• Title/Summary/Keyword: $Sb_6O_{13}$

Search Result 27, Processing Time 0.025 seconds

Electrochemical treatment of cefalexin with Sb-doped SnO2 anode: Anode characterization and parameter effects

  • Ayse, Kurt;Hande, Helvacıoglu;Taner, Yonar
    • Advances in nano research
    • /
    • v.13 no.6
    • /
    • pp.513-525
    • /
    • 2022
  • In this study, it was aimed to evaluate direct oxidation of aqueous solution containing cefalexin antibiotic with new generation Sn/Sb/Ni: 500/8/1 anode. The fact that there is no such a study on treatment of cefalexin with these new anode made this study unique. According to the operating parameters evaluation COD graphs showed clearer results compared to TOC and CLX and thus, it was it was chosen as major parameter. Furthermore, pseudo-first degree kd values were calculated from CLX results to show more accurate and specific results. Experimental results showed that after 60 min of electrochemical oxidation, complete removal of COD and TOC was accomplished with 750 mg L-1 KCl, at pH 7, 50 mA cm-2 current density and 1 cm anode-cathode distance. Also, the stability of the Sn/Sb/Ni anode was evaluated by taking SEM and AFM images and XRD analysis before and after of electrochemical oxidation processes. According to the results, it was not occurred too much change on the anode surface even after 300 h of electrolysis. Thus, it was thought that the anode material was not corroded to a large extent. Furthermore, the removal efficiencies were very high for almost all the time and conditions. According to the results of the study, electrochemical oxidation with new generation Sn/Sb/Ni anodes for the removal of cefalexin antibiotic was found very successful and applicable due to require less reaction time complete mineralization and doesn't require pH adjustment step compared to other studies in literature. In future studies, different antibiotic types should be studied with this anode and maybe with real wastewaters to test applicability of the process in treatment of pharmaceutical wastewaters containing antibiotics, in a better way.

THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES ON PRIMARY AND PERMANENT TEETH (유치와 영구치에서 치과용 접착제의 전단결합강도)

  • Choi, Jin-Young;Choi, Nam-Ki;Park, Yeong-Joon;Choi, Choong-Ho;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.579-589
    • /
    • 2007
  • The objective of this study was to compare the shear bond strengths of five adhesive systems to the enamel and dentin of primary and permanent teeth. Fifty noncarious primary and fifty permanent teeth were collected and stored in an 0.1% thymol solution at room temperature after extraction. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM) Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL), GBond (GB). For the shear bonding test, the labial and lingual surfaces of primary and permanent teeth were used. To obtain a flat surface, the labial and lingual surfaces of the teeth were sanded on $SiO_2$ with number 600 grit and then divided into 20 groups of 10 surfaces each. All samples were theromocycled in water $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles. The results were as follows: 1. For primary enamel, shear bond strengths of SM and SB were significantly higher than that of SE and also SM, SB, and PL were higher than GB(p<0.05). 2. For primary dentin, there were no significant differences among the shear bond strengths of any other bonding systems except difference between SE and GB. 3. For permanent enamel, SB showed significantly higher mean shear bond strength than those of any other bonding systems(p<0.05). 4. For permanent dentin, SM showed significantly higher mean shear bond strength than that of PL and GB(p<0.05). 5. Between the primary enamel and dentin, there were significant differences in SM, SB, and GB, whereas there was statistically significant difference in PL between the permanent enamel and dentin(p<0.05). 6. Between the primary and permanent teeth on enamel, there were no significant differences among all bonding systems, whereas there were statistically significant differences in SM and SB between the primary and permanent teeth on dentin(p<0.05).

  • PDF

Effects of Sb doping on the Characteristis of $SnO_2$ Transparent Electrodes ($SnO_2$ 수용전극특성에 미치는 Sb첨가의 영향)

  • 이정한
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.13 no.3
    • /
    • pp.16-21
    • /
    • 1976
  • Transparent eloctroaes of polycrystalline till-oxide films doped with antimony are prepared on the substrate of microscopic cover g1ass by modified spray method and from SnCl4 Solution. Their electrical and optical properties are investigated in relation to the surface temperature of the substrate glass and to antimony concentration in the starting materials. The sheet.resiststrace of the film electrodes and transmittance for incandescent light depen on tile antimony concentration and surface temperature of substrates at the time of making films. The transmittance increases with decrease of sheet resistance of the film. The optimum sheet.resistance was obtianed in the case of the antimony concentration 0.6(%) approximately , and the max. transmittance was 93(%).

