• Title/Summary/Keyword: $O_2$ Sensor

Search Result 1,272, Processing Time 0.029 seconds

Effect of Microstructure on Piezoelectric Properties and TCC Behavior in PZT-PZN Ceramics (PZT-PZN 세라믹의 미세구조가 압전 특성 및 TCC 거동에 미치는 영향)

  • Seo, Intae;Choi, Yongsu;Cho, Yuri;Kang, Hyung-Won;Kim, Kang San;Cheon, Chae Il;Han, Seung Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.5
    • /
    • pp.445-451
    • /
    • 2022
  • Ultrasonic sensor is suitable as a next-generation autonomous driving assist device because its lower price compared to that of other sensors and its sensing stability in the external environment. Although Pb(Zr, Ti)O3 (PZT)-relaxor ferroelectric system has excellent piezoelectric properties, the change in capacitance is large in the daily operating temperature range due to the low phase transition temperature. Recently, many studies have been conducted to improve the temperature stability of ferroelectric ceramics by controlling the grain size and crystal structure, so it is necessary to study the effect of the grain size on the piezoelectric properties and the temperature stability of PZT-relaxor ferroelectric system. In this study, the piezoelectric properties, phase transition temperature, and temperature coefficient of capacitance (TCC) of 0.9 Pb(Zr1-xTix)O3-0.1 Pb(Zn1/3Nb2/3)O3 (PZTx-PZN) ceramics with various grain sizes were investigated. PZTx-PZN ceramics with larger grain size showed higher piezoelectric properties and temperature stability, and are expected to be suitable for ultrasonic devices in the future.

The Characteristic of Hybrid X-ray Sensor for Synchrotron Radiation image (싱크로트론 방사선 영상 획득을 위한 Hybrid 기반의 X선 센서 제작 및 특성)

  • Cha, Byong-Yoel;Kang, Sang-Sick;Kim, So-Young;Yoon, Kyoung-Jun;Mun, Chi-Woong;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.04b
    • /
    • pp.68-71
    • /
    • 2004
  • 본 연구는 싱크로트론 방사광의 단색광 (monobeam)을 이용한 영상을 획득하였다. 영상센서로서 CMOS를 사용하였으며 센서 앞단에는 형광체 (phosphor)를 이용하여 방사광에 대한 빛의 신호로서 영상을 획득하였다. 사용된 싱크로트론 방사광의 beam size는 $5mm{\times}2mm$ 이며 ion chamber를 통한 beam intensity 는 $10{\times}10^{-7}$이다. 형광체는 각각 ZnS(Cu:Al), ZnS(Ag,Al), $BiTiO_3$, $Y_2O_2S(Tb)$로서 4가지를 사용하였으며 여기에 사용된 형광체는 기계식 스크린 프린팅 (Screen Printing) 방식으로 직접 제조하였다. 두께는 모두 동일하게 $10{\mu}m$이며 각각에 대한 PL(Photoluminescence)을 측정하여 분석하였다. object로는 물고기와 20linepair를 사용하였으며 CMOS센서를 이용하여 각각의 phosphor에 대하여 영상을 획득하였다. 영상의 평가는 20line pair 영상의 MTF를 이용하였다. 각각의 형광체에 대한 MTF는 5 lp/mm 에서는 0.5650, 0.2150, 0.7890, 0.3840 이며 10 lp/mm 은 0.4500, 0.0900, 0.2510, 0.1500이고 15 lp/mm 는 0.1900, 0.0300, 0.1430, 0.0500이며 마지막으로 20 lp/mm 은 0.0810, 0.004, 0.0500, 0.0320의 MTF 값을 나타내었다. $10{\mu}m$ 두께에 대하여 ZnS(Cu:Al)이 가장 좋은 MTF의 값을 나타내었다.

  • PDF

A Study For The Simple Method In Dividing The Layers of Fiber-reinforced Plastic (폐 FRP선박의 재활용공정에서 용이한 면포추출공정을 위한 화학적 처리 방법에 관한 연구)

  • Lee, Seung-Hee;Kim, Yong-Seop;Yoon, Koo-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.1
    • /
    • pp.43-46
    • /
    • 2010
  • As one of the methods for recycling the FRP used for the small and medium-sized waste ships, separation of the roving layer from the mat has some merit in a sense of the recycling energy and the environmental effects. Similar characteristics between the roving and the mat make the mechanically automatic differentiation difficult. They, however, contain different ratio of the resin and the glass and the thickness. In this study photo physical differentiation between the two layers has been made using (1) boiling concentrated sulfuric acid which can dissolve the resin in the FRP layer and (2) hydrogen fluoride(HF) solution which can reacts with $SiO_2$ fragments of the glass. Furthermore coloring the FRP sample with water-soluble dye following the HF treatment makes the roving layer more distinguishable photophysically. The implementation of HF treatment has been successfully tested in this study.

