• Title/Summary/Keyword: $m_v$ method

Search Result 2,701, Processing Time 0.038 seconds

Selective Oxidation of 2,6-di-tert-butylphenol and Electrochemical Properties by Oxygen Adducted Tetradentate Schiff Base Cobalt (Ⅲ) Activated Catalysts in Aprotic Solvents (비수용매에서 산소 첨가된 네자리 Schiff Base Cobalt(Ⅲ) 활성 촉매들에 의한 2,6-di-tert-butylphenol의 선택 산화와 전기화학적 성질)

  • Jo, Gi Hyeong;Choe, Yong Guk;Ham, Hui Seok;Kim, Sang Bok;Seo, Seong Seop
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.569-581
    • /
    • 1990
  • It is generated in DMF by activated catalysts of superoxo cobalt(III) complex, such as [Co(III)(Schiff base)(L)]O$_2$ (Schiff base; SED, SOPD and o-BSDT, L; DMF and Py) which mole ratio of oxygen to metal is 1:1 that oxidation major product of 2,6-di-tert-butylphenol by homogeneous oxidatve catalysts of oxygen adducted tetradentate Schiff base cobalt(III) is 2,6-ditert-butylbenzoquinone (BQ). And oxidation product of 3,3',5,5'-tetra-tert-butyldiphenoquinone (DPQ) is generated by activated catalysts such as $\mu$-peroxo cobalt(III) complex; $[Co(III)(SND)(L)]_2$$O_2$ (L; DMF and Py) which mole ratio of oxygen to metal is 1:2. It is difficult to identify these homogeneous activated catalysts such as superoxo and $\mu$-peroxo cobalt(III) complexes in DMF and DMSO solvents. But we can identify by P.V.T method of the oxygen absorption in pyridine solvent and by the reduction process occurred to four steps including prewave of O$_2$- in 1:1 oxygen adducted superoxo cobalt(III) complexes and three steps not including prewave of O$_2$- in 1:2 oxygen adducted $\mu$-peroxo cobalt(III) complexes by the cyclic voltammetry with glassy carbon electrode in 0.1 M TEAP as supporting electrolyte solutidn.

  • PDF

The Grounding Method Application of Power Plant Simulator (발전소 시뮬레이션시스템 접지방식 연구를 위한 타시스템 접지방식 분석)

