• Title/Summary/Keyword: $SF_6/CO_2$

Search Result 99, Processing Time 0.027 seconds

Preparation and Characterization of Mixed-matrix Membranes Containing MIL-100(Fe) for Gas Separation (MIL-100(Fe)를 함유한 혼합기질막(mixed-matrix membranes, MMMs)의 제조 및 기체 투과 특성 연구)

  • Song, Hye Rim;Nam, Seung Eun;Hwang, Young Kyu;Chang, Jong San;Lee, U Hwang;Park, You In
    • Membrane Journal
    • /
    • v.23 no.6
    • /
    • pp.432-438
    • /
    • 2013
  • Mixed-matrix membranes (MMMs) containing MIL-100(Fe), a MOF type, were fabricated in this study. MMMs up to 30 wt% MOF loading were prepared, and their gas permeabilities were tested. $H_2$, $CO_2$, $O_2$, $N_2$, and $CH_4$ gas permeabilities increased with the MOF loading, while $SF_6$, the largest kinetic diameter in this study, exhibited reduction of gas permeability with the loading. Ideal gas selectivity of $N_2/SF_6$ improved by 40% as compared with pure polyimide membrane, suggesting the proposed MMMs were suitable for $N_2/SF_6$ separation.

Characteristics of sulfur hexafluoride hydrate film growth at the vapor/liquid interface (기상/액상 계면에서의 SF6 하이드레이트 필름 성장거동 연구)

  • Kim, Soo-Min;Lee, Hyun-Ju;Lee, Bo-Ram;Lee, Yoon-Seok;Lee, Eun-Kyung;Lee, Ju-Dong;Kim, Yang-Do
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.2
    • /
    • pp.85-92
    • /
    • 2010
  • $SF_6$ gas has been widely used in many industrial fields as insulating, cleaning and covering gases due to its outstanding arc-extinguishing and insulating properties. However, global warming potential of $SF_6$ gas is 23,900 times more than that of $CO_2$ and it remains in the air during 3,200 years. For these reason, technological and economical effects could be expected for the separation of $SF_6$ from gas mixtures by hydrate forming process. In this study, we carried out morphological studies for the $SF_6$ hydrate crystal to understand its formation and growth mechanisms. $SF_6$ hydrate film was initially formed at the interfacial boundary between gas and liquid regions, and then subsequent dendrite crystals growth was observed. The dendrite crystals grew to the direction of gas region probably due to the guest gas concentration gradient. The detailed growth characteristics of $SF_6$ hydrate crystals such as nucleation, migration, growth and interference were discussed in this study.

Fundamental Study on the Maintenance Technology for SF6 Gas Condition using Pressure and UHF Sensors (UHF 및 가스센서를 이용한 SF6 가스 상태 감시기술 기초연구)

  • Ahn, Hee-Sung;Cho, Sung-Chul;Eom, Ju-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.20-27
    • /
    • 2007
  • [ $SF_6$ ] gas for compacted power facilities has a important role as an insulation gas. It is very blown well that $SF_6$ gas has the superior characteristics as an insulation gas. For reliable operation of SF6-gas-based high and medium voltage equipment it is very important to keep the insulation ability within a safe range. And the experimental and measuring system were implemented. The test chamber designed to endure up to 3 atmospheric pressure. The analysis results of the experimental data shows that positive partial discharge can be detected by discharge current and UHF signal. Additionally it is shown the possibility that $CO_2$ gas sensor of semiconductor type can be detect the variation of $SF_6$ gas condition. The UHF sensor shows good feature to detect the variation of $SF_6$ gas condition for partial discharge and breakdown discharge.

Investigation of the Supercritical Fluids as an Insulating Medium for High Speed Switching

  • Shon, Chae-Hwa;Song, Ki-Dong;Oh, Yeon-Ho;Oh, Ho-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1783-1786
    • /
    • 2016
  • The paper investigates the insulation properties of the supercritical $CO_2$ ($SCCO_2$) fluid as an insulating medium for electrical apparatuses. The insulating material is crucial for electrical apparatuses and $SF_6$ gas has been widely used for high power electrical apparatuses. There have been many research efforts to develop substituents for $SF_6$ gas because of high global warming potential. We obtained above 350 kV/mm insulation strength with 12.0 MPa $SCCO_2$. The positive and negative IEC standard pulses are applied between two 10 mm diameter spherical electrodes. The insulation strength of $SCCO_2$ is at least 2.5 times higher than that of $CO_2$ gas at 6.0MPa. The insulation strength of $SCCO_2$ fluid is about 10 times higher than that of $SF_6$ at 0.5MPa which is the ordinary operating pressure of electrical switchgears. Using the result, we expect that the time for switching and dielectric recovery could be reduced using $SCCO_2$ fluid as an insulating medium.

