• Title/Summary/Keyword: $NO_2/NO_x$ ratio

Search Result 549, Processing Time 0.034 seconds

Photocatalysis of TiO2/WO3 Composites Synthesized by Ball Milling (볼밀을 이용한 TiO2/WO3 복합체 제조 및 광촉매 특성)

  • Yu, Su-Yeol;Nam, Chunghee
    • Journal of Powder Materials
    • /
    • v.25 no.4
    • /
    • pp.316-321
    • /
    • 2018
  • Composites of P25 $TiO_2$ and hexagonal $WO_3$ nanorods are synthesized through ball-milling in order to study photocatalytic properties. Various composites of $TiO_2/WO_3$ are prepared by controlling the weight percentages (wt%) of $WO_3$, in the range of 1-30 wt%, and milling time to investigate the effects of the composition ratio on the photocatalytic properties. Scanning electron microscopy, x-ray diffraction, and transmission electron microscopy are performed to characterize the structure, shape and size of the synthesized composites of $TiO_2/WO_3$. Methylene blue is used as a test dye to analyze the photocatalytic properties of the synthesized composite material. The photocatalytic activity shows that the decomposition efficiency of the dye due to the photocatalytic effect is the highest in the $TiO_2/WO_3$ (3 wt%) composite, and the catalytic efficiency decreases sharply when the amount of $WO_3$ is further increased. As the amount of $WO_3$ added increases, dye-removal by adsorption occurs during centrifugation, instead of the decomposition of dyes by photocatalysts. Finally, $TiO_2/WO_3$ (3 wt%) composites are synthesized with various milling times. Experimental results show that the milling time has the best catalytic efficiency at 30 min, after which it gradually decreases. There is no significant change after 1 hour.

Image quality-based dose optimization in pediatric cone-beam computed tomography: A pilot methodological study

  • Hak-Sun Kim;Yoon Joo Choi;Kug Jin Jeon;Sang-Sun Han;Chena Lee
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.264-270
    • /
    • 2024
  • Purpose: This study aimed to propose a methodological approach for reducing the radiation dose in pediatric cone-beam computed tomography (CBCT), focusing exclusively on balancing image quality with dose optimization. Materials and Methods: The dose-area product (DAP) for exposure was reduced using copper-plate attenuation of an X-ray source. The thickness of copper (Cu) was increased from 0 to 2.2 mm, and 10 different DAP levels were used. The QUART DVT_AP phantom and pediatric radiologic dentiform were scanned under the respective DAP levels. The contrast-to-noise ratio (CNR), image homogeneity, and modulation transfer function (MTF) were analyzed using the QUART DVT_AP phantom. An expert evaluation (overall image grade, appropriateness of field of view, artifacts, noise, and resolution) was conducted using pediatric dentiform images. The critical DAP level was determined based on phantom and dentiform analysis results. Results: CNR and image homogeneity decreased as the DAP was reduced; however, there was an inflection point of image homogeneity at Cu 1.6 mm (DAP=138.00 mGy·cm2), where the value started increasing. The MTF showed constant values as the DAP decreased. The expert evaluation of overall image grades showed "no diagnostic value" for dentiform images with Cu 1.9-2.2 mm (DAP=78.00-103.33 mGy·cm2). The images with Cu 0-1.6 mm (DAP=138.00-1697.67mGy·cm2) had a "good," "moderate," or "poor but interpretable" grade. Conclusion: Reducing DAP beyond a 1.6-mm Cu thickness degraded CBCT image quality. Image homogeneity and clinical image grades indicated crucial decision points for DAP reduction in pediatric CBCT scans.