  • 오영일
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.70-74
    • /
    • 1999
  • 발전소 시뮬레이션 시스템 기술은 종합적인 지식을 바탕으로 자료수집 및 분석, 소프트웨어 개발 환경, 수학적 모델, 전산기 구성, 각종 계기류 설계 및 구매 장착 등의 노하우를 알아야만 제작할 수 있는 종합적인 기술이다. 또 지시기반의 기술이며 부가가치가 높은 기술이기 때문에 선진 각국에서는 계측제어 시스템의 기술개발 및 시장 확대를 위하여 힘을 쓰는 동시에 타국으로의 기술정보 유출을 경계하는데 신경을 곤두세우고 있다. 현재 복잡화되어 가고 있는 산업 사회의 전력 수요에 대한 대폭적인 증가 추세에 따라 발전소에서는 보다 효율적이며 합리적이고 경제적인 전력 공급을 위해서 전력 생산에 대한 신뢰성 향상 및 안정성 확보는 물론, 효율성 높은 운전이 절실히 요구되고 있다. 한편, 국내의 시뮬레이션 시스템 분야 기술은 아직도 완벽한 수준에는 미치지 못하며, 이 분야의 기술력 확보 및 신기술 개발은 향후 미래의 모든 시스템산업의 성쇄를 판가름하는 아주 중요한 척도가 될 것이다. 이 중에서 접지 분야는 고전압 혼촉에 의한 저압측 선로의 전압상승 방지, 모선(Bus)이나 전력 기기의 절연보호 및 회로전압의 안정등으로 시스템 성능을 한층 증가 시켜줄 뿐아니라 기기의 오동작이나 낙뇌등으로 인명피해 발생을 없애주는 아주 중요한 분야임에도 불구하고 이 분야의 국내 관련법규등이 미비한 사항이다. 그래서 발전소 분산제어 시스템분야의 장기간 신뢰성 및 안정성을 가지고 있고, 국내에서 많이 사용하는 미국 Bailey의 infi-90 및 독일 ABB의 Procontrol-P를 비교 분석하여 발전소 시뮬레이션 시스템의 접지에 응용 하고져 한다.상호 발생기를 이용한 다양한 시스템 검증 및 분석에 이용할 수 있을 것이다. 본 논문은 가상호 발생기의 구조와 최대 용량 시험 방법을 소개하고, 더 나아가 호 Traffic에 대한 최대 용량 시험뿐 아니라 QoS를 향상시키기 위한 교환 시스템의 제반 성능 시험 및 분석에 이를 이용하기 위해 개선이 필요함을 서술하고자 한다.textrm{m}$~3.4$\mu\textrm{m}$ 범위에서의 투과 및 흡수 스펙트럼을 측정하였다. 결정 성장 결과 B3+, Er3+, Cr3+ 이온은 Ti4+ 이온과 이온의 크기 차이가 심하여 결정의 정상적인 성장을 방해하는 물성을 나타냈고, V5+, Cr3+ 이온은 흑색의 결정, Fe3+ 이온은 적갈색의 결정으로 성장되었다. Al3+, Zr4+, Al3+의 순서로 투과도가 높아지는 것이 관찰되었다. 불순이온의 농도에 따른 영향으로서 Al3+ 이온의 경우 주입농도가 높아질수록 low angle boundary와 oxygen deficiency가 감소하였고, 투과율은 조금 감소하거나 큰 차이가 없는 것으로 나타났다. 반면에 Cr3+ 이온을 주입한 경우 0.003 atomic%에서 최적의 물성을 보였으며, 주입농도가 높아질수록 결정성장이 어려워지고 광의 투과도가 급격히 저하되었다.은 1.3을 나타내었다.로 보인다.하면 수평축과 수직축의 분산 장벽의 비에 따라 cluster의 두께비가 달라지는 성장을 볼 수 있었고, 한 축 방향으로의 팔 넓이는 fcc(100) 표면의 경우 동일한 Ed+Ep값에 대응하는 팔 넓이와 거의 동일한 결과가 나타나는 것을 볼 수 있다. 따라서 이러한 비대칭적인

  • PDF

Luminescence Characteristics of Blue Phosphor and Fabrication of a UV-based White LED (UV 기반 백색 LED용 청색 형광체의 발광특성 및 백색 LED 제조)

  • Jung, Hyungsik;Park, Seongwoo;Kim, Taehoon;Kim, Jongsu
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.4
    • /
    • pp.216-220
    • /
    • 2014
  • We have synthesized a $CaMgSi_2O_6:Eu^{2+}$ blue phosphor via a solid-state reaction method. The $CaMgSi_2O_6:Eu^{2+}$ phosphor has monoclinic structure with a space group of C2/c (15), and an emission band peaking at 450 nm (blue) due to the $4f^7-4f^65d$ transition of the $Eu^{2+}ion$. The emission intensity at $100^{\circ}C$ is 54% of the value at room temperature. A white LED was fabricated by integrating a UV LED (400 nm) with our blue phosphor plus two commercial green and red phosphors. The white LED shows a color temperature of 3500 K with a color rendering index of 87 (x = 0.3936, y = 0.3605), and a luminous efficiency of 18 lm/W. The white LED shows a luminance maintenance of 97% after operation at 350 mA for 400 hours at $85^{\circ}C$.

