• Title/Summary/Keyword: $Vs^{30}$

Search Result 1,724, Processing Time 0.035 seconds

Development of a Biosensor Using Electrochemically-Active Bacteria [EAB] for Measurements of BOD [Biochemical Oxygen Demand] (전기화학적 활성 미생물을 이용한 BOD 측정용 바이오센서의 개발)

  • Yoon, Seok-Min;Choi, Chang-Ho;Kwon, Kil-Koang;Jeong, Bong-Geun;Hong, Seok-Won;Choi, Yong-Su;Kim, Hyung-Joo
    • KSBB Journal
    • /
    • v.22 no.6
    • /
    • pp.438-442
    • /
    • 2007
  • A biosensor using electrochemically-active bacteria (EAB) enriched in three-electrode electrochemical cell, was developed for the determination of biochemical oxygen demand (BOD) in wastewater. In the electrochemical cell, the positively poised working electrode with applying a potential of 0.7 V was used as an electron acceptor for the EAB. The experimental results using artificial and raw wastewater showed that the current pattern generated by the biosensor and its Coulombic yield were proportional to the concentration of organic matter in wastewater. The correlation coefficients of BOD vs Coulombic yield and $BOD_5$ vs Coulombic yield were 0.99 and 0.98, respectively. These results indicate that the biosensor enriched with the EAB capable of transferring electrons directly toward the electrode can be utilized as a water-quality monitoring system due to a quick and accurate response.

Effects of noninvasive electrical stimulation on osseointegration of endosseous implants;A histomorphometric evaluation in the rabbit tibia (비침습적인 전기자극이 임프란트의 골융합에 미치는 영향;토끼경골에서의 조직계측학적 평가)

  • Sohn, Sung-Bae;Park, Jin-Woo;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.635-648
    • /
    • 2005
  • The procedure that enhances osteogenesis and shortens the healing period is required for successful implant therapy. It has been introduced that osteogenesis is enhanced by the generation of electric field. Many researchers have demonstrated that application of electric and electromagnetic field promote bone formation. It also has been shown that electrical stimulation enhances peri-implant bone formation. Recently, several investigators have reported that noninvasive electrical stimulation using negatively charged electret such as polytetrafluoroethylene(PTFE) promotes osteogenesis. Therefore, we were interested in the effect of noninvasive electrical stimulation using negatively charged electret on the periimplant bone healing. After titanium implant were installed in the proximal tibial metaphysis of New Zealand white rabbit, negatively charged PTFE membrane fabricated by corana dischage was inserted into the inner hole of the experimental implant and noncharged membrane was applied into control implant. After 4 weeks of healing, histomorphometric analysis was performed to evaluate peri-implant bone response. The histomorphometric evaluations demonstrated experimental implant tended to have higher values in the total bone-to-implant contact ratio(experimental ; $49.9{\pm}13.52%$ vs control ; $37.5{\pm}19.44%$) , the marrow bone contact ratio(experimental ; $34.94{\pm}13.32%$ vs control ; $24.15{\pm}13.69%$), amount of newly formed bone in the endosteal region(experimental ; $1.00{\pm}0.30mm$ vs control ; $0.61{\pm}0.24mm$) and bone area in the medullary canal(experimental ; $13.55{\pm}4.98%$ vs control ; $9.03{\pm}3.05%$). The mean values of the amount of newly formed bone(endosteal region) and bone area(medullary canal) of the experimental implant demonstrated a statistically significant difference as compared to the control implant(p<0.05). In conclusion, noninvasive electrical stimulation using negatively charged electret effectively promoted peri-implant new bone formation in this study. This method is expected to be used as one of the useful electrical stimulation for enhancing bone healing response in the implant therapy

Low consumption of fruits and dairy foods is associated with metabolic syndrome in Korean adults from outpatient clinics in and near Seoul

