• Title/Summary/Keyword: % RSD

Search Result 528, Processing Time 0.038 seconds

Method Development for Determination of Trichothecene Mycotoxins in Nuts by LC-MS/MS (LC-MS/MS를 이용한 견과류 중 트리코테센계 곰팡이 독소 10종 동시분석법 개발)

  • Kim, Dan-Bi;Park, Ji-Su;Yoo, Mi-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.5
    • /
    • pp.354-360
    • /
    • 2018
  • This study presents a method validation for extraction and quantitative analysis of trichothecene mycotoxins in nuts based on quick, easy, cheap, effective, rugged, and safe (QuEChERS) approach for extraction and enhanced matrix removal (EMR)-lipid-disperive-SPE (d-SPE) cleanup method, with detection and quantification by high-performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) in positive- and negative-ion modes. Linearity, precision, and accuracy were validated for LC-MS/MS methods. Results obtained with LC-MS/MS were linear, with correlation coefficient ($R^2$) of 0.998. Limits of detection and quantification for mycotoxins were $0.41-3.57{\mu}g/kg$ and $1.23-10.82{\mu}g/kg$, respectively. Intra- and inter-day precisions (RSD, %) were 0.40-8.44% and 1.93-12.46%, respectively. Results indicated to be rapidly and accurately identifying trichothecene mycotoxins and may be used as a suitable safety management method for nuts and nuts related commodities.

Extraction and Preprocessing Methods for Ginsenosides Analysis of Panax ginseng C.A. Mayer (인삼의 진세노사이드 분석을 위한 추출 및 전처리법)

  • Kim, Geum-Soog;Hyun, Dong-Yun;Kim, Young-Ock;Lee, Sung-Woo;Kim, Young-Chang;Lee, Seung-Eun;Son, Yeong-Deck;Lee, Min-Jeong;Park, Chung-Berm;Park, Ho-Ki;Cha, Seon-Woo;Song, Kyung-Sik
    • Korean Journal of Medicinal Crop Science
    • /
    • v.16 no.6
    • /
    • pp.446-454
    • /
    • 2008
  • An advanced extraction method by ultrasonic extraction with applied solid phase extraction (SPE) has been developed for the determination of simultaneous eight major ginsenosides, namely ginsenosides Rg1, Re, Rf, Rb1, Rg2, Rc, Rb2, and Rd in the root of Panax ginseng. Four extraction methods including n-BuOH reflux extraction (Method A), 70% EtOH reflux extraction (Method B), 50% MeOH reflux extraction with SPE (Method C), and 50% MeOH ultrasonication with SPE clean-up process (Method D) were investigated for the determination of eight major ginsenosides. Total contents of ginsenosides were highest by extraction of Method C as $2.408{\pm}0.011%$. However, Method D was evaluated as relatively simpler and more efficient method due to short extraction time, small solvent consumption and less expensive, compared to conservative reflux method. Ginsenosides were also satisfactorily separated with good resolution and the accuracy range was between 1.05 and 4.06% as relative standard deviation (RSD) by Method D. SPE condition and HPLC condition were further optimized for determination of eight major ginsenosides by the ultrasonic extraction method. Conclusively, ultrasonic extraction of 2 g sample of ginseng using ultrasonic bath and 1 loading for SPE was evaluated as proper condition for extraction of ginseng.

A Study on Standardization of Shinbaro Pharmacopuncture Using Herbal Medicines Identification Test and HPLC-DAD (신바로 약침의 한약재 확인시험 및 HPLC-DAD를 통한 표준화 연구)

