• 제목/요약/키워드: % RSD

검색결과 530건 처리시간 0.028초

Testing LCDM with eBOSS / SDSS

  • Keeley, Ryan E.;Shafieloo, Arman;Zhao, Gong-bo;Koo, Hanwool
    • 천문학회보
    • /
    • 제46권1호
    • /
    • pp.47.3-47.3
    • /
    • 2021
  • In this talk I will review recent progress that the SDSS-IV / eBOSS collaboration has made in constraining cosmology from the clustering of galaxies, quasars and the Lyman-alpha forest. The SDSS-IV / eBOSS collaboration has measured the baryon acoustic oscillation (BAO) and redshift space distortion (RSD) features in the correlation function in redshift bins from z~0.15 to z~2.33. These features constitute measurements of angular diameter distances, Hubble distances, and growth rate measurements. A number of consistency tests have been performed between the BAO and RSD datasets and additional cosmological datasets such as the Planck cosmic microwave background constraints, the Pantheon Type Ia supernova compilation, and the weak lensing results from the Dark Energy Survey. Taken together, these joint constraints all point to a broad consistency with the standard model of cosmology LCDM + GR, though they remain in tension with local measurements of the Hubble parameter.

  • PDF

UPLC-DAD를 이용한 불환금정기산의 다성분 동시분석법 개발 (Development of an UPLC-DAD Method for Simultaneous Analysis of Eight Marker Compounds of Bulhwangeumjeonggi-san)

  • 이경희;라미차네 라마칸타;서르마 디박 쿠마르;판데야 프라카스 라즈;김세건;정현주
    • 생약학회지
    • /
    • 제47권4호
    • /
    • pp.366-373
    • /
    • 2016
  • Bulhwangeumjeonggisan (BHGJGS) is a traditional herbal formulation generally used in the treatment of cold and gastritis. BHGJGS consists of eight herbal plants; Atractylodis Rhizoma, Magnoliae Cortex, Citri Pericarpium, Glycyrrhizae Radix, Agastachis Herba, Pinelliae Rhizoma, Zingiberis Rhizoma and Zizyphi Fructus. Complete standardization of this formulation has not been done yet. So, a simple and accurate method was developed and validated using Ultra Performance Liquid Chromatography (UPLC) with Diode Array Detector (DAD) for the standardization of BHGJGS. UPLC conditions were optimized using a c18 RP-Amide column with mobile phase; 0.1% phosphate buffer and acetonitrile, detection wavelength; 210 and 325 nm. The linearities of calibration curves were acceptable ($R^2$>0.9994), and the limit of detection and quantification were within the ranges of 0.011-0.091 and $0.034-0.277{\mu}g/ml$ respectively. The relative standard deviation (RSD) of intra- and inter-day precisions were under 3.61%. The RSD of repeatability was under 0.68 %. The results of recovery test were 94.4-107.9%, and the RSD were under 4.6%. The developed method was used to find the contents of standard constituents in BHGJGS mix extract powder, and two commercial formulation (A and B). The data show that the developed method was specific, sensitive, accurate, and precise for analysis of BHGJGS components.

반사성 교감신경성 위축증 환자에서 척수 자극기를 이용한 통증관리 -증례 보고- (Pain Control by Spinal Cord Stimulation in the Reflex Sympathetic Dystrophy -A case report-)

