• Title/Summary/Keyword: $NO_x$ removal

Search Result 252, Processing Time 0.02 seconds

The Effect of Flushing Solutions on ElectroKinetic Remediation of Ferrous Soil Contaminated by Lead (납으로 오염된 철성분 함유토의 동전기 정화 특성에 세척제가 미치는 영향)

  • 김수삼;김병일;한상재;김정환
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.54-62
    • /
    • 2004
  • In order to enhance the efficiency of removal a series of ElectroKinetic Remediation (EKR) tests on ferrous soil contaminated by lead are carried out using acids, chelates and surfactant as flushing agents. The test results indicate that pH in the electrolyte rapidly reached at steady state as the introduce of flushing solution of the lower pH, the type of flushing solution have no effect the distribution of electrical voltage within the sample but the increasing of solution concentration increases it at x/L=0.9. In the distribution of the residual lead in the sample SDS is the highest. Also, the removal efficiency for acetic acid concentration of 1mM Is the highest but the concentration of acetic acid significantly have no effect.

Gastrointestinal Foreign Bodies in Children -Experiences of 60 Cases in Kangwon, Korea- (소아 위장관 이물 -강원지역 소아 60례-)

  • Lee, Young-Sub;Kang, Kae-Wool;Choi, Won-Kyu
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.148-154
    • /
    • 2001
  • Purpose: Ingested foreign bodies present a common clinical problem. It is well known that most of them pass uninterrupted through the gastrointestinal tract. We evaluated the role of endoscopy and Foley catheter for removal of foreign bodies in the gastrointestinal tract. Methods: We investigated retrospectively 60 cases with foreign bodies in the gastrointestinal tract. They had been treated at Wonju Christian Hospital, Yonsei University of Korea, from January, 1996 through December, 1999. Results: The age of the patients ranged from 7 months to 13 years. Patients under 5 years were 57 cases (97%) and there was no significant difference in sex (M : F=1.07 : 1). 45 cases of the patients had no symptom. The most common foreign bodies were coins (43 cases). The most common location was esophagus (31 cases). The number of foreign body removal using flexible endoscopy and Foley catheter was 22 (36.7%) and 18 (30.0%) cases, respectively. In 18 cases (30.0%), foreign bodies passed spontaneously. Only 1 case (1.7%), curtain pin impaction at ileocecal region, required surgery. Conclusion: Early foreign body removal from esophagus and stomach is recommended to lessen the morbidity and complication. Fluoroscopic foley catheter technique and flexible endoscopy for removal of esophageal foreign bodies in children is safe and effective.

  • PDF

Removal of Oil from Soil Using Nonionic Surfactant : The Effects of Middle Phase Formation and Dynamic Interfacial Tension (비이온 계면활성제를 사용한 토양으로부터 오일의 제거에 관한 연구 : 중간상생성 및 동적 계면장력의 영향)

  • Lee, Kee-Suh;Kim, Young-Ho;Kim, Chul-Ung;Lee, Jung-Min;Koo, Kee-Kahb
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • The soil remediation by non-ionic surfactant solutions ($C_{12}H_{25}O(CH_2CH_2O)_5H$ and Triton X-100) was studied. Depending on the amounts and use of co-surfactants, MPT(phase inversion temperature), dynamic interfacial tension, and the detergency efficiency of the surfactant solutions in soil were investigated. The oils used were kerosene, n-hexadecane, and paraffin oil. With respect to a higher detergency efficiency, a lower interfacial tension and the MPT was very important. The $C_{12}H_{25}O(CH_2CH_2O)_5H$ was better than Triton X-100 on the oil removal from the soil and the effect of oil kinds was kerosene>paraffin $oil{\geq}n-hexadecane$. The co-surfactant, n-dodecanol, reduced the MPT compared to no addition of this, whereas it did not enhance the detergent efficiency.