Fabrication and Electrical Property Analysis of [(Ni0.3Mn0.7)1-xCux]3O4 Thin Films for Microbolometer Applications (마이크로볼로미터용 [(Ni0.3Mn0.7)1-xCux]3O4 박막의 제작 및 전기적 특성 분석)

  • Choi, Yong Ho;Jeong, Young Hun;Yun, Ji Sun;Paik, Jong Hoo;Hong, Youn Woo;Cho, Jeong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.41-46
    • /
    • 2019
  • In order to develop novel thermal imaging materials for microbolometer applications, $[(Ni_{0.3}Mn_{0.7})_{1-x}Cu_x]_3O_4$ ($0.18{\leq}x{\leq}0.26$) thin films were fabricated using metal-organic decomposition. Effects of Cu content on the electrical properties of the annealed films were investigated. Spinel thin films with a thickness of approximately 100 nm were obtained from the $[(Ni_{0.3}Mn_{0.7})_{1-x}Cu_x]_3O_4$ films annealed at $380^{\circ}C$ for five hours. The resistivity (${\rho}$) of the annealed films was analyzed with respect to the small polaron hopping model. Based on the $Mn^{3+}/Mn^{4+}$ ratio values obtained through x-ray photoelectron spectroscopy analysis, the hopping mechanism between $Mn^{3+}$ and $Mn^{4+}$ cations discussed in the proposed study. The effects of $Cu^+$ and $Cu^{2+}$ cations on the hopping mechanism is also discussed. Obtained results indicate that $[(Ni_{0.3}Mn_{0.7})_{1-x}Cu_x]_3O_4$ thin films with low temperature annealing and superior electrical properties (${\rho}{\leq}54.83{\Omega}{\cdot}cm$, temperature coefficient of resistance > -2.62%/K) can be effectively employed in applications involving complementary metal-oxide semiconductor (CMOS) integrated microbolometer devices.

Dynamic Quasi-Elastic Light Scattering Measurement of Biological Tissue

  • Youn, Jong-In;Lim, Do-Hyung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.169-173
    • /
    • 2007
  • During laser irradiation, mechanically deformed cartilage undergoes a temperature dependent phase transformation resulting in accelerated stress relaxation. Clinically, laser-assisted cartilage reshaping may be used to recreate the underlying cartilaginous framework in structures such as ear, larynx, trachea, and nose. Therefore, research and identification of the biophysical transformations in cartilage accompanying laser heating are valuable to identify critical laser dosimetry and phase transformation of cartilage for many clinical applications. quasi-elastic light scattering was investigated using Ho : YAG laser $(\lambda=2.12{\mu}m\;;\;t_p\sim450{\mu}s)$ and Nd:YAG Laser $(\lambda=1.32{\mu}m\;;\;t_p\sim700{\mu}s)$ for heating sources and He : Ne $(\lambda=632.8nm)$ laser, high-power diode pumped laser $(\lambda=532nm)$, and Ti : $Al_2O_3$ femtosecond laser $(\lambda=850nm)$ for light scattering sources. A spectrometer and infrared radiometric sensor were used to monitor the backscattered light spectrum and transient temperature changes from cartilage following laser irradiation. Analysis of the optical, thermal, and quasi-elastic light scattering properties may indicate internal dynamics of proteoglycan movement within the cartilage framework during laser irradiation.

Electrical characteristics of carbon nitride capacitor for micro-humidity sensors (마이크로 습도센서를 위한 질화탄소막 캐패시터의 전기적 특성)

  • Kim, Sung-Yeop;Lee, Ji-Gong;Chang, Choong-Won;Lee, Sung-Pil
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.97-103
    • /
    • 2007
  • Crystallized carbon nitride film that has many stable physical and/or chemical properties has been expected potentially by a new electrical material. However, one of the most significant problems degrading the quality of carbon nitride films is an existence of N-H and C-H bonds from the deposition environment. The possibility of these reactions with hydroxyl group in carbon nitride films, caused by a hydrogen attack, was suggested and proved in our previous reports that this undesired effect could be applied for fabricating micro-humidity sensors. In this study, MIS capacitor and MIM capacitor with $5{\mu}m{\times}5{\mu}m$ meshes were fabricated. As an insulator, carbon nitride film was deposited on a $Si_{3}N_{4}/SiO_{2}/Si$ substrate using reactive magnetron sputtering system, and its dielectric constant, C-V characteristics and humidity sensing properties were investigated. The fabricated humidity sensors showed a linearity in the humidity range of 0 %RH to 80 %RH. These results reveal that MIS and MIM $CN_{X}$ capacitive humidity sensors can be used for Si based micro-humidity sensors.

