• Title/Summary/Keyword: $NO_2/NO_x$ ratio

Search Result 545, Processing Time 0.035 seconds

A Study on Characteristics of Alloy Materials through Reproduction Experiment of High-tin Bronze Mirror with Geometric Designs (고주석 청동정문경(靑銅精文鏡)의 재현실험을 통한 합금재료의 특성 연구)

  • Lee, In Kyeong;Jo, Young Hoon;Cho, Nam Chul
    • Journal of Conservation Science
    • /
    • v.35 no.5
    • /
    • pp.508-517
    • /
    • 2019
  • This study analyzed on alloys and by-product samples produced through the reproduction experiment of bronze mirror with geometric designs. The alloy ratio used in the first and second reproduction experiments was based on the analysis results of bronze mirror with geometric designs(Cu 61.68%, Sn 32.25%, Pb 5.46%) which is the national treasure No. 141. As a result of portable X-ray fluorescence analysis on the raw materials used in the reproduction experiment, the contents of copper raw materials were 98.85 wt% for Cu, tin raw materials were 99.03 wt% for Sn, and lead raw materials were 70.19 wt% for Pb, and 21.81 wt% for Sn. Sn and Pb were added 5 wt% more considering the evaporation amount of tin and lead during alloy melting. The result produced by the first reproduction experiment were 58.75 wt% for Cu, 36.87 wt% for Sn, 4.39 wt% for Pb, and the other result produced by the second reproduction experiment were 58.66 wt% for Cu, 35.89 wt% for Sn, and 5.50 wt% for Pb. The composition of the components was about 3.00 wt% in Cu and Sn respectively, and the microstructure was similar to the previous studies because the δ phase was observed mainly. The results of this study will be used as basic data for the materialistic characteristics of ancient bronze mirror in the future.

Analysis of the Relationships Between ESD and DAP, and Image SNR·CNR According to the Frame Change of Cine Imaging in CAG : With Focus on 10 f/s and 15 f/s (심장혈관 조영술에서 씨네(cine)촬영의 프레임변화에 따른 ESD와 DAP 및 영상의 SNR·CNR 관계 분석: 10f/s과 15f/s을 중심으로)

  • Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.669-675
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing entrance surface dose and absorbed dose according to the frame change in coronary angiography using an X-ray machine. Moreover, appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring and analyzing the SNR and CNR of the image through image J. The study was conducted on 30 patients (19 males and 11 females) who underwent CAG at this hospital from June 2017 to October 2017. In regard to the patients, their age range was 49-82 years (mean of $65{\pm}9$ years), body weight was 45-91 kg (mean of $67{\pm}8.9kg$), height was 150-179cm (mean of $165.1{\pm}8.9kg$), and BMI was 19.5-30.5(mean of $24.5{\pm}2.9$). For the entrance surface dose and absorbed dose, air kerma value and DAP were obtained and analyzed retrospectively. The SNR and CNR were measured and analyzed through imageJ, and the result values were derived by applying the values to the formula. As for the statistical analyses, the correlations between the entrance surface dose and absorbed dose, and between the SNR and CNR were analyzed by using the SPSS statistical program. The relationship between the entrance surface dose and absorbed dose was not statistically significant for both 10 f/s and 15 f/s (p>0.05). In terms of the relationship between the SNR and CNR, the SNR ($3.374{\pm}2.1297$) and CNR ($0.234{\pm}0.2249$) in 10 f/s were $1.43{\pm}0.4861$ and $0.132{\pm}0.0555$ lower, respectively, than the SNR ($4.929{\pm}2.8532$) and CNR ($0.391{\pm}0.3025$) in 15 f/s, which were not statistically significant (p>0.05). In the correlation analysis, statistically significant results were obtained among the BMI, air kerma, and DAP; between air kerma and DAP; and between SNR and CNR (p<0.001, p<0.001). In conclusion, there was no significant difference between the entrance surface dose and absorbed dose even when the images were taken by changing the frame from 10 f/s to 15 f/s at the time of the coronary angiography. SNR and CNR increased at 15 f/s than at 10 f/s, but they were not statistically significant. Therefore, this study suggests that the concern of the patient and practitioner regarding image quality degradation, as well as the problem of X-ray exposure caused by imaging at 10 f/s and 15 f/s, may be reduced.

