• Title/Summary/Keyword: $Z_2$

Search Result 7,100, Processing Time 0.036 seconds

Dynamic Voltage Restorer (DVR) for 6.6[kV]/60[Hz] Power Distribution System Using Two Quasi Z-Source AC-AC Converters (두 개의 Quasi Z-소스 AC-AC 컨버터에 의한 6.6[kV]/60[Hz] 배전계통의 동적 전압 보상기(DVR))

  • Oum, Jun-Hyun;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.199-208
    • /
    • 2012
  • This paper proposes a quasi Z-source DVR(Dynamic Voltage Restorer) system with a series connection of the output terminals, to compensate the voltage variations in the 6.6[kV]/60[Hz] power distribution system. The conventional DVR using one quasi Z-source AC-AC converter has the advantage which it can compensate the voltage variations without the need for the additional energy storage device such as a battery, but it is impossible to compensate for the 50[%] under voltage sags. To solve this problem, a DVR system using two quasi Z-source AC-AC converters with the series connection of the output terminals is proposed. By controlling the duty ratio D in the buck-boost mode, the proposed system can control the compensation voltage. For case verification of the proposed system, PSIM simulation is achieved. As a result, in case that the voltage sags-swells occur 10[%], 20[%], 60[%] in power distribution system, and, in case that the 50[%] under voltage sags-swells continuously occur, all case could compensate by the proposed system. Especially, the compensated voltage THD was examined under the condition of the 10[%]~50[%] voltage sags and the 20[${\Omega}$]~100[${\Omega}$] load changes. The compensated voltage THD was worse for the higher load resistances and more severe voltage sags. Finally, In case of the voltage swells compensation, the compensation factor has approached nearly 1 regardless of the load resistance changes, while the compensation factor of voltage sags was related to the load variations.

Subclinical Vitamin D Insufficiency in Korean School-aged Children

  • Han, Sang Woo;Kang, Ha Ra;Kim, Han Gyum;Kim, Joo Hyun;Uhm, Ji Hyun;Seo, Ji Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.16 no.4
    • /
    • pp.254-260
    • /
    • 2013
  • Purpose: Recently, vitamin D insufficiency has increased and has been correlated to growth and puberty in children. This study was conducted to find the prevalence of subclinical vitamin D insufficiency and its influence on school-aged children in Korea. Methods: The subjects of this study were 397 children aged 7 to 15 years who had been tested for 25-OH vitamin D3 among the outpatients of the Department of Pediatrics in Eulji General Hospital from March 2007 to February 2011. Data for age, sex, comorbidities, serum 25-OH vitamin D3, height, weight, body mass index (BMI), and sunlight exposure time were collected before and after 3 months of vitamin D administration, retrospectively. Results: Vitamin D insufficiency was present in 343 (86%) of the subjects. In the vitamin D insufficient group, chronological age was $8.96{\pm}1.72$ years, mean height (z-score [z]) was $0.51{\pm}1.26$, mean BMI (z) was $0.81{\pm}2.20$, and bone age was $10.26{\pm}1.75$ years. In the vitamin D sufficient group, chronological age was $9.61{\pm}1.77$ years, mean height (z) was -$0.66{\pm}0.98$, mean BMI (z) was -$0.01{\pm}1.16$, and bone age was $9.44{\pm}2.12$ years. A paired t-test showed that three months after vitamin D administration, the mean 25-OH vitamin D3 level in the insufficient group increased to $24.38{\pm}10.03$ ng/mL and mean BMI (z) decreased to $0.67{\pm}1.06$. Conclusion: In Korean school-aged children, vitamin D insufficiency were relatively higher and may be closely related with higher BMI. Insufficient rise of the level of vitamin D after supplementation suggest the new supplementation guidelines, especially for Korean children.

Validation of the semi-analytical algorithm for estimating vertical underwater visibility using MODIS data in the waters around Korea

  • Kim, Sun-Hwa;Yang, Chan-Su;Ouchi, Kazuo
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.6
    • /
    • pp.601-610
    • /
    • 2013
  • As a standard water clarity variable, the vertical underwater visibility, called Secchi depth, is estimated with ocean color satellite data. In the present study, Moderate Resolvtion Imaging Spectradiometer (MODIS) data are used to measure the Secchi depth which is a useful indicator of ocean transparency for estimating the water quality and productivity. To estimate the Secchi depth $Z_v$, the empirical regression model is developed based on the satellite optical data and in-situ data. In the previous study, a semi-analytical algorithm for estimating $Z_v$ was developed and validated for Case 1 and 2 waters in both coastal and oceanic waters using extensive sets of satellite and in-situ data. The algorithm uses the vertical diffuse attenuation coefficient, $K_d$($m^{-1}$) and the beam attenuation coefficient, c($m^{-1}$) obtained from satellite ocean color data to estimate $Z_v$. In this study, the semi-analytical algorithm is validated using temporal MODIS data and in-situ data over the Yellow, Southern and East Seas including Case 1 and 2 waters. Using total 156 matching data, MODIS $Z_v$ data showed about 3.6m RMSE value and 1.7m bias value. The $Z_v$ values of the East Sea and Southern Sea showed higher RMSE than the Yellow Sea. Although the semi-analytical algorithm used the fixed coupling constant (= 6.0) transformed from Inherent Optical Properties (IOP) and Apparent Optical Properties (AOP) to Secchi depth, various coupling constants are needed for different sea types and water depth for the optimum estimation of $Z_v$.

