• Title/Summary/Keyword: $TiUnite^{TM}$ 표면 처리

Search Result 3, Processing Time 0.014 seconds

A Retrospective Study of Survival Rate in single Brnemark TiUniteTM Implant (단일 치아 결손시 TiUniteTM 표면 처리한 임플란트의 생존율에 대한 후향적 연구)

  • Kim, Hye-Jin;Yang, Seung-Min;Kye, Seung-Beom;Shin, Seung-Yun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.267-277
    • /
    • 2009
  • Recently implant supported single crown is the popular treatment option to replace a single missing tooth. The purpose of this retrospective study was to analyze and evaluate the survival of implants with the $TiUnite^{TM}$ surface for single tooth replacement. From September 2002 to December 2006, 269 TiUniteTM surfaced implants were used in single tooth replacements at the Institute of Oral Health Science, Samsung Medical Center. Twenty one cases were excluded because of neighbor implants, missing records & short follow up period. Among 248 implants, the 129 implants (52.0%) were inserted in the maxilla and 119 (48.0%) in the mandible. One hundred implants placement (40.3%) were combined with guided bone regeneration, and 36 implants placement (14.5%) were combined with sinus bone augmentation. Mean observation period was $26.0{\pm}11.8$ months after implant placement. Twelve implants were recorded as failures, rendering a single implant survival rate of 95.2% over the observation period. Among failed 12 implants, 10 implants placed in the maxilla. The survival rate in the maxilla was 92.2% and in the mandible was 98.3%. The use of $TiUnite^{TM}$ surfaced single implant placement showed high survival rate for short time period.

A 3 year-retrospective study of survival rate in single $Br{\aa}nemark$ $TiUnite^{TM}$ implant (단일치아 결손시 $TiUnite^{TM}$ 표면처리한 임플란트의 생존율에 대한 후향적 단기연구)

  • Yang, Seung-Min;Park, Sun-Hye;Shin, Seung-Yun;Kye, Seung-Beom
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.671-679
    • /
    • 2007
  • Background: $TiUnite^{TM}$ is a highly crystalline and phosphate enriched titanium oxide surface which has a unique porous surface structure. This improved implant surface enhances bone response and reduces healing period. It also assures early stability of implant. These help to increase the success of implant. The aim of this study is to evaluate the survival rate of $TiUnite^{TM}$ surfaced single implant. Materials and methods: A retrospective analysis of 89 $TiUnite^{TM}$ surfaced implants replacing a single tooth was assessed according to their dental record. The age of the patients ranged from 17 to 82 years (mean age: $45.8{\pm}14.6)$. Data were recorded regarding the survival rate of these implants. Results: Fifty-two implants (57%) were placed in the maxilla, and 37 (43%) in the mandible. Over 75% were placed in the posterior area. Of the placed implants, 67% were the wide type. while 25% were the regular type and only 8% were of the narrow type. The single implants produced an overall clinical survival rate of 96.6% over the observation period (mean 17.9 months). Among 89 implants, only 2 implants were removed and one implant was submerged. Conclusion: According to these data, $TiUnite^{TM}$ surfaced implant in a single tooth restoration showed favorable survival rate although this study was done in a short term period.

Micromorphometric change of implant surface conditioned with tetracycline-HCI;HA and oxidized surface (표면처리 시간에 따른 임플란트 미세구조의 변화;HA와 양극산화 표면 임플란트)

  • An, Sang-Ho;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.891-905
    • /
    • 2005
  • The present study was performed to evaluate the effect of tetracycline-HCL on the change of implant surface microstructure according to application time. Implant with pure titanium machined surface. HA-coated surface and TiUniteTM surface were utilized. Implant surface was rubbed with 50mg/ml tetracycline-HCL solution for $\frac{1}{2}min.$, 1min., $1\frac{1}{2}min.$, 2min., and $2\frac{1}{2}min.$ respectively in the test group. Then, specimens were processed for scanning electron microscopic observation. The results of this study were as follows. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In HA-coated surfaces, round particles were deposited irregularly. The roughness of surfaces conditioned with tetracycline-HCL was lessened and the cracks were increased relative to the application time. 3. The anodic oxidized surfaces showed the craterous structures. The surface conditioning with tetracycline-HCl didn't influence on its micro-morphology. In conclusion, the detoxification with 50mg/ml tetracycline-HCL must be applied respectively with different time according to various implant surfaces.