• 제목/요약/키워드: $O_2$ saturation

검색결과 653건 처리시간 0.018초

Optimal oxygen saturation in premature infants

  • Chang, Mea-Young
    • Clinical and Experimental Pediatrics
    • /
    • 제54권9호
    • /
    • pp.359-362
    • /
    • 2011
  • There is a delicate balance between too little and too much supplemental oxygen exposure in premature infants. Since underuse and overuse of supplemental oxygen can harm premature infants, oxygen saturation levels must be monitored and kept at less than 95% to prevent reactive oxygen species-related diseases, such as retinopathy of prematurity and bronchopulmonary dysplasia. At the same time, desaturation below 80 to 85% must be avoided to prevent adverse consequences, such as cerebral palsy. It is still unclear what range of oxygen saturation is appropriate for premature infants; however, until the results of further studies are available, a reasonable target for pulse oxygen saturation ($SpO_2$) is 90 to 93% with an intermittent review of the correlation between $SpO_2$ and the partial pressure of arterial oxygen tension ($PaO_2$). Because optimal oxygenation depends on individuals at the bedside making ongoing adjustments, each unit must define an optimal target range and set alarm limits according to their own equipment or conditions. All staff must be aware of these values and adjust the concentration of supplemental oxygen frequently.

꽃게, Portunus trituberculatus 유생의 가스병 발생에 미치는 산소포화도 및 pH의 영향 (Effects of $O_2$ saturation and pH on Gas-bubble disease of blue crab, Portunus trituberculatus)

  • 강주찬;노섬
    • 한국어병학회지
    • /
    • 제8권2호
    • /
    • pp.157-164
    • /
    • 1995
  • 꽃게의 종묘생산시에 많이 이용되고 있는 chlamydomonas sp.를 접종한 green water에서 자연광선조건하에 산소포화도와 pH의 변화가 이들 zoea유생에 미치는 영향을 조사하였다. 사육수의 pH와 산소포화도는 양자 모두 일출과 함께 상승하여 일몰과 함께 저하하는 규칙적인 주야간의 변동을 보였고, pH 8.6 이상으로 조절하였던 실험구의 pH는 최고 9.5 이상으로 상승하였다. 또한 chlamydomonas sp. 농도가 310만 cell/cc 이상인 실험구의 산소포화도는 주간에 118% 이상으로 상승하였으나, 야간에는 급격히 감소하여 100% 이하로 저하하여다. 꽃게 zoea유생의 가스병은 실험개시 4시간후 pH와 산소포화도가 각각 8.5, 118%이상에서 출현하여 수온 및 산소포화도의 저하와 함께 회복하는 경향을 나타내었으나, pH 및 산소포화도의 상승과 함께 연일에 걸쳐 출현하였다. 꽂게 zoea 유생의 사망은 가스병이 관찰된 시점 (pH$\geq$8.5, 산소포화도$\geq$118%)에서부터 발생하기 시작하여 수온, pH 및 산소포화도가 상승할수록 증가하였다.

  • PDF

THE ELECTROMAGNETIC PROPERTIES OF Mg-Mn FERRITES

  • Lee, D.Y.;Cho, S.I.;Shon, H.J.;Hur, W.D.
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.552-555
    • /
    • 1995
  • The magnetic properties of Mg-Mn ferrites were investigated in the composition range of $Mg_{a}Mn_{b}Fe_{c}O_{4\pm\delta}$ (a+b+c=3) with the addition of $Al_{2}O_{3}$. In $MgO-MnO-Fe_{2}O_{3}$ ternary system, the spinel single phase existed within the composition range of MgO-50 mol%, MnO-70 mol% and $Fe_{2}O_{3}-60\;mol%$. The saturation magnetic flux density increased with the increase of $Fe_{2}O_{3}$ content and showed the maximum at the stoichiometric composition of $(Mg,Mn)Fe_{2}O_{4}$. In $Mg_{x}Mn_{1-x}Fe_{2}O_{4}(x=0.2~0.8)$ system, the saturation magnetic flux density showed the maximum at $Mg_{0.2}Mn_{0.8}Fe_{2}O_{4}$. The addition of $Al_{2}O_{3}$ resulted in the decrease of saturation magnetic flux density but increased the electrical resistivity.