  • PDF

Comparative Study of Enzyme Activity and Stability of Bovine and Human Plasmins in Electrophoretic Reagents, β-mercaptoethanol, DTT, SDS, Triton X-100, and Urea

  • Choi, Nack-Shick;Hahm, Jeung-Ho;Maeng, Pil-Jae;Kim, Seung-Ho
    • BMB Reports
    • /
    • v.38 no.2
    • /
    • pp.177-181
    • /
    • 2005
  • Effects of common electrophoretic reagents, reducing agents ($\beta$-mercaptoethanol [BME] and DTT), denaturants (SDS and urea), and non-ionic detergent (Triton X-100), on the activity and stability of bovine plasmin (b-pln) and human plasmin (h-pln) were compared. In the presence of 0.1% SDS (w/v), all reagents completely inhibited two plns, whereas SDS (1%) and urea (1 M) denatured plns recovered their activities after removal of SDS by treatment of 2.5% Triton X-100 (v/v). However, reducing agents (0.1 M of BME and DTT) treated plns did not restore their activities. Based on a fibrin zymogram gel, five (from b-pln) and four (from h-pln) active fragments were resolved. Two plns exhibited unusual stability in concentrated SDS and Triton X-100 (final 10%) and urea (final 6 M) solutions. Two bands, heavy chain-2 (HC-2) and cleaved heavy chain-2 (CHC-2), of b-pln were completely inhibited in 0.5% SDS or 3 M urea, whereas no significant difference was found in h-pln. Interestingly, 50 kDa (cleaved heavy chain-1, CHC-1) of b-pln and two fragments, 26 kDa (light chain, LC) and 29 kDa (microplasmin, MP), of h-pln were increased by SDS in a concentration dependent manner. We also found that the inhibition of SDS against both plns was reversible.

Selective Catalytic Reduction (SCR) Technology Trend for the Removal of Nitrogen Oxide from Ship Flue Gas (선박 배가스 내 질소산화물 제거를 위한 선택적촉매환원법(SCR) 기술동향)

  • Won, Jong Min;Hong, Sung Chang
    • Prospectives of Industrial Chemistry
    • /
    • v.22 no.5
    • /
    • pp.25-40
    • /
    • 2019
  • 전 세계적으로 환경문제를 해결하기 위한 방안으로 환경규제를 강화시키며 특히 다양한 대기오염 물질 중 최근 큰 이슈인 초미세먼지 저감을 위해 전구물질로 알려진 질소산화물을 제어하기 위한 다양한 기술개발이 가속화되고 있다. 특히, 다양한 처리기술 중에 기술적·경제적인 이점을 갖춘 선택적 촉매환원법(selective catalytic reduction, SCR) 기술을 통하여 질소산화물 제거를 위해 암모니아를 환원제로 반응에 참여시켜 인체에 무해한 H2O, N2로 전환하는 기술이 대표적이다. 최근 전 세계적으로 다양한 산업군에서 질소산화물이 배출되고 있으며, 점오염원뿐만이 아니라 비점오염원(mobile sources)에 대한 규제가 강화되고 있다. 디젤엔진이 장착된 선박 배가스 처리장치 내 SCR 기술이 주목을 받고 있으며, NH3-SCR에 사용되는 촉매는 주로 VOx/TiO2, VOx/W/TiO2 촉매가 대표적이다. 한편 선박 디젤엔진에 사용되는 연료에 따라 연소배가스 특성이 다르다. 이러한 연료가 연소됨에 따라 SO2, SO3가 발생되고 환원제인 NH3와 결합하여 황산암모늄염((NH4)2SO4), ABS (ammonium bisulfate, NH4HSO4)과 같은 염을 형성시켜 탈질촉매의 비활성화 문제가 발생된다. 이러한 비활성화 물질이 침적된 탈질촉매를 재활성화 시키기 위하여 열 산화를 통해 재생시키고 있다. 이처럼 선박용 SCR 촉매는 강화되는 배출규제 및 엔진기술의 발달로 저감되는 운전 온도에 대비하여 저온 활성 재생이 가능한 고활성, 고내구성 촉매기술 개발이 필요하다.

