around its image, it can never be called as sijo unless it has musicality. Although modern sijo is not performed as music, it should be equipped with the form to be performed as a chang. This is how sijo can maintain its musicality. It is thought that now is the time to recognize modern sijo as the matter of communication between sijo-chang and sijo literature, not just as the combination of sijo-chang and sijo literature.

  • PDF