• Title/Summary/Keyword: $VS_2$

Search Result 6,984, Processing Time 0.034 seconds

Preliminary Study of Semi-continuous Liquid Recirculating Anaerobic Digestion for Source Separated Food Waste (음식물류 폐기물 처리를 위한 준 회분식 액순환 건식 혐기성 소화법에 대한 기초연구)

  • Cho, Chan-Hui;Lee, Byong-Hi
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.2
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, the experiment was carried out to produce methane by applying Semi-Continuous Leachate Recirculation Anaerobic Digestion System fed with source separated food waste from school cafeteria. There were two systems and each system consisted of a bioreactor and a liquid tank. Each bioreactor had a screen near the bottom of the reactor. 2.5L of separated liquid was transferred to the liquid tank for 30min each day by using a tubing pump and the liquid from the liquid tank was pumped to the bioreactor at the upper of the bioreactor as soon as the transfer was ended. Through this circulation, the liquid having high concentration of VFAs was supplied to the top of bioreactor. At the beginning of the experiment, food waste/inoculum anaerobic sludge volume ratio was 2:8 that is 9g VS/L of OLR(Organic Loading Rate). Feeding was conducted every two weeks. Experimental results showed that the contents of moisture, combustible matter, ash were 65.91%, 32.73%, and 1.36%, respectively. Two different food waste loading were studied. The average organic loading rates were 3.51g VS/d for System A and 3.86g VS/d for System B, respectively. The average produced methane based on food waste fed to bioreactor were observed as $6.30m^3CH_4/kgVS{\cdot}d$ for system A and $4.94m^3CH_4/kgVS{\cdot}d$ for System B, respectively.

Usefulness of Silent MRA for Evaluation of Aneurysm after Stent-Assisted Coil Embolization

  • You Na Kim;Jin Wook Choi;Yong Cheol Lim;Jihye Song;Ji Hyun Park;Woo Sang Jung
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.246-255
    • /
    • 2022
  • Objective: To determine the usefulness of Silent MR angiography (MRA) for evaluating intracranial aneurysms treated with stent-assisted coil embolization. Materials and Methods: Ninety-nine patients (101 aneurysms) treated with stent-assisted coil embolization (Neuroform atlas, 71 cases; Enterprise, 17; LVIS Jr, 9; and Solitaire AB, 4 cases) underwent time-of-flight (TOF) MRA and Silent MRA in the same session using a 3T MRI system within 24 hours of embolization. Two radiologists independently interpreted both MRA images retrospectively and rated the image quality using a 5-point Likert scale. The image quality and diagnostic accuracy of the two modalities in the detection of aneurysm occlusion were further compared based on the stent design and the site of aneurysm. Results: The average image quality scores of the Silent MRA and TOF MRA were 4.38 ± 0.83 and 2.78 ± 1.04, respectively (p < 0.001), with an almost perfect interobserver agreement. Silent MRA had a significantly higher image quality score than TOF MRA at the distal internal carotid artery (n = 57, 4.25 ± 0.91 vs. 3.05 ± 1.16, p < 0.001), middle cerebral artery (n = 21, 4.57 ± 0.75 vs. 2.19 ± 0.68, p < 0.001), anterior cerebral artery (n = 13, 4.54 ± 0.66 vs. 2.46 ± 0.66, p < 0.001), and posterior circulation artery (n = 10, 4.50 ± 0.71 vs. 2.90 ± 0.74, p = 0.013). Silent MRA had superior image quality score to TOF MRA in the stented arteries when using Neuroform atlas (4.66 ± 0.53 vs. 3.21 ± 0.84, p < 0.001), Enterprise (3.29 ± 1.59 vs. 1.59 ± 0.51, p = 0.003), LVIS Jr (4.33 ± 1.89 vs. 1.89 ± 0.78, p = 0.033), and Solitaire AB stents (4.00 ± 2.25 vs. 2.25 ± 0.96, p = 0.356). The interpretation of the status of aneurysm occlusion exhibited significantly higher sensitivity with Silent MRA than with TOF MRA when using the Neuroform Atlas stent (96.4% vs. 14.3%, respectively, p < 0.001) and LVIS Jr stent (100% vs. 20%, respectively, p = 0.046). Conclusion: Silent MRA can be useful to evaluate aneurysms treated with stent-assisted coil embolization, regardless of the aneurysm location and type of stent used.

