• Title/Summary/Keyword: $Tan\delta$

Search Result 521, Processing Time 0.023 seconds

A study on the dielectric dispersion of vulcanized natural rubber (가황에 의한 천연고무의 유전분산에 관한연구)

  • Lee, Joon-Ung;Kim, Hak-Ju
    • Elastomers and Composites
    • /
    • v.18 no.2
    • /
    • pp.51-59
    • /
    • 1983
  • The dielectric properties of polymers are very important when investigating the molecular structure of polymers. The characteristics of the dielectric absorption in vulcanized natural rubber were studied in frequency ranging from 10[KHz] to 32[MHz] at the temperature of 25[$^{\circ}C$]. As a result of the study, it has been confirmed that natural rubber vulcanized below 4phr leads to two kinds of dielectric losses due to the interfacial polarization and the dipole polarization by sulfur, and of above 7[%] was only a loss due to the dipole polarization by sulfur. Futhermore, the dielectric loss maximum $tan{\delta}$ spectrum, removed to the low frequency in accordance with increasing sulfur, depends greatly on sulfur. The volume resistivity of $10^{7}{\sim}10^{11}[{\Omega}{\cdot}cm}]$, regardless of whether the crosslinking of rubber is weakened by sulfur, was observed.

  • PDF

A study on the dielectric dispersion phenomena due to thermal aging of polypropylene film (폴리플로필렌 필름의 열노화에 의한 유전완화현상에 관한 연구)

  • 이준웅;김용주;이상석
    • Electrical & Electronic Materials
    • /
    • v.1 no.1
    • /
    • pp.54-61
    • /
    • 1988
  • This paper was a study on dielectric phenomena of the specimen, Polypropylene films which were annealled in air and quenched in liquid nitrogen after aging for 5[hr] in water of 100[.deg.C]. The specimen was measured in temperature range of 15-120[.deg.C] and in frequency range of 30-1x 10$^{6}$ [HZ]. As the results of the study, it was confirmed that the tacticity of specimen was isotactic structure, and the degree of cryatallinity of the specimens calculated by means of Natta's method from XRD (X-ray Diffraction) spectrum was 55[%]. And for dielectric relaxation, .betha. peak-the tan .delta. (spectrum around 20[.deg.C])-attributed due to amorphous regions, and .alpha. peak - the tan .delta. spectrum around 90[.deg.C]-due to crystalline regions. It was identified that the degree of crystallinity of the specimen quenched in the liquid nitrogen was increased to 55-65[%], and that of the specimen annealled in the air was decreased to 55-50[%]. And activation energy from dielectric loss spectra was obtained 34.5[kcal/mole] for .alpha. peak and 80.5[kcal/mole] for .betha. peak, respectively.

  • PDF

Thermal Properties of Chloroprene Rubber with $^{60}Co\;{\gamma}$-ray Irradiation ($^{60}Co\;{\gamma}$-선 조사에 따른 클로프렌 고무의 열적 특성)

  • Kim, Ki-Yup;Lee, Chung;Ryu, Boo-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.64-70
    • /
    • 2003
  • The thermal properties of chloroprene rubber (CR) with $^{60}Co\;{\gamma}$-ray irradiation has been investigated. The prepared CR was irradiated up to 1000kGy radiation dose by $^{60}Co\;{\gamma}$-ray and the radiation degradation of CR was investigated by thermogravimetric analysis and differential acanning calorimetry. Dynamic mechanical properties measurement and FT-IR observation are carried out as well. From these analyses results, the glass transition temperature($T_g$), decomposition onset temperature(DOT), oxidative induction time(OIT), the peak temperature of loss modulus and mechanical tan ${\delta}$ values were compared for the radiation degradation level of CR. The tendency between $T_g$ and peak temperature of loss modulus and mechanical tan ${\delta}$ agreed well with radiation doses. Decomposition temperature, OIT and DOT showed the same tendencies as increasing radiation doses. It was verified that these analyses are available to estimate the degradation level of CR.

Research of Tan$\delta$ Measurement on Pole Transformers using DSP (DSP를 이용한 주상변압기 유전정접 측정기법 연구)

  • 김재철;이보호;김언석;최도혁;이수길
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.11 no.2
    • /
    • pp.110-118
    • /
    • 1997
  • This paper describes the dissipation factor measuring techniques of insulating oil on operating pole transformers by using digital signal processor. After applying voltage to the condenser which is in¬stalled in a transformer, acquiring source voltage and current of condenser and using cross-correla¬tion techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and software such as cross -correlation techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with Schering bridge on degraded insulating oil. The result showed that this measuring tech¬nique can be used as diagnostic method on the pole transformers.

  • PDF

Piezoelectric properties of Pb(Sb,Mn) $O_3$- Pb(Zr,Ti) $O_3$ Ceramics doped L $u_2$ $O_3$ (L $u_2$ $O_3$ 치환에 따른 Pb(Sb,Mn) $O_3$-Pb(Zr,Ti) $O_3$ 세라믹스의 압전특성)

  • ;;Sergey Kucheiko
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.60-63
    • /
    • 1997
  • Dieletric ailed piezoelectric properties of Pb[$Zr_{0.45}$/ $Ti_{0.5-x}$/L $u_{x}$ (M $n_{1}$3//S $b_{2}$3)$_{0.05}$] $O_3$(0$\leq$x $\leq$0.03) were investigated. The partial substitution of $Ti^{4+}$ by a L $u^{3+}$ permitted improvement of the piezoelectric constant( $d_{33}$ ), electromechanical coupling factor ( $k_{p}$ ) and dielectric constant($\varepsilon$$_{33}$ /Sup T/). The dielectric loss(tan $\delta$ ) increased and mechanical quality factor(Qm) decreased with an increase of x were observed. A new piezoelectric material for actuator application was developed at x=0.02 with $d_{33}$ =370$\times$10$^{-2}$ /C/N, $k_{p}$ =58.5%, $\varepsilon$$_{33}$ $^{T}$ =1321, $Q_{m}$ =714 and tan $\delta$ =0.98%.%..%.%.