Improved Device Performance Due to AlxGa1-xAs Barrier in Sub-monolayer Quantum Dot Infrared Photodetector

  • Han, Im Sik;Byun, Young-Jin;Lee, Yong Seok;Noh, Sam Kyu;Kang, Sangwoo;Kim, Jong Su;Kim, Jun Oh;Krishna, Sanjay;Ku, Zahyun;Urbas, Augustine;Lee, Sang Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.298-298
    • /
    • 2014
  • Quantum dot infrared photodetectors (QDIPs) based on Stranski-Krastanov (SK) quantum dots (QDs) have been widely explored for improved device performance using various designs of heterostructures. However, one of the biggest limitations of this approach is the "pancake" shape of the dot, with a base of 20-30 nm and a height of 4-6 nm. This limits the 3D confinement in the quantum dot and reduces the ratio of normal incidence absorption to the off-axis absorption. One of the alternative growth modes to the formation of SK QDs is a sub-monolayer (SML) deposition technique, which can achieve a much higher density, smaller size, better uniformity, and has no wetting layer as compared to the SK growth mode. Due to the advantages of SML-QDs, the SML-QDIP design has attractive features such as increased normal incidence absorption, strong in-plane quantum confinement, and narrow spectral wavelength detection as compared with SK-DWELL. In this study, we report on the improved device performance of InAs/InGaAs SML-QDIP with different composition of $Al_xGa1-_xAs$ barrier. Two SML-QDIPs (x=0.07 for sample A and x=0.20 for sample B) are grown with the 4 stacks 0.3 ML InAs. It is investigated that sample A with a confinement-enhanced (CE) $Al_{0.22}Ga_{0.78}As$ barrier had a single peak at $7.8{\mu}m$ at 77 K. However, sample B with an $Al_{0.20}Ga_{0.80}As$ barrier had three peaks at (${\sim}3.5{\mu}m$, ${\sim}5{\mu}m$, ${\sim}7{\mu}m$) due to various quantum confined transitions. The measured peak responsivities (see Fig) are ~0.45 A/W (sample A, at $7.8{\mu}m$, $V_b=-0.4V$ bias) and ~1.3 A/W (sample B, at $7{\mu}m$, $V_b=-1.5V$ bias). At 77 K, sample A and B had a detectivity of $1.2{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-0.4V$ bias) and $5.4{\times}10^{11}cm.Hz^{1/2}/W$ ($V_b=-1.5V$ bias), respectively. It is obvious that the higher $D^*$ of sample B (than sample A) is mainly due to the low dark current and high responsivity.

  • PDF

Clinical Outcome after Treatment with the First-line Drugs in Patients with Persistent Positive Sputum Smear and Negative Sputum Culture Results (지속적인 객담 도말양성 및 배양음성인 폐결핵환자에서 일차항결핵제로 치료종결한 후의 임상성적)

  • Kwon, Eun-Su;Lee, Jong-Youk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.4
    • /
    • pp.325-333
    • /
    • 2001
  • Background : This study aimed to estimate the clinical outcome and identify the characteristics of a group of patients with pulmonary tuberculosis who completed anti-tuberculosis therapy with the First-line drugs in spite of having positive smear results with negative sputum culture results over the previous six months. Method : A retrospective chart review of 21 patients who fulfilled the above criteria between 1995 and 1999 was performed. The laboratory data as well as the clinical data of the patients with positive smear results and negative culture results over a six months period were reviewed. Results : The negative conversion of sputum culture results was achieved within $1.3{\pm}1.2$ months and the negative conversion of the sputum smear results was accomplished during $9.5{\pm}3.3$ months. Chest X-rays at 5 months following the institution of anti-tuberculosis therapy from all patients revealed improvements. Four out of 21 patients(19%) relapsed during the follow up, $15.2{\pm}13.4$ months after administering anti-tuberculosis therapy for $13.3{\pm}3.1$ months. Relapses were confirmed from between 3 months and 4 months after the treatment completion. Only one of the four relapses had no past history of anti-tuberculosis therapy and the others had prior treatment twice (p<0.01). The period of anti-tuberculosis treatment was extended to a mean of $4.6{\pm}2.6$ months in 12 patients. However, prolongation of anti-tuberculosis therapy had no affect on the relapse rate (odds ratio, 95% CI 0.18, 2.15). Conclusion : Prolongation of therapy with the First-line drugs is not necessary for patients with persistently positive smear results over 6 months and negative culture results. A patient who has had prior anti-tuberculosis therapy more than twice should be paid the closest attention.