  • Lee, Jin Ho;Kim, Min Jeong;Lee, Jae Woong;Kim, Me Riong;Lee, In Hee;Kim, Eun Jee
    • Journal of Acupuncture Research
    • /
    • v.32 no.2
    • /
    • pp.1-9
    • /
    • 2015
  • Objectives : The present study was an evaluation and standardization of herbal components in order to establish the efficacy and safety of Shinbaro pharmacopuncture. Methods : Among the raw materials of Shinbaro pharmacopuncture, the components Cibotii Rhizoma, Eucommiae Cortex, and Ledebouriellae Radix were assessed through ingredient verification experiments using thin-layer chromatography(TLC) and ultraviolet rays(UV) lamps. In addition, we standardized Acanthopanacis Cortex and Achyranthis Radix through validation using high performance liquid chromatograph-diode array detector(HPLC-DAD). Results : As result appeared a blue-white fluorescence under ultraviolet rays; changed to dark green after adding 1 % ferric chloride solution(due to Cibotii Rhizoma), and presented a yellow-green fluorescence when mixed with an ethyl ether under UV lamps by way of the ethyl ether layer, confirming Eucommiae Cortex. Ledebouriellae Radix was confirmed as dark brown spots at Rf values of 0.56 and 0.71 using TLC. Additionally, Acanthopanacis Cortex and Achyranthis Radix HPLC test results showed that linearity was $R^2{\geq}0.99$, and detection limit and quantitation limit were 0.23 to $1.29{\mu}g/mL$, and 0.71 to $3.90{\mu}g/mL$, respectively. Furthermore, precision and accuracy were confirmed to have relative standard deviation(RSD) values of 0.10 to 1.89 % and 96.19 to 103.72 %, respectively. Shinbaro pharmacopuncture did not have any overlapping or interference from other peaks in detection under the abovementioned analysis conditions. Conclusions : In conclusion, we confirmed that maintenance of Shinbaro pharmacopuncture validity was possible by means of quality control of Cibotii Rhizoma, Eucommiae Cortex, and Ledebouriellae Radix through ingredient identification and Acanthopanacis Cortex and Achyranthis Radix through high performance liquid chromatograph(HPLC) analysis. Further, we hope to contribute to the development strategy of herbal industry acupuncture.

Pattern Recognition of the Herbal Drug, Magnoliae Flos According to their Essential Oil Components

  • Jeong, Eun-Sook;Choi, Kyu-Yeol;Kim, Sun-Chun;Son, In-Seop;Cho, Hwang-Eui;Ahn, Su-Youn;Woo, Mi-Hee;Hong, Jin-Tae;Moon, Dong-Cheul
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1121-1126
    • /
    • 2009
  • This paper describes a pattern recognition method of Magnoliae flos based on a gas chromatographic/mass spectrometric (GC/MS) analysis of the essential oil components. The botanical drug is mainly comprised of the four magnolia species (M. denudata, M. biondii, M. kobus, and M. liliflora) in Korea, although some other species are also being dealt with the drug. The GC/MS separation of the volatile components, which was extracted by the simultaneous distillation and extraction (SDE), was performed on a carbowax column (supelcowax 10; 30 m{\time}0.25 mm{\time}0.25{\mu}m$) using temperature programming. Variance in the retention times for all peaks of interests was within RSD 2% for repeated analyses (n = 9). Of the 74 essential oil components identified from the magnolia species, approximately 10 major components, which is $\alpha$-pinene, $\beta$-pinene, sabinene, myrcene, d-limonene, eucarlyptol (1,8-cineol), $\gamma$-terpinene, p-cymene, linalool, $\alpha$-terpineol, were commonly present in the four species. For statistical analysis, the original dataset was reduced to the 13 variables by Fisher criterion and factor analysis (FA). The essential oil patterns were processed by means of the multivariate statistical analysis including hierarchical cluster analysis (HCA), principal component analysis (PCA) and discriminant analysis (DA). All samples were divided into four groups with three principal components by PCA and according to the plant origins by HCA. Thirty-three samples (23 training sets and 10 test samples to be assessed) were correctly classified into the four groups predicted by PCA. This method would provide a practical strategy for assessing the authenticity or quality of the well-known herbal drug, Magnoliae flos.

Analytical Method Validation of Quercetin in Changnyeong Onion Extract as a Functional Ingredient for Functional Health Food (건강기능식품 기능성원료로서 창녕양파추출액의 지표성분 Quercetin 분석법)

  • Jeon, Seon-Young;Jeong, Eun-Jeong;Baek, Jeong-Hwa;Cha, Yong-Jun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.4
    • /
    • pp.565-569
    • /
    • 2011
  • Validation of quercetin as a marker compound in the standardization of Changnyeong onion extract developed for functional health food was attempted by analytical method. The specificity was satisfied with retention time and photo diode array (PDA) spectrum by analysis of quercetin using HPLC and comparison with standard compound. It showed a high linearity in the calibration curve as coefficient of correlation ($R^2$) of 0.9986, and the limit of detection (LOD) and limit of quantitation (LOQ) were 0.2 mg/L and 0.5 mg/L, respectively. Recovery rate test with quercetin concentration of 0.05, 0.075 and 0.1 mg/mL was revealed in the high range of 82.36~95.26%, 82.70~98.24% and 87.91~95.11%, respectively. The intra-day and inter-day precision in quercetin for Changnyeong onion extracts was 0.10~3.28% and 0.96~5.79%, respectively. Therefore, application of quercetin was validated in analytical method as a marker compound in Changnyeong onion extracts.