  • PDF

Mg-Mn훼라이트의 비자성 이온첨가에 의한 포화자화 감소효과 (A Study on the Effect of Reducing the Saturation Magnetization by Substituting the Non magnetic Ion in Mg Mn Ferrites)

  • 유병두;김종오
    • 한국재료학회지
    • /
    • 제4권1호
    • /
    • pp.117-124
    • /
    • 1994
  • 마이크로웨이브 Mg-Mn훼라이트에서 비자성 이온인 알루미늄으로 Fe 이온을 치환하여 포화자화를 낮출 수 있다. 이것은 마이크로웨이브 훼라이트의 사용 주파수 영역의 확장을 위해 필요하다. 이때 다른 특성의 변화가 수반되는 것은 검토해 봐야 할 점중의 하나이다. 본 연구에서는 MgO: MnO : $Fe_2O_3$를 1.0:0.1:0.95몰비로 제조한 마이크로 웨이브 훼라이트[화학식:$(MgO)_{1.0}(MnO)_{0.1}(Al_xFe_{1.9-x}O_{2.85}$]에서 AI을 0.1에서 0.4까지 첨가한 경우의 전기적.자기적 특성을 미세조직과 아울러 조사하였다. 포화자화 값은 첨가량에 따라 감소하였으며 강자성공명 선폭도 마찬가지였다. $H_c$ 값은 첨가량 0.2이상에서 103.48A/m(1.3Oe)이하로 나타났으며 각형비는 모두 우수하였다. 공명자기장은 첨가량에 따라 거의 변화가 없었다. 이상고 같은 실험결과로부터 적절한 조성범위에서 각각의 물성을 조합하여 넓은 범위의 마이크로웨이브 소자에 응용할 수 있는 제반 물성을 얻을 수 있었다.

  • PDF

Incentive Spirometer를 이용한 심호흡이 시간경과에 따라 늑골골절 환자의 폐기능과 산소포화도에 미치는 영향 (Effects of Deep Breathing with Incentive Spirometer on Pulmonary Function and O2 Saturation by Time Process in Patients with Rib Fracture)

  • 문대환;김계하;이석기
    • 한국콘텐츠학회논문지
    • /
    • 제15권3호
    • /
    • pp.174-183
    • /
    • 2015
  • 본 연구의 목적은 Incentive Spirometer를 이용한 심호흡이 시간경과에 따라 늑골골절 환자의 폐기능과 산소포화도에 미치는 효과를 알아보는 것이다. 연구대상은 G시 소재 일개 병원에 입원한 늑골골절 환자 25명으로 대상자들에게 Incentive Spirometer를 이용한 심호흡이 교육되었다. 자료수집은 2013년 6월부터 10월까지로 폐기능과 산소포화도는 Micro spirometer와 pulse oximeter를 사용하여 입원 시와 중재 1일, 2일, 3일, 4일, 5일, 6일 후에 측정되었다. 자료는 SPSS (Statistical Package for the Social Science) 21.0 version program을 이용하여 기술분석 및 repeated measure ANOVA으로 분석되었다. Incentive Spirometer를 이용한 심호흡을 적용한 후의 폐기능과 산소포화도는 시간이 경과함에 따라 증가하였다. 따라서 늑골골절 환자에게 지속적으로 수행하는 Incentive Spirometer 심호흡이 권장될 필요가 있다.

Morphine과 Ketorolac의 선행진통법이 수술 후 통증, 코티졸, 산소포화도 및 심박동 수에 미치는 효과 (The Effects of Preemptive Analgesia of Morphine and Ketorolac on Postoperative Pain, Cortisol, $O_2$ Saturation and Heart Rate)

  • 서윤주;윤혜상
    • 대한간호학회지
    • /
    • 제38권5호
    • /
    • pp.720-729
    • /
    • 2008
  • Purpose: This study investigated the preemptive analgesic effects of Morphine and Ketorolac on postoperative pain, cortisol, $O_2$ saturation and heart rate for the first 24 hr after abdominal surgery. Methods: Data collection was performed from April 1 to September 30, 2006. Forty patients undergoing a gastrectomy under general anesthesia were randomly allocated to the experimental or control group. The experimental group (20 patients) was administered Morphine and Ketorolac approximately 1 hr prior to skin incision, but the control group (20 patients) was administered Morphine and Ketorolac at peritoneum closure through a patient-controlled analgesia (PCA) pump. Postoperative pain, blood pressure, heart rate, cortisol, $O_2$ saturation, frequency of the PCA button pressed and doses of additional analgesics were observed through post operative 24 hr. Collected data was analyzed using t-test, $X^2$ test, repeated measures ANOVA, and Bonferroni methods. Results: Postoperative pain, cortisol, the frequency of PCA button pressed, and dose of additional analgesics of the experimental group were significantly lower than the control group. There were no statistical differences in blood pressure, heart rate and $O_2$ saturation between the experimental group and control group. Conclusions: We concluded that administration of morphine and ketorolac at 1 hr prior to skin incision resulted in decreasing postoperative pain, but it didn't affect blood pressure, heart rate or $O_2$ saturation for 24 hr after abdominal surgery.

