• Title/Summary/Keyword: $Z_2$

Search Result 7,101, Processing Time 0.036 seconds

Acupotomy Treatment for Lumbar Disc Herniation

  • Xilin, Chen;Xinyi, Fu;Zhichao, Luo;Wenshan, Xin;Quangui, Wang;Mira, Lee;Changqing, Guo
    • Journal of Acupuncture Research
    • /
    • v.37 no.3
    • /
    • pp.177-180
    • /
    • 2020
  • Background: The aim of this study was to examine whether the effects of acupotomy therapy were beneficial for the treatment of protrusion of lumbar intervertebral disc. Methods: The number of patients (n = 80) were equally assigned into treatment group and control group. Treatment group was given acupotomy therapy twice a week, and control group was given acupuncture 3 times a week, for 4 weeks. The beneficial effect and changes in score of the Japan Orthopedic Association (JOA) for low back pain were observed. Results: Among 40 cases in the treatment group, there were 25 (62.5%) with an excellent effect, 13 (32.5%) with good effect, 1 (2.5%) with a medium effect and 1 (2.5%) with poor effect, with the total experiencing an excellent/good effect of 95.0%. Among 40 cases in the control group, there were 11 (27.5%) with an excellent effect, 17 (42.5%) with good effect, 10 (25.0%) with a medium effect, and 2 (5.0%) with poor effect, with an excellent/good rate of 70.0%. The result of the rank sum test showed Z = -4.923, p < 0.05 in the comparison, indicating a significantly better outcome following acupotomy compared with acupuncture. JOA scores increased in both groups after treatment (p < 0.05), which was more significant in the acupotomy treatment group (p < 0.05). Conclusion: Acupotomy therapy has a beneficial effect on protrusion of lumbar intervertebral disc.

Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods

  • Lee, Hwa Shim;Lee, Jong Man;Park, Sang Ryoul;Lee, Je Hoon;Kim, Yong Goo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1698-1702
    • /
    • 2013
  • Glucose is a common medical analyte measuring in human serum or blood samples. The development of a primary method is necessary for the establishment of traceability in measurements. We have developed an isotope dilution liquid chromatography tandem mass spectrometry as a primary method for the measurement of glucose in human serum. Glucose and glucose-$^{13}C_6$ in sample were ionized in ESI negative mode and monitored at mass transfers of m/z 179/89 and 185/92 in MRM, respectively. Glucose was separated on $NH_2P$-50 2D column, and the mobile phase was 20 mM $NH_4OAc$ in 30% acetonitrile/70% water. Verification of this method was performed by the comparison with NIST SRMs. Our results agreed well with the SRM values. We have developed two levels of glucose serum certified reference material using this method and distributed them to the clinical laboratories in Korea as samples for proficiency testings. The expended uncertainty was about 1.2% on 95% confidence level. In proficiency testings, the results obtained from the clinical laboratories showed about 3.6% and 3.9% RSD to the certified values. Primary method can provide the traceability to the field laboratories through proficiency testings or certified reference materials.

a study on the elastic wave delay line (탄성파 지정선에 관한 연구)

  • 김종상
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.6
    • /
    • pp.1-15
    • /
    • 1974
  • In this paper, the SH mode of elastic surface waves which are used for delay lines of elastic surface wave is the cretically analysed. It is shown that the SH mode has very large electromechanical coupling factor and propagates on the surface with very small decaying coefficient into the medium. In the case of P2T-4, the depth cf piezoelectric medium that contains 80% of energy is 190 wavelengths. An elastic surface wave delay line is discussed from the view point of 2-port network. Center frequency is shifted by the ratio of transducer electrode width to gap between transducer ellcerodes when electromechanical coupling factor is large. Tempera _ore coefficients for bulk waves of LiNbO3 and LiTaO3 are also calculated and the minimum temperature coefficient value of delay time is 5.4X 10-6/$^{\circ}C$ ia the case of transverse wave propagating along Z axis on LiTaO3. Experimental data are in good agreement with theoretical values of the temperature coefficients of delay time for elastic surface waves propagating along X axis of 130$^{\circ}$ and 64$^{\circ}$ rotated Y cut planes of the LiNbO3.