Growth Efficiency, Carcass Quality Characteristics and Profitability of Finishing Pigs Slaughtered at 130 vs. 110Kg (110kg 대비 130kg에 도축된 비육돈의 성장효율, 도체 품질 특성 및 수익성)

  • 이철영;권오천;하덕민;신호원;이제룡;하영주;이진희;하승호;김원기;김광위;김두환
    • Journal of Animal Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.493-502
    • /
    • 2006
  • The slaughter weight (wt) is a most important economic factor in swine roduction. The present study was undertaken to determine if it is feasible to increase the slaughter wt of finishing pigs to 130kg without significantly affecting the growth efficiency and carcass quality. One hundred and sixty gilts and 160 barrows born from lean-type Yorkshire×Landrace (YL)-dam and Duroc (D)-sire lines, which are most widely used for terminal breeding for pork production in Gyeongsangnam-do, were randomly allocated into 16 pens under a 2 (sex)×2 (slaughter wt; 110 vs. 130kg) factorial arrangement of treatments. The animals were fed ad libitum a diet containing 3,200kcal DE/kg and 15.5% crude protein. After slaughter at the predetermined wt, yields of trimmed primal cuts and physicochemical characteristics of the longissimus dorsi muscle (LD) were measured or analyzed. Average daily gain was greater (P<0.01) in barrows than in gilts (0.86 vs. 0.79kg), but it was not different between the 110- and 130-kg slaughter wt groups (P>0.05). Backfat thickness was greater in the 130- vs. 110-kg group in both sexes (gilts: 21.6 vs. 17.6 mm, barrows: 25.1 vs. 20.8 mm). The yield percentage of belly was greater in barrows than in gilts (21.2 vs. 20.5%) and also in the 130-kg vs. 110-kg group (21.4 vs. 20.2%). Major physicochemical characteristics of LD including the color, percentage of 48-h drip loss, 24-h pH and percentages of crude protein and fat were not influenced by slaughter wt. Marginal profit of the 130-kg vs. 110-kg market pig was approximately 󰠏20,000 won/head, which resulted primarily from the heavy carcass weight of the former exceeding the upper limit of the A- or B-grade. However, if it had not been for the carcass weight limit of the current grading system, a 130-kg market pig would have had a potential marginal profit greater than 20,000 won. Results suggest that slaughter wt of lean-line finishing pigs can be increased to 130kg without significantly compromising the growth efficiency and carcass quality and accordingly, the upper weight limit of the ‘good-grade’ carcass needs to be increased or abolished to accommodate the larger market pigs.

Comparing the Intelligibility of Spastic and Flaccid Types (경직형과 이완형 마비말장애의 명료도 비교)

  • Kim Soo-Jin
    • MALSORI
    • /
    • no.48
    • /
    • pp.1-17
    • /
    • 2003
  • Among the types of dysarthria, spastic and flaccid types are the most prominent manifestations. The objectives of the present research are (1) to discover the phonetic contrasts that differentiate spastic dysarthria from flaccid dysarthria, (2) to analyze the degrees of predictability of each phonetic contrast for intelligibility in spastic and flaccid dysarthrias and to compare them. The 'phonemic contrast word intelligibility pairs' for dysarthric speakers were tested and proved to be useful for clinical assessment of and research on dysarthria. In the group of spastic type, it showed that initial fricative vs. affricate and front vs. back vowel contrasts are transmitted relatively less effectively than flaccid type. In the group of flaccid type, initial glottal vs null contrast is transmitted less effectively than spastic type. The overall intelligibility of spastic dysarthria was predicted by multiple regression analysis with 88% accuracy by three phonetic contrasts(initial fricative vs. affricate; front vs. back vowels; initial consonant correlates). And the intelligibility of flaccid dysarthria was predicted by two phonetic contrasts(initial nasal vs. stop, front vs. back vowels) with 60% accuracy.

  • PDF

Molecular Detection of Human Enteric Viruses in Urban Rivers in Korea

  • Lee, Cheong-Hoon;Kim, Sang-Jong
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.6
    • /
    • pp.1156-1163
    • /
    • 2008
  • We performed RT-nested PCR to study the distribution of human enteric viruses in urban rivers in Korea. During 2002-2003, water samples were collected from four rivers in Gyeonggi Province, South Korea. Among 58 samples, 45 (77.6%), 32 (55.2%), 12 (20.7%), 2 (3.4%), 4 (6.9%), and 4 (6.9%) showed positive results with adenoviruses (AdVs), enteroviruses (EVs), reoviruses (ReVs), hepatitis A viruses (HAVs), rotaviruses (RoVs), and sapoviruses (SVs), respectively. According to the binary logistic regression model, the occurrence of each enteric virus, except ReVs and HAVs, was not statistically correlated with the water temperature and levels of fecal coliforms (P<0.05). AdVs were most often detected; only 4 samples (6.9%) were negative for AdVs while positive for other enteric viruses in the studied sites. Our results indicated that monitoring human enteric viruses is necessary to improve microbial quality, and that AdVs detection by PCR can be a useful index for the presence of other enteric viruses in aquatic environments.