  • Song, SuJin;Kim, Eun-Kyung;Hong, Soyoung;Shin, Sangah;Song, YoonJu;Baik, Hyun Wook;Joung, Hyojee;Paik, Hee Young
    • Nutrition Research and Practice
    • /
    • v.9 no.5
    • /
    • pp.554-562
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: The aim of this study was to examine differences in nutrient intake and food consumption by the presence of metabolic syndrome in Korean adults. SUBJECTS/METHODS: Study subjects in this cross-sectional study were recruited from four outpatient clinics in and near the Seoul metropolitan area of South Korea between 2006 and 2012. A total of 668 subjects (413 men and 255 women) aged ${\geq}30y$ were included in the final data analyses. For each subject, daily nutrient intake and food consumption were calculated using three days of dietary intake data obtained from a combination of 24-hour recalls and dietary records. To evaluate food consumption, mean number of servings consumed per day and percentages of recommended number of servings for six food groups were calculated. Metabolic syndrome was defined using the National Cholesterol Education Program Adult Treatment Panel III criteria. The general linear model was performed to examine differences in nutrient intake and food consumption by sex and the presence of metabolic syndrome after adjustment for potential confounding variables. RESULTS: Nutrient intake did not differ by the presence of metabolic syndrome in both men and women. Men with metabolic syndrome had lower consumption and percentage of the recommendation for fruits compared with those without metabolic syndrome (1.6 vs. 1.1 servings/day, P-value = 0.001; 63.5 vs. 49.5%, P-value = 0.013). Women with metabolic syndrome showed lower consumption and percentage of the recommendation for dairy foods than those without metabolic syndrome (0.8 vs. 0.5 servings/day, P-value = 0.001; 78.6 vs. 48.9%, P-value = 0.001). CONCLUSIONS: Low intakes of fruits and dairy foods might be associated with the risk of having metabolic syndrome among Korean adults. Dietary advice on increasing consumption of these foods is needed to prevent and attenuate the risk of metabolic syndrome.

Comparing Effectiveness Rituximab (Mabthera®) to Other Second-line Biologics for Rheumatoid Arthritis Treatment in Patients Refractory to or Intolerant of First-line Anti-tumor Necrosis Factor Agent: An Observational Study

  • Park, Yong-Wook;Kim, Ki-Jo;Yang, Hyung-In;Yoon, Bo Young;Kim, Sang Hyon;Kim, Seong-Ho;Kim, Jinseok;Oh, Ji Seon;Kim, Wan-Uk;Lee, Yeon-Ah;Choe, Jung-Yoon;Park, Min-Chan;Lee, Sang-Heon
    • Journal of Rheumatic Diseases
    • /
    • v.24 no.4
    • /
    • pp.227-235
    • /
    • 2017
  • Objective. Failure of first-line anti-tumor necrosis factor (TNF) agents in in rheumatoid arthritis patients leads to decisions among second-line biologic agents. To better inform these decisions, the therapeutic effectiveness of rituximab is compared with other second-line biologic agents in this observational study. Methods. Between November 2011 and December 2014, study subjects were observed for 12 month periods. Patients with an inadequate response to initial anti-TNF agent received either rituximab or alternative anti-TNF agents (adalimumab/etanercept/infliximab) based on the preference of patients and physicians. The efficacy end point of this study was the change in 28-joint count Disease Activity Score (DAS28) at six and 12 months from baseline. Safety data were also collected. Results. Ninety patients were enrolled in the study. DAS28 at six months did not change significantly whether the patients were treated with rituximab or alternative anti-TNF agents in intention-to-treat analysis (n=34, $-1.63{\pm}0.30$ vs. n=31, $-2.05{\pm}0.34$) and standard population set analysis (n=31, $-1.51{\pm}0.29$ vs. n=24, $-2.21{\pm}0.34$). Similarly, the change in DAS28 at 12 months did not reach statistical significance ($-1.82{\pm}0.35$ in the rituximab vs. $-2.34{\pm}0.44$ in the alternative anti-TNF agents, p=0.2390). Furthermore, the incidences of adverse events were similar between two groups (23.5% for rituximab group vs. 25.8% for alternative anti-TNF agents group, p=0.7851). Conclusion. Despite the limitations of our study, switching to rituximab or alternative anti-TNF agents after failure of the initial TNF antagonist showed no significant therapeutic difference in DAS28 reduction.