Dry reforming of Propane to Syngas over Ni-CeO2/γ-Al2O3 Catalysts in a Packed-bed Plasma Reactor (충전층 플라즈마 반응기에서 Ni-CeO2/γ-Al2O3 촉매를 이용한 프로페인-합성 가스 건식 개질)

  • Sultana, Lamia;Rahman, Md. Shahinur;Sudhakaran, M.S.P.;Hossain, Md. Mokter;Mok, Young Sun
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.81-90
    • /
    • 2019
  • A dielectric barrier discharge (DBD) plasma reactor packed with $Ni-CeO_2/{\gamma}-Al_2O_3$ catalyst was used for the dry ($CO_2$) reforming of propane (DRP) to improve the production of syngas (a mixture of $H_2$ and CO) and the catalyst stability. The plasma-catalytic DRP was carried out with either thermally or plasma-reduced $Ni-CeO_2/{\gamma}-Al_2O_3$ catalyst at a $C_3H_8/CO_2$ ratio of 1/3 and a total feed gas flow rate of $300mL\;min^{-1}$. The catalytic activities associated with the DRP were evaluated in the range of $500{\sim}600^{\circ}C$. Following the calcination in ambient air, the ${\gamma}-Al_2O_3$ impregnated with the precursor solution ($Ni(NO_3)_2$ and $Ce(NO_3)_2$) was subjected to reduction in an $H_2/Ar$ atmosphere to prepare $Ni-CeO_2/{\gamma}-Al_2O_3$ catalyst. The characteristics of the catalysts were examined using X-ray diffraction (XRD), transmission electron microscopy (TEM), field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectrometry (EDS), temperature programmed reduction ($H_2-TPR$), temperature programmed desorption ($H_2-TPD$, $CO_2-TPD$), temperature programmed oxidation (TPO), and Raman spectroscopy. The investigation revealed that the plasma-reduced $Ni-CeO_2/{\gamma}-Al_2O_3$ catalyst exhibited superior catalytic activity for the production of syngas, compared to the thermally reduced catalyst. Besides, the plasma-reduced $Ni-CeO_2/{\gamma}-Al_2O_3$ catalyst was found to show long-term catalytic stability with respect to coke resistance that is main concern regarding the DRP process.

Conventional Anchorage Reinforcement vs. Orthodontic Mini-implant: Comparison of Posterior Anchorage Loss During the En Masse Retraction of the Upper Anterior Teeth

  • Baek, Seung-Hak;Kim, Young-Ho
    • Journal of Korean Dental Science
    • /
    • v.3 no.1
    • /
    • pp.5-10
    • /
    • 2010
  • This study sought to compare the amounts of posterior anchorage loss during the en masse retraction of the upper anterior teeth between orthodontic mini-implant (OMI) and conventional anchorage reinforcement (CAR) such as headgear and/or transpalatal arch. The subjects were 52 adult female patients treated with sliding mechanics (MBT brackets, .022" slot, .019X.025" stainless steel wire, 3M-Unitek, Monrovia, CA, USA). They were allocated into Group 1 (N=24, Class I malocclusion (CI), upper and lower first premolar (UP1LP1) extraction, and CAR), Group 2 (N=15, Cl, UP1LP1 extraction and OMI), and Group 3 (N=13, Class II division 1 malocclusion, upper first and lower second premolar extraction, and OMI). Lateral cephalograms were taken before (T0) and after treatment (T1). A total of 11 anchorage variables were measured. Analysis of variance was used for statistical analysis. There was no significant difference in treatment duration and anchorage variables at T0 among the three groups. Groups 2 and 3 showed significantly larger retraction of the upper incisor edge (U1E-sag, 9.3mm:7.3mm, P<.05) and less posterior anchorage loss (U6M-sag, 0.7~0.9mm:2mm, P<.05; U6A-sag, 0.5mm:2mm, P<.01) than Group 1. The ratio of retraction amount of the upper incisor edge per 1 of anchorage loss in the upper molar made for the significant difference between Groups 1 and 2 (4.6mm:7.0mm, P<.05). Group 3 showed a relatively distal inclination of the upper molar (P<.05) and the intrusion of the upper incisor and first molar (U1E-ver, P<.05; U6F-ver, P<.05) compared to Groups 1 and 2. Although OMI could not shorten the treatment duration, it could provide better maximum posterior anchorage than CAR.