  • PDF

Carbon이 첨가된 Ge-doped SbTe 상변화재료의 박막 및 소자 특성

  • An, Hyeong-U;Park, Yeong-Uk;O, Cheol;Jang, Gang;Jeong, Jeung-Hyeon;Lee, Su-Yeon;Jeong, Du-Seok;Kim, Dong-Hwan;Jeong, Byeong-Gi
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.55-55
    • /
    • 2011
  • 질소 등을 GST225 상변화재료에 첨가시켜 비저항을 증가시킴으로서 PCRAM의 동작 전류를 감소시킨 연구가 선행된 바 있다. 본 연구에서는 GST225와 달리 고속 동작 특성을 갖는 것으로 널리 알려진 Ge-doped SbTe (GeST) 상변화 재료에 Carbon을 첨가하여 박막 특성을 연구하여 동작 전류 감소의 가능성을 타진하였다. 실험을 위한 박막 제작을 위해 2 inch size의 GeST 및 C doped GeST (C-GeST) single target을 이용하여 RF magnetron co-sputtering 하였다. 박막은 carbon이 첨가되지 않은 GeST와 carbon 첨가량이 늘어나는 순서로 C-GeST 1, C-GeST 2, C-GeST 3로 구성된다. 이 때 제작한 박막의 composition analysis를 위해 XRF/RBS/AES가 사용되었고 제작된 박막의 기본적인 특성평가를 위해 resistivity(${\rho}$)와 crystallzation temp.(Cx), surface morphology(AFM), x-ray diffraction pattern(XRD)를 측정하였다. 실험결과 GeST, C-GeST 1, C-GeST 2, C-GeST 3 박막의 Cx는 각각 209, 225, 233, $245^{\circ}C$로 측정되어 carbon 첨가량이 증가됨에 따라 결정화 온도가 증가되는 것을 알 수 있었다. 또한 ${\rho}$도 마찬가지로 annealing 온도를 약 $320^{\circ}C$로 할 경우 ${\rho}$(as-dep)와 ${\rho}$(crystalline) 모두 0.03 / $2.61*10^{-6}$, 0.08 / $7.93*10^{-6}$, 0.09 / $11.99*10^{-6}$, 0.13 / $13.49*10^{-6}{\Omega}{\cdot}m$로 증가하였다. 증가된 ${\rho}$의 원인이 박막의 grain size의 감소라고 단언 할 수는 없으나 AFM 측정결과 grain이라고 추측되는 박막 feature들의 size가 점차 감소하는 것을 확인하였다.

  • PDF

How will surface treatments affect the translucency of porcelain laminate veneers?

  • Turgut, Sedanur;Bagis, Bora;Ayaz, Elif Aydogan;Korkmaz, Fatih Mehmet;Ulusoy, Kivanc Utku;Bagis, Yildirim Hakan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.8-13
    • /
    • 2014
  • PURPOSE. The purpose of this study was to evaluate whether surface treatments affect the translucency of laminate veneers with different shades and thicknesses. MATERIALS AND METHODS. A total of 224 disc-shaped ceramic veneers were prepared from A1, A3, HT (High Translucent) and HO (High Opaque) shades of IPS e.max Press (Ivoclar Vivadent) with 0.5 mm and 1.0 mm thicknesses. The ceramics were divided into four groups for surface treatments. Group C: no surface treatments; Group HF: etched with hydrofluoric acid; Group SB: sandblasted with 50-${\mu}m$ $Al_2O_3$; and Group L; irradiated with an Er;YAG laser. A translucent shade of resin cement (Rely X Veneer, 3M ESPE) was chosen for cementation. The color values of the veneers were measured with a colorimeter and translucency parameter (TP) values were calculated. A three-way ANOVA with interactions for TP values was performed and Bonferroni tests were used when appropriate (${\alpha}=0.05$). RESULTS. There were significant interactions between the surface treatments, ceramic shades and thicknesses (P=.001). For the 0.5-mm-thick specimens there were significant differences after the SB and L treatments. There was no significant difference between the HF and C treatments for any shades or thicknesses (P>.05). For the 1-mm-thick ceramics, there was only a significant difference between the L and C treatments for the HT shade ceramics (P=.01). There were also significant differences between the SB and C treatments except not for the HO shades (P=.768). CONCLUSION. The SB and L treatments caused laminate veneers to become more opaque; however, HF treatment did not affect the TP values. When the laminate veneers were thinner, both the shade of the ceramic and the SB and laser treatments had a greater effect on the TP values.

