• Title/Summary/Keyword: $PM_{1}$

Search Result 25,214, Processing Time 0.045 seconds

Bionomical Characteristics of Luciola lateralis (Coleoptera: Lampyridae) in Mass Breeding (애반딧불이(딱정벌레목: 반딧불이과)의 생육 특성)

  • Kim, Ha-Gon;Kwon, Yong-Jung;Suh, Sang-Jae
    • Journal of Life Science
    • /
    • v.18 no.12
    • /
    • pp.1728-1732
    • /
    • 2008
  • This study was performed to investigate the bionomical characteristics of Luciola lateralis in Korea. Imago's longevity of female was $17.5{\pm}0.7$ and male was $20.6{\pm}1.0$ days at $23^{\circ}C$, R.H. 80%, and significant difference was not occurred in breeding density. Pre-oviposition period was a pair $2.8{\pm}1.5$, two pairs $2.5{\pm}1.5$, three pairs $1.7{\pm}0.7$, four pairs $1.3{\pm}0.5$ days and pre-oviposition period was shorten in higher breeding density. The mean of laying eggs was $248.9{\pm}80.7$, was not related breeding density. Daily oviposition rate was 1st day 20.8%, 2nd 17.3%, 3rd 14.3%, 4th 12.7%, 5th 7.0%, the rate was highest in 1st day and gradually reduced. Egg period was $21.8{\pm}0.7$ days and hatchability was $95.5{\pm}4.8%$. Larval instar was identified the 9th instar, the evidence was able to its skin and marking pattern. Larval period of each instar was 1st $1.0{\pm}0.1$, 2nd $3.3{\pm}0.2$, 3rd $10.2{\pm}1.0$, 4th $6.8{\pm}0.5$, 5th $6.9{\pm}2.0$, 6th $15.4{\pm}4.1$, 7th $18.3{\pm}5.9$, 8th $25.8{\pm}8.7$, 9th $31.2{\pm}13.2$ days. Matured 9th larva was made of cocoon during $2.8{\pm}0.8$ days and pre-pupal, pupal period was $4.6{\pm}0.9$, $5.6{\pm}0.7$ days. Imago was made hard hind wing during $3.8{\pm}0.4$ days in cocoon and come out.

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

Study on the Radial Variation of Structural Element in the Diffuse-Porous Woods (주요산공재(主要散孔材) 구성요소(構成要素)의 방사방향(放射方向) 변동(變動)에 관한 연구(硏究))

  • Han, Cheol-Soo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.26-52
    • /
    • 1987
  • Among the diffuse-porous woods which arc dominant in Korea and used as construction materials due to their wood quality, ten species of six genus involving seven species of three genus in Betulaceae were studied on the radial variation of structural demenb. The species studied were Betula platyphylla var. japonica, B. ermanii, B. davurica, B. scstata, B. schmidtii, Carpinus laxifora, Alnus japonica, Prunus sargentii. Acer mono and Diospyros kaki. Wood fiber, vessel elements and ray increased rapidly in size from pith to a certain annual ring. After then the radial variation in size of the main structural elements seemed to be divided into three types; levelled off curve pattern indicating constant size(type I), continuously increasing curve pattern showing ever increase in size (type II) and parabolic curve pattern showing the gradual decrease after the maximum (type III), but the variation types by structural dements were different even in the same species. Based on the results from this study, it appears to be reasonable to consider the stabilized age of wood fiber, vessel elements and ray rather than considering wood fiber length in distinguishing mature woods from juvenile woods.

