• Title/Summary/Keyword: $T_2$ contrast

Search Result 1,031, Processing Time 0.029 seconds

Signal Change of Normal Saline by Oxygen Injection in FLAIR Image (산소주입에 의한 FLAIR 영상에서 생리식염수의 신호 변화)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.55-63
    • /
    • 2019
  • It was reported that there were some cases in which signal was not inhibited but high signal appeared in cerebrospinal fluid on FLAIR(fluid attenuated inversion recovery) of MRI(Magnetic Resonance Imaging) in case a person inhales high-concentration oxygen. This study was to prepare basic database. We produced a phantom fixed with agar gel and by using it, obtained the images of the signals of normal saline into which oxygen was injected and normal saline diluted with contrast media by changing the TI(Inversion Time) of FLAIR technique and analyzed them. In the result of FLAIR technique of MRI using Philips Achieva MR 3.0T in Busan P Hospital, the SNR(Signal to Noise Ratio) of normal saline into which oxygen was injected was higher than the SNR of normal saline into which oxygen was not injected. However, it was not higher than the SNR of normal saline diluted with contrast media. In the TI 1,800ms, we could obtain the images which do not have the rise of the signal due to oxygen. In the CNR(Contrast to Noise Ratio) of normal saline into which oxygen was injected and normal saline diluted with contrast media as well, it was higher in the TI 1,800ms than in the TI 2,800ms that is mainly used clinically. It is thought that the result of this study could be basic database for studies on change of signal of cerebrospinal fluid as a result of injection of oxygen in FLAIR technique of MRI.

Blood-Brain Barrier Experiments with Clinical Magnetic Resonance Imaging and an Immunohistochemical Study

  • Park, Jun-Woo;Kim, Hak-Jin;Song, Geun-Sung;Han, Hyung-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.3
    • /
    • pp.203-209
    • /
    • 2010
  • Objective : The purpose of study was to evaluate the feasibility of brain magnetic resonance (MR) images of the rat obtained using a 1.5T MR machine in several blood-brain barrier (BBB) experiments. Methods : Male Sprague-Dawley rats were used. MR images were obtained using a clinical 1.5T MR machine. A microcatheter was introduced via the femoral artery to the carotid artery. Normal saline (group 1, n = 4), clotted autologous blood (group 2, n = 4), triolein emulsion (group 3, n = 4), and oleic acid emulsion (group 4, n = 4) were infused into the carotid artery through a microcatheter. Conventional and diffusion-weighted images, the apparent coefficient map, perfusion-weighted images, and contrast-enhanced MR images were obtained. Brain tissue was obtained and triphenyltetrazolium chloride (TTC) staining was performed in group 2. Fluorescein isothiocyanate (FITC)-labeled dextran images and endothelial barrier antigen (EBA) studies were performed in group 4. Results : The MR images in group 1 were of good quality. The MR images in group 2 revealed typical findings of acute cerebral infarction. Perfusion defects were noted on the perfusion-weighted images. The MR images in group 3 showed vasogenic edema and contrast enhancement, representing vascular damage. The rats in group 4 had vasogenic edema on the MR images and leakage of dextran on the FITC-labeled dextran image, representing increased vascular permeability. The immune reaction was decreased on the EBA study. Conclusion : Clinical 1.5T MR images using a rat depicted many informative results in the present study. These results can be used in further researches of the BBB using combined clinical MR machines and immunohistochemical examinations.

Clinical Experience with 3.0 T MR for Cardiac Imaging in Patients: Comparison to 1.5 T using Individually Optimized Imaging Protocols (장비 별 최적화된 영상 프로토콜을 이용한 환자에서의 3.0T 심장 자기공명영상의 임상경험: 1.5 T 자기공명영상과의 비교)

  • Ko, Jeong Min;Jung, Jung Im;Lee, Bae Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.83-90
    • /
    • 2013
  • Purpose : To report our clinical experience with cardiac 3.0 T MRI in patients compared with 1.5 T using individually optimized imaging protocols. Materials and Methods: We retrospectively reviewed 30 consecutive patients and 20 consecutive patients who underwent 1.5 T and 3 T cardiac MRI within 10 months. A comparison study was performed by measuring the signal-to-noise ratio (SNR), the contrast-to-noise ratio (CNR) and the image quality (by grading each sequence on a 5-point scale, regarding the presence of artifacts). Results: In morphologic and viability studies, the use of 3.0 T provided increase of the baseline SNRs and CNRs, respectively (T1: SNR 29%, p < 0.001, CNR 37%, p < 0.001; T2-SPAIR: SNR 13%, p = 0.068, CNR 18%, p = 0.059; viability imaging: SNR 45%, p = 0.017, CNR 37%, p = 0.135) without significant impairment of the image quality (T1: $3.8{\pm}0.9$ vs. $3.9{\pm}0.7$, p = 0.438; T2-SPAIR: $3.8{\pm}0.9$ vs. $3.9{\pm}0.5$, p = 0.744; viability imaging: $4.5{\pm}0.8$ vs. $4.7{\pm}0.6$, p = 0.254). Although the image qualities of 3.0 T functional cine images were slightly lower than those of 1.5 T images ($3.6{\pm}0.7$ vs. $4.2{\pm}0.6$, p < 0.001), the mean SNR and CNR at 3.0 T were significantly improved (SNR 143% increase, CNR 108% increase, p < 0.001). With our imaging protocol for 3.0 T perfusion imaging, there was an insignificant decrease in the SNR (11% decrease, p = 0.172) and CNR (7% decrease, p = 0.638). However, the overall image quality was significantly improved ($4.6{\pm}0.5$ vs. $4.0{\pm}0.8$, p = 0.006). Conclusion: With our experience, 3.0 T MRI was shown to be feasible for the routine assessment of cardiac imaging.