Recognition of Microorganisms Using SPR Biosensor Immobilized with Thiolated Antibody (티올화 항체고정형 SPR 바이오센서를 이용한 미생물 인식)

  • 조용진;김남수
    • Journal of Biosystems Engineering
    • /
    • v.28 no.2
    • /
    • pp.167-172
    • /
    • 2003
  • This study was performed to fabricate a batch-type SPR biosensing system using a thiolated E. coli antibody coupling, and to explore the feasibility of real-time detection of E. coii in a stagnant sample solution. In advance. “O” and “K” antigenic serotype E. coli antibodies were thiolated with sulfo-LC-SPDP and dithiothreitol, and immobilized by chemisorption in the gold surface of compact SPR sensors. When the SPR biosensor immobilized with E. coli antibody monitored a E. coli solution, it took 3 to 5 min to stabilize. The SPR biosensing system developed in this study was able to detect E. coli in the range above 10$^4$ CFU/mL at the 0.05 significant level. Also, the SPR biosensor had possibility to significantly detect E. coli in the range of 10$^2$ to 10$^4$ CFU/mL in E. coli solutions. Meanwhile, when the SPR biosensor immobilized with 5. coli antibody was cleaned with NaOH solutions, its ability to detect E. coli largely decreased due to wash-out of the immobilized antibody. In order to reuse the SPR sensor, it should be antibody-immobilized newly.

Optimization of Measuring Cardiac Output by Both Hands Electrode Impedance Method (양손 전극의 임피던스법을 이용한 심박출량 측정의 최적화)

  • Jung, Sang-O;Sim, Myeong-Heon;Jung, Woon-Mo;Kim, Min-Yong;Yoon, Chan-Sol;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.9
    • /
    • pp.1770-1776
    • /
    • 2011
  • In this study, a new method that can estimate ICG data from a subject's both hands to measure Cardiac Output under convenient sensor environment. With this aim, a grip-type electrode was implemented to measure ICG. To improve the accuracy of measurement, the regression equation was extracted using multiple bio-parameters and our result was compared with the thoracic ICG equipment(Physio Flow$^{(R)}$, PF104D, Manatec Biomedical, France), which is being used in clinics. The subjects consist of 26 men and 4 women(age in $22.0{\pm}3.32$). They are no cardiac disease. Parameters available for regression model were used gender, BMI, MBP, LVET, dZ/dt(max), distance between the measured electrodes, body impedance, and PTT. As a result of analyzing the ICG measurement value on thorax and both hands, the correlation with stroke volume, heart rate, and cardiac output was $R^2$=0.853, $R^2$=0.958 and $R^2$=0.899, respectively.

Functional switching of eukaryotic 2-Cys peroxiredoxins from peroxidases to molecular chaperones in response to oxidative stress

  • Jang, Ho-Hee;Lee, Sang-Yeol
    • Proceedings of the Korean Society of Plant Biotechnology Conference
    • /
    • 2005.11a
    • /
    • pp.40-64
    • /
    • 2005
  • Much biochemical information on peroxiredoxins (Prxs) has been reported but a genuine physiological function for these proteins has not been established. We show here that two cytosolic yeast Prxs, cPrxI and II, exist in a variety of forms that differ in their structure and molecular weight (MW) and that they can act both as a peroxidase and as a molecular chaperone. The peroxidase function predominates in the lower MW proteins, whereas the chaperone function is more significant in the higher MW complexes. Oxidative stress and heat shock exposure of yeasts causesthe protein structures of cPrxI and II to shift from low MW species to high MW complexes. This triggers a peroxidase-to-chaperone functional switch. These in vivo changes are primarily guided by the active peroxidase site residue, $Cys^{47}$, which serves as an efficient $'H_2O_2-sensor'$ in the cells. The chaperone function of the proteins enhances yeast resistance to heat shock.

  • PDF

Gas Sensing Properties of Nanocrystalline ITO Thick Films with Different Particle Sizes (입자 크기에 따른 ITO 후막 센서의 가스 감지 특성)

  • Shin, D.W.;Lee, S.T.;Jun, H.K.;Lee, D.D.;Lim, J.O.;Huh, J.S.
    • Korean Journal of Materials Research
    • /
    • v.13 no.2
    • /
    • pp.106-110
    • /
    • 2003
  • Nano-sized powders of Indium Tin Oxide(ITO) were synthesized by a coprecipitation method. In order to investigate the gas sensing characteristics in the nanocrystalline ITO thick films with various particle sizes, ITO powders with the average particle diameter of 15, 30, and 70 nm respectively were synthesized. And the sensitivity of ITO thick films was measured upon exposure to a target gas($C_2$$H_{5}$ /OH) and some other Volatile Organic Compounds(VOCs), such as, toluene, methanol, benzene, chloroform. As a result, ITO thick films had high sensitivity for ethanol and higher sensitivity with smaller particle size.