  • PDF

Oral Cleft Risk Factors in Rural Area of Indonesia(Sintang) (인도네시아 농촌지역의 구순구개열 위험요인 사례조사)

  • Park, Dae-jin;Lim, Young-soo;Oh, Jee-young;Koh, Kwang-Wook;Song, Sung-Eun;Jo, Eun-Joo
    • Journal of agricultural medicine and community health
    • /
    • v.31 no.2
    • /
    • pp.187-208
    • /
    • 2006
  • Objectives: This study was carried out to evaluate the risk factors of Oral cleft and to inspect the living environments of the rural areas of Sintang, Indonesia Methods: During 3 to 9 August 2004, A questionnaire survey was done for the risk factors of oral cleft. Case group was composed of 11 oral cleft patients who admitted Missionary Hospital whose mother's bloods were analyzed for anemia and hyperlipidemia. Control group was composed of 56 reproductive rural women recruited from near rural villages. Also we surveyed 4 rural areas of Indonesia with simple water test kits. $x^2-test$ for significant difference was analysed. Results: Drinking water was statistically significant risk factor(p<0.05) of oral cleft. Other factors had no statistical significancy. The kind of drinking water was river-originated water. In rural villages, water sanitation state, even boiled water, was very poor. Although $NO_2-N$, $NO_3-N$ was negative, E. coli-form microorganisms were strongly positive in most samples. Total food intake amount was not enough, and vitamin supplements were also under the need. Conclusions: Drinking the contaminated river-water around pregnancy was supposed to be one of the risk factors of oral cleft in Indonesia. Further study is needed for nitrate and mercury.

  • PDF

Bioequivalence Of SudoTM Ranitidine Hydrochloride Tablet to CuranTM Tablet (Ranitidine Hydrochloride 150 mg) (큐란 정(염산라니티딘 150 mg)에 대한 수도염산라니티딘정의 생물학적동등성)

  • Lee, Sun-Neo;Ko, Youn-Jung;Kang, Seung-Woo;Yoon, Seo-Hyun;Park, Moo-Sin;Lee, Ye-Ri;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.193-199
    • /
    • 2006
  • A bioequivalence study of $Sudo^{TM}$ Ranitidine HCI tablet (Sudo Pharma. Ind. Co., Ltd.) to $Curan^{TM}$ tablet (Il Dong Pharma. Ind. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty four healthy male Korean volunteers received each medicine at the ranitidine hydrochloride dose of 150 mg in a 2x2 crossover study. There was a one week wash-out period between the doses. Plasma concentrations of ranitidine were monitored by a high-turbulent liquid chromatography (HTLC) for over a period of 12 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found far all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Sudo^{TM}$ Ranitidine $HCl/Curan^{TM}$ were 0.92-1.00 and 0.90-1.03, respectively. These values were within the acceptable bioequivalence intervals of 0.80-1.25. Thus, our study demonstrated the bioequivalence of $Sudo^{TM}$ Ranitidine HCI and $Curan^{TM}$ with respect to the rate and extent of absorption.