  • PDF

An Experimental Study on the Performance and Emission Characteristics with Hydrogen Enrichment in a CNG Engine (수소첨가 CNG기관의 성능 및 배출가스 특성에 관한 실험적 연구)

  • Ryu, Kyuhyun;Kim, Ingu
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.2
    • /
    • pp.164-169
    • /
    • 2015
  • Recent research has focused on alternative fuel to improve engine performance and to comply with emission regulation. Finding an alternative fuel and reducing environment pollution are the main goals for future internal combustion engines. The purpose of this study is to obtain low-emission and high-efficiency by hydrogen enriched CNG fuel in SI engine and is to clarify the effects of hydrogen enrichment in CNG fuelled engine on exhaust emission and performance. An experimental study was carried out to obtain fundamental data for performance and emission characteristics of hydrogen enrichment in SI engine. The experiment was conducted at 2500 rpm, bmep 2 bar, 4 bar conditions while CNG fuel was mixed with 10, 20 and 30% hydrogen blends. From the experimental results, combustion duration was shortened due to rapid flame propagation velocity of hydrogen and these were attributed to the burning velocity increasing exponentially with increasing hydrogen blending ratio. Hydrogen has much wider flammable limit than methane, gasoline and the minimum ignition energy is about an order of magnitude lower than for other combustion. By adding hydrogen, $CO_2$ and HC were reduced. However, $NO_X$ was increased dut to high rate of heat release for hydrogen substitutions.

High Performance $2{\times}4$ S-SEED Array with Extremely Shallow Quantum Well and Asymmetric Fabry-Peort Cavity Structure (저장벽 양자우물고조와 비대칠 패브리-페로 공명기 구조에 의한 고성능 $2{\times}4$ S-SEED Array 구현)

  • 권오균;최영완;김광준;이일항;이상훈;원용협;유형모
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.144-151
    • /
    • 1994
  • We designed and fabricated a $2{\times}4$ symmetric self electro-optic effect device array using GaAs/ AIo.04 G$\DeltaR$), and optical bistability loop width ($\Delta$). The average values of the elements of the $2{\times}4$ S-SEED array were CR~13.1, R~24%, and $\Delta$~91%. It was found that the AFP cavity structure enhances the self-biased optical bistability in ESQW-SEED under no external bias. That is due to the decreased intrisic region thickness in AFP-SEED structures, and which increases the built-in electric fields. The zero-biased S-SEED showed CR of ~4.7, R~9%, and $\Delta$~22%.X>~22%.

  • PDF

Metallurgical Analysis of Forged Iron Axe Excavated from the Wood-framed Tomb at the Hwangseongdong, Gyeongju, Korea (경주 황성동 목곽묘에서 출토된 단조 철부의 금속학적 특성 분석)

  • Lee, Chan-Hee;Lee, Myeong-Seong;Kim, Jeong-Hun;Yi, Ki-Wook
    • 한국문화재보존과학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.33-42
    • /
    • 2004
  • The forged iron axe found in the No. 2 wood-framed tomb (the middle 3rd century) of Hwangseongdong, Gyeongju is rectangular on the plane level. It shows an obtuse angle in the edge part, while the joint part has the both sides folded up and shows the traces of wood. Under the reflected light, the Iron axe shines in metal luster, which is bright light gray or light creamy colors. The result of x-ray diffraction analysis shows that the axe consists of magnetite and geothite, which can explain why the composition and structure of the original ore has been kept intact. The microtexture of the axe has the irregular network of ferrite and pearlite, and tile cementite of tiny amount in the ferrite background. The overall treatment of the texture seems to be thermal with a high ratio of carbon. There are fine-grained magnetite, wolframite, quartz, calcite, mica, hornblende and pyroxene inside the axe. Those must be the impurities that they failed to remove in the refining process. The normal ferrite is composed of pure iron whose $Fe_2O_3$ proportion is from 99.16 to $99.84\;wt.\%$. Other than them, the ferrite parts usually contain $Al_2O_3\;and\;SiO_2$. The irregular network of pearlite also contains Impurities including $Al_2O_3\;and\;SiO_2$ and shows highly diverse patterns of carbon content. It's because the axe was carburized after the material was made to resemble pure iron. The decarbonization work didn't go well along the process marks. It's estimated that the original ore was bloom produced in low-temperature reduction and formed around in $727^{\circ}C$, which is eutetic temperature.