산화 조건에 따른 Cu-Zn Ferrite분말의 자기적 특성 (The Effects of Oxidation Conditions on the Magnetic Properties of Cu-Zn Ferrite Powder)

  • 신광호;사공건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.222-224
    • /
    • 1993
  • In this paper, The optimum oxidation conditions for the formation of Cu-Zn ferrite were investigated using precipitates obtained by the mixture of $CuCl_2{\cdot}2H_2O$, $ ZnCl_2$, $FeCl_3{\cdot}6H_2O$ and NaOH. The precipitates were prepared by coprecipitation method on various temperatures and oxidation conditions. The oxidation products were examined by SEM, XRD, and VSM. The particles obtained at 70($^{\circ}C$) were more spherical and fine than that of prepared at 25($^{\circ}C$), 50($^{\circ}C$), 60($^{\circ}C$), respectively. By $H_2O_2$ oxidation, the saturation magnetization of the powders was little influenced, But, by air oxidation the saturation magnetization of the powders was influenced intricately. According to our experimental data, the saturation magnetization of the powders increased with reaction time and was saturated at 9 hours.

  • PDF

A Design and Implementation of SpO2 Wearable Device for Companion Animals in PPG Signals

  • Kim, Woo-Chan;Chang, Jin-Wook;Kwon, Hoon;Lee, Won Joo;Kwak, Ho-Young
    • 한국컴퓨터정보학회논문지
    • /
    • 제27권11호
    • /
    • pp.191-198
    • /
    • 2022
  • 반려동물의 상태 측정에서 가장 기본적인 사항은 호흡과 맥박의 체크이다. 반려동물의 호흡과 맥박을 측정하는 방법은 여러 가지가 있는데, 반려동물에게서 산소포화도(SpO2)를 측정하기 위해서는 일반적으로 PPG 방식을 많이 사용한다. 그러나 입력되는 PPG 신호는 산소포화도뿐만 아니라 여러 정보가 섞여서 입력되기 때문에 산소포화도를 측정하기 위해서는 PPG 신호로부터 산소포화도 정보를 분리하여 추출해야만 한다. 따라서 본 논문에서는 PPG 방식을 적용하여 측정할 수 있는 반려동물용 웨어러블 측정 장치를 설계하고 구현하였으며, 이 웨어러블 측정 장치를 통해 입력되는 PPG 신호에서 산소포화도 정보를 분리하는 알고리즘을 제안하였다.

광대역 광원을 이용한 혈중 산소포화도의 측정 시스템 및 랩뷰 프로그램 (Measurement of Blood Oxygen Saturation System and LavVIEW Program Using Broad-band Light Source)

  • 최금실;신동호;송철규
    • 한국멀티미디어학회논문지
    • /
    • 제18권2호
    • /
    • pp.128-137
    • /
    • 2015
  • Blood oxygen saturation ($SpO_2$) is so important to be called bio-signal of the fifth. The measurement of blood oxygen saturation based on broad-ban light source has advantages of simple testing facility and easy understanding. This paper proposes a LabVIEW program which measures blood oxygen saturation based on broad-band light source. It combines LabVIEW and MATLAB, utilizing different light absorptions of oxyhemoglobin and deoxyhemoglobin in the visual wavelength range of 450nm-750nm to determine blood oxygen saturation. In order to improve accuracy through reducing the impact of hand shaking, the probe is fixed to the motor stage and then move a constant distance between the probe and the sample to be measured. Experimental results show that the proposed method noticeably increases the accuracy and saves time compared with the conventional methods.

Fe_2O_3-CaO-SiO_2$계 결정화 유리의 제조 및 특성(I) (Characterization and Preparation of Glass-Ceramics in the System Fe_2O_3-CaO-SiO_2$ (I))

  • 이용근;최세영;김경남
    • 한국세라믹학회지
    • /
    • 제31권6호
    • /
    • pp.629-636
    • /
    • 1994
  • The ferrimagnetic glass-ceramics in the system Fe2O3-CaO-SiO2 for hyperthermia were investigated. Glasses could be prepared up to the content of 40 wt% of Fe2O3 and below the weight ratio of 1.0 of CaO/SiO2. The maximum saturation magnetization and the maximum coercive force were 29.85 emu/g and 340.1 Oe respectively, for a glass 40Fe2O3.20CaO.40SiO2 composition heat-treated at 95$0^{\circ}C$ for 8 hours. And for a glass 40Fe2O3.30CaO.30SiO2 composition the maximum saturation magnetization and the maximum coercive force were 18.47 emu/g and 374.4 Oe heat-treated at 1,00$0^{\circ}C$ and 90$0^{\circ}C$ for 8 hours respectively. The maximum hysteresis loss was 1,726.3 cal/g for a glass 40Fe2O3.20CaO.40SiO2 composition heat-treated at 95$0^{\circ}C$ for 8 hours. It was found that the ferrimagnetic Fe2O3.CaO.SiO2 glass-ceramics was little injurious to human body as results of biocompatibility test and biotoxicity test.

  • PDF