  • PDF

The Bone Mineral Density Value According to the Operating Time of the Dual Energy X-ray (이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가)

  • Lee, Hae-Jung;Kim, Ho-Sung;Kim, Eun-Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.40-45
    • /
    • 2010
  • Purpose: Recently, the performance of the X-ray tube was very much improved by the power generation of the technology. However, the overload of equipment is occurred by the increment of the equipment operating time according to the increment of the examination number of cases. The X-ray dose can change by heat occurrence of the X-ray tube due to this. Moreover, the change of the bone mineral density value is possible to occur. Therefore, We tries to whether the change of the bone mineral density value of each equipment according to the difference of the examination number of cases and operating time occur or not. Materials and Methods: The BMD value was measured by the Aluminum Spine Phantom and the European Spine Phantom in each equipment, in order to find out about the difference of the time general classification bone mineral density value by using the Dual energy X-ray absorptiometry. And after scanning each phantom by using X-ray dose meter (Unfors Mult-O-Meter), a dose was measured by the same condition. As to, an average and standard deviation were found and the change of each equipment much BMD value was compared and it evaluated. Results: $Mean{\pm}SD$ of each equipment by using the Aluminum Spine Phantom, A equipment was $1.174{\pm}0.002$, $1.171{\pm}0.005$, $1.173{\pm}0.005$, B equipment was $1.186{\pm}0.003$, $1.187{\pm}0.003$, $1.185{\pm}0.003$, C equipment was $1.180{\pm}0.003$, $1.182{\pm}0.004$, $1.183{\pm}0.002$, D equipment was $1.188{\pm}0.004$, $1.185{\pm}0.003$, $1.185{\pm}0.004$. By using the European Spine Phantom, A equipment was $1.143{\pm}0.006$, $1.153{\pm}0.009$, $1.161{\pm}0.003$, B equipment was $1.134{\pm}0.004$, $1.13{\pm}0.008$, $1.127{\pm}0.015$, C equipment was $1.143{\pm}0.006$, $1.134{\pm}0.01$, $1.133{\pm}0.006$, D equipment was $1.14{\pm}0.001$, $1.122{\pm}0.002$, $1.131{\pm}0.008$, altogether included in the normal range. Conclusion: There was no significant change of the BMD value of using a phantom by time zones. Therefore, if the quality control is made to use the extent management method of the equipment for beginning in the present application, the reliability of the BMD equipment will be able to be enhanced.

  • PDF

A study on hematological different values between the two rural regions in Korea (part one) (우리나라 일부지역의 혈야상에 관한 고찰(제 1보))

  • 윤기은;문히주
    • Journal of Environmental Health Sciences
    • /
    • v.3 no.1
    • /
    • pp.4-8
    • /
    • 1976
  • Authors investigated the hematological examinations of 993 persons at rural region among the 1,7 41 of residents in-the part of Dang Jin (M:268, F:247) and Young Joo (M:270, F:208) in the Korea which was indicated as follows. 1. Average value and standard deviation of hematological items represents as follows: i) Hemoglobin Men Dang Jin-13.99$\pm$0.52. Man Young Joo-14.93$\pm$0.57 Women Dang Jin-12.56$\pm$0.38 women Young Joo-13.65$\pm$0.48 ii)Hematocrit Men Dang Jin-42.68$\pm$1.09 Man Young Joo-44.61$\pm$1.42 Women Dang Jin-38.16$\pm$0.93 women Young Joo-40.33$\pm$1.27 iii) Mean Corpuscular hemoglobin concentration Men Dang Jin-32.79$\pm$1.06. Man Young Joo-33.46$\pm$0.36 Women Dang Jin-32.92$\pm$0.75 women Young Joo-33.83$\pm$0.82 iv) WBC Men Dang Jin-7.130$\pm$880. Man Young Joo-7.490$\pm$910 Women Dang Jin-6.030$\pm$1.150 women Young Joo-7.320$\pm$1.040 2. The aspect of blood type at Young Joo and Dang Jin was same indicated in the order of A,O,B, and AB. 3. There are higher values of hemoglobin, hernatocrit, M.C.H.C. and WBC in men and women at Young Joo than Dang Jin.