  • PDF

Limitation of effective length method and codified second-order analysis and design

  • Chan, S.L.;Liu, Y.P.;Zhou, Z.H.
    • Steel and Composite Structures
    • /
    • v.5 no.2_3
    • /
    • pp.181-192
    • /
    • 2005
  • The effective length method for flexural (column) buckling has been used for many decades but its use is somewhat limited in various contemporary design codes to moderately slender structures with elastic critical load factor (${\lambda}_{cr}$) less than 3 to 5. In pace with the use of higher grade steel in recent years, the influence of buckling in axial buckling resistance of a column becomes more important and the over-simplified assumption of effective length factor can lead to an unsafe, an uneconomical or a both unsafe and uneconomical solution when some members are over-designed while key elements are under-designed. Effective length should not normally be taken as the distance between nodes multiplied by an arbitrary factor like 0.85, 1.0, 2.0 etc. Further, the classification of non-sway and sway-sensitive frames makes the conventional design procedure tedious to use and, more importantly, limited to simple regular frames. This paper describes the practical use of second-order analysis with section capacity check allowing for $P-{\delta}$ and $P-{\Delta}$ effects together with member and system imperfections. Most commercial software considers only the $P-{\Delta}$ effect, but not member and frame imperfections nor $P-{\delta}$ effect, and engineers must be very careful in their uses. A verification problem is also given for validation of software for this type of powerful second-order analysis and design. It is a trend for popular and advanced national design codes in using the second-order analysis as a norm for analysis and design of steel structures while linear analysis may only be used in very simple structures.

Role of span length in the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques

  • Zhou, Ying;Li, Yong;Ma, Xiao;Huang, Yiqing;Wang, Jiawei
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.2
    • /
    • pp.124-129
    • /
    • 2017
  • PURPOSE. This study evaluated the effect of span length on the adaptation of implant-supported cobalt chromium frameworks fabricated by three techniques. MATERIALS AND METHODS. Models with two solid abutment analogs at different inter-abutment distances were digitized using a laboratory scanner. Frameworks of two-, three-, and four-unit fixed prostheses were designed by a computer. Six dots with a diameter of 0.2 mm were preset on the surface of each framework. A total of 54 implant-supported cobalt chromium frameworks were fabricated by milling, selective laser melting (SLM), and cast techniques. The frameworks were scanned and exported as Stereolithography files. Distances between two dots in X, Y, and Z coordinates were measured in both the designed and fabricated frameworks. Marginal gaps between the framework and the abutments were also evaluated by impression replica method. RESULTS. In terms of distance measurement, significant differences were found between three- and four-unit frameworks, as well as between two- and four-unit frameworks prepared by milling technique (P<.05). Significant differences were also noted between two- and three-unit frameworks, as well as between two- and four-unit frameworks prepared by cast technique (P<.05). The milling technique presented smaller differences than the SLM technique, and the SLM technique showed smaller differences than the cast technique at any unit prostheses (P<.05). Evaluation with the impression replica method indicated significant differences among the span lengths for any fabrication method (P<.05), as well as among the fabrication methods at any unit prostheses (P<.05). CONCLUSION. The adaptation of implant-supported cobalt chromium frameworks was affected by the span length and fabrication method.

Difference in Core Stability and Muscle Balance of the Pilates Teaser Motion According to Kinds of the Ground and Skills (지면의 종류와 숙련도에 따른 필라테스 티져(Teaser)동작의 코어안정화와 근육 균형의 차이)