  • PDF

Research of $tan{\delta}$ Measurement on Pole Transformer Using DSP (DSP를 이용한 주상변압기 $tan{\delta}$ 측정기법 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Yoon, Yong-Han;Rim, Sung-Jung;Kim, Oun-Seok;Lee, Su-Kil
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.462-463
    • /
    • 1996
  • This study describes the dissipation factor measuring techniques of insulating oil on the operating, transformer by using digital signal processing. After applying voltage to the sensor which is installed in a transformer, acquiring source voltage and current of sensor and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and analog filter and software such as fast cross-correlation techniques, rectangular window, and digital filtering techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by computer simulation, and compared the simplified measuring devices with Schering Bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Research of $Tan{\delta}$ Measurement on pole Transformer Using DSP (DSP를 이용한 주상변압기 $Tan{\delta}$ 측정기법 연구)

  • Lee, Bo-Hoo;Kim, Jae-Chul;Lee, Su-Kil;Yoon, Yong-Han;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.270-272
    • /
    • 1996
  • This paper describes the dissipation factor measuring techniques of insulating oil on operating pole transformer by using digital signal processor. After applying voltage to the electrodes which is installed in a transformer, acquiring source voltage and current of electrodes and using cross-correlation techniques, we can check the dissipation factor of insulating oil. To improve measuring accuracy and the speed of process, we use hardware such as TMS320C31 DSP board and software such as cross-correlation techniques and rectangular window techniques. We simulated the measuring accuracy and the degree of the noise effect of this new measuring techniques by using computer simulation, and compared the simplified measuring devices with schering bridge on degraded insulating oil. The result showed that this measuring technique can be used as diagnostic method on the pole transformers.

  • PDF

Microwave Absorption Properties in Composite Microwave Absorberby Control of Preparing Temperature (복합형 전파흡수체에 있어 시편제작 온도에 따른 전파흡수 특성)

  • 송재만;김동일;김수정;옥승민;문상현;신승재
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.97-101
    • /
    • 2003
  • Mn-Zn ferrite microwave absorbers mixed with silicon for mobile phone were prepared and the effect of preparation temperature of specimens on absorption ability was studied. A sample with the thickness of 1 mm prepared at 70 $^{\circ}C$ showed excellent absorption ability of 3.4 ㏈ at 1.8 GHz which is a frequency band for mobile phone. A loss factor of tan $\delta$ > 1 is shifted toward lower frequency as increasing preparation temperature of specimens.

  • PDF

Dielectric Properties Depending on Temperature in Organic Light-emitting Diodes(ITO/$AIq_3$/AI) (유기 발광 다이오드(ITO/$AIq_3$/AI)의 온도 변화에 따른 유전 특성)

  • Oh, Y.C.;Lee, D.K.;Cho, C.N.;Ahn, J.H.;Jeong, Dong-Hui;Lee, S.I.;Kim, G.Y.;Kim, T.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.74-75
    • /
    • 2006
  • We have investigated dielectric properties depending on temperature in organic light-emitting diodes using 8-hydroxyquinoline aluminum ($Alq_3$) as an electron transport and emissive material. We analyzed the dielectric properties of organic light-emitting diodes using characteristics of impedance. he Impedance characteristics was measured complex impedance Z and phase $\theta$ in the temperature range of 10 K to 300 K. We obtained complex electrical conductivity, dielectric constant and loss tangent ($tan{\delta}$) of the device at room temperature. From these analyses, we are able to interpret a conduction mechanism and dielectric properties contributed by an interfacial and orientational polarization.

  • PDF

Effect of the Injection Parameters on Diesel Spray Characteristics

  • Song Kyu Keun;Sim Sang Cherl;Jung Byong Koog;Kim Hyung Gon;Kim Jang Heon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.1321-1328
    • /
    • 2005
  • The characteristics of the diesel spray have affected certain aspects of engine performance, such as the power, fuel consumption, and emissions. Therefore, this study was performed to investigate the effects of various injection parameters. In order to obtain the effect of injection parameters on diesel spray characteristics, the experiment is performed by using a high temperature and pressure chamber. The behaviors of the spray are visualized by using a high speed video camera, spray angle, penetration, and various other things. The results of the experiment are summarized as follows. (1) The correlation of the spray penetration can be expressed as follows. $$0< t $$t_{b} (2) The correlation of the spray angle can be expressed as follows $$T_a=293K\;tan({\theta}/2)=0.59({\rho}a/{\rho}f)^{0.437}$$ $$T_a=473K\;tan({\theta}/2)=0.588({\rho}a/{\rho}f)^{0.404}$$ (3) The measured macro characteristics that include the spray tip penetration and spray angle corresponded with the established correlations.