• 제목/요약/키워드: $k-{\epsilon}$ model

검색결과 260건 처리시간 0.025초

하나로 유동모의 설비의 유체순환계통 해석 (The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

원심다익송풍기의 고효율 설계를 위한 수치최적설계 (Numerical Optimization of a Multi-blades Centrifugal Fan for High-efficiency Design)

  • 서성진;김광용
    • 한국유체기계학회 논문집
    • /
    • 제7권3호
    • /
    • pp.32-38
    • /
    • 2004
  • Shape of a multi-blades centrifugal fan is optimized by response surface method based on three-dimensional Navier-Stokes analysis. For numerical analysis, Reynolds-averaged Navier-Stokes equations with standard $k-{epsilon}$ turbulence model are transformed into non-orthogonal curvilinear coordinate system, and are discretized with finite volume approximations. Due to the large number of blades in this centrifugal fan, the flow inside of the fan is regarded as steady flow by introducing the impeller force models for economic calculations. Optimizations with and without constraints are carried out. Design variables, location of cur off, radius of cut off, expansion angle of scroll and width of impeller were selected to optimize the shapes of scroll and blades. Data points for response evaluations were selected by D-optimal design, and linear programming method was used for the optimization on the response surface. As a main result of the optimization, the efficiency was successfully improved. The correlation of efficiency with relative size of inactive zone at the exit of impeller is discussed as well as with average momentum fluxes in the scroll.

원심다익송풍기 유동의 삼차원 Navier-Stakes 해석 (Three-Dimensional Navier-Stokes Analysis of the Flow through A Multiblade Centrifugal Fan)

  • 서성진;첸시;김광용;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.42-48
    • /
    • 1998
  • Numerical study is presented for the analysis of three-dimensional incompressible turbulent flows in multiblade centrifugal fan. Reynolds-averaged Navier-Stokes equations with standard k - $\epsilon$ turbulence model are transformed to non-orthogonal curvilinear coordinates, and are discretized with finite volume approximations. Linear Upwind Differencing Scheme(LUDS) is used to approximate the convection terms in the governing equations. SIMPLEC algorithm is used as a velocity-pressure correction procedure. The computational area is divided into three blocks; core, impeller and scroll, which are linked by multi-block method. The flow inside of the fan is regarded as steady flow, and mathematical formula established from the cascade theory and empirical coefficient are employed to simulate tile flow through the impeller. From comparisons between the computational results and the experimental data, the validity of the mathematical formula for the blade forces was examined and good results were obtained qualitatively. Hence, we can get the flow characteristics of multi-blade centrifugal fan and it will be a corner stone of the development of the multiblade centrifugal fan.

  • PDF

응집효율 향상을 위한 수직형 교반기의 유동특성 연구 (A Study on the Flow Characteristics of Vertical Impeller to Improve Flocculation Efficiency)

  • 김진훈;박종호
    • 한국유체기계학회 논문집
    • /
    • 제8권3호
    • /
    • pp.33-41
    • /
    • 2005
  • The optimum condition is defined as one that best suits the purpose of flocculation; the number of small particles should decrease, while that of large particles should increase. The object of this research was to develop a new impeller and substitute for conventional flocculators. The flow characteristics of turbines and hydrofoil type flocculators in turbulent fluids were observed using a standard $k-{\epsilon}$ Model and a computational fluid dynamics (CFD) simulation program-FLUENT. The experiments were performed to compare PBT(Pitched Blade Turbine) flocculator with twisted hydrofoil type flocculators for velocity distribution, and floe formation at conventional water treatment plants in Korea. As a result of the CED solution, twisted hydrofoil types are similar to hydrofoil flocculators for flow characteristics without regard to the twisted angle, On the other hand, it was established that turbine flocculators are greater than hydrofoil flocculators with flow unevenness and dead zone formation. Twisted hydrofoil type-II (Angle $15{\sim}20^{\circ}$) is the most proper impeller for water flocculation from this point of view with a decreasing the dead zone, maintaining of the equivalent energy distribution and a drawing up of the sedimentation substance from the bottom of the flocculation basin.

유공성 수평격판을 가진 열원이 있는 밀폐공간내의 온도분포 특성 (Characteristices of Temperature Distribution in a Closed Space with Heat Source and Porous Horizontal Partition)

  • 박찬수;조대환;전철균
    • 한국해양공학회지
    • /
    • 제13권3B호
    • /
    • pp.29-37
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-${\epsilon}$ model was carried out. In the present study, the marine engine room is separated to two floors with porus horizontal partition and considered as a closed space with a heat source and forced ventilation ducts. The porosity of horizontal partition is found to be important. For the engine room with 2 supply ports & 2 exhaust ports, the increasing of the porosity of horizontal partition is effective to reduce the recirculation flow zone in the second floor. When the engine room is ventilated with three supply air ports & one exhaust port, the increasing of the porosity of horizontal partition is effective to reduce the recirculating flow zone in the exhaust air area, but there is a possibility of local extreme heating at the lower side of engine near bottom.