A Study for GnRH Antagonist (Cetrotide) Short Protocol in Controlled Ovarian Hyperstimulation (GnRH Antagonist (Cetrotide) Short Protocol의 임상적 유용성에 관한 연구)

  • Kim, Moon-Young;Jung, Byeong-Jun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.28 no.4
    • /
    • pp.265-270
    • /
    • 2001
  • Objective : The aim of this study was to evaluate the outcome the GnRH antagonist (Cetrotide) short protocol in controlled ovarian hyperstimulation comparing with GnRH agonist long protocol. Materials and Method: From July 2000 to November 2001, 26 patients, 28 cycles were performed in controlled ovarian hyperstimulation by GnRH antagonist and GnRH agonist. GnRH antagonist (Cetrotide) was administered in 12 patients (14 cycles, Group 1) and GnRH agonist (Lucrin, Sub Q, Group 2) in 14 patients (14 cycles). Ovulation induction was performed by hMG (Pergonal) in group 1, and by Combo (Metrodine HP + Pergonal) in group 2. We compared the fertilization rate, good quality embryo, and clinical pregnancy rate between the two groups. Student-t test and Chi-square were used to determine statistical significance. Statistical significance was defined as p<0.05. Results: Ovarian hyperstimulation syndrome did not occurred in which estradiol (E2) level was $3874{\pm}809\;pg/ml$ and the number of retrieved oocytes was $18.4{\pm}2.4$. The number of used gonadotropin ampules was significantly decreased in Group 1 (26.0 vs. 33.1, p<0.04). There were no significant difference in the number of preovulatory oocyte ($10.6{\pm}6.9$ vs. $10.0{\pm}6.1$), fertilization rate ($74.8{\pm}23.4$ vs. $72.2{\pm}21.8$), good quality embryo ($58.7{\pm}23.6$ vs. $38.7{\pm}36.6$), and embryo transfer ($4.3{\pm}1.6$ vs. $4.4{\pm}1.6$). Although the age of the group 1 was older than the group 2 (34.4 vs. 30.8), there was no significant difference in clinical pregnancy rate (50.0% vs. 57.1%). Conclusions: We suggest that GnRH antagonist was a safe, effective, and alternative method in the controlled ovarian hyperstimulation, especially in PCOD patients who will be develop the ovarian hyperstimulation syndrome.

  • PDF

Comparison of the Therapeutic Efficacy and Technical Outcomes between Conventional Fixed Electrodes and Adjustable Electrodes in the Radiofrequency Ablation of Benign Thyroid Nodules

  • Jae Ho Shin;Minkook Seo;Min Kyoung Lee;So Lyung Jung
    • Korean Journal of Radiology
    • /
    • v.25 no.2
    • /
    • pp.199-209
    • /
    • 2024
  • Objective: This study aimed to compare therapeutic efficacy and technical outcomes between adjustable electrode (AE) and conventional fixed electrode (FE) for radiofrequency ablation (RFA) of benign thyroid nodules. Materials and Methods: Between 2013 and 2021, RFA was performed on histologically proven benign thyroid nodules. For the AE method, AE length ≥ 1 cm with higher power and < 1 cm with lower power were utilized for ablating feeding vessels and nodules, especially those near anatomical structures, respectively. The therapeutic efficacy (volume reduction rate [VRR], complication rate, and regrowth rate) and technical outcomes (total energy delivery, ablated volume/energy, RFA time, and ablated volume/time) of FE and AE were compared. Continuous parameters were compared using a two-sample t-test or Mann-Whitney U test, and categorical parameters were compared using a chi-squared test or Fisher's exact test. Results: A total of 182 nodules (FE: 92 vs. AE: 90) in 173 patients (mean age ± standard deviation, 47.0 ± 14.7 years; female, 90.8% [157/173]; median follow-up, 726 days [interquartile range, 441-1075 days]) were analyzed. The therapeutic efficacy was comparable, whereas technical outcomes were more favorable for AE. Both electrodes demonstrated comparable overall median VRR (FE: 92.4% vs. AE: 84.9%, P = 0.240) without immediate major complications. Overall regrowth rates were comparable between the two groups (FE: 2.2% [2/90] vs. AE: 1.1% [1/90], P > 0.99). AE demonstrated a shorter median RFA time (FE: 811 vs. AE: 627 seconds, P = 0.009). Both delivered comparable median energy (FE: 42.8 vs. AE: 29.2 kJ, P = 0.069), but AE demonstrated higher median ablated volume/energy and median ablated volume/time (FE: 0.2 vs. AE: 0.3 cc/kJ, P < 0.001; and FE: 0.7 vs. AE: 1.0 cc/min, P < 0.001, respectively). Conclusion: Therapeutic efficacy between FE and AE was comparable. AE demonstrated better technical outcomes than FE in terms of RFA time, ablated volume/energy, and ablated volume/time.

