• Title/Summary/Keyword: '-고'

Search Result 45,380, Processing Time 0.06 seconds

A Selection of High Pedestrian Accident Zones Using Traffic Accident Data and GIS: A Case Study of Seoul (교통사고 데이터와 GIS를 이용한 보행자사고 개선구역 선정 : 서울시를 대상으로)

  • Yang, Jong Hyeon;Kim, Jung Ok;Yu, Kiyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.3
    • /
    • pp.221-230
    • /
    • 2016
  • To establish objective criteria for high pedestrian accident zones, we combined Getis-ord Gi* and Kernel Density Estimation to select high pedestrian accident zones for 54,208 pedestrian accidents in Seoul from 2009 to 2013. By applying Getis-ord Gi* and considering spatial patterns where pedestrian accident hot spots were clustered, this study identified high pedestrian accident zones. The research examined the microscopic distribution of accidents in high pedestrian accident zones, identified the critical hot spots through Kernel Density Estimation, and analyzed the inner distribution of hot spots by identifying the areas with high density levels.

A Study on the Frequency and Intensity Variations of Okhotsk High: Focused on the Korean Peninsula (오호츠크해고기압의 출현일과 강도의 변동에 관한 연구 -한반도에 영향을 미친 날을 중심으로-)

  • Cho, Li-Na;Lee, Seung-Ho
    • Journal of the Korean Geographical Society
    • /
    • v.46 no.1
    • /
    • pp.36-49
    • /
    • 2011
  • This paper aims to investigate the frequency and intensity variations of Okhotsk high pressure system focused on the Korean Peninsula. Weather chart (00UTC), daily weather data and reanalysis data were used. The first occurrence date of Okhotsk high pressure system tends to be earlier in those years that surrounding land air temperature in April is high. The frequency of Okhotsk high has recently decreased, and its intensity tends to be stronger when the difference between sea surface temperature and surrounding land air temperature is big. The frequency of Okhotsk high in April, May, June and July increases when surrounding land air temperature is high, and its intensity grows when the difference between surrounding land air temperature and sea surface temperature is big. The frequency of Okhotsk high may increase and its intensity may increase when the first occurrence date comes earlier. In June, however, the reverse may apply.

High-definition Video Enhancement Using Color Constancy Based on Scene Unit and Modified Histogram Equalization (장면단위 색채 항상성과 변형 히스토그램 평활화 방법을 이용한 고선명 동영상의 화질 향상 방법)

  • Cho, Dong-Chan;Kang, Hyung-Sub;Kim, Whoi-Yul
    • Journal of Broadcast Engineering
    • /
    • v.15 no.3
    • /
    • pp.368-379
    • /
    • 2010
  • As high-definition video is broadly used in various system such as broadcast system and digital camcorder the proper method in order to improve the quality of high-definition video is needed. In this paper, we propose an efficient method to improve color and contrast of high-definition video. In order to apply the image enhancement method to high-definition video, scale-down video of high-definition video is used and the parameter for image enhancement method is computed from small size video. To enhance the color of high-definition video, we apply color constancy method. First, we separate the video into several scenes by cut detection method. Then, we apply color constancy to each scene with same parameter. To improve the contrast of high-definition video, we use union of original image and histogram equalized image, and weight is calculated based on sorting of histogram bins. Finally, the performance of proposed method is demonstrated in experiment section.

An Experimental Study on The Fire Resistance Performance of High Strength Concrete Column mixed Fiber-Cocktail in Standard Fire Condition (하이브리드 섬유를 적용한 고강도 내화콘크리트의 단면크기에 따른 내화성능에 관한 실험적 연구)