The Effect of Electrode Pattern on the Humidity-sensing Properties of the Resistive Humidity Sensor Based on All-printing Process (인쇄공정으로 제조된 저항형 습도센서의 감습특성에 대한 전극패턴의 영향 연구)

  • Ahn, Hee-Yong;Gong, Myoung-Seon
    • Polymer(Korea)
    • /
    • v.36 no.2
    • /
    • pp.169-176
    • /
    • 2012
  • Based on our experience in developing resistive humidity sensor, interdigital gold electrodes with different fingers and gaps have been fabricated on a glass epoxy (GE) substrate using screen printing techniques. The basic structure of the electrode consisted of a 3-, 4- and 5-fingers with gaps of 310 and 460 ${\mu}m$. Gold electrode/GE was prepared by first printing silver nanopaste, followed by consecutive electroless plating of Cu, Ni and then Au. Copolymer of [2-(methacryloyloxy)ethyl] dimethyl benzyl ammonium chloride (MDBAC) and methyl methacrylate (MMA) was used as a humidity-sensing polyelectrolyte, which was fabricated by a screen printing method on the Au electrode/GE substrate. The flexible humidity sensor showed acceptable linearity between logarithmic impedance and relative humidity in the range of 20-95%RH, low hysteresis of 1.5%RH, good response and recovery time of 75 sec at 1 V, 1 kHz, and $25^{\circ}C$. Electrode construction had a significant influence on the humidity-sensing characteristics of polymeric humidity sensors. The activation energy between electrode and ion conducting polyelectrolyte plays an important role in explaining the differences of humidity sensing characteristics such as temperature dependence, sensitivity, linearity and hysteresis.

Deposition of thick free-standing diamond wafer by multi(7)-cathode DC PACVD method

  • 이재갑;이욱성;백영준;은광용;채희백;박종완
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.214-214
    • /
    • 1999
  • 다이아몬드를 반도체용 열방산용기판 등으로 사용하기 위해서는 수백 $\mu\textrm{m}$ 두께의 대면적 웨이퍼가 요구된다. 이를 위해서 DC are jet CVD, MW PACVD, DC PACVD 등이 개발되어, 현재 4"에서 8"까지의 많은 문제를 일으키고 있다. 본 연구에서는 multi-cathode DC PACVD법에 의한 4" 다이아몬드 웨이퍼의 합성과 합성된 막의 특성변화에 대한 연구를 수행하였다. 또한, 웨이퍼의 휨과 crack 발생거동과 대한 고찰을 통래 휨과 crack이 없는 웨이퍼의 제작방법을 고안하였다. 사용된 음극의 수는 일곱 개이며, 투입된 power는 각 음극 당 약 2.5kW(4.1 A-600V)이었다. 사용된 기판의 크기는 직경 4"이었다. 합성압력은 100Torr, 가스유량은 150sccm, 증착온도는 125$0^{\circ}C$~131$0^{\circ}C$, 수소가스네 메탄조성은 5%~8%이었다. 합성 중 막에 인가되는 응력은 합성 중 증착온도의 변화에 의해 제어하였다. 막의 결정도는 Raman spectroscopy 및 열전도도를 측정을 통해 분석하였다. 성장속도 및 다이아몬드 peak의 반가폭은 메탄조성 증가(5%~8%)에 따라 증가하여 각각 6.6~10.5$\mu\textrm{m}$/h 및 3.8~5.2 cm-1의 분포를 보였다. 6%CH4 및 7%CH4에서 합성된 웨이퍼에서 측정된 막의 열전도도는 11W/cmK~13W/cmK 정도로 높게 나타났다. 막두께의 uniformity는 최대 3.5%로 매우 균일하였다. 막에 인가되는 응력의 제어로 직경 4"k 합성면적에서 두께 1mm 이상의 균열 및 휨이 없는 다이아몬드 자유막 웨이퍼를 합성할 수 있었다.다이아몬드 자유막 웨이퍼를 합성할 수 있었다.active ion에 의해 sputtering 이 된다. 이때 plasma 처리기의 polymer 기판 후면에 magnet를 설치하여 높은 ionization을 발생시켜 처리 효과를 한층 높여 주었다. 이 plasma 처리는 표면 청정화, 표면 etching 이 동시에 행하는 것과 함께 장시간 처리에 의해 표면에서는 미세한 과, C=C기, -C-O-의 극성기의 도입에 의한 표면 개량이 된다는 것을 관찰할 수 있다. OPP polymer 표면을 Ar 100%로 plasma 처리한 경우 C-O, C=O 등의 carbonyl가 발생됨을 알 수 있었다. C-O, C=O 등의 carbynyl polor group이 도입됨에 따라 sputter된 Al의 접착력이 향상됨을 알 수 있으며, TEM 관찰 결과 grain size도 상당히 작아짐을 알 수 있었다.onte-Carlo 방법으로 처리하였다. 정지기장해석의 경우 상용 S/W인 Vector Fields를 사용하였다. 이를 통해 sputter 내 플라즈마 특성, target으로 입사하는 이온에너지 및 각 분포, 이들이 target erosion 형상에 미치는 영향을 살펴보았다. 또한 이들 결과로부터 간단한 sputtering 모델을 사용하여 target으로부터 sputter된 입자들이 substrate에 부착되는 현상을 Monte-Carlo 방법으로 추적하여 성막특성도 살펴보았다.다.다양한 기능을 가진 신소재 제조에 있다. 또한 경제적인 측면에서도 고부가 가치의 제품 개발에 따른 새로운 수요 창출과 수익률 향상, 기존의 기능성 안료를 나노(nano)화하여 나노 입자를 제조, 기존의 기능성 안료에 대한 비용 절감 효과등을 유도 할 수 있다. 역시 기술적인 측면에서도 특수소재 개발에 있어 최적의 나노 입자 제어기술 개발 및 나노입자를 기능성 소재로 사용하여 새로운 제품의 제조와 고압 기상