Impact of different agitation methods on smear layer cleaning of mesial canals with accentuated curvature

  • Abel Teves Cordova;Murilo Priori Alcalde;Michel Espinosa Klymus;Leonardo Rigoldi Bonjardim;Rodrigo Ricci Vivan;Marco Antonio Hungaro Duarte
    • Restorative Dentistry and Endodontics
    • /
    • v.49 no.2
    • /
    • pp.12.1-12.10
    • /
    • 2024
  • Objectives: This study evaluated the impact of different methods of irrigant agitation on smear layer removal in the apical third of curved mesial canals of 3 dimensionally (D) printed mandibular molars. Materials and Methods: Sixty 3D-printed mandibular second molars were used, presenting a 70° curvature and a Vertucci type II configuration in the mesial root. A round cavity was cut 2 mm from the apex using a trephine of 2 mm in diameter, 60 bovine dentin disks were made, and a smear layer was formed. The dentin disks had the adaptation checked in the apical third of the teeth with wax. The dentin disks were evaluated in environmental scanning electron microscope before and after the following irrigant agitation methods: G1(PIK Ultrasonic Tip), G2 (Passive Ultrasonic Irrigation with Irrisonic- PUI), G3 (Easy Clean), G4 (HBW Ultrasonic Tip), G5 (Ultramint X Ultrasonic tip), and G6 (conventional irrigation-CI) (n = 10). All groups were irrigated with 2.5% sodium hypochlorite and 17% ethylenediaminetetraacetic acid. Results: All dentin disks were 100% covered by the smear layer before treatment, and all groups significantly reduced the percentage of the smear layer after treatment. After the irrigation protocols, the Ultra-X group showed the lowest coverage percentage, statistically differing from the conventional, PIK, and HBW groups (p < 0.05). There was no significant difference among Ultramint X, PUI-Irrisonic, and Easy Clean (p > 0.05). None of the agitation methods could remove the smear layer altogether. Conclusions: Ultramint X resulted in the most significant number of completely clean specimens.

Nitrite Accumulation Characteristics According to Hydraulic Retention Time and Aeration Rate in a Biological Aerated Filter (생물여과 반응기에서 수리학적 체류시간 및 폭기량에 따른 아질산 축적 특성)

  • Yoon, Jong Moon;Kim, Dong Jin;Yoo, Ik-Keun
    • Korean Chemical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.200-206
    • /
    • 2006
  • In a biological aerated filter (BAF) packed with ceramic media (void fraction of BAF=0.32), nitrite accumulation was studied with the variation of hydraulic retention time (HRT) and superficial air velocity. Synthetic ammonium wastewater and petrochemical wastewater were fed at a constant load of $1.6kgNH_4^+-N/m^3{\cdot}d$. Ammonium removal rate was mainly affected by the superficial air velocity in BAF, but nitrite ratio($NO_2-N/NO_x-N$) in the effluent was dependent on both HRT and superficial air velocity. For a fixed HRT of 0.23 hr (corresponding to the empty bed contact time of 0.7 hr) ammonium removal rate was 73/90/92% and nitrite ratio was 0.92/0.82/0.48 at the superficial air velocity of 0.23/0.45/0.56 cm/s, respectively. When HRT is increased to 0.9 hr with superficial air velocity ranging from 0.34 to 0.45 cm/s, the ammonium removal rate was 89% on average. However nitrite ratio decreased significantly down to 0.13. When HRT was further increased to 1.4 hr, ammonium removal rate decreased, thereby resulting in the free ammonia ($NH_3-N$, FA) build-up and nitrite ratio gradually increased (>0.95). Although aeration rate and FA concentration at HRT of 0.23 hr were unfavorable for nitrite accumulation compared with those at HRT of 0.9 hr, nitrite ratio at HRT of 0.23 hr was higher. Taken together, HRT and nitrogen load were found to be critical, in addition to FA concentration and aeration condition, for nitrite accumulation in the BAF tested in the present study.