Fabrication and Device Characteristics of Infrared Photodetector Based on InAs/GaSb Strained-Layer Superlattice (InAs/GaSb 응력초격자를 이용한 적외선검출소자의 제작 및 특성 연구)

  • Kim, J.O.;Shin, H.W.;Choe, J.W.;Lee, S.J.;Kim, C.S.;Noh, S.K.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.108-115
    • /
    • 2009
  • The superlattice infrared photodetector (SLIP) with an active layer of 8/8-ML InAs/GaSb type-II strained-layer superlattice (SLS) of 150 periods was grown by MBE technique, and the proto-type discrete device was defined with an aperture of $200-{\mu}m$ diameter. The contrast profile of the transmission electron microscope (TEM) image and the satellite peak in the x-ray diffraction (XRD) rocking curve show that the SLS active layer keeps abrupt interfaces with a uniform thickness and a periodic strain. The wavelength and the bias-voltage dependences of responsivity (R) and detectivity ($D^*$) measured by a blackbody radiation source give that the cutoff wavelength is ${\sim}5{\mu}m$, and the maximum Rand $D^*$ ($\lambda=3.25{\mu}m$) are ${\sim}10^3mA/W$ (-0.6 V/13 K) and ${\sim}10^9cm.Hz^{1/2}/W$ (0 V/13 K), respectively. The activation energy of 275 meV analyzed from the temperature dependent responsivity is in good agreement with the energy difference between two SLS subblevels of conduction and valence bands (HH1-C) involving in the photoresponse process.

Effect of Ethanol Extracts of Goat's Beard on Streptozotocin Induced Diabetic Symptoms and Oxidative Stress in Rats (삼나물 에탄올 추출물이 Streptozotocin으로 유발한 흰쥐의 당뇨증상과 산화적 스트레스에 미치는 영향)

  • Shin, Jong-Wook;Lee, Sang-Il;Woo, Mi-Hee;Kim, Soon-Dong
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.18 no.6
    • /
    • pp.939-948
    • /
    • 2008
  • The effects of goat's beard (Aruncus dioicus var ramtschaticus Hara) ethanol extracts (AD) on the streptozotocin-induced diabetic symptoms and oxidative stress in rats were assessed. Experimental plots were divided into normal controls (NC), diabetes controls (DM), diet with 0.3% AD after diabetes induction (SA), and diet with 0.6% AD after diabetes induction (SB), then fed for 5 weeks. In the SA and SB groups as compared with the DM group, diabetic symptoms including weight loss, increase in feed and water intake, and enlargement of the liver and kidney were improved. The levels of blood glucose and serum fructosamine were reduced by $17.9{\sim}27.2%$ and $25.6{\sim}32.6%$, respectively. The activities of alanine aminotransferase, aspartate aminotransferase and the levels of triglycerides, total cholesterol, and LDL-cholesterol in the serum were reduced by $25.6{\sim}30.3$, $42.37{\sim}55.51$, $26.85{\sim}30.44$ and $37.29{\sim}39.11%$, respectively, whereas the level of HDL-cholesterol was increased by $37.29{\sim}39.11%$. Hepatic total (T) and O type (O) activities of xanthine oxidoreductase, O/T ratio(%) and level of lipid peroxide were significantly decreased, while the level of glutathione was increased, and also the activities of superoxide dismutase and glutathione S-transferase were increased by $56.84{\sim}94.90%$ and $57.14{\sim}68.92%$, respectively. In the above results, it was noted that AD has an antidiabetic effect which alleviated hyperglycemia and the AD reduced and/or prevented the tissue damage caused by diabetes yia the inhibition of reactive oxygen species (ROS) generating systems concurrent with an increase in ROS scavenging.

  • PDF

Electrical Characteristics of SMD Type Ceramic Resonators using PbTiO3 System as a Function of Electrode Radius Size (전극직경 크기에 따른 SMD형 PbTiO3계 세라믹 공진자의 전기적 특성)

  • 민석규;류주현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.8
    • /
    • pp.671-677
    • /
    • 2002
  • In this study, the high frequency SMD ceramic resonators with the size of $3.7{\times}3.1{\times}0.385\textrm{mm}^3$ were fabricated using $Pb_{0.88}(La_{0.6}Nd_{0.4})_{0.08}(Mn_{1/3}Sb_{2/3})_{0.02}Ti_{0.98}O_3$ ceramics with the variations of electrode radius size. With increasing the electrode radius size, resonant resistance in third overtone mode was decreased and electromechanical coupling factor($k_{t3}$) in third overtone mode was showed constant values. Taking into consideration mechanical quality factor($Qm_{t3}$) of 5,552 and dynamic range(D.R) of 60.72dB in third overtone mode, the ceramic resonator with the electrode radius size of $\theta$1.13mm was suitable for 20MHz resonator application.