  • PDF

Preparation of Lipid Nanoparticles Containing Paclitaxel and their in vitro Gastrointestinal Stability (파클리탁셀을 함유한 지질나노입자의 제조와 인공 소화액에서의 안정성 평가)

  • Kim, Eun-Hye;Lee, Jung-Eun;Lim, Deok-Hwi;Jung, Suk-Hyun;Seong, Ha-Soo;Park, Eun-Seok;Shin, Byung-Cheol
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.2
    • /
    • pp.127-134
    • /
    • 2008
  • Peroral administration is the most convenient one for the administration of pharmaceutically active compounds. Most of poorly water-soluble drugs administered via the oral route, however, remain poorly available due to their precipitation in the gastrointestinal (GI) tract and low permeability through intestinal mucosa. In this study, one of drug delivery carriers, lipid nanoparticles (LNPs) were designed in order to reduce side effects and improve solubility and stability in GI tract of the poorly water soluble drugs. However, plain LNPs are generally unstable in the GI tract and susceptible to the action of acids, bile salts and enzymes. Accordingly, the surface of LNPs was modified with polyethylene glycol (PEG) for the purpose of improving solubility and GI stability of paclitaxel (PTX) in vitro. PEG-modified LNPs containing PTX was prepared by spontaneous emulsification and solvent evaporation (SESE) method and characterized for mean particle diameter, entrapping efficiency, zeta potential value and in vitro GI stability. Mean particle diameter and zeta potential value of PEG-modified LNP containing PTX showed approximately 86.9 nm and -22.9 mV, respectively. PTX entrapping efficiency was about 70.5% determined by UV/VIS spectrophotometer. Futhermore, change of particle diameter of PTX-loaded PEG-LNPs in simulated GI fluids and bile fluid was evaluated as a criteria of GI stability. Particle diameter of PTX-loaded PEG-LNPs were preserved under 200 nm for 6 hrs in simulated GI fluids and bile fluid at $37^{\circ}C$ when DSPE-mPEG2000 was added to formulation of LNPs above 4 mole ratio. As a result, PEG-modified LNPs improved stability of plain LNPs that would aggregate in simulated GI fluids and bile solution. These results indicate that LNPs modified with biocompatible and nontoxic polymer such as PEG might be useful for enhancement of GI stability of poorly water-soluble drugs and they might affect PTX absorption affirmatively in gastrointestinal mucosa.