Cytotaxonomic study of Korean Euphorbia L. (Euphorbiaceae) (한국산 대극속(Euphorbia L., Euphorbiaceae)의 세포분류학적 연구)

  • Chung, Gyu Young;Oh, Byoung-Un;Park, Ki-Ryong;Kim, Joo-Hwan;Kim, Mi Suk;Nam, Gi-Heum;Jang, Chang-Gee
    • Korean Journal of Plant Taxonomy
    • /
    • v.33 no.3
    • /
    • pp.279-293
    • /
    • 2003
  • Somatic chromosomes about 13 taxa of Korean Euphorbia L. was investigated to estimate its taxonomic significance. Somatic chromosome numbers of treated taxa were 2n= 12, 20, 22, 28, 40, 42, 56, therefore basic chromosome numbers of those were x=6, 7, 10, 11. The chromosome numbers of E. pallasii Turcz. (2n=20), E. hylonoma Hand.-Mazz (2n=20.), E. fauriei H. L$\acute{e}$v. & Vaniot ex H. L$\acute{e}$v (2n=28) and E. jolkini Boiss. (2n=28) were determined for the first time in this study. The chromosome numbers of four taxa were same as previous ones; E. sieboldiana Moor. & Decne. (2n=20), E. ebracteolata Hayata (2n=20), E. humifusa Willd. ex Schlecht. (2n=22). But those of six taxa were different; E. esula L (2n= 16, 20, 60, 64 vs 2n=20), E. helioscopia L. (2n=12, 42 vs 2n=42), E. lucorum Rupr. (2n=28, 40 vs 2n=56), E. pekinensis Rupr. in Maxim. (2n=24 vs 2n=28, 56), E. maculata L. (2n=28, 42 vs 2n=12), E. supina Raf. (n=7 vs 2n=40). E. ebracteolata, E. pallasii and E. hylonoma were distingushcd from the other taxa by the chromosome numbers, size and satellites, E. maculata, E. humifusa, E. supina had the different basic and somatic chromosome numbers in spite of the similar morphological. anatomical and palynological chracters. The chromosomal character of Korean Euphorbia was supported the Ma and Hu's systems, and as above results, it was found to be a good character in delimiting above sections and estimating relationships for some species.

PAX1 Methylation Analysis by MS-HRM is Useful in Triage of High-grade Squamous Intraepithelial Lesions

  • Wang, Zhen-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.891-894
    • /
    • 2014
  • This study is aimed to investigate the role of paired boxed gene 1 (PAX1) methylation analysis by methylation-sensitive high-resolution melting (MS-HRM) in the detection of high grade lesions in atypical squamous cells cannot exclude high-grade squamous intraepithelial lesion (ASC-H) and compared its performance with the Hybrid Capture 2 (HC2) human papillomavirus (HPV) test. In our study, 130 cases with a diagnosis of ASC-H from the cervical cytological screening by Thinprep cytologic test (TCT) technique were selected for triage. Their cervical scrapings were collected and evaluated by using PAX1 methylation analysis (MS-HRM) and high-risk HPV DNA test (HC2), followed by colposcopy and cervical biopsy. Chi-square test were used to test the differences of PAX1 methylation or HPV infection between groups. In the detection of CIN2+, the sensitivity, specificity, the PPV, NPV and the accuracy of PAX1 MS-HRM assay and high-risk HPV (HR-HPV) tests were respectively 80.6% vs 67.7%, 94.9% vs 54.5%, 83.3%, vs 31.8%, 94.0% vs 84.4%, and 91.5% vs 57.7%. The PAX1 MS-HRM assay proved superior to HR-HPV testing in the detection of high grade lesions (CIN2+) in ASC-H. This approach could screen out the majority of high grade lesion cases of ASC-H, and thus could reduce the referral rate to colposcopy.