  • Kim, Heung-Youl;Kim, Hyung-Jun;Cho, Bum-Yean;Min, Byung-Youl;Ahn, Chan-Sol
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.170-175
    • /
    • 2011
  • 최근 고강도 콘크리트의 내화성능이 사회적 이슈로 부각되고 국토해양부에서 고강도 콘크리트의 내화성능 관리기준(안)이 고시되면서 국내에서도 고강도 콘크리트의 내화성능을 향상시키기 위한 연구가 활발히 진행되고 있다. 본 연구에서는 유기질 섬유인 폴리프로필렌섬유(PP섬유)와 강섬유를 하이브리드한 Fiber Cocktail를 혼입한 고강도 내화콘크리트 개발을 위한 연구를 수행하였다. PP섬유는 $160^{\circ}C$의 온도에서 용융되어 콘크리트 내부에 미세한 통로를 형성하여 고강도 콘크리트 부재 내의 수증기압 및 공극압을 효과적으로 배출하여 고강도 콘크리트의 폭렬발생을 억제시키는 데 효과적이며, 강섬유는 PP섬유가 용융된 후의 고강도 콘크리트 부재의 균열 발생을 억제하며 외부로부터 침투하는 열기를 차단할 수 있다. 100MPa 고강도 콘크리트의 내화실험을 실시하여 최적단면 조건을 도출하기 위해 철근온도를 분석한 결과, 단면이 커질수록 철근온도는 점차 낮아지는 경향이 나타났으며 $600{\times}600mm$, $800{\times}800mm$ 단면에서 내화성능을 확보할 수 있는 것으로 나타났으며, 이중 경제성을 고려할 경우 $600{\times}600mm$ 단면이 최적단면으로 도출되었다. 또한 도출된 $600{\times}600mm$ 단면에 대해서 철근의 온도를 분석한 결과 PP섬유 $1.5kg/m^3$와 강섬유 $40kg/m^3$를 배합한 Fiber Cocktail이 최적배합비로 나타났다.

  • PDF

Exposure-Limit Distance as a Safety-Indicating Parameter of a High-Intensity Flash Source (고광도 섬광의 안전지표로서 노출제한거리)

  • Park, Seung-Man;Kim, Sang-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.16-21
    • /
    • 2017
  • A systematic understanding of the effects of high-intensity flash sources on the human eye is strongly needed, not only for proper use of the sources, but for human eye health. In this study, the exposure-limit distance (ELD), indicating the minimal safe distance in case of seeing by chance a high-intensity flash, is proposed. The optical procedures to determine the ELD of a high-intensity flash are clarified, and the dependence of ELD on its parameters such as luminous intensity, duration, and radius of a flash are thoroughly investigated. From this investigation it is obvious that, while being weakly dependent on duration, the ELD is nearly proportional to the luminous intensity and the radius of a flash. The proposed ELD as an intuitive safety-indicating parameter is more useful and intuitive than the other characteristic parameters of a high-intensity flash. The ELD is expected to be an essential parameter as a safety indicator, to characterize the performance of a high-intensity flash and to promote the safety of the human eye.

Effect of Frequency and Intensity of Transcutaneous Electrical Nerve Stimulation on Patients with Chronic Low Back Pain (경피신경전기자극의 빈도-강도가 만성 요통 환자의 요통장애지수와 유연성에 미치는 영향)

  • Park, Jung-Ho;Song, Brian Byung
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.6
    • /
    • pp.361-370
    • /
    • 2012
  • The Purpose of this study was to find out the effects of frequency and intensity of transcutaneous electrical nerve stimulation(TENS) on the patients with chronic low back pain. The subjects were 32 patients with chronic low back pain average age 39.19 (${\pm}12.96$)years. The duration of chronic low back pain was 8.57 (${\pm}3.07$)months. The treatments were given 15 minutes once a day five a week for two weeks. to low back. Lumbar range of motion(ROM) and Oswestry Disabilitv Index(ODI)) was evaluated before and after TENS application. Each group was compared using Wilcoxon Mann-Whitney test. The results were as followings: Each group showed significant effect. High intensity group showed more effect in low frequency group. High intensity group showed more effect in high frequency group. Therefore, the high intensity can be used more effectively with high frequency for treating chronic low back pain.