Evaluation of the Impact Force on the Vertically Placed Force Platform (지면반력 측정기 수직 설치 시 충격력 검증)

  • Choi, Chi-Sun;Shin, In-Sik;Seo, Jung-Suk
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.2
    • /
    • pp.57-68
    • /
    • 2004
  • This study was to evaluate the consistency of the vertical force($F_z$) of the force platform and the impact force. Two experiments were performed. First, the force platform was vertically placed to hang to the wall. While the rotating iron body hit the force platform, $F_z$ was measured. Then $F_z$ was compared with the impact force of the rotating iron body that was precalculated by using the inertia moments and the rotating force. Second, six Taekwondo masters punched the force platform to show what a certain pattern the impart force has. They were asked to punch the target depending on target distances. The target distances were differed from the relative arm segment of subjects as 90%, 80%, 70%, 60%, and 50% (100% target distance equals the aim length of each subject). Pearson's correlations were used between $F_z$ and the impact force. Also the linear regression was also performed to show the linearity. At the first experiment, $F_z$ and the impact force had much correlations and showed linear characteristics. Therefore, $F_z$ could be regarded as the impact force. At the second experiment, the strongest impact force was measured at the target distance of 80% and the time taken to the maximum impact force was within 0.02 seconds. The result of this study recommends that it can help the comparative study between the impact forces and other hitting sports.

Comparison of Two Intramuscular Injection Techniques on the Severity of Discomfort and leasions at the Injection Site (근육주사법에 따른 주사부위의 불편감과 조직손상의 차이에 관한 연구)

  • 김경선
    • Journal of Korean Academy of Nursing
    • /
    • v.18 no.3
    • /
    • pp.257-268
    • /
    • 1988
  • The purpose of this study was to compare the effect of the Z-track intramuscular injection technique with the effect of the stand and intramuscular injection technique on the severity of discomfort and leasions at the injection site. The subjects of the study were 20 patients with only early tuber culosis excluding another abnormalities (a akin rash, allergy to topical use of alcohol, jaundice, edema, neurosensory abnormality, coagulation defects, obesity and thin). Data collection was done from Feb. 1 to March 15, 1988 by means of Korean Pain Measurement Tool, Visual Analogue Scale, and Objective measures of injection site lesions. The results of this study were as follows ; 1) Hypothesis 1 ; “The severity of subject discomfort is less following administration of the Z-track intramuscular injection technique than following administra tion injection technique.” was not sopported 2) Hypothesis 2 ; “The degress of severity subject discomfort is less following administration of the Z-track intramuscular injection technique than following administra tion of the standard intramuscular injection technique.” was not supported. 3) Hypothesis 3 ; “The severity of injection site lesions is less following administra tion of the Z-track intramuscular injection technique than following administration of the standard intramuscular injection techniques.” was not supported. 4) The terms that were selected included factor II (mild-moderate pain) of Ratio Scale Measuring Pain using Korean Pain Terms. In conclusion ; it was found that there was not a difference from the severity of subject discomfort between two groups, but the degress of severity of subject discomfort about following administration of the Z-t-rack intramuscular injection was tended to be declined. Therefore further studies suggest that the Z-track intramuscular injection technique can decrease the severity of discomfort in persons receiving frequently intramuscular injections. First of all, it is necessery to be developed an effective tool of discomfort measurement for the intramuscular injection in Korean.

  • PDF

Degrees of Freedom for MIMO Z-Interference Channels with Reconfigurable Antennas in the Absence of CSIT (송신단 채널 정보가 없는 재구성 안테나를 사용한 다중입출력 Z-간섭 채널에서의 자유도)

  • Yang, Heecheol;Lee, Jungwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.42 no.2
    • /
    • pp.291-298
    • /
    • 2017
  • In this paper, we derive the achievable degrees of freedom (DoF) for multiple-input multiple-output (MIMO) Z-interference channels (Z-IC) with reconfigurable antennas at the receivers, assuming that channel state information is not available at the transmitters. We propose a new linear scheme to align interfering signals and to decode desired signals through the designed preset mode switching pattern of reconfigurable antennas at the receivers. The key idea of our scheme is to use interfering signals as a side information at the interfered receiver by being silent at the corresponding transmitter during some time slots. Consequently, it is shown that the reconfigurable antennas at the receivers can bring a DoF gain if the number of preset modes is greater than the number of RF chains at the receivers.