  • 이상철;김진희;황정원;한미애;김성덕;김계민;이병건
    • The Korean Journal of Pain
    • /
    • 제10권1호
    • /
    • pp.86-88
    • /
    • 1997
  • Regional sympathetic blockade is the most effective treatment for reflex sympathetic dystrophy (RSD). Radiofrequency thermocoagulation provides longer duration of pain relief than local anesthetics and less complication than chemical neurolytic agents for lumbar sympathectomy. Spinal cord stimulation (SCS) is thought to be an effective modality yieding good results in treating intractable neuropathic pain. Therefore RSD might be a good indication for SCS. We treated a patient with RSD who responded well to lumbar sympathetic blockade (LSB) with radiofrequency thermocoagulation and SCS. The patient had a left ankle sprain requiring a case for the lower leg for 2 weeks. The patient suffered increasing pain and swelling on the lower part of that leg. We thought to block the lumbar sympathetic chain utillzing radiofrequency thermocoagulation 2 days after LSB with local anesthetics. The results provided accepatable pain relief (VAS $8{\rightarrow}15$) but the patient still could not walk due to remaining pain which was further aggravated by walking. After SCS, pain relief improved (VAS $5{\rightarrow}13$) and patient could walk without assistance.

  • PDF

Multiphasic Analysis of Growth Curve of Body Weight in Mice

  • Kurnianto, E.;Shinjo, A.;Suga, D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제12권3호
    • /
    • pp.331-335
    • /
    • 1999
  • The present study describes the analysis of the multiphasic growth function (MGF) to body weight in laboratory and wild mice. Three genetic groups of laboratory mice (Mus musculus domesticus) designated $CF_{{\sharp}1}$, C3H/HeNCrj and C57BL/6NCrj, and a genetic group of Yonakuni wild mice (Mus musculus molossinus yonakuni, Yk) were used. Mean body weights of each genetic group-sex subclass from birth to 69 days of age taken at 3-day intervals were analyzed by a monophasic, diphasic and triphasic functions for describing growth patterns. A comparison among the three functions of the MGF was based on the goodness-of-fit criteria: residual standard deviation (RSD), adjusted R-square (Adj $R^2$) and Akaike's information criterion (AIC). Result of this study indicated that body weight averaged heavier for males than for females. Among the four genetic groups within both sexes, $CF_{{\sharp}1}$ showed the highest, subsequent followed by C3H/HeNCrj, C57BL/6NCrj and Yk. Comparison among the three functions revealed that the triphasic function was the best fit to growth data, with the lowest RSD, the highest Adj $R^2$ and the lowest AIC, for the four genetic groups. For the triphasic function, RSD within each genetic group-sex subclass was similar for males and females. Adj $R^2$ was 0.999 for all genetic group-sex subclasses. AIC for laboratory mice males and females ranged from -70.48 to 66.50 and from -92.81 to -68.64, respectively; whereas for Yk wild mice males was -74.29 and females -78.42.

Quantitative Analytical Method for Eighteen Marker Compounds in Ongyeong-tang, a Traditional Herbal Formula, Using High-Performance Liquid Chromatography for Quality Assessment

  • Kim, Jung-Hoon;Shin, Hyeun-Kyoo;Seo, Chang-Seob
    • 대한본초학회지
    • /
    • 제30권4호
    • /
    • pp.11-20
    • /
    • 2015
  • Objectives : Ongyeong-tang (OGT) is a traditional herbal formula used to cure gynaecological disorders. OGT consists of 12 herbal medicines containing various bioactive components. Therefore, the development of suitable analytical method for the marker compounds is necessary for the quality control of OGT. Methods : Determination of the 18 marker compounds in OGT preparations was quantitatively performed by high-performance liquid chromatography-photodiode array detection analysis. The marker compounds were separated on a reversed-phase C 18 column and the analytical method was successfully validated, which was applied to compare OGT extracts from laboratory preparation and commercial OGT granules. Results : Limit of detection and limit of quantification values were in the ranges of $0.001-0.016{\mu}g/mL$ and $0.003-0.047{\mu}g/mL$, respectively. Precision was 0.03-3.71 % within a day and 0.03-3.81 % over four consecutive days. Recovery of marker compounds ranged from 90.63-108.26 %, with relative standard deviation (RSD) values < 4.0 %. Reproducibility was < 2.5 % of the RSD value. The 18 marker compounds were stable within 16 h at $10^{\circ}C$, with the RSD value < 3.5 %. Quantitative analysis results showed that the quantities of the 18 marker compounds varied among OGT samples. Pearson coefficient evaluation and principal component analysis demonstrated that an OGT water extract produced by a laboratory method clearly differed from commercial OGT granules. Conclusions : The developed analytical method was simple, precise, and reliable. Therefore, it can be used for the quality assessment of OGT preparations.