Application of Transfer Insensitive Labeling Technique (TILT) in Ischemic Cerebrovascular Diseases

  • 이승구;김동익;김상흠;김시연;인연권
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.169-169
    • /
    • 2001
  • Purpose: To assess the clinical usefulness of Transfer Insensitive Labeling Technique (TILT) in t evaluation of ischemic cerebrovascular disease. Method: Arterial spin labeling (ASL) is a method of perfusion weighted imaging usin endogenous water as a tracer. To avoid MT-related artifacts, which is common in usual A technique, a transfer insensitive labeling technique (TILT) was used, which globall manipulate macromolecular spins in the same way by both labeling and reference preparatio while free water is labeled in one case and left unchanged in the other. Philips Interal 1.5 T system was used. 40cm FOV and 32 repeated measurements were done because of the wea perfusion signal. 5 slices of supratentorial brain were obtained in 5 patients {MCA infar (n=3), moyamoya disease (n=2)}. We simultaneously obtained contrast enhanced T2*-weighted perfusion MRI and correlate to TILT images.

  • PDF

Ramsay Hunt Syndrome Complicated by Meningoencephalitis and Radiologic findings: a Rare Case Report

  • Lee, Youdae;Lee, Donghoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.1
    • /
    • pp.65-69
    • /
    • 2019
  • Ramsay Hunt syndrome with the complication of encephalitis or meningoencephalitis is rarely reported and uncommon in immunocompetent patients. The radiological manifestations of such cases usually involve the cerebellum and brainstem or exhibit the absence of any abnormality. We report a case of a 78-year-old immunocompetent man hospitalized with Ramsay Hunt syndrome, who later developed meningoencephalitis. The cerebrospinal fluid-study excluded other causes of meningoencephalitis, and the clinical diagnosis indicated varicella zoster virus meningoencephalitis. Magnetic resonance imaging revealed increased signal intensities in the bilateral temporal lobe, midbrain, and pons on T2-weighted imaging, and T2 fluid attenuated inversion recovery and contralateral asymmetric pachymeningeal enhancement. Contrast-enhanced T1-weighted imaging revealed ipsilateral facial nerve enhancement.

MR Imaging of Shaken Baby Syndrome Manifested as Chronic Subdural Hematoma

  • Yul Lee;Kwan Seop Lee;Dae Hyun Hwang;In Jae Lee;Hyun Beom Kim;Jae Young Lee
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.171-174
    • /
    • 2001
  • Shaken baby syndrome (SBS) is a form of child abuse that can cause significant head injuries, of which subdural hematoma (SDH) is the most common manifestation. We report the MRI findings of chronic SDH in three cases of SBS, involving two-, three- and eight-month-old babies. The SDH signal was mostly low on T1-weighted images and high on T2-weighted images, suggesting chronic SDH. In chronic SDH, a focal high signal on T1-weighted images was also noted, suggesting rebleeding. Contrast-enhanced MRI revealed diffuse dural enhancement.

  • PDF

Serum Thyroxine to Thyroxine-Binding Globulin Ratio in Pregnancy and Newborn (신부(娠婦)와 신생아(新生兒)에서 혈청(血淸)Thyroxine/Thyroxine-Binding Globulin 비(比))

  • Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.2
    • /
    • pp.59-61
    • /
    • 1982
  • To evaluate the diagnostic value of the ratio of serum tyroxine$(T_4)$/thyroxine-binding globulin (TBG) for the thyroid status in pregnancy and newborn serum thyroxine, TBG, triiodothyronine, and free thyroxine levels were radioimmunoassayed in normal pregnant women at each of the trimesters, and the calculated serum $T_4/TBG$ ratios were compared with other parameters such as $T_3/TBG$ ratio and free $T_4/TBG$ ratio and free $T_4/TBG$ ratio. Serum $T_4$ levels were elevated with the propotionate increase in TBG levels during pregnancy, leading to the nearly constant value of serum $T_4/TBG$ ratios as in normal non-pregnant controls. In contrast, serum $T_3/TBG$ and free $T_4/TBG$ ratios varied considerably during pregnancy. In newborn, $T_4$ levels were nearly not changed with compared non-pregnant control value and TBG levels were elevated. The results indicate that serum $T_4/TBG$ ratio is a better parameter than others in evaluating the thyroid status during pregnancy and but newborn is a no better.