  • PDF

Standardization of Manufacturing Method of Young Radish Kimchi (Yulmoo Kimchi) and Young Radish Watery Kimchi (Yulmoo Mool-Kimchi) in Literatures (문헌에 나타난 열무김치 및 열무물김치 제조 방법의 표준화)

  • Kong, Chang-Suk;Kim, Do-Kyoung;Rhee, Sook-Hee;Rho, Chi-Woong;Hwang, Hae-Jun;Choi, Keyng-Lag;Park, Kun-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.1
    • /
    • pp.126-130
    • /
    • 2005
  • Manufacturing method and ingredient ratio for young radish kimchi (yulmoo kimchi) and young radish watery kimchi (yulmoo mool-kimchi) were standardized from literatures. Ingredients having frequency of use greater than 50% were only used in the standardization process. Green onion, red pepper, red pepper powder, garlic, ginger, and anchovy juice were included in young radish kimchi. Green pepper, red pepper, garlic, ginger, and starch were included in young radish watery kimchi. The standardized ingredients ratio of young radish kimchi (yulmoo kimchi) on young radish 100 g was as follows: green onion 8.0$\pm$3.8, crushed garlic 2.9$\pm$1.3, crushed ginger 1.6$\pm$0.7, red pepper 7.0$\pm$1.7, red pepper powder 4.2$\pm$1.2, and anchovy juice 3.7$\pm$0.5. The standardized ingredients ratio of young radish watery kimchi (yulmoo mool-kimchi) on added water 100 mL was as follows: young radish 50.6:$\pm$10.8, crushed garlic 3.0$\pm$0.7, crushed ginger $1.5\pm$0, green onion 3.3$\pm$1.3, green pepper 3.3$\pm$1.9, red pepper 2.4$\pm$1.3, and starch $1.5\pm$0.6.

A Study on Energy Expenditure in Korean Children (한국 아동의 에너지 소비량에 관한 연구)

  • 오승호
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.22 no.5
    • /
    • pp.531-538
    • /
    • 1993
  • A 4-week energy balance study was conducted to estimate the energy expenditure (EE) of 16 primary school age boys and girls, 8 to 12 year age, by measurement of energy intakes and changes in body energy (BE) content (intake / balance technique), keeping their normal living pattern and eating behavior. Gross energy intake (GE) and fecal energy (FE) loss was measured by bomb calorimetry. Urinary energy (UE) loss was calculated from nitrogen excreted. Fat mass (FM) was determined from body density estimated from skinfold thickness. Mean constitutional ratio of carbohydrate, protein and fat for the total energy intake was 10.1 $\pm$1.8%, 12.2$\pm$0.1% and 17.1$\pm$2.0% for the boys and 74.0$\pm$1.7%, 10.7$\pm$0.3% and 15.3$\pm$0.5% for the girls, respectively. Fecal energy loss was 5.1% and 4.5% proportion of the gross energy intake for the boys and girls, respectively. Mean daily metabolizable energy estimated by subtract feral and urinary energy loss was 1862$\pm$15kcal for the boys and 1627$\pm$20kcal for the girls. Total body energy change estimated from body composition change over 28 days was increased 1524$\pm$539kcal for the boys and 3622$\pm$718kcal for the girls. Mean daily energy expenditure was 1812$\pm$37kcal(52 $\pm$2kcal/kg of body weight) for the boys and 1487$\pm$25kca1 (52$\pm$2kcal/kg of body weight) for the girls.

  • PDF

Studies of Thyroid Function Test Using Radioiodine by Intradermal Injection (방사성(放射性) 옥소(沃素) 피내(皮內) 주사(注射)에 의(依)한 갑상선(甲狀腺) 기능검사(機能檢査)에 관(關)한 연구(硏究))

  • Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.6 no.1
    • /
    • pp.41-49
    • /
    • 1972
  • The author observed the thyroid $^{131}I$ uptake rate using an intradermal injection method. The amount of activity remaining at the site of intradermal injection of 0.1 ml. of $5{\mu}Ci.\;of\;^{131}I$ in physiologic saline was measured in 79 cases of hyperthyroidism and in 24 cases of hypothyroidism. The cases had been confirmed by clinical and laboratory findings, at the department of medicine, (radioisotope clinic) Pusan National University Hospital. Twenty-nine normal control cases were examined currently by the same technique during the period from Jan. 1967 to June 1970. The following results were obtained: 1. In the normal group, the ranges and mean values of the thyroid uptake 10, 15, 20, 25, 30 and 60 minutes after intradermal $^{131}I$ injection, were $0{\sim}10%(6.33{\pm}1.63),\;0{\sim}15%(7.83{\pm}2.12),\;0{\sim}15%(8.46{\pm}2.82),\;5.1{\sim}20%(9.66{\pm}2.27),\;5.1{\sim}25%(10.47{\pm}2.52),\;5.1{\sim}30%(13.03{\pm}4.42)$. 2. In the hyperthyroid group, the ranges and mean values of the thyroid uptake 10, 15, 20, 25, 30 and 60 minutes after intradermal $^{131}I$ injection were $5.1{\sim}45%(22.25{\pm}7.04),\;10.1{\sim}50%(28.32{\pm}6.67),\;15.1{\sim}55%(34.78{\pm}11.63),\;15.1{\sim}65%(37.95{\pm}7.72),\;20.1{\sim}65%(41.49{\pm}0.05)\;and\;20.18096(48.71{\pm}12.51)$. 3. In the hypothyroid group, he ranges of thyroid $^{131}I$ uptake by intradermal $^{131}I$ injection at 10, 15, 20, 25, 30 and 60 minutes lay between 0 and 10%, and the the mean values were $4.23{\pm}1.76,\;5.08{\pm}1.68,\;5.56{\pm}1.70,\;6.02{\pm}1.75,\;6.37{\pm}1.91\;and\;6.95{\pm}2.07$. 4. In conclusion, thyroid function test using an intradermal injection method in cases of hyperthyroidism, showed characteristic values which seemed to be of diagnostic significance.

  • PDF

Effect of head positioning on the vertical and horizontal magnification in panoramic radiographs: rotation along the sagittal and transverse plane (파노라마방사선사진에서 환자의 머리 위치가 하악 수직, 수평 확대율에 미치는 영향: 상하 및 좌우회전)

  • Kim, Yong-Gun;Byun, Jin-Seok;An, Seo-Young
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the effect of head position changes on vertical and horizontal magnification in dental panoramic radiographs. Materials and Methods: Five 4 mm metal balls were placed above alveolar crest of dry skull considering extraction socket and dental arch. Panoramic radiographs were taken by OP-100D (Instrumentarium Imaging Co., Tuusula, Finland) at proper and rotated head position along the sagittal and transverse axis at 3 - $20^{\circ}$ upwardly, downwardly, to the left and to the right rotation. Images were stored in DICOM files and were measured by ruler equipped within INFINITT PACS software. Results: The mean horizontal magnification was $1.22{\pm}0.01-1.44{\pm}0.01$ and mean vertical magnification was $1.29{\pm}0.00-1.35{\pm}0.02$ at standard head position. There was statistical significance of horizontal magnification between the anterior ($1.24{\pm}0.02-1.31{\pm}0.03$) and the posterior area ($1.40{\pm}0.03-1.33{\pm}0.02$) (P < 0.05). Vertical magnification resulted in less variation ($1.24{\pm}0.01-1.37{\pm}0.02$) than horizontal magnification ($0.88{\pm}0.03-3.73{\pm}0.16$) according to the rotation. There was statistical significant difference on horizontal magnification (P < 0.05). Conclusion: In rotated head position, the horizontal magnification should be considered because these can cause distortion on panoramic radiographs.

Investigational Studies on Reproductive Failures of Slaughtered Cows (도살빈우의 번식장애사례 조사연구)