  • Shin, Yun-Kyung;Yi, Kyung-Ock
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.65-76
    • /
    • 2015
  • Objective : The purpose of this study was to analyse the differences in core stability and muscle balance of the pilates Teaser motion according to the surfaces and skills. Methods : There were 10 subjects in this study with 5 being skilled and 5 that were not skilled. The independent variables were surfaces (high elastic & aluminum) and skills (skilled & unskilled). Dependent variables were core stability and muscle balance. Core stability was measured by Force Platform (9872, Switzerland), 3D Imagery (IBS-2000, EXYMA) was used to understand the muscle balance. In order to do the Teaser movement subjects had to lay flat on their back and then lean forward as much as possible and hold the position for 10 seconds. Afterwards, they would lay back down again. A camera (MHS-PM5K, SONY) was used to make 4 phases (take off, recoil forward, holding, recoil backward) during the teaser exercise to analyze movement. In this study quantitative and qualitative analysis was used. For the statistical analysis, 2X2 ANOVA was used to analyze the differences in movement time, X,Y,Z maximum force, center of pressure and angles according to different phases. 2X3 ANOVA was used to analyze the differences in muscle balance via SPSS 18.0. Results : Soft. Elastic mat had a longer holding time, lower Fx/ Fy/ Fz, shorter Fx trajectory, larger angle and shorter gaps in muscle balance than a hard surface in skilled subjects. This was because the mat can help to recruit and then sustain core fine muscles during holding time in the Teaser movement.

Effects of extrusion of rice bran on performance and phosphorous bioavailability in broiler chickens

  • Zare-Sheibani, Ali Akbar;Arab, Masoud;Zamiri, Mohammad Javad;Rezvani, Mohammad Reza;Dadpasand, Mohammad;Ahmadi, Farhad
    • Journal of Animal Science and Technology
    • /
    • v.57 no.7
    • /
    • pp.26.1-26.5
    • /
    • 2015
  • Background: Rice bran is a by-product of the rice-milling process, which remains largely underutilized; however, efficient processing treatments may improve its feeding value for chickens. This is of great economic and environmental importance, as this can lower the production costs, and offer an opportunity for valorization of a low-quality agricultural by-product, to a high-value feed source. Methods: This experiment was conducted to study the effect of extruded rice bran on performance and phosphorous (P) bioavailability in broiler chickens. In a completely randomized design, 200 seven-day-old broilers (Cobb 500) were allotted to five treatments with five replicates per treatment and 8 chicks per replicate, and fed with their respective diet during the starter (8 to 21 days) and grower (22 to 42 days) periods. Diets were a basal corn-soybean based diet (T1), or diets containing 20 % rice bran (T2), 30 % rice bran (T3), 20 % extruded rice bran (T4), or 30 % extruded rice bran (T5). Results: Birds feeding on T4 and T5 diets had a higher body weight gain and lower feed-to-gain ratio compared to those feeding on T2 and T3 diets (p < 0.05). Birds receiving diets containing extruded rice bran had higher total P availability and tibia ash content, as compared with those receiving diets containing un-extruded rice bran (p < 0.05). Relative weight of the pancreas was higher in birds receiving T2 and T3 diets. Conclusions: The results confirmed the beneficial effect of extrusion treatment of rice bran on performance and P availability in broilers. Up to 30 % extruded rice bran may be included in the broiler diet without apparent adverse effects on the performance.

Comparative Evaluation of Resolution according to Frequency Change for SPECT (단일광자방출전산화단층촬영(SPECT)을 위한 주파수 변동에 따른 분해능 비교평가)

  • Kim, Sung-Chul;Park, Soo-Yeun;Cho, Young-Kwon;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.322-331
    • /
    • 2009
  • In clinical SPECT, FWHM provides quality information of the images obtained under different observing conditions. Therefore, the purpose of this study was to determine the optimum cut off level with comparison of FWHM according to cut off levels in each filter - Band limited, Sheep-Logan, Hanning, Hamming, Low pass cosine, Parazen and Butterworth filter in a SPECT camera. I recorded images along the X, Y, Z-axis with 99mTcO4 point source and measured FWHM with profile curves. In conclusion, all filters showed the longest figures of FWHM with cut off level 0.4, which has the worst image resolution. The images with cut off level 0.7 showed best image resolution. The shortest average of FWHM in MS2 was $11.07\pm0.07mm$ using the Butterworth filter, in MS3 it was $8.44\pm0.19mm$ through using the Hanning filter.

