• 제목/요약/키워드: $SF_6$가스

검색결과 347건 처리시간 0.032초

$SF_{6}$ 가스의 온도변화에 따른 절연특성 (The Characteristics of Insulation with Temperature Variations of $SF_{6}$)

  • 이광식;박광서;박경태;김이국;박창기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권8호
    • /
    • pp.354-358
    • /
    • 2003
  • In this paper, insulations characteristics by temperature changes(+50~-50[$^{\circ}C$]) of $SF_{6}$ gas in the experimental chamber were studied. From this result, at the low temperature, the breakdown voltage was increased with a drop of temperature and an increase of inner pressure in GIS. In addition the ability of insulation of liquid $SF_{6}$ was higher than that of the highly pressurized $SF_{6}$ gas. That is, with progress of low temperature, the main reason of breakdown was not liquefaction of $SF_{6}$ but rapid decrease of inner pressure. This study will come in greatly handy for the insulation design of GIS in a hard cold region

$ SF_6$가스의 전자에너지 분포함수에 관한 연구 (A Study on the electron energy diffusion function of the sulphur hexaflouride)

  • 김상남;하성철
    • 조명전기설비학회논문지
    • /
    • 제13권2호
    • /
    • pp.95-101
    • /
    • 1999
  • $ SF_6$ 가스의 전자에너지 분포함수를 평균에너지 평형 영역에 대하여 E/N=500~800[Td]에서 해석하였다. 본 논문은 저자들에 의해 결정된 충돌 단면적을 사용하여 몬테칼로 시뮬레이션과 볼쯔만 방정식에 의해 E/N=150~800[Td]범위에서 계산된 $ SF_6$ 가스의 전자 수송 특성과 TOF법에서 구한 전자군 파라미터 값들을 나타냈다. 전자이동속도 전자 이온화 또는 부착계수, 종.횡 방향 확산계수 등의 전자군 파라미터 값들은 E/N 범위에서 실험 치와 이론 치가 일치하였다. 전자사태의 특성은 전자에너지의 비평형 영역에서 고려되었다.

  • PDF

$SF_6$ 가스 동축원통전극 내의 금속이물이 절연파괴에 미치는 영향 (The Effect on Breakdown of the Conducting Particles Between Coaxial Cylindrical Electrodes in $SF_6$ Gas)

  • 조국희;권동진;이강수;곽희로
    • 조명전기설비학회논문지
    • /
    • 제12권2호
    • /
    • pp.85-90
    • /
    • 1998
  • 본 논문에서는 AC 전압 하에서 자유 도전성 금속이물 혼입에 의한 SF6 가스로 압축된 GIS의 절연특성에 관하여 연구하였다. GIS 내에서 자유 도전성 금속이물이 혼입되면 절연파괴 전압을 낮추는 결정적인 역할을 할 수 있으므로, 금속이물의 재질과 크기에 따른 부상전계 및 절연파괴전압을 측정하였다. 구리, 철, 알루미늄의 선형 금속이물에서의 부상전계 계산값과 측정값을 비교, 분석하였다. 압축된 $SF_6$ 가스로 절연된 동축원통전극간에 금속이물의 혼입될 경우의 절연파괴전압은 금속이물의 없을 때보다 낮게 나타났으며, 금속이물의 재질과 크기에 상당히 의존하였다. 따라서 자유도전성 금속이물은 GIS의 절연파괴 특성에 매우 중요한 요소로 작용함을 알 수 있었다.