필름 스피커 적용을 위한 PZT/polymer 복합체의 후막 제조 및 압전 특성 평가

  • Son, Yong-Ho;Eo, Sun-Cheol;Kim, Seong-Jin;Gwon, Seong-Yeol;Gwon, Sun-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.346-346
    • /
    • 2007
  • 압전세라믹 재료는 현재 압전 변압기, actuator, transducer, sensor, speaker 등에 광범위하게 이용이 되고 있다. 이 중에서 압전세라믹 소결체를 이용한 스피커의 제조는 가공이 까다롭고, 대형의 크기로 제작 시 소자가 깨지는 등의 많은 제약을 받고 있으며, 저음 특성이 떨어져 응용 범위가 한정되어 있다. 따라서 최근에는 이러한 단점을 극복하기 위하여 세라믹/고분자 복합체를 이용한 필름 스피커를 제작하고자 시도하고 있다. 이러한 세라믹/고분자 0-3형 압전 복합체를 이용할 경우, 제품의 경량화를 실현할 수 있고, 크기나 환경의 영향을 거의 받지 않으므로, 고기능성 스피커로의 응용에 적합할 것으로 보인다. 따라서 본 연구에서는 PZT계의 세라믹와 PVDF, PVDF-TrFE, Polyester, acrylic resin 등의 여러 고분자 물질과의 복합체를 제조하여 압전특성을 평가하였다. 본 실험은 먼저 $(Pb_{1-a-b}Ba_aCd_b)(Zr_xTi_{1-x})_{1-c-d}(Ni_{1/3}Nb_{2/3})_c(Zn_{1/3}Nb_{2/3})_dO_3$ (이하 PZT라 표기)의 최적화 조성을 선택하여, $1050^{\circ}C$에서 소결된 분말을 48시간 ball milling방법 로 약 $1{\mu}m$ 크기로 분쇄하였다. 고분자 물질들은 알맞은 용제들을 선택하여 녹였다. 그 다음 소결된 PZT분말과 고분자를 50:50, 60:40, 65:35, 70:30등의 무게 분율로 혼합하고, 분산제, 소포제 등을 첨가하여 3단 roll mill을 이용하여 충분히 분산시켜 페이스트 (Paste)를 제조하였다. 제조된 페이스트를 ITO가 코팅된 PET필름 위에 스크린 프린팅 법을 사용하여 인쇄하여 $120^{\circ}C$에서 5분간 건조하였다. 코팅된 복합체의 두께는 약 $80{\mu}m$ 정도로 측정되었다. Ag 페이스트를 이용한 상부 전극 형성에도 스크린 프린팅 법을 적용하였다. 이를 $120^{\circ}C$에서 4 kV/mm의 DC 전계로 분극 공정을 수행한 후 전기적 특성을 평가하였다. 유전특성을 조사하기 위해서 LCR meter (EDC-1620)를 사용하였고, 시편의 결정구조는 XRD (Rigaku; D/MAX-2500H)을 통해 분석하였으며, 전자현미경(SEM)을 이용하여 미세구조를 분석하였다. 압전 전하상수$(d_{33})$ 값은 APC 8000 모델을 이용하여 측정하였다. PZT의 혼합비가 증가할수록 비유전율 및 압전 전하 상수 등의 전기적 특성이 증가되었다. 또 여러 고분자 물질 중에서 PVDF-TrFE 수지가 가장 우수한 특성을 보였다. 이는 PVDF-TrFE 수지가 압전성을 나타내기 때문인 것으로 판단되었다.

  • PDF

Performance Evaluation of a Portable GC for Real-time Monitoring of Volatile Organic Compounds (휘발성 유기화합물의 실시간 모니터링을 위한 휴대형 GC의 성능 평가)

  • You, Dong-Wook;Seon, Yeong-Sik;Oh, Jun-Sik;Yi, Bongyoon;Kim, Hyun Sik;Jung, Kwang-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.327-333
    • /
    • 2020
  • Performance of a portable GC that can be utilized for the real time determination of volatile organic compounds in air was evaluated. It employs purified/compressed ambient air as the carrier gas eliminating the need for high pressure gas tanks. The compact system with dimensions of 35 × 26 × 15 ㎤ and weight of 5 kg is powered by either a 24 V DC external adapter or battery pack. Chromatograms of the mixture sample including benzene, toluene, ethylbenzene, and oxylene at concentrations of 1 ppmv and 20 ppmv represent a good reproducibility: 3.79% and 0.48% relative standard deviations (RSDs) for peak area variations; 0.40% and 0.08% RSDs for retention times. The method detection limit was 0.09 ppmv. A 30 m long, 0.28 mm I.D. column operated at an optimal condition yielded a peak capacity of 61 with good resolution for a 10 min isothermal analysis. The relative standard deviations (RSD) of the peak area variations and retention times during consecutive measurements over 27 h were less than 2.4%RSD and 0.5%RSD, respectively. Thus, this instrument makes it suitable for continuous and field analysis of low-concentration VOC mixtures in the indoor/outdoor environment as well as the spillage accident of hazardous chemicals.