Effect of Raw Fish-Based Moist Pellet (MP) and Commercial Red Sea Bream Feed (CF) on Growth and Body Composition of Sunshine Bass (M. saxatilis male X M. chrysops female) Reared at Various Salinity During the Winter Season

  • Cho Sung Hwoan;Lee Jong Kwan
    • Fisheries and Aquatic Sciences
    • /
    • v.5 no.3
    • /
    • pp.229-234
    • /
    • 2002
  • Possibility of raising sunshine bass during the winter season in Korea was investigated. Also, the effect of feed on growth and body composition of sunshine bass was compared at the various salinity. Twenty sunshine bass $(Mean\;weight\;\pm S.D.\: :\;53.9 \pm 0.24 g)$ were stocked into the eighteen circular flow-through tanks. A 2 (feed) $\times$ 3 (salinity) factorial design with triplicate was used for this study. Feed was prepared into the 2 groups: the raw fish-based me>ist pellet (MP) containing $59.5\%$ crude protein and $9.4\%$ crude lipid, and commercial sinking red sea bream feed (CF) containing $49.9\%$ crude protein and $9.4\%$ crude lipid, respectively. And salinity was prepared into the 3 groups: freshwater $(0\%)$, brackishwater $(15\%)$, and seawater $(32\%)$. Fish were fed to satiation twice daily for 6 days a week. Fish were all survived at the end of the 8-week feeding trial. Weight gain (WG) and specific growth rate (SGR) of sunshine bass were significantly (P<0.05) affected by both feed and salinity. WG and SGR of sunshine bass fed the MP were significantly (P<0.05) higher than those of fish fed the CF in the same salinity. Amount of dry feed fed was significantly (P<0.05) affected by both feed and salinity. Feed consumption by sunshine bass fed on the MP was significantly (P<0,05) higher than by fish fed on the CF in the same salinity. Feed efficiency ratio (FER) was significantly (P<0,05) affected by salinity, but not by feed. Protein efficiency ratio (PER) was significantly (P<0.05) affected by both feed and salinity. Moisture and protein content of the whole-body of fish was not significantly (P>0.05) affected by either feed or salinity. However, lipid and ash content of the whole-body of fish was significantly (P<0.05) affected by salinity, but not by feed. In conclusion, the MP was superior to CF for growth of sunshine bass during the winter season in Korea and no mortality occurred. And sunshine bass seemed to grow better in freshwater $(0\%)$ and brac-kishwater $(15\%)$ than seawater $(32\%)$ under these experimental conditions, in terms of improvement in FER and PER in freshwater or brackishwater.

Analysis of the Radiation Patterns of Satellite SAR System with Active-Transponder (능동전파반사기를 이용한 위성 SAR 시스템 방사 패턴 분석)

  • Hwang, Ji-Hwan;Kweon, Soon-Koo;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.10
    • /
    • pp.1204-1211
    • /
    • 2012
  • Measurement and analysis results of the extracted radiation-patterns from the field-experiments which were conducted to acquire the generic technology for calibration and validation of the satellite SAR system(Synthetic Aperture Radar) are presented in this study. Prototype of active transponder is adjustable within maximum 63.1 dBsm of RCS (Radar Cross Section) and includes the receiving-function with external receiver. To increase an accuracy of these field experiments, we repetitively measured satellite SAR systems of the same operating mode(i.e., COSMO-SkyMed No. 2 & 3, hh-pol., strip-map himage mode, 3 m resolution). Then, the reliability of experimental results was cross-checked through analysis of the RCS of active transponder on SAR image. The property of azimuth radiation patterns of satellite SAR system extracted from them has $0.352^{\circ}$ of HPBW(half-power beamwidth), $0.691^{\circ}$ of FNBW(first-null beamwidth), and 11.17 dB of PSLR(peak to side lobe ratio), respectively.