  • PDF

$SF_6$ 가스챔버내 금속이물에 대한 부분방전 및 절연파괴 현상 (The partial discharge and breakdown phenomena due to metallic particle in $SF_6$ gas chamber)

  • 이재걸;곽희로;조국희;박중신
    • 조명전기설비학회논문지
    • /
    • 제14권1호
    • /
    • pp.75-81
    • /
    • 2000
  • 본 논문에서는 $SF_6$가스 내에 혼입된 급속이물에 의한 부분방전에 대해 연구하였다. 모의 GIS챔버를 설계.제작하여, 전극 내에 혼입된 금속이물에 의한 부분방전 및 절연파괴과정을 관측하고, 초음파센서를 이용하여 부분방 전올 검출하였다. 또한 전극 내에 혼입된 금속이물의 위치에 따른 전계를 해석하였다. $SF_6$가스 내에서 금속이물의 거동 중 끝단에서 부분방전이 발생하였다 이와 같이 금속이물이 거동중에 발생하는 미소 캡사이의 방전은 아크방전으로 진전되어, 결과적으로는 절연파괴를 유발할 수 있다. 금속이물의 위치에 따른 전계분포는 금속이물이 상부전극에 수직으로 부착되어 있는 경우에 전계의 세기가 가장 크고, 하부전극에 수평으로 부착되어 있는 경우가 가장 낮게 나타났다.

  • PDF

혼합가스의 이물 존재시 절연 특성 연구 (A study of dielectric strength and insulating property for particle contamination Under SF6/N2 Mixture)

  • 정동훈;우수열;서경보;김진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1262-1263
    • /
    • 2011
  • Sulfur hexafluoride is the most commly used insulation gas in electrical systems. Gas insulated systems are widely used in the electric power industry for transmission and distribution of electrical energy. When $SF_6$ was first discovered, the potential application was only considered for insulation because of good dielectric properties. But the widespread use of $SF_6$ gas by electric power and other industries has led to increase concentrations of $SF_6$ gas in the atmosphere. This concern as to possible effects on global warming because $SF_6$ is a potent greenhouse gas. That's why firstly we studied uniform and nonuniform field property by mixing $SF_6$ and N2 gas. This paper presents the dielectric strength and insulating property for particle contamination under $SF_6/N_2$ mixtures. Two types of mixed gases(50% $SF_6$_50%$N_2$, 20% $SF_6$_80%$N_2$) were applied. We performed tests for the length and shape of particle. Test gas pressure is from 0.3 to 0.7 Mpa. The study was conducted to develop environment-friendly insulating material for GIS that can reduce $SF_6$ gas and make a design criteria for mixtures.

  • PDF

$SF_6$ 대체가스 연구동향 (Trends on the Research for Alternatives of $SF_6$ Gas)

  • 이동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1403-1406
    • /
    • 2002
  • Environmental impact of human activities has become a great concern in most of the countries world-wide, and for years. It has recently focused on potential climate changes due to the increase of green house gases content in the atmosphere. One of these gases is $SF_6$, which is an essential material in electrical applications having excellent dielectric and arc-quenching properties. Though the actual contribution of $SF_6$ to global warming is negligible at present, the control of $SF_6$ emissions seems to be nevertheless imperative. Actually, it is listed in the Kyoto protocol that emissions should not only be duly reported but also the electrical industry which is now the major user of this gas must be able to show that it is possible to use this gas and at the same time preserve the environment. For the development of environmentally-benign electric power equipment and systems, novel gases or gas mixtures are strongly required as the alternatives of $SF_6$ gas. Until now, most research work is focused on the $SF_6/N_2$ mixed gas which is suitable for application in the electrical apparatus with slightly non-uniform fields. Recently, $SF_6/CO_2$ mixed gas also is expected to be promising as a $SF_6$ alternative, especially in highly non-uniform fields and in a gas-impregnated film insulation system. Including these results, the author reviews the research trend or reducing the environmental impact of $SF_6$ gas in this paper.