Geochemical Study on Geological Groups of Stream Sediments in the Gwangju Area (광주지역 하상퇴적물에 대한 지질집단별 지구화학적 연구)

  • Kim, Jong-Kyun;Park, Yeung-Seog
    • Economic and Environmental Geology
    • /
    • v.38 no.4 s.173
    • /
    • pp.481-492
    • /
    • 2005
  • The purpose of this study is to determine geochemical characteristics for stream sediments in the Gwangju area. We collect the stream sediments samples by wet sieving along the primary channels and dry these samples slowly in the laboratory and grind to under 200mesh using an alumina mortar fur chemical analysis. Major elements, trace and rare earth elements are determined by XRF, ICP-AES and NAA analysis methods. For geochemical characteristics on geological groups of stream sediments, we separate geologic groups which are derived from Precambrian granite gneiss area, Jurassic granite area and Cretaceous Hwasun andesite area. Contents range of major elements for stream sediments in the Gwangju area are $SiO_2\;51.89\~70.63\;wt.\%,\;Al_2O-3\;12.91\~21.95\;wt.\%,\;Fe_2O_3\;3.22\~9.89\;wt.\%,\;K_2O\;1.85\~4.49\;wt.\%,\;MgO\;0.68\~2.90\;wt.\%,\;Na_2O\;0.48\~2.34\;wt.\%,\;CaO\;0.42\~6.72\;wt.\%,\;TiO_2\;0.53\~l.32\;wt.\%,\;P_2O_5\;0.06\~0.51\;wt.\%\;and\;MnO\;0.05\~0.69\;wt.\%.$ According to the AMF diagram for stream sediments and rocks, the stream sediments are plotted on boundary of tholeiitic series and calk alkaline series, which shows that contents of $Fe_2O_3$ are higher in stream sediments than rocks. According to variation diagram of $SiO_2$ versus $(K_2O+Na_2O),$ stream sediments are plotted on subalkaline series. Contents range of trace and rare earth elements for stream sediments in the Gwangiu area are Ba$590\~2170$ppm, Be1\~2.4$ppm, Cu$13\~79$ppm, Nb$20\~34$ppm, Ni$10\~50$ppm, Pb$17\~30$ppm, Sr$70\~1025$ ppm, V$42\~135$ppm, Zr$45\~171$ppm, Li$19\~77$ppm, Co$4.3\~19.3$ppm, Cr$28\~131$ppm, Cs$3.1\~17.6$ppm, Hf$5\~27.6$ppm, Rb$388\~202$ppm, Sb$0.2\~l.2$ ppm, Sc$6.4\~17$ppm, Zn$47\~389$ppm, Pa$8.8\~68.8$ppm, Ce$62\~272$ppm, Eu$1\~2.7$ppm and Yb$0.9\~6$ppm.

Flow sensor using stress-balanced membrane and thin film thermocouple (스트레스균형이 이루어진 멤버레인 및 박막 열전대를 응용한 유체센서)

  • Ahn, Yeong-Bae;Kim, Jin-Sup;Kim, Myung-Gyoo;Lee, Jong-Hyun;Lee, Jung-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.6
    • /
    • pp.51-59
    • /
    • 1996
  • A flow sensor has been fabricated by preparing thin film Pt-heater and Bi-Sb thermocouples array on 150 nm-$Si_{3}N_{4}$/300 nm-$SiO_{2}$/150 nm-$Si_{3}N_{4}$ dielectric diaphragm which has low thermal conductivity and balanced stress with silicon substrate for the purpose of improving the thermal isolation between heater and silicon substrate. Pt-heater showed nonlinear I-V characteristics due to the thermal isolation effect of the diaphragm. Its temperature coefficient of resistance was about $0.00378\;/^{\circ}C$ and Seebeck coefficient of Bi-Sb thermocouple was about $97\;{\mu}V/K$. The sensor showed that thermoelectric voltage decreased as thermal conductivity of gas increased, and flow sensitivity increased as heater voltage increased or as the distance between heater and thermocouple decreased. When heater voltage was about 2.5 V, $N_{2}$-flow sensitivity and thermal response time of the sensor were about $1.27\;mV{\cdot}(sccm)^{-1/2}$ and 0.13 sec., respectively.

  • PDF