Synthesis of Needle-Like Aragonite Crystals in the Presence of Magnesium Chloride and Their Application in Papermaking

  • Hu, Zeshan;Shao, Minghao;Li, Huayang;Cai, Qiang;Zhong, Chenghua;Xianming, Zhang;Deng, Yulin
    • Advanced Composite Materials
    • /
    • v.18 no.4
    • /
    • pp.315-326
    • /
    • 2009
  • PCC (precipitated calcium carbonate) and ground calcium carbonate have been widely used in alkaline papermaking. Unfortunately, although increasing filler level in papers can improve the paper properties such as brightness, opacity, stiffness gloss, smoothness, porosity, and printability, as well as decrease cost, some strength of the paper is negatively affected. In this research, needle-like aragonite was synthesized using $Ca(OH)_2$ and $CO_2$ as reactants in the presence of $MgCl_2$ and characterized with scanning electronic microscopy (SEM) and X-ray diffraction (XRD). The physical and optical properties of the paper handsheets containing these needle-like aragonite fillers were evaluated. Results indicated that tensile strength, Z-direction tensile strength and folding endurance of the paper were improved by the needle-like aragonite crystals compared to the paper using commercial PCC (precipitated calcium carbonate) as filler. The stiffness of the paper handsheet on the machine direction was increased, but no evident difference in the cross direction was found. The improvement of paper strength mainly resulted from the twining effect between the aragonite whiskers and paper fibers. The optical properties of the paper were slightly decreased with the use of the needle-like aragonites compared to commercial PCC. These results suggest that paper cost can be decreased by increasing the content of needle-like aragonite filler while paper strength will not be decreased compared to PCC filler.

Analysis of a.c. Characteristics in Cr-doped ZnO Using Dielectric Functions (Cr을 첨가한 ZnO의 유전함수를 이용한 a.c. 특성 분석)

  • Hong, Youn-Woo;Shin, Hyo-Soon;Yeo, Dong-Hun;Kim, Jong-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.16-16
    • /
    • 2009
  • ZnO($Zn_{1+x}O$)는 n-type 반도성 세라믹스로 우수한 전기적, 광학적, 화학적 특성을 갖고 있어 바리스터, 투명 전도막, 화학 및 바이오 센서, UV light emitter 등 다양한 용도로 사용되고 있다. 또한 ZnO에 각종 천이 금속 산화물을 일정량 첨가함에 따라 발생하는 결함준위와 입계 특성의 변화에 대한 연구가 활발히 진행되고 있다. 다양한 천이 금속 산화물의 첨가에 따른 전기적 광학적 특성의 변화에 대한 결과들이 많이 보고되고 있지만 서로 상충되거나 해석상 다소 어려운 것으로 알려져 있다. 따라서 본 연구에서는 ZnO에 $Cr_2O_3$를 2.0 at% 첨가하여 Cr 첨가에 따른 ZnO의 결함준위와 입계 특성 변화에 대하여 각종 유전함수($Z^*$, $Y^*$, $M^*$, $\varepsilon^*$, and $tan{\delta}$)를 이용하여 고찰하였다 ZnO에 Cr을 첨가할 경우 결함 중 장범위 쿨롱 인력에 의한 결함(0.13~0.18 eV)이 ~100K 영역에서 나타났으며, ZnO 내 결함 중 대표적인 $Zn_j$$V_o$는 서로 겹쳐서 나타났다. 이들 중첩된 결함에 대하여 각종 유전함수를 이용할 경우 서로 분리해 낼 수 있는 강점이 있음을 논하였다. 또한 각 결함준위가 강는 정전용랑(C)과 저항(R)을 impedance-modulus spectroscopy를 이용하여 구한 결과, 소결온도가 높아질수록 정전용량은 증가하였으며, 측정온도가 놓아질수록 높아지는 경향을 나타내었다. 입계의 정전용량은 소결온도가 높아질수록 높아 지지만 측정온도가 높아질수록 낮아지는 경향을 나타내었다. 각 저항값은 소결온도 및 측정온도가 높아질수록 지수적으로 감소하였다. 또한 분포함수를 이용하여 입계 안정성에 대하여 고찰하였다.

  • PDF