A Novel z-axis Accelerometer Fabricated on a Single Silicon Substrate Using the Extended SBM Process (Extended SBM 공정을 이용하여 단일 실리콘 기판상에 제작된 새로운 z 축 가속도계)

  • Ko, Hyoung-Ho;Kim, Jong-Pal;Park, Sang-Jun;Kwak, Dong-Hun;Song, Tae-Yong;Cho, Dong-Il;Huh, Kun-Soo;Park, Jahng-Hyon
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.101-109
    • /
    • 2004
  • This paper presents a novel z-axis accelerometer with perfectly aligned vertical combs fabricated using the extended sacrificial bulk micromachining (extended SBM) process. The z-axis accelerometer is fabricated using only one (111) SOI wafer and two photo masks without wafer bonding or CMP processes as used by other research efforts that involve vertical combs. In our process, there is no misalignment in lateral gap between the upper and lower comb electrodes, because all critical dimensions including lateral gaps are defined using only one mask. The fabricated accelerometer has the structure thickness of $30{\mu}m$, the vertical offset of $12{\mu}m$, and lateral gap between electrodes of $4{\mu}m$. Torsional springs and asymmetric proof mass produce a vertical displacement when an external z-axis acceleration is applied, and capacitance change due to the vertical displacement of the comb is detected by charge-to-voltage converter. The signal-to-noise ratio of the modulated and demodulated output signal is 80 dB and 76.5 dB, respectively. The noise equivalent input acceleration resolution of the modulated and demodulated output signal is calculated to be $500{\mu}g$ and $748{\mu}g$. The scale factor and linearity of the accelerometer are measured to be 1.1 mV/g and 1.18% FSO, respectively.

Characterization of Alcohol Dehydrogenase Encoded by Zymomonas mobilis Gene Cloned in Escherichia coli (Escherichia coli 형질전환체가 생산하는 Zymomonas mobilis 알콜 탈수소 효소의 분석)

  • 신병식;윤기홍;박무영
    • Microbiology and Biotechnology Letters
    • /
    • v.18 no.3
    • /
    • pp.268-272
    • /
    • 1990
  • The structural gene (zadhII) encoding an alcohol dehydrogenase II from Zyrnornonas mobilis was cloned into Escherichia coli in our laboratory (Yoon et al., 1989. Kor. J. Microbiol. Biotechnol.). From E. coli (pADS93) carrying the zadhII gene, the Z mobilis alcochol dehydrogenase II (ZADH-II) was purified by sonication, $(NH_4)_2SO_4$, fractionation, and chromatography. The ZADH-I1 enzyme produced by Z. mobilis cell was also purified to compare to the enzyme produced by E. coli (pADS93). The purified enzyme from cell extract of E. coli (pADS93) was identified to be a tetramer being composed of four identical subunits having molecular weight of 40, 000 dalton like that of Z. mobilis. The pH optimum for the reaction oxidizing ethanol to acetaldehyde was 10.0 while the optimum for the reverse reaction was 7.5-8.5. The apparent $K_m$ values for ethanol and NAD + were $1.2 \times 10^{-1}M$and $5.1\times 10^{-5}M$, respectively. In addition, it was found that the $K_m$ value for acetaldehyde was very lower than that for ethanol.

  • PDF

Development of Vending Machine for Electricity Based on Z-Wave Mesh Network (Z-Wave 메쉬 네트워크 기반의 전기 자판기 개발)

  • Kang, Ki-beom;Ahn, Hyun-kwon;Kim, Han-soo;Lee, Seung-hyun;Jwa, Jeong-woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.10
    • /
    • pp.1256-1262
    • /
    • 2016
  • As the population of camping is increased in campsites and auto camp sites, the electrical equipment can safely supply electricity to users in a variety of electricity bill policy is required in the campsite. In this paper, we develop the vending machine for electricity that can control the outdoor electrical outlet from the management server using the Z-Wave WPAN and android mobile application. The developed vending machine for electricity consists of the management server, the controller, the outdoor outlet box, and the mobile application. The management server provides reservation and electricity bill payment to users. The management server controls the electrical outlet box through the controller to safely supply electricity to users. The controller that is a relay device between the management server and the switch controls switches based on Z-Wave mesh network. Outdoor electrical outlet box has 2 meter switches. We receive the relevant authorization to provide commercial electricity services using the outdoor electrical outlet box in the campsite.

Initial Pole Position Estimation Algorithm of a Z-Axis PMLSM (Z축 선형 영구자석 동기전동기의 초기 자극위치 추정 알고리즘)

  • Lee, Jin-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • This paper deals with the estimation method on the initial pole position of a z-axis permanent magnet linear synchronous motor(PMLSM) without magnetic pole sensors such as Hall sensors. The proposed method takes account of the gravitational force at z-axis and also the load conditions. The algorithm consists of two steps. The first step is to approximately estimate the initial q-axis by monitoring the movements due to the test current at predefined different test q-axes. The second step is to estimate the real q-axis as accurately as possible by using the outputs corresponding to torques due to the test current at three different test q-axes in order to avoid the effect of load mass variations. Experimental results on the z-axis PMLSM show good estimation characteristics of the proposed method irrespective of load mass conditions.