  • PDF

열전달 해석을 통한 스크롤 압축기 성능 개선 (Performance Improvement of a Scroll Compressor by Heat Transfer Analysis)

  • 홍상욱;류호선
    • 한국유체기계학회 논문집
    • /
    • 제3권4호
    • /
    • pp.22-29
    • /
    • 2000
  • Numerical analysis using three dimensional finite volume method for the discretization, adaptive grid method for the numerical accuracy, multiple rotating frame method for the rotating body and the standard $k-{\epsilon}$ model for the turbulent flow was performed to understand the heat transfer phenomena and to improve the efficiency of the scroll compressor. The temperature measurement was carried out under ARI condition. It was found that the fluid temperature in the compressor was predicted accurately while the temperature of the motor coil showed large discrepancy between the calculation and experiment due to the large anisotropy of the conductivity and non homogeneity. We found that the efficiency of the compressor depends on the inlet temperature of the compressing part and the flow pattern around the inlet region of the compressing part influences the inlet temperature due to high surface temperature of the main frame. The efficiency of the compressor using Coanda effect is higher than the previous one because the smooth suction at the inlet region of the compressing part leads to low heat transfer to the refrigerant of the compressor.

  • PDF

초청정 클린룸 난류유동장내에서의 오염입자 비정상 전파거동에 관한 연구 (Study on the Unsteady Contaminated Particle Transportation in the Flow Field for the Super Clean Room)

  • 오명도;임학규;배귀남
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.430-439
    • /
    • 1990
  • Steady state turbulent airflow and unsteady characteristics of generation, transportation, and recovery behavior of contaminate particles in the simplified 2 dimensional Vertical Laminar Flow (VLF) type clean room was numerically simulated using the low Reynolds number k-over bar.epsilon- turbulent model. Characteristics of airflow in VLF type clean room are greatly affected by the recirculation zone around working surface. The recirculation zone must be considered at the time of clean room design because the recirculation zone whose area increases with increment of inlet velocity exerts bad influence upon the performance of clean room in terms of particle contamination. The location of maximum particle concentration changes from the location of particle source to the recirculation zone, while averaged particle concentration is reduced exponentially with time. Recovery time of clean room with spontaneous particle generation source is inversely proportional to inlet velocity. We introduce nondimensionalized recovery time through the dimensional analysis, which can indicates the general performance of clean room with design structure change. It was identified that .tau. is independent of inlet velocity and background concentration. Therefore .tau. can be the simple factor to compare the different structure of clean room in terms of dynamic response to contamination and becomes larger with better structure of clean room.

분사를 수반하는 평씨일 내의 유동해석 (Flow Analysis of the Plain Seal with Injection)

  • 이관수;김우승;김기연;김창호
    • 대한기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.795-802
    • /
    • 1992
  • 본 연구에서는 일정한 각도의 분사를 갖는 평씨일(plain seal)에 대하여 각 인자들이 누수성능에 미치는 영향을 수치적으로 조사하였다. 인자들로는 축방향 레 이놀즈수, 축회전속도, 분사의 유입속도, 간극비, 분사의 위치 및 유입각 등이 고려되 었다.

Ahmed body 주위의 3차원 난류유동 해석-유한차분도식의 평가- (Simulation of Three-Dimensional Turbulent Flows around an Ahmed Body-Evaluation of Finite Differencing Schemes-)

  • 명현국;박희경;진은주
    • 대한기계학회논문집B
    • /
    • 제20권11호
    • /
    • pp.3589-3597
    • /
    • 1996
  • The Reynolds-averaged Navier-Stokes equations with the equations of the k-.epsilon. turbulence model are solved numerically in a general curvilinear system for a three-dimensional turbulent flow around an Ahmed body. The simulation is especially aimed at the evaluation of three finite differencing schemes for the convection term, which include the upwind differencing scheme(UDS), the second order upwind differencing scheme(SOU scheme) and the QUICK scheme. The drag coefficient, the velocity and pressure fields are found to be changed considerably with the adopted finite differencing schemes. It is clearly demonstrated that the large difference between computation and experiment in the drag coefficient is due to relatively high predicted values of pressure drag from both front part and vertical rear end base. The results also show that the simulation with the QUICK or SOU scheme predicts fairly well the flow field and gives more accurate drag coefficient than other finite differencing scheme.

유출유동을 가진 정사각유로 내 열전달 향상을 위한 경사진 요철 최적설계 (Optimization of Angled Ribs for Heat Transfer Enhancement in a Square Channel with Bleed Flow)

  • 이현;김경민;이동현;조형희
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.300-306
    • /
    • 2008
  • In the present study, the second order response surface method (RSM) is carried out to get optimum thermal design for enhancing heat transfer in a square channel with bleed flow. The RSM is used as an optimization technique. To calculate the heat transfer, RNG k-epsilon model and enhanced wall function are used. To design optimum rib turbulators, two design variables such as attack angle of rib $({\alpha})$ and rib pitch-to-rib height ratio (p/e) are optimized. In these analyses, the channel inlet Reynolds number was fixed at 10,000 in both non-bleeding and bleeding cases. The response surfaces of two design variables are constructed in cases with and without bleed flow. As a result, the optimum (or highest) heat transfer values are almost the same in ranges of two cases with and without bleed flow. However, the friction losses in the case with bleed flow are lower than those without bleed flow.