Analysis of Flumeqnine in Meats (식육 중 항생제 flumequine의 분석)

  • Kuk, Ju-Hee;Ko, Yong-Seok;Kim, Yong-Hoon;Yoon, Chang-Yong;Sun, Nam-Kyu;Kim, Eun-Jung;Seo, Jee-Woo;Park, Ji-Won;Kang, Kil-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.1
    • /
    • pp.7-10
    • /
    • 2009
  • An analytical method for the determination of flumequine in meats was developed and validated using high-performance liquid chromatography with fluorescence detection. The samples were mixed with sodium sulfate and extracted with ethyl acetate. After clean-up, the residues were dissolved in mobile phase. The calibration curves showed high linearity ($r^2$=0.9979) within the concentration range of 0.1-1.0 mg/kg. The limit of detection and limit of quantification were validated at 0.005 and 0.017 mg/kg, respectively. The recoveries in fortified meats ranged from 90.8 to 101.1%. The method was then validated in correspondence with the CODEX guidelines for flumequine residue in meats. Herein we monitored 150 samples of meats that were purchased in Korea (Seoul, Busan, Daegu, Daejeon, and Gwangju). Among the tested samples, flumequine was detected in 1 of beef and 1 of pork at levels in the range of 0.048-0.080 mg/kg. Overall, the flumequine residues in the tested samples were within the Maximun residue limit.

Determination of Trace-Level Perchlorate by IC-MS/MS and Distribution in the Han River (IC-MS/MS를 이용한 수중의 과염소산이온 분석방법 최적화 및 한강수계내 분포조사)

  • Kim, Hyun-Hee;Han, Ihn-Sup;Jeong, Gwan-Jo;Park, Hyeon;Han, Sun-Hee;Cho, Wan-Seon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.349-356
    • /
    • 2010
  • Ion chromatography (IC) coupled with conductivity detector (CD) is a common system for the determination of perchlorate in water samples. Although the IC method with CD has been widely used for the determination of trace level perchlorate ion in water, sensitivity decreases dramatically as the complexity of the matrices increases. Here we proposed the application of ion chromatography coupled with mass spectrometry (IC-MS/MS) to significantly improve selectivity of perchlorate. The mean recovery of the method was 104.4 ${\pm}$ 5.7% and the relative standard deviation (RSD%) was 1.9 ${\pm}$ 1.3%. The alculated method detection limit (MDL) was 0.0207 ${\pm}$ 0.0099 ${\mu}g/L$. The concentrations of perchlorate were minimum <0.1 ${\mu}g/L$ and maximum 18.3 ${\mu}g/L$ in source water (Namhan, Bukhan and Han River). Hongreung showed higher concentrations ($1^{st}$-14.3 ${\mu}g/L$, $2^{st}$-18.3 ${\mu}g/L$) than the other places. And the concentrations of perchlorate were 0.18~0.34 ${\mu}g/L$ in the samples taken from the six water treatment plants and six intake stations in Seoul.

Development of HPLC-UV method for detection and quantification of seven organic acids in animal feed (사료 중 유기산 7종 동시분석법 개발 및 유통 사료의 모니터링)