  • PDF

A Study on Optimized MRI Fat-Saturation Technique for Brachial Plexus Patients : Focused on SPAIR and STIR Fat-Saturation (상완신경총 환자에서 최적의 자기공명영상 지방소거 기법에 관한 연구 : SPAIR, STIR 지방소거 중심으로)

  • Goo, Eunhoe
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.271-278
    • /
    • 2014
  • The purpose of this study is to know optimized fat suppression techniques for brachial plexus compared with STIR and SPAIR T1, T2 techniques. A total of 30 normal volunteers without brachial plexus disease were studied on a 3.0 T MRI scanner. As an analytical method, SNR, CNR, 4-point grading scale were evaluated by using three pulse sequences. As a quantitative analysis, the SNR, CNR for SPAIR T1 technique provided high value in branchial plexus roots (03.07, -2.25), branchial plexus trunks(06.70, 36.31)(p<0.05). As a qualitative Analysis, The visibility for delineation of brachial plexus, fat suppression, artifact was significantly better on SPAIR T1(3.2, 3.6, 3.4) technique(p<0.05).

Effects of T-2 Toxin, Zeolite and Mycosorb on Antioxidant Systems of Growing Quail

  • Dvorska, J.E.;Surai, P.F.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.12
    • /
    • pp.1752-1757
    • /
    • 2001
  • The present study was conducted to assess the dietary effect of T-2 toxin on the antioxidant systems of the liver in growing quail and to comparatively evaluate the protective properties of two different mycotoxin-adsorbent additives, Mycosorb and zeolite, in preventing inhibition of the antioxidant system. Four groups of 4 day old quail were formed with 20 birds in each group. The birds were maintained on the floor for the course of the study. The three treatment diets consisted of the basal diet with T-2 toxin added in the form of Fusarium sporotrichioides culture (8.1 mg/kg feed), T-2 toxin (8.1 mg/kg) plus zeolite (30 g/kg feed), and T-2 toxin (8.1 mg/kg) plus Mycosorb (1 g/kg feed). After 30 days of feeding (34 days old) all birds were sacrificed and liver samples for biochemical analyses were collected from five quail in each of the four groups. Antioxidant concentrations were evaluated by HPLC-based methods. Inclusion of T-2 toxin in the quail diet was associated with a significant (p<0.05) decrease in concentrations of all forms of antioxidants studied, including ${\alpha}$- and ${\gamma}$-tocopherols, ascorbic acid, retinol and retinyl esters. At the same time, liver susceptibility to lipid peroxidation significantly (p<0.05) increased. Inclusion of zeolite in the quail diet at the level of 3% was ineffective in preventing antioxidant depletion in the liver by mycotoxicosis. In contrast, Mycosorb in the diet at a 0.1% level was able to significantly inhibit liver antioxidant depletion and as a result decreased lipid peroxidation in the liver. Concentrations of all forms of antioxidants studied were significantly higher in the livers of the quails fed the basal and T-2 toxin/Mycosorb combination in comparison to birds fed the basal with T-2 toxin alone.

The Evaluation of Image Correction Methods for SPECT/CT in Various Radioisotopes with Different Energy Levels (SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가)

  • Shin, Byung Ho;Kim, Seung Jeong;Yun, Seok Hwan;Kim, Tae Yeop;Lim, Jung Jin;Woo, Jae Ryong;Oh, So Won;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.53-58
    • /
    • 2013
  • Purpose: To optimize correction method for SPECT/CT, image quality consisting of resolution and contrast was evaluated using three radioisotopes ($^{99m}Tc$, $^{201}Tl$ and $^{131}I$) and three different correction methods; attenuation correction (AC), scatter correction (SC) and both attenuation and scatter correction (ACSC). Materials and Methods: Images were acquired with a SPECT/CT scanner and a conventional CT protocol with an OESM reconstruction algorithm (2 iterations and 10 subsets). For resolution measurement, fixed radioactivity (2.22 kBq) was infused into a spatial resolution phantom and full width at half maximum (FWHM) was measured using a vendor-provided software. For contrast evaluation, radioactive source with a ratio of 1:8 to background was filled in a Flanged Jaszczak phantom and percent contrast (%) were calculated. All the parameters for image quality were compared with non-correction (NC) method. Results: As compared with NC, image resolution of all three isotopes were significantly improved by AC and ACSC, not by SC. In particular, ACSC showed better resolution than AC alone for $^{99m}Tc$ and $^{201}Tl$. Image contrast of all three radioisotopes in a sphere with the largest diameter were enhanced by all correction methods. ACSC showed the highest contrast in all three radioisotopes, which was the most accurate in $^{99m}Tc$ (85.9%). Conclusion: Image quality of SPECT/CT was improved in all the radioisotopes by CT-based attenuation correction methods, except SC alone. SC failed to improve resolution in any radioisotopes, but it was effective in contrast enhancement. ACSC would be the best correction method as it improved resolution in radioisotopes with low energy levels and contrast in radioisotope with low energy levels. However, in radioisotope with high energy level, AC would be better than ACSC for resolution improvement.

  • PDF