Effects of Surfactant on SF6 Gas Hydrate Formation Rate (가스 하이드레이트 형성 원리를 이용한 SF6 처리 기술에 관한 연구)

  • Lee, Bo-Ram;Lee, Hyun-Ju;Kim, Shin-Ho;Lee, Ju-Dong;Kim, Yang-Do
    • Korean Journal of Materials Research
    • /
    • v.18 no.2
    • /
    • pp.73-76
    • /
    • 2008
  • [ $SF_6$ ] gas has been widely used as an insulating, cleaning and covering gas due to its outstanding insulating feature and because of its inert properties. However, the global warming potential of $SF_6$ gas is extremely high relative to typical global warming gases such as $CO_2$, CFCs, and $CH_4$. For these reasons, it is necessary to separate and collect waste $SF_6$ gas. In this study, the effects of a surfactant (Tween) on the formation rate of $SF_6$ gas hydrates were investigated. The $SF_6$ gas hydrate formation rate increased with the addition of Tween and showed a nearly 6.5 times faster hydrate formation rate with an addition of 0.2 wt.% Tween compared to an addition of pure water. This is believed to be due to the increased solubility of $SF_6$ gas with the addition of the surfactant. It was also found that $SF_6$ gas hydrate in the surfactant solution showed two-stage hydrate formation rates with a formation rate that increased rapidly in the 2nd stage.

Discharge Characteristics of SF6 Mixture Gases due to Processing Status of needle electrode under Non-Uniform Fields (불평등 전계 하에서의 침전극 가공상태에 따른 SF6혼합가스의 방전특성)

  • Go, Y.S.;Seo, H.J.;Rhie, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.198-199
    • /
    • 2006
  • AC spark discharge voltage of SF6/C02and SF6/N2 containing various mixed rate in volume percent (1, 5 and 10%) of SF6 in non-uniform fields are investigated. The needle to plane electrode gap spacing was 5 and 10 mm, and the gas pressure was varied within the range of 0.1${\sim}$0.7 MPa. We have observed a N-characteristic typical for the electronegative gases even in gas mixtures of 1% SF6 with CO2 and N2 as buffer gases. Especially, the materials of the needle electrode affect the insulation properties of the gas mixtures drastically. On the contrary to the case of needle electrodes made by mild steel or high carbon steel, the N-characteristics are hardly perceived in the case of stainless steel needle in this experiment.

  • PDF

A Study on Spectroscopic Analysis by using Raman Spectrometer of Multi-Guest Mixed Hydrates Containing $SF_6$ (Raman Spectroscopy를 이용한 $SF_6$ 혼합 하이드레이트의 분광학적 해석에 관한 연구)

  • Shin, H.J.;Moon, D.H.;Kim, M.C.;Kim, Y.S.;Seo, Y.W.;Lee, G.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.223-225
    • /
    • 2008
  • 하이드레이트는 저온.고압에서 저분자량의 게스트(guest)가 호스트(host)인 물분자 속에 포획되어 만들어지는데 일련의 과정은 물리적 반응을 통해 생성된다.본 연구에서는$CO_2$보다 지구온난화지수(Global Warming Potential)가 23,900배 높은 $SF_6$의 회수 및 정제기술로써 하이드레이트화를 이용하는 신기술 개발의 일환으로 분광학적 접근을 통해 $SF_6$ 혼합 하이드레이트의 정성 및 정량분석을 수행하였다. Raman Shift 분석 결과 $SF_6$$770cm^{-1}$에서 $v_1$ 진동주파수를 확인함으로써 하이드레이트 내 $SF_6$가 안정적으로 포집됨을 확인하였고 혼합가스 내 $SF_6$ 농도별로 만들어진 샘플의 Raman Shift를 통해서 $SF_6$의 하이드레이트 전환율을 가늠할 수 있었다.