ICP-AES에서 에어로졸의 광산란에 의한 신호의 보정 (Signal compensation by the light scattering of sample aerosols in ICP-AES)

  • 연평흠;박용남
    • 분석과학
    • /
    • 제25권4호
    • /
    • pp.223-229
    • /
    • 2012
  • 시료 에어로졸에 의한 광산란 신호를 이용하여 ICP 분석신호를 보정하였다. 자체 제작한 초음파 분무기에서 발생되는 에어로졸에 대하여 다이오드나 He-Ne 레이저를 사용하여 광산란신호를 얻고 이를 기준으로 하여 분석신호의 변동에 대하여 보정하였다. 그 결과 Be, Pb 및 Co의 경우에 short-term (1분 이하)에 대한 신호의 RSD가 기존의 평균 3.4% 에서 0.9% RSD 이하로 큰 개선이 되었으며, 10분 정도의 long-term안정도는 14.9%에서 4.2%로 개선되었다. 이 방법은 펄스형태의 시료도입뿐 아니라 연속적 분무에서도 분무기의 안정성이 부족한 경우, 정밀도의 개선에 매우 유용하다. Long-term의 안정도 개선을 위해서는 광산란셀에서의 안정도 및 검출기의 잡음개선과 분무장치와 플라즈마 사이에서의 에어로졸 응축등에 의한 잡음의 개선이 필요한 것으로 보인다.

상온 겔프린팅 기법을 이용한 비파괴 검사용 방사선 증감지 제작 및 평가 (The Evaluation and Fabrication of Radiation Phosphor Screen for Non-destructive Testing using the Special Room Temperature Gel-printing Method)

  • 이준행
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.391-396
    • /
    • 2020
  • 본 연구는 Gd2O2S:Tb 형광체 화합물을 사용하여 비파괴검사 중 방사선투과검사에 적용할 수 있는 형광체 증감지를 개발하였다. 또한 이러한 형광체 증감지를 FE-SEM, RMS 및 RDS 분석을 통해 형광체 증감지의 영상 균일도를 분석하였다. 또한, 응력-변형 특성 곡선 측정을 통해 Gd2O2S:Tb 형광체 스크린의 인장강도, 신장률 및 탄성계수를 평가하였다. 실험 결과, RSD 값이 평가 기준인 10% 이내로 우수한 영상균일도를 가지는 것으로 평가되었다. 또한, 물리적 특성 평가 결과, 인장 강도는 1.1760 N/㎟이며, 파단시 인장강도는 1.1515 N/㎟로 나타났다. 이러한 결과로부터 본 연구에서 제작된 상온 겔-프린팅 제조법을 이용하여 제작된 Gd2O2S:Tb 형광체 스크린은 방사선 투과검사용 디지털 방사선 검출기에 적용이 가능할 것으로 사료된다.

Preparation of Metal-p-aminobenzyl-DOTA Complex Using Magnetic Particles for Bio-tagging in Laser Ablation ICP-MS