On-stream Activity and Surface Chemical Structure of CoO2/TiO2 Catalysts for Continuous Wet TCE Oxidation (습식 TCE 분해반응에서 CoO2/TiO2 촉매의 반응활성 및 표면화학적 구조)

  • Kim Moon Hyeon;Choo Kwang-Ho
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.221-230
    • /
    • 2005
  • Catalytic wet oxidation of trichloroethylene (TCE) in water has been conducted using $TiO_2-supported$ cobalt oxides at $36^{\circ}C$ with a weight hourly space velocity of $7,500\;h^{-1}.\;5\%\;CoO_x/TiO_2$, prepared by using an incipient wetness technique, might be the most promising catalyst for the wet oxidation although it exhibited a transient behavior in time on-stream activity. Not only could the bare support be inactive for the wet decomposition reaction, but no TCE removal also occurred by the process of adsorption on $TiO_2$ surface. The catalytic activity was independent of all particle sizes used, thereby representing no mass transfer limitation in intraparticle diffusion. XPS spectra of both fresh and used Co surfaces gave different surface spectral features for each $CoO_x,\;Co\;2P_{3/2}$ binding energy for Co species in the fresh catalyst appeared at 781.3 eV, which is very similar to the chemical states of $CoTiO_x$ such as $CO_2TiO_4\;and\;CoTiO_3$. The used catalyst exhibited a 780.3-eV main peak with a satellite structure at 795.8 eV. Based on XPS spectra of reference Co compound, the TCE-exposed Co surfaces could be assigned to be in the form of mainly $Co_3O_4$. XRD patterns for $5\%\;CoO_x/TiO_2$ catalyst indicated that the phase structure of Co species in the catalyst even before reaction is quite comparable to the diffraction lines of external $Co_3O_4$ standard. A model structure of $CoO_x$ present predominantly on titania surfaces would be $Co_3O_4$, encapsulated in thin-film $CoTiO_x$ species consisting of $Co_2TiO_4$ and $CoTiO_3$, which may be active for the decomposition of TCE in a flow of water.

A Study on Biofilm Detachment in an IFBBR (역 유동층 생물막 반응기에서의 생물막 탈착에 관한 연구)

  • 김동석;박영식
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.263-271
    • /
    • 1994
  • A detachment of biofilm was investigated in an inverse fluidized bed biofilm reactor(IFRBR). The biofilm thickness, 5 and the bioparticle density, Pm were decreased by the increase of Reynolds number, Re and the decrease of biomass concentration, h. The correlations were expressed as $\delta$=6l.6+16.33$b_c$-0.004Re and Ppd=0.3+0.027$b_c$- 2.93x$l0^{-5}$ no by multiple linear regression analysis method. Specific substrate removal rate, q was derived by F/M ratio and biofilm thickness as q=0.44.+0.82F/M-5.Ix10$-4^{$\delta$}$. Specific biofilm detachment rate, bds was influenced by FIM ratio and Reynolds number as $b_{ds}$=-0.26+0.26F/M+ 2.17$\times$$10^{-4}$Re. Specific biofilm deachment rate in an IFBBR was higher than that in a FBRR(fluidized bed biofilm reactor) because of the friction between air bubble and the bioparticles.

  • PDF

Isolated calcific tendinitis at the posterosuperior labrum: a rare case study

  • Suh, Dong-Hwan;Ji, Jong-Hun;Kim, Chang-Yeon
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.4
    • /
    • pp.194-197
    • /
    • 2020
  • Calcific tendinitis of the shoulder joint, also known as chemical furuncle of the shoulder, causes intense shoulder pain and usually occurs within 1-2 cm from the insertion of the rotator cuff. We experienced a rare case of calcific tendinitis in the posterosuperior labrum of the shoulder joint in a 39-year-old male patient who presented with severe pain and weakness in the right shoulder. Radiographs and magnetic resonance imaging (MRI) findings showed calcific tendinitis in the posterosuperior labrum of the shoulder joint. A 1-week attempt at conservative treatment failed, so the calcified deposit in the posterosuperior labrum was arthroscopically removed. The patient's symptoms were completely relieved, and satisfactory clinical outcomes were achieved. Postoperative follow-up X-ray and MRI showed no recurrence of calcific tendinitis.