  • 이용빈;임경순
    • Korean Journal of Animal Reproduction
    • /
    • v.6 no.1
    • /
    • pp.19-30
    • /
    • 1982
  • 1. The cows slaughtered at age of 3, 4, 6, 7, 8, and 9 years old were 1.5, 1.5, 15.0, 62.5 and 4.4% respectively. 2. The cows slaughtered at 351-450kg and more than 500kg were 60 and 28% respectively. 3. Best, very good, good and bad cows in nutritional condition were 1.6, 25.8, 62.9, and 9.7% respectively. Among the six cows which were bad nutrition, the two were with severe endometritis, the three were normal in genital function and one was on 70 days of pregnancy. 4. Holstein cows(55.2%) showed higher reproductive failure than the Korean cows(33.3%). 5. The slaughted ratio of the Korean cattle and Holstein cows was 36 and 64% respectively. 6. Pregnant cows were about 16% among the slaughtered one. 7. Reproductive failures were composed of 46% in uterus, 32% in ovaries, 8% in udder, 6% in oviduct, 4% in cervix of uterine, 2% in vagina and 2% inmummified fetus. 8. Forty six percentages of uterine diseases were as follows; horn, 13%, body of uterus, 32% and ovary diseases were 32%, that is, 12% of ovary atrophy, 8% of ovarycyst and 6% of lutealcyst. 9. The cows of reproductive failures were commonly infected with 1.6 kinds of diseases. 10. According to classification, six type of ovaries were as follows; normal, 58%, ovary-cyst, 11%, luteum cyst, 4%, coexistence of follicles and corpus luteum, 16%, weak function of ovaries, 10% and ovarian atrophy, 1%. 11. Major axis, minor axis and thickness of right ovary were larger than those of left one both in Korean cattle and Holstein cows. Holstein cow had generally larger size of ovary than these of the Korean cattle.. 12. The left and right oviducts showed no difference in length, but Holstein had longer oviduct than Korean cow. 13. There was no difference in the length of uterine horn between right and left in the Korean cows, but the right was longer than the left in Holstein cows. 14. Holstein had longer horn and body of uterine than the Korean cows. 15. The weight of right ovary was heavier than that of left in both breeds, but there was no differences in weight of left ovary between two breeds and right ovary of Holstein breed was heavier than that of the Korean cow. 16. The weight of right oviduct and uterine born was heavier than that of the left, and Holstein had heavier oviducts and uterine horns than the Korean cows. 17. Holstein had heavier uterine body and cervix of uterine than the Korean cows. 18. The length of reproductive systems of Korean cow is as follows; Major and minor diameter and thickness ofovary are 3.6${\pm}$0.7, 2.3${\pm}$0.4 and 1.6${\pm}$1.4 cm in left and 3.7${\pm}$0.6, 2.5${\pm}$0.5 and 1.8${\pm}$0.5 cm in right. Oviduct is 28.4${\pm}$3.1 cm in left and 27.8${\pm}$3.3 cm in right. Uterine horn is 27.4${\pm}$4.5 cm in left and 27.7${\pm}$4.9 cm in right. Uterine body and cervix are 3.4${\pm}$1.1 and 6.5${\pm}$1.7 cm. 19. The length of female reproductive systems ofHolstein cow is as follows; Major and minor diameter and thickness of ovary are 3.9${\pm}$1.3, 2.3${\pm}$0.5, and 1.5${\pm}$0.6 cm in left and 4.0${\pm}$0.8, 2.8${\pm}$0.6 and 1.8${\pm}$0.6 cm in right. Oviduct is 29.4${\pm}$4.2 cm in left and 29.3${\pm}$4.1 cm in right. Uterine horn is 30.2${\pm}$7.4 cm in left and 32.6${\pm}$8.4 cm in right. Uterine body and cervix are 4.5${\pm}$2.5 and 7.8${\pm}$2.9 cm. 20. The weight of reproductive systems of Korean cow is as follows; Ovary is 8.4${\pm}$4.1 g in left and 9.3${\pm}$3.6g in right. Oviduct is 1.5${\pm}$0.5 g in left and 1.6${\pm}$0.5 g in right. Uterine horn is 109${\pm}$27 g left and 118${\pm}$32 g in right. Uterine body and cervix are 30.4${\pm}$14.1 and 76.7${\pm}$38.4g. 21. The weight of reproductive systems of Holstein cow is as follows; Ovary is 8.2${\pm}$3.1 g in left and 12.5${\pm}$5.6 g in right. Oviduct is 1.7${\pm}$0.6 g in left and 1.9${\pm}$0.9 g in right. Uterine horn is 199${\pm}$14.2 g in left and 221${\pm}$111.2g in right. Uterine body and cervix are 58.2${\pm}$46.5 and 126.7${\pm}$103.3 g.

  • PDF