Laboratory analysis of acute acetaminophen overdose patients in Emergency Medical Centers: including analysis of one toxicological laboratory data (응급의료센터에서 아세트아미노펜 과다복용 환자의 검사실 분석 현황: 일개 중독분석실 농도 분석자료 포함)

  • Kim, In Chan;Won, Sinae;Lee, Arum;Jung, Haeun;Lee, Jeongsun;Oh, Bum Jin
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.1
    • /
    • pp.31-37
    • /
    • 2021
  • Purpose: Acetaminophen (APAP) is a widely available drug responsible for a large part of drug-induced hepatotoxicity in developed countries. Although acetaminophen overdose cases in Korea are being continuously reported, there are no reports related to the level of this drug in the patient's blood or of laboratory analysis at emergency departments (ED). This study sought to analyze the acetaminophen overdose cases at a toxicological laboratory and to survey APAP analysis services offered at select EDs. Methods: We analyzed the demographic and analytic data at a toxicological laboratory run by the National Emergency Medical Center (NMC) in 2019-2020. We surveyed the APAP laboratory service in the 38 regional emergency medical centers (EMCs) and 68 local EMCs near the toxicological laboratory. Results: We studied 175 acute poisoning cases (112 women) with positive blood APAP results (mean age 47.0±24.1 years). Suicide attempts comprised 40.0% of the cases and 30.3% APAP overdose events. In the univariate analysis, we observed that patients were significantly younger, with fewer underlying medical diseases. There were a higher number of APAP overdose events, more favorable initial mental status, more toxic quantity intake in the above treatment line group (p<0.05), In multivariate analysis, the toxic amount intake was significantly more frequent in the above treatment line group (p<0.01). Hospital APAP analysis services were available in six EMCs (3/38 regional and 3/68 local). The hospital blood APAP level reporting intervals were shorter than outside-hospital laboratory services (p<0.01, regional 7.0±3.0 vs. 40.6±27.5, local 5.3±3.1 vs. 57.9±45.1 hours). The NMC toxicological laboratory reporting interval was shorter than the other outside-hospital laboratories (p<0.01, regional 5.7±0.6 vs. 50.2±22.7 local 7.5±3.0 vs. 70.5±41.5 hours). Conclusion: Over the treatment line group, toxic amount intake was significantly more frequent. Only six of 106 EMCs have their own APAP analysis service in their hospitals.

Endoscopic Findings and Treatment of Gastric Neoplasms in Familial Adenomatous Polyposis

  • Sato, Chihiro;Takahashi, Kazuya;Sato, Hiroki;Naruse, Takumi;Nakajima, Nao;Takatsuna, Masafumi;Mizuno, Ken-ichi;Hashimoto, Satoru;Takeuchi, Manabu;Yokoyama, Junji;Kobayashi, Masaaki;Terai, Shuji
    • Journal of Gastric Cancer
    • /
    • v.22 no.4
    • /
    • pp.381-394
    • /
    • 2022
  • Purpose: Gastric neoplasia is a common manifestation of familial adenomatous polyposis (FAP). This study aimed to elucidate the clinical characteristics, endoscopic features including fundic gland polyposis (FGPsis), and treatment outcomes of gastric neoplasms (GNs) in patients with FAP. Materials and Methods: A total of 35 patients diagnosed with FAP, including nine patients from four pedigrees who underwent esophagogastroduodenoscopy (EGD), were investigated regarding patient characteristics, GN morphology, and treatment outcomes. Results: Twenty-one patients (60.0%) had 38 GNs; 33 (86.8%) and 5 (13.2%) were histologically diagnosed with adenocarcinoma and adenoma, respectively. There were no specific patient characteristics related to GNs.Nodule-type GNs were more prevalent in patients with FGP than without (52.2% vs. 0.0%, P=0.002) in the upper body of the stomach. Conversely, depressed-type GNs were fewer in patients with FGPsis than in those without (13.0% vs. 73.3%, P<0.001). Slightly elevated-type GNs were observed in both groups (34.8% vs. 20.0%, P=0.538). Even within pedigrees, the background gastric mucosa and types of GNs varied. In total, 24 GNs were treated with endoscopic submucosal dissection (ESD) and eight with endoscopic mucosal resection (EMR). EMR was selected for GNs with FGPsis because of the technical difficulty of ESD, resulting in a lower en bloc resection rate (62.5% vs. 100%, P=0.014). Conclusions: Our study indicates the necessity of routine EGD surveillance in patients diagnosed with FAP. Notably, the morphology and location of GNs differed between patients with and without FGPsis. Endoscopic treatment and outcomes require more attention in cases of FGPsis.