An Efficient Management by Analyzing Control Level of Hypertension (고혈압 관리수준에 따른 효율적인 관리 방안)

  • Kim, Ji-On
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.369-379
    • /
    • 2013
  • The purpose of this study is to contribute basic data toward the efficient management of Hypertension by comprehensive analysis of several factors which make influences on indicators of Hypertension management. To achieve this, using the data of 2007, 2008 Korea National Health and Nutrition Examination Survey, 2,580 adults aged over 19 who suffered from hypertension have been analyzed comprehensively. The major results can be summarized as follows: First, in regard to the influential factors for awareness and treatment of hypertension, the older the patients were, the poorer their self-rated health status were. And when they had experienced a health examination, the more likely the hypertensive patients were aware of their hypertension and took the treatment for it. Second, as for the influential factors for control of hypertension, those who were older and those who had a health examination were significantly more likely to control their hypertension irrespective of gender. However, regular drinkers fell significantly behind in that aspect. The findings of this study show that systematic hypertension management, focusing on health behavior factors that affect the level of hypertension management, in accordance with the patients' sex and age will provide a more efficient way.

고속파 전자가열을 시도한 KSTAR 토카막 원형 플라즈마에서의 ICRF 고주파 부하 저항

  • Wang, Seon-Jeong;Kim, Seon-Ho;Gwak, Jong-Gu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.297-297
    • /
    • 2010
  • KSTAR 토카막의 두번째 실험 캠페인 동안 고속파 전자가열 (FWEH)을 위한 ICRF 고주파입사 실험을 실시하였다. 토로이달 자기장은 2 T, 플라즈마 전류는 200-300 kA, 주반경은 1.8 m, 부반경은 0.5 m의 원형 플라즈마가 가열 대상이 되었으며, 네개의 ICRF 안테나 전류띠 가운데 중심부의 두개의 전류띠를 최대 300 kW로 구동하기 위한 운전 주파수는 44.2 MHz가 선택 되었다. 이 주파수는 플라즈마의 모든 영역에서 이온 사이클로트론 공명을 일으키지 않으므로 플라즈마에 흡수되는 대부분의 출력은 전자에게 전달될 것으로 기대되었다. 낮은 고주파-플라즈마 결합으로 인하여 전송선의 최대 고주파 전압이 허용치를 초과하기 때문에 비교적 낮은 최대 출력만이 허용 되었으나, ECE에 의해 관측된 전자의 온도는 국지적으로 최대 150 % 까지 증가하는 것을 확인 할 수 있었다. 낮은 고주파-플라즈마 결합의 첫번째 원인은 FWEH의 효율이 이온을 가열할 때 보다 상대적으로 낮기 때문이다. 플라즈마 내에 이온 사이클로트론 공명층이 형성되면 높은 효율로 고주파를 입사 할 수 있다는 것은 잘 알려진 사실이다. 또다른 원인은 D 형상의 플라즈마에 맞도록 만들어진 안테나와, 원형 플라즈마간의 부조화로 인하여 고속파 차단층이 (Fast Wave Cutt-off Layer) 평균적으로 넓게 형성되기 때문이다. 플라즈마 외곽에 반드시 존재하는 낮은 플라즈마 밀도의 고속파 차단층 내부에서, 중심부로 향하는 고주파의 진폭은 지수함수로 감쇠하므로 가능하면 플라즈마 밀도를 높여 차단층 자체의 폭을 줄이거나, 안테나 전류띠를 플라즈마에 바짝 접근시켜야만 한다. 고주파 진단 장치로는 송출기의 출력과 반사파 측정 장치, 공명루프의 전압 측정 장치가 있는데, 이것들을 이용하여 안테나에 전달되는 출력 및 고주파-플라즈마 결합 효율을 나타내는 플라즈마에 대한 고주파 부하 저항을 구할 수 있다. 측정 결과, 부하 저항의 최소값은 진공시 또는 ICRF만의 방전시의 값 0.25 Ohm 보다 큰 0.5 Ohm을 나타냈으며, 최대값은 플라즈마의 상태에 따라 1 Ohm에서 2 Ohm 사이에서 매우 빠르게 요동하는 것을 확인했다. Mm 파 반사계의 측정에 의하면 플라즈마 언저리의 위치가 약 3 cm 정도의 크기로 요동하는 것으로 나타났는데, 부하 저항과 언저리 위치의 파형이 정확하게 일치하지 않지만 유사한 경향성을 가진 것으로 보인다. 따라서 플라즈마 언저리 위치의 제어를 통하여 가열 효율을 높게 유지할 수 있음을 알 수 있다. 본 발표에서는 실험의 소개와 함께 부하 저항의 관점에서 가열 효율을 높일 방안을 토론하도록 한다.