  • PDF

불평등 전계에서 $SF_6/CF_4$ 혼합가스의 절연내력과 PD특성 (Breakdown Voltage and PD Characteristics of $SF_6/CF_4$ Mixtures in Nonuniform Field)

  • 황청호;성허경;허창수
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.635-640
    • /
    • 2008
  • New gas mixtures are now finding applications such as interrupting media for high-voltage circuit breakers. These mixtures consist of a high content of carbon tetrafluoride($CF_4$) added to sulfur hexafluoride($SF_6$). Nowdays $SF_6$ has been established for the use in gas insulated substations due to its high insulation withstand level and good arc quenching capability. At this paper Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltage and standard lightning impulse voltage(LI) was applied in a needle-plane electrodes. And partial discharge(PD) experiments were carried out in the test chamber which was made in needle-plane electrode. And ${\Phi}$-Q-N distribution of partial discharge signals was analyzed. The total pressure of the $SF_6/CF_4$ mixtures was varied within the range of 0.1-0.5 Mpa in the test chamber. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at positive impulse voltage and the PD inception voltage was increased slightly when pressure of $SF_6/CF_4$ Mixtures was increased. Maximum PD inception voltage is showed in 80% SF6/20%$CF_4$.

극저온 정제시스템의 품질관리를 위한 SF6 가스 분석방법 개선 (Improved sulfur hexafluoride(SF6) gas analysis method for quality management of cryogenic refinement system)

  • 이정은;조민;이원석
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.37-41
    • /
    • 2022
  • Because sulfur hexafluoride(SF6) is classified as one of the six major greenhouse gases, SF6 handling in power plant such as recovery, purification, and reuse is considered to be important. KEPCO has focused to develop the advanced recovery and purification technology of SF6 reuse. SF6 analysis includes the on-site analyses and on-line analyzer; i.e., (1) on-site analysis has an error rate of ±0.5% and (2) on-line analysis has an error rate of ±0.1%, which is possible to adjust operating conditions and to make the work more conveniently by analyzing SF6 concentration before and after purification step. This paper presents an online analysis method in the SF6 purification and reuse system. In addition, the analysis results and quality guarantees for each section of the analysis system were presented.

가스차단기 최적설계를 위한 $SF_6$ 아크 플라즈마 CAE 해석 (CAE Analysis of $SF_6$ Arc Plasma for a Gas Circuit Breaker Design)

  • 이종철;안희섭;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.365-368
    • /
    • 2002
  • The design of industrial arc plasma systems is still largely based on trial and error although the situation is rapidly improving because of the available computational power at a cost which is still fast coming down. The desire to predict the behavior of arc plasma system, thus reducing the development cost, has been the motivation of arc research. To interrupt fault current, the most enormous duty of a circuit breaker, is achieved by separating two contacts in a interruption medium, $SF_{6}$ gas or air etc., and arc plasma is inevitably established between the contacts. The arc must be controlled and interrupted at an appropriate current zero. In order to analyze arc behavior in $SF_{6}$ gas circuit breakers, a numerical calculation method combined with flow field and electromagnetic field has been developed. The method has been applied to model arc generated in the Aachen nozzle and compared the results with the experimental results. Next, we have simulated the unsteady flow characteristics to be induced by arcing of AC cycle, and conformed that the method can predict arc behavior in account of thermal transport to $SF_{6}$ gas around the arc, such as increase of arc voltage near current zero and dependency of arc radius on arc current to maintain constant arc current density.

  • PDF

PFCs가스 분해처리를 위한 글라이딩 아크 플라즈마 응용 (Gliding arc plasma application for PFCs gas decomposition)

  • 노임준;신백균;박동화;김형권;이상희;박종국;강대하;김진식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1354-1355
    • /
    • 2008
  • 교류 펄스전압을 이용한 글라이딩 아크 플라즈마를 이용하여 PFCs(Perfluoro compounds) 가스의 일종인 $CF_4$ $SF_6$, $NF_3$를 가스분해하는 연구를 실시하였다. 반응기 양전극 사이에 인가되는 전압은 10kV로 고정하고 각각의 가스의 유량을 조절하여 분해한후 FT-IR을 통해 각각의 가스의 분해율과 분해후 가스내 성분을 스펙트럼을 이용하여 분석하였다. 유량이 낮아질수록 분해율은 좋아졌고 $SF_6$$NF_3$의 경우 99%이상의 높은 분해율에 도달하였을 뿐 아니라 대표적인 난분해 가스로 손꼽히는 $CF_4$의 경우 82%이상의 분해율을 확인하였다.

  • PDF