S-velocity and Radial Anisotropy Structures in the Western Pacific Using Partitioned Waveform Inversion (분할 파형 역산을 사용한 서태평양 지역 S파 속도 및 방사 이방성 구조 연구)

  • Ji-hoon Park;Sung-Joon Chang;Michael Witek
    • Economic and Environmental Geology
    • /
    • v.56 no.4
    • /
    • pp.365-384
    • /
    • 2023
  • We applied the partitioned waveform inversion to 2,026 event data recorded at 173 seismic stations from the Incorporated Research Institutions for Seismology Data Managing Center and the Ocean Hemisphere network Project to estimate S-wave velocity and radial anisotropy models beneath the Western Pacific. In the Philippine Sea plate, high-Vs anomalies reach deeper in the West Philippine basin than in the Parece-Vela basin. Low-Vs anomalies found at 80 km below the Parece-Vela basin extend deeper into the West Philippine Basin. This velocity contrast between the basins may be caused by differences in lithospheric age. Low-Vs anomalies are observed beneath the Caroline seamount chain and the Caroline plate. Overall positive radial anisotropy anomalies are observed in the Western Pacific, but negative radial anisotropy is found at > 220 km depth on the subducting plate along the Mariana trench and at ~50 km in the Parece-Vela basin. Positive radial anisotropy is found at > 200 km depth beneath the Caroline seamount chain, which may indicate the 'drag' between the plume and the moving Pacific plate. High-Vs anomalies are found at 40 ~ 180 km depth beneath the Ontong-Java plateau, which may indicate the presence of unusually thick lithosphere due to underplating of dehydrated plume material.

Analysis of Indicated Points and Main Factors Affecting the Quality of Clinical Research for the Development of Internal Audit Tools (자체점검 도구 개발을 위한 지적사항 및 임상연구의 품질에 작용하는 요인 분석)

  • Hye Yun Jang;Jung-Hee Jang;Yoon Jin Lee
    • The Journal of KAIRB
    • /
    • v.5 no.1
    • /
    • pp.14-20
    • /
    • 2023
  • Purpose: To obtain fundamental data on selection tools for an internal audit and develop a new guideline. We scored the indicated points from the internal audit, identified the research progress and problems that occurred, and confirmed the validity of the risk factors involved. Methods: Of the 63 internal audits conducted by Keimyung University Dongsan Hospital from 2014 to 2021, we analyzed 55 clinical trials with an inspection checklist. We excluded 8 that failed to transfer data and refused to comply with the internal audit. The statistical summary of the collected data was verified and interpreted by using frequency analysis and a chi-square test. Result: Of total 55 cases included in the internal audit, sponsor-initiated trial (SIT) was 63.6% (vs. investigator-initiated trial [IIT]), clinical trial for investigational drug was 71.0% (vs. nonclinical or clinical trial for investigational device), domestic multicenter trial was 60.0% (vs. single center or multinational multicenter trial), and trial requisition for MFDS approval was 69.1% (vs. exception for MFDS approval). The 10 areas of the clinical trial inspection checklist (reports, protection of subjects, compliance with protocols, records, management of investigational drug and/or device, delegation of duties, qualification of investigators, management of specimen, contract-agreement and approval of protocols, and preservation of recorded documents) were weighted between 2 to 5 points. The average of the total points was 16.09±13.2 and 20 clinical trials were above the average. As a result of comparing the average of the total points weighted by year, the highest score was in 2020. The 4 factors that play significant roles in determining the internal quality were (1) principal subjects that initiated the clinical trials (p=0.049), (2) type (p=0.003), (3) phase of clinical trials (p=0.024), and (4) number of registered subjects reported at the time of continuing deliberation (p=0.019). Of the 10 areas of the clinical trial inspection checklist, 'record' was the most inappropriate and insufficient. We found more indicated points; the quality of performance declined in IIT, nonclinical trials, and other clinical trials that were not in phase I1-IV4, and the study of more than 30 registered subjects at the time of continuing review. Conclusion: If an institution has an internal audit selection tool that reflects the aforementioned risk factors, it will be possible to effectively manage high-risk studies; thereby, contributing to an efficient internal audit and improving the quality of clinical trials.