The Flow-rate Measurements in a Multi-phase Flow Pipeline by Using a Clamp-on Sealed Radioisotope Cross Correlation Flowmeter (투과 감마선 계측신호의 Cross correlation 기법 적용에 의한 다중상 유체의 유량측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Lee, Na-Young;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.13-20
    • /
    • 2008
  • The flow rate measurements in a multi-phase flow pipeline were evaluated quantitatively by means of a clamp-on sealed radioisotope based on a cross correlation signal processing technique. The flow rates were calculated by a determination of the transit time between two sealed gamma sources by using a cross correlation function following FFT filtering, then corrected with vapor fraction in the pipeline which was measured by the ${\gamma}$-ray attenuation method. The pipeline model was manufactured by acrylic resin(ID. 8 cm, L=3.5 m, t=10 mm), and the multi-phase flow patterns were realized by an injection of compressed $N_2$ gas. Two sealed gamma sources of $^{137}Cs$ (E=0.662 MeV, ${\Gamma}$ $factor=0.326\;R{\cdot}h^{-1}{\cdot}m^2{\cdot}Ci^{-1}$) of 20 mCi and 17 mCi, and radiation detectors of $2"{\times}2"$ NaI(Tl) scintillation counter (Eberline, SP-3) were used for this study. Under the given conditions(the distance between two sources: 4D(D; inner diameter), N/S ratio: $0.12{\sim}0.15$, sampling time ${\Delta}t$: 4msec), the measured flow rates showed the maximum. relative error of 1.7 % when compared to the real ones through the vapor content corrections($6.1\;%{\sim}9.2\;%$). From a subsequent experiment, it was proven that the closer the distance between the two sealed sources is, the more precise the measured flow rates are. Provided additional studies related to the selection of radioisotopes their activity, and an optimization of the experimental geometry are carried out, it is anticipated that a radioisotope application for flow rate measurements can be used as an important tool for monitoring multi-phase facilities belonging to petrochemical and refinery industries and contributes economically in the light of maintenance and control of them.

Characterization of Physiological Properties in Vibrio fluvialis by the Deletion of Oligopeptide Permease (oppA) Gene (Vibrio fluvialis oligopeptide permease (oppA) 유전자 deletion에 의한 생리적 특성)

  • Ahn Sun Hee;Lee Eun Mi;Kim Dong Gyun;Hong Gyoung Eun;Park Eun Mi;Kong In Soo
    • Journal of Life Science
    • /
    • v.16 no.1
    • /
    • pp.131-135
    • /
    • 2006
  • Oligopeptide is known to be an essential nitrogen nutrient for bacterial growth. Oligopeptide can be transported into cytoplasm by a specific transport system, Opp system. Opp system is composed of five proteins, which are transcribed by an operon. These are responsible for oligopeptide binding protein (OppA), permease (OppB and OppC) and energy generation system (OppD and OppF), respectively. Previously, we isolated the opp operon from Vibrio fluvialis and constructed the oppA mutant by allelic exchange method. In this study, we investigated the growth pattern and biofilm production under the different growth condition. When the cells were cultivated using brain heart infusion(BHI) medium, the wild type was faster than the mutant in growth during the exponential phase. However, it showed that the growth pattern of two strains in M9 medium is very similar. The growth of wild type showed better than that of the mutant grown at pH 8. At pH 7, there was no an obvious difference in growth. After 5 mM $H_2O_2$ was treated to the cells $(OD_{600}=1.2)$, the cell survival was examined. The oppA mutation did not affect in survivability. In the presence of $10{\mu}g/ml$ polymyxin B, the biofilm production of the oppA mutant was higher than that of the wild type.