  • Yoon, S.Y.;Lim, H.B.
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권11호
    • /
    • pp.3665-3670
    • /
    • 2012
  • Metal-p-$NH_2$-Bn-DOTA (paraammionobenzyl-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid: ABDOTA) complex was synthesized and purified for bio-tagging to quantify biological target materials using laser ablation (LA)-ICP-MS. Since the preparation of a pure and stable tagging complex is the key procedure for quantification, magnetic particles were used to purify the synthesized metal-ABDOTA complex. The magnetic particles immobilized with the complex attracted to a permanent magnet, resulting in fast separation from free un-reacted metal ions in solution. Gd ions formed the metal-complex with a higher yield of 64.3% (${\pm}3.9%$ relative standard deviation (RSD)) than Y ions, 52.3% (${\pm}2.5%$ RSD), in the pH range 4-7. The complex bound to the magnetic particles was released by treatment with a strong base, of which the recovery was 81.7%. As a reference, a solid phase extraction (SPE) column packed with Chelex-100 resin was employed for separation under similar conditions and produced comparable results. The tagging technique complemented polydimethylsiloxane (PDMS) microarray chip sampling in LA-ICP-MS, allowing determination of small sample volumes at high throughputs. For application, immunoglobulin G (IgG) was immobilized on the pillars of PDMS microarray chips and then tagged with the prepared Gd complex. IgG could then be determined through measurement of Gd by LA-ICP-MS. A detection limit of 1.61 ng/mL (${\pm}0.75%$ RSD) for Gd was obtained.

Development of Jaspine B analysis using LC-MS/MS and its application: Dose-independent pharmacokinetics of Jaspine B in rats

  • Song, Im-Sook;Jeon, Ji-Hyeon;Lee, Jihoon;Lim, Dong Yu;Lee, Chul Haeng;Lee, Dongjoo;Choi, Min-Koo
    • 분석과학
    • /
    • 제34권2호
    • /
    • pp.37-45
    • /
    • 2021
  • A rapid and simple LC-MS/MS analytical method in determining Jaspine B has been developed and validated in rat plasma. The standard curve value was 25 - 5000 ng/mL and the linearity, inter-day and intra-day accuracy and precision were within 15.0 % of relative standard deviation (RSD). The mean recoveries of Jaspine B ranged from 87.5 % to 91.2 % with less than 3.70 % RSD and the matrix effects ranged from 91.1 % to 108.2 % with less than 2.6 % RSD. The validated LC-MS/MS analytical method of Jaspine B was successfully applied to investigate the dose-escalated pharmacokinetic study of Jaspine B in rats following an intravenous injection of Jaspine B at a dose range of 1 - 10 mg/kg. The initial plasma concentrations and area under plasma concentration curves showed a good correlation with intravenous Jaspine B dose, indicating the dose independent pharmacokinetics of Jaspine B in rats. In conclusion, this analytical method for Jaspine B can be easily applied in the bioanalysis and pharmacokinetic studies of Jaspine B, including its administration at multiple therapeutic doses, or for making pharmacokinetic comparisons for the oral formulations of Jaspine B in small experimental animals as well as in vivo pharmacokinetic-pharmacodynamic correlation studies.

Feasibility study of CdZnTe and CdZnTeSe based high energy X-ray detector using linear accelerator

  • Beomjun Park;Juyoung Ko;Jangwon Byun;Byungdo Park ;Man-Jong Lee ;Jeongho Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2797-2801
    • /
    • 2023
  • CdZnTeSe (CZTS) has attracted attention for applications in X- and gamma-ray detectors owing to its improved properties compared to those of CdZnTe (CZT). In this study, we grew and processed single crystals of CZT and CZTS using the Bridgeman method to confirm the feasibility of using a dosimeter for high-energy X-rays in radiotherapy. We evaluated their linearity and precision using the coefficient of determination (R2) and relative standard deviation (RSD). CZTS showed sufficient RSD values lower than 1.5% of the standard for X-ray dosimetry, whereas CZT's RSD values increased dramatically under some conditions. CZTS exhibited an R2 value of 0.9968 at 500 V/cm, whereas CZT has an R2 value of 0.9373 under the same conditions. The X-ray response of CZTS maintains its pulse shape at various dose rates, and its properties are improved by adding selenium to the CdTe matrix to lower the defect density and sub-grain boundaries. Thus, we validated that CZTS shows a better response than CZT to high-energy X-rays used for radiotherapy. Further, the applicability of an onboard imager, a high-energy X-ray (>6 MV) image, is presented. The proposed methodology and results can guide future advances in X-ray dose detection.