  • PDF

Permeation and Permselectivity variation of $O_2$, $CF_4$ and $SF_6$ through Polymeric Hollow Fiber Membranes (고분자 분리막 재질 변화에 따른 $O_2$, $CF_4$, $SF_6$ 투과도 및 투과선택도 특성 변화에 대한 연구)

  • Lee, Hyun-Jung;Lee, Min-Woo;Lee, Hyun-Kyung;Lee, Sang-Hyup
    • Membrane Journal
    • /
    • v.20 no.3
    • /
    • pp.249-258
    • /
    • 2010
  • In this study, we tried to observe the permeation on the single $O_2$, $CF_4$ and $SF_6$ gas using a PSF (polysulfone), PC (tetra-bromo polycarbonate) and PI (polyimide) hollow fiber membranes. We also observed the permselectivity on the $O_2/SF_6$ and $CF_4/SF_6$. According to the results of single gases permeation for different pressures, PSF membrane has the highest $O_2$ permeation of 37.5 GPU and PC membrane has the highest $SF_6$ permeation of 2.7 GPU and the highest $CF_4$ permeation of 2.5 GPU at 1.1 MPa. According to the results of single gases permeation for different temperatures, PSF membrane has the highest permeation of $O_2$ at $45^{\circ}C$ and PC membrane has the highest permeation of $SF_6$ and $CF_4$ at $25^{\circ}C$. From the result of $O_2/SF_6$ and $CF_4/SF_6$ permselectivity for different pressures and temperature, the highest permeation and the lowest permselectivity were observed in the PSF and PC membrane. On the contrary, the lowest permeation and the highest permselectivity was observed in the PI membrane.

A Study on the Improvement Repeatability and Accuracy of the Analysis Method for SF6 of Trace Level (극미량 수준의 SF6 측정법에 따른 재현성 및 정확도 향상에 관한 연구)

  • Yoo, Heejung;Choe, Hongwoo;Lee, Sepyo;Kim, Jongho;Han, Sangok;Ryoo, Sangboom
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.523-530
    • /
    • 2018
  • Kyoto Protocol, adopted in 1997, set the obligation to reduce $CO_2$, $CH_4$, $N_2O$, HFCs, PFCs, and $SF_6$ in developed countries during 1st promised period. $SF_6$ has been drawing a lot of attention since the Kyoto Protocol because once it is released into the atmosphere, it not only stays in the atmosphere for more than 3,200 years but also emits 22,800 times stronger global warming potential at the same concentrations as $CO_2$ if remains in the atmosphere for 100 years. This study introduces 12 methods for $SF_6$ of measuring trace. $SF_6$ of trace level in the atmosphere correctly, the measurement method was changed and as a result, when the back flush method was applied to the pre-concentration system that used low-temperature concentration and high-temperature desorption system, which used Carboxen-1000 adsorption trap, the effect was the best.

$SF_6$ Emission Characteristics at High Voltage Equipments in use-phase Stage (고압 전력기기에서의 $SF_6$ Gas 사용단계별 배출특성에 관한 연구)

  • Park, Jung-Ju;Cha, Yeun-Haeng
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2199-2201
    • /
    • 2008
  • Sulfur hexafluoride($SF_6$) is a gaseous dielectric used in high voltage electrical equipment such as an insultor or arc quenching medium in the transmission and distribution of electricity. however, $SF_6$ is one of the greenhouse gases(GHG) with a global warming potential that is 23,900 times greater than that of carbon dioxide($CO_2$). for this reason, $SF_6$ emissions in electric equipment shall be controlled to reduce GHG and improve cost-effective use of $SF_6$ for economical benefits. Until recently there has not been any investigation on $SF_6$ emission characteristics and inventory in Korea. To understand emission characteristics during the use-phase, the scope of this study was limited to the following closed pressure system equipment from 10 substations in Korea. This study highlights (1) the investigation of sampling/analysis methodology for $SF_6$ emissions in high voltage equipment, (2) the estimation of $SF_6$ emissions in the use-phase, and (3) the comparison between the emission ratio and the mass-balance applied to inventory study. According to this study, the majority of emissions were related to electric equipment nameplates and the rest of the emissions were related to the handling of $SF_6$ during operations. from this result, emission ratios estimated from this study were similar; GIS was 14% and GCB was 13%, as maintenance process conditions were the same as manual process conditions for both equipment.