  • Kim, Jin kug;Lee, Mi Jin;Lee, Ye Ji;Kim, Hye Jin;Jeong, Min Hee;Kim, Ho Jin
    • Analytical Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.202-208
    • /
    • 2016
  • 본 연구에서는 사료 첨가제로 이용되고 있는 유기산 7종(formic acid, malic acid, lactic acid, acetic acid, citric acid, fumaric acid, propionic acid)의 동시분석법 개발을 위한 연구를 실시하였다. 7종의 화합물은 표준물질의 Retention time과 UV spectra를 통해 구별하였고, 분석법 검증은 직선성, 민감성, 선택성, 정확성, 정밀성을 통하여 검증하였다. 그 결과로 LOD와 LOQ의 범위가 각각 43~26,755 μg/kg, 12-8,026 μg/kg으로 설정하였고, 평균 회수율이 79.3~95.2%로 우수하게 보였으며, intra-day, inter-day에 대한 전반적인 상대 표준 편차(%RSD)는 3.2% 미만으로 나타났다. 이와 같이 검증된 자료를 통해 유기산의 동시분석에 대한 직선성, 민감성, 선택성, 정확성 및 정밀성을 확인하였고, 높은 수준을 나타냄을 알 수 있었다. 이를 바탕으로 유기산이 검출되는 단미사료 46 가지를 분석에 적용하여 진행하였고, 정량과 동시분석 검출을 위한 방법은 RP-HPLC/UV 검출기를 이용하여 성공적으로 개발되었다. 따라서 본 연구결과를 바탕으로 하여 사료 중의 유기산의 분석이 신속하고 정확해졌을 뿐 아니라, 다른 종류의 사료 또한 이를 적용하여 효율적으로 이용할 수 있을 것으로 판단된다.

Development and validation of analytical methods for pyrifluquinazon residues determination on agricultural commodities by HPLC-UVD (HPLC-UVD를 이용한 농산물 중 pyrifluquinazon 잔류시험법 개발 및 검증)

  • Do, Jung-Ah;Kwon, Ji-Eun;Kim, Mi-Ra;Lee, Eun-Mi;Kuk, Ju-Hee;Cho, Yoon-Jae;Chang, Moon-Ik;Kwon, Kisung;Oh, Jae-Ho
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.174-181
    • /
    • 2013
  • Pyrifluquinazon is classified with a quinazoline insecticide that regulates food intake by controling the feeding behavior acting on the endocrine or nervous system of pests such as aphids and white fly. To keep safety on pyrifluquinazon residues in agricultural commodities a simple, accurate and rapid analytical method was developed and validated using high performance liquid chromatograph (HPLC-UVD). The pyrifluquinazon residues acidified with 1% formic acid in samples were extracted with acetonitrile and partitioned with hexane subsequently to dichloromethane then purified with silica solid phase extraction (SPE) cartridge. The purified samples were detected using HPLC-UVD. The method was validated using apple and pear spiked with pyrifluquinazon at 0.02, 0.05 and 0.1 mg/kg and hulled rice, pepper, soybean at 0.05 and 0.1 mg/kg. Average recoveries were 70.5~107.9% with relative standard deviation less than 10%. The result of recoveries and overall coefficient of variation of a laboratory results in Gwangju regional FDA and Daejeon regional FDA was followed with Codex guideline (CODEX CAC/GL 40). This method is appropriated at pyrifluquinazon residues determination and will be used as official method of analysis.

Development of Disposable Immunosensors for Rapid Determination of Sildenafil and Vardenafil in Functional Foods

  • Vijayaraj, Kathiresan;Lee, Jun Hyuck;Kim, Hyung Sik;Chang, Seung-Cheol
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.83-88
    • /
    • 2017
  • We introduced disposable amperometric immunosensors for the detection of Sildenafil and Vardenafil (SDF/VDF) based on screen printed carbon electrodes. The developed immunosensors were used as a non-competitive sandwich-type enzyme immunoassay with a horseradish peroxidase label. The sensors were constructed on screen printed carbon electrodes by the simple electrochemical deposition of a reduced graphene oxide and chitosan (ErGO-CS) composite. To evaluate the sensing chemistry and optimize the sensor characteristics, a series of electrochemical experiments were carried out including electrochemical impedance spectroscopy, cyclic voltammetry and amperometry. The sensors showed a linear response to SDF/VDF concentrations in a range from 100 pg/mL to 300 ng/mL. The lower detection limit was calculated to be 55 pg/mL, the sensitivity was calculated to be $1.02{\mu}Ang/mL/cm^2$, and the sensor performance exhibited good reproducibility with a relative standard deviation (RSD) of 7.1%. The proposed sensing chemistry strategy and the sensor format can be used as a simple, cost-effective, and feasible method for the in-field analysis of SDF/VDF in functional or health supplement food samples.