  • PDF

OTFT 소자 성능 향상을 위한 고품질 3-Aminopropyltriethoxysilane 자기조립단분자막의 제작

  • Choe, Sang-Il;Jeong, Yun-Sik;Kim, Gyeong-Su;Bae, Yeong-Min;Kim, Seong-Su
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.260-260
    • /
    • 2010
  • OTFT소자는 각 박막계면간의 접촉성에 따라 그 성능이 좌우 된다는 것은 널리 알려진 사실이다. 즉 박막계면간의 접촉성 저하는 계면간의 결함을 형성하여 OTFT소자 성능을 저하시킨다. 이러한 결함을 고품질의 자기조립단분자막을 제작함으로써 박막계면간 결함을 최소화 할 수 있다. 이러한 고품질의 자기조립단분자막 형성은 박막계면간의 결함을 최소화 하기때문에 고성능OTFT소자 제작시 박막계면간 접촉성 향상에 효율적으로 적용할 수 있을것이다. 이 논문에서는 계면간의 접촉성 향상을 위해 실리콘 웨이퍼 위에 3-Aminoproplytriethoxtsilane과 용매인 무수톨루엔을 이용하여 고품질의 자기조립단분자막을 제작 하였으며 고품질을 자기조립단분자막 성장 조건을 찾기 위해 엄격한 수분조절 및 APS농도, 담근시간, 온도를 조절하여 각기 다른 조건의 샘플을 제작하였다. 또한 APS성장 분포를 알기위하여 접촉각 측정기를 이용하여 접촉각을 측정 하였고 AFM 이용하여 실리콘 웨이퍼에 생성된 박막의 균질도를 측정하였다. 그 결과 APS농도(33%) 24시간 $25^{\circ}C$, APS농도(33%) 24시간 $70^{\circ}C$, APS농도(33%) 72시간 $25^{\circ}C$, APS농도 (33%) 72시간 $70^{\circ}C$ 샘플이 기존에 알려진 APS 접촉각인 $19^{\circ}C{\sim}21^{\circ}C$ 접촉각이 나왔으며 AFM 이미지 또한 높은 균질도를 보였다. 이 결과 고품질의 APS단분자막은 농도와 시간 그리고 온도에 영향은 받으며 이렇게 완성된 단분자막은 높은 균질도를 가지게 된다. 현재 실험을 통해 얻어진 고품질의 자기조립단분자막 성장 조건을 이용하여 OTFT소자 제작하고 있으며 고품질의 자기조립단분자막 형성에 의해 결함을 최소화 하므로써 박막계면간 옴성결합을 형성하여 OTFT소자의 성능 향상이 기대되어 진다.

  • PDF

Screening of Zero-Valent Metal for the Removal of High Concentration PCE and 1,1,1 TCA (고농도 PCE 및 1,1,1 TCA 제거를 위한 영가금속 선정)

  • Kwon, Soo-Youl;Kim, Young
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.23-31
    • /
    • 2010
  • Chlorinated aliphatic hydrocarbons (CAHs) such as tetrachloroethylene (PCE), 1,1,1-trichloroethane (1,1,1-TCA) are the contaminants most frequently found in soil and groundwater. They have a potential to be toxic to and persistent in environment. This study is focused on selection of zero-valent metal and ores for the removal of high concentration PCE or 1,1,1-TCA and mixture of two compound. For the screening of suitable metals, we measured dechlorination rate, removal capacities and economics by using batch reactor test. This results suggest that removal rate and dechlorination of high quality iron and zinc are higher than slag and nature ores like zinc and manganese. Among nature ores, zinc ores(64% purity) have highest removal capacities. And in economics zinc ores is 10 times better than high quality metal tested. We conclude zinc ore is most suitable metal for the removal of PCE or 1,1,1-TCA.