Metastatic Axillary Lymph Node Ratio (LNR) is Prognostically Superior to pN Staging in Patients with Breast Cancer -- Results for 804 Chinese Patients from a Single Institution

  • Xiao, Xiang-Sheng;Tang, Hai-Lin;Xie, Xin-Hua;Li, Lai-Sheng;Kong, Ya-Nan;Wu, Min-Qing;Yang, Lu;Gao, Jie;Wei, Wei-Dong;Xie, Xiaoming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5219-5223
    • /
    • 2013
  • The number of axillary lymph nodes involved and retrieved are important prognostic factors in breast cancer. The purpose of our study was to investigate whether the lymph node ratio (LNR) is a better prognostic factor in predicting disease-free survival (DFS) for breast cancer patients as compared with pN staging. The analysis was based on 804 breast cancer patients who had underwent axillary lymph node dissection between 1999 and 2008 in Sun Yat-Sen University Cancer Center. Optimal cutoff points of LNR were calculated using X-tile software and validated by bootstrapping. Patients were then divided into three groups (low-, intermediate-, and high-risk) according to the cutoff points. Predicting risk factors for relapse were performed according to Cox proportional hazards analysis. DFS was estimated using the Kaplan-Meier method and compared by the log-rank test. The 5-year DFS rate decreased significantly with increasing LNRs and pN. Univariate analysis found that the pT, pN, LNR, molecule type, HER2, pTNM stage and radiotherapy well classified patients with significantly different prognosis. By multivariate analysis, only LNR classification was retained as an independent prognostic factor. Furthermore, there was a significant prognostic difference among different LNR categories for pN2 category, but no apparent prognostic difference was seen between different pN categories in any LNR category. Therefore, LNR rather than pN staging is preferable in predicting DFS in node positive breast cancer patients, and routine clinical decision-making should take the LNR into consideration.

The Ratio of Descending Aortic Enhancement to Main Pulmonary Artery Enhancement Measured on Pulmonary CT Angiography as a Finding to Predict Poor Outcome in Patients with Massive or Submassive Pulmonary Embolism

  • Park, Chi-Young;Yoo, Seung-Min;Rho, Ji-Young;Ji, Young-Geon;Lee, Hwa-Yeon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.72 no.4
    • /
    • pp.352-359
    • /
    • 2012
  • Background: The purpose of this study was to evaluate whether measuring the ratio of descending aortic enhancement (DAE) to main pulmonary artery enhancement (MPAE) on pulmonary computed tomography angiography (PCTA) can predict poor outcome in patients with acute massive or submassive pulmonary embolism (PE). Methods: We retrospectively, reviewed computed tomgraphy findings and charts of 37 patients with acute PE and right ventricular dysfunction. We divided the enrolled patients into 3 groups; group Ia (n=8), comprised of patients with major adverse event (MAE); group Ib (n=5), consisted of those with PE-related MAE; and group II (n=29), those without MAE. We analyzed the right ventricular diameter (RVD)/left ventricular diameter (LVD) and DAE/MPAE on PCTA. Results: For observer 1, RVD/LVD in group Ia ($1.9{\pm}0.36$ vs. $1.44{\pm}0.38$, p=0.009) and group Ib ($1.87{\pm}0.37$ vs. $1.44{\pm}0.38$, p=0.044) were significantly higher than that of group II. For observer 2, RVD/LVD in group Ia ($1.71{\pm}0.18$ vs. $1.41{\pm}0.47$, p=0.027) was significantly greater than that of group II, but RVD/LVD of group Ib was not ($1.68{\pm}0.2$ vs. $1.41{\pm}0.47$, p=0.093). For both observers, there was a significant difference of DAE/MPAE between group Ib and group II ($0.32{\pm}0.15$ vs. $0.64{\pm}0.24$, p=0.005; $0.34{\pm}0.16$ vs. $0.64{\pm}0.22$, p=0.004), but no significant difference of DAE/MPAE between group Ia and group II ($0.51{\pm}0.3$ vs. $0.64{\pm}0.24$, p=0.268; $0.53{\pm}0.29$ vs. $0.64{\pm}0.22$, p=0.302). Intra-class correlation coefficient (ICC) for the measurement of DAE/MPAE (ICC=0.97) was higher than that of RVD/LVD (ICC=0.74). Conclusion: DAE/MPAE measured on PCTA may predict PE-related poor outcomes in patients with massive or submassive PE with an excellent inter-observer agreement.