  • PDF

Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT

  • Masafumi Takafuji;Kakuya Kitagawa;Masaki Ishida;Yoshitaka Goto;Satoshi Nakamura;Naoki Nagasawa;Hajime Sakuma
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.58-67
    • /
    • 2020
  • Objective: Third-generation dual-source computed tomography (3rd-DSCT) allows dynamic myocardial CT perfusion imaging (dynamic CTP) with a 10.5-cm z-axis coverage. Although the increased radiation exposure associated with the 50% wider scan range compared to second-generation DSCT (2nd-DSCT) may be suppressed by using a tube voltage of 70 kV, it remains unclear whether image quality and the ability to quantify myocardial blood flow (MBF) can be maintained under these conditions. This study aimed to compare the image quality, estimated MBF, and radiation dose of dynamic CTP between 2ndDSCT and 3rd-DSCT and to evaluate whether a 10.5-cm coverage is suitable for dynamic CTP. Materials and Methods: We retrospectively analyzed 107 patients who underwent dynamic CTP using 2nd-DSCT at 80 kV (n = 54) or 3rd-DSCT at 70 kV (n = 53). Image quality, estimated MBF, radiation dose, and coverage of left ventricular (LV) myocardium were compared. Results: No significant differences were observed between 3rd-DSCT and 2nd-DSCT in contrast-to-noise ratio (37.4 ± 11.4 vs. 35.5 ± 11.2, p = 0.396). Effective radiation dose was lower with 3rd-DSCT (3.97 ± 0.92 mSv with a conversion factor of 0.017 mSv/mGy∙cm) compared to 2nd-DSCT (5.49 ± 1.36 mSv, p < 0.001). Incomplete coverage was more frequent with 2nd-DSCT than with 3rd-DSCT (1.9% [1/53] vs. 56% [30/54], p < 0.001). In propensity score-matched cohorts, MBF was comparable between 3rd-DSCT and 2nd-DSCT in non-ischemic (146.2 ± 26.5 vs. 157.5 ± 34.9 mL/min/100 g, p = 0.137) as well as ischemic myocardium (92.7 ± 21.1 vs. 90.9 ± 29.7 mL/min/100 g, p = 0.876). Conclusion: The radiation increase inherent to the widened z-axis coverage in 3rd-DSCT can be balanced by using a tube voltage of 70 kV without compromising image quality or MBF quantification. In dynamic CTP, a z-axis coverage of 10.5 cm is sufficient to achieve complete coverage of the LV myocardium in most patients.

Outcomes of partially covered self-expandable metal stents with different uncovered lengths in endoscopic ultrasound-guided hepaticogastrostomy: a Japanese retrospective study

  • Takeshi Okamoto;Takashi Sasaki;Tsuyoshi Takeda;Tatsuki Hirai;Takahiro Ishitsuka;Manabu Yamada;Hiroki Nakagawa;Takafumi Mie;Takaaki Furukawa;Akiyoshi Kasuga;Masato Ozaka;Naoki Sasahira
    • Clinical Endoscopy
    • /
    • v.57 no.4
    • /
    • pp.515-526
    • /
    • 2024
  • Background/Aims: The optimal length of the uncovered portion of partially covered self-expandable metal stents (PCSEMSs) used in endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) remains unclear. This study investigated the safety and efficacy of PCSEMSs with different uncovered lengths, with a focus on stent migration and time to recurrent biliary obstruction (RBO). Methods: Outcomes of patients undergoing EUS-HGS using PCSEMSs with 5-mm and 20-mm uncovered portions at our institution from January 2016 to December 2021 were compared. Results: Sixty-two patients underwent EUS-HGS using PCSEMS (5/20-mm uncovered portions: 32/30). Stent migration occurred only in the 5-mm group. There were no differences in RBO rates (28.1% vs. 40.0%) or median time to RBO (6.8 vs. 7.1 months) between the two groups. Median overall survival (OS) was longer in the 20-mm group (3.1 vs. 4.9 months, p=0.037) due to the higher number of patients that resumed chemotherapy after EUS-HGS (56.7% vs. 28.1%, p=0.029). Good performance status, absence of hepatic metastases, and chemotherapy after EUS-HGS were independent predictors of longer OS. Conclusions: No migration was observed in patients treated with PCSEMS with 20-mm uncovered portions. Patients treated with PCSEMS with 20-mm uncovered portions performed at least as well as those treated with 5-mm uncovered portions in all material respects.