  • PDF

Diagnostic Value of ADA Multiplied by Lymphocyte to Neutrophil Ratio in Tuberculous Pleurisy (결핵성 흉막염에서 ADA 활성도와 림프구/중성구 비의 곱의 진단적 유용성)

  • Jeon, Eun Ju;Kwak, Hee Won;Song, Ju Han;Lee, Young Woo;Jeong, Jae Woo;Choi, Jae Cheol;Shin, Jong Wook;Kim, Jae Yeol;Park, In Won;Choi, Byoung Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.1
    • /
    • pp.17-23
    • /
    • 2007
  • Background: Many diagnostic approaches for defining the definitive cause of pleurisy should be included due to the large variety of diseases resulting in pleural effusion. Although ADA is a useful diagnostic tool for making a differential diagnosis of pleural effusion, particularly for tuberculous pleural effusion, a definitive diagnostic cut-off value remains problematic in Korea. It was hypothesized that ADA multiplied by the Lymphocyte/Neutrophil ratio(L/N ratio) might be more powerful for making a differential diagnosis of pleural effusion. Methods: One hundred and ninety patients, who underwent thoracentesis and treatment in Chung-Ang University Hospital from January, 2005 through to February 2006, were evaluated. The clinical characteristics, radiologic data and the examination of the pleural effusion were analyzed retrospectively. Results: 1. Among the 190 patients, 59 patients (31.1%) were diagnosed with tuberculous pleurisy, 45 patients(23.7%) with parapneumonic effusion, 42 patients(22.1%) with malignant effusions, 36 patients(18.9%) with transudate, and 8 patients(4.2%) with empyema. One hundred and twenty one patients were found to have an ADA activity of 1 to 39 IU/L(63.7%). Twenty-nine were found to have an ADA activity of 40 to 75 IU/L(15.3%) and 40 were found to have an ADA activity of 75 IU/L or greater(21.0%). 2. Among the patients with tuberculous pleurisy, 5(8%), 18(30%) and 36 patients(60%) had an ADA activity ranging from 1 to 39 IU/L, 40 to 75 IU/L, and 75 IU/L or greater, respectively. In those with an ADA activitiy 40 to 75 IU/L, 18 patients(62%) had tuberculous pleurisy, 9(31%) had parapneumonic effusion and empyema, and 1(3.4%) had a malignant effusion. 3. In those with an ADA activity of 40 to 75 IU/L, there was no significant difference between tuberculous pleurisy and non-tuberculous pleural effusion(tuberculous pleurisy : 61.3 ${\pm}$ 9.2 IU/L, non-tuberculous pleural effusion : 53.3${\pm}$10.5 IU/L). 4. The mean L/N ratio of those with tuberculous pleurisy was 39.1 ${\pm}$ 44.6, which was significantly higher than nontuberculous pleural effusion patients (p<0.05). The mean ADA x L/N ratio of the tuberculous pleurisy patients was 2,445.7 ${\pm}$ 2,818.5, which was significantly higher than the non-tuberculous pleural effusion patients (level p<0.05). 5. ROC analysis showed that the ADA x L/N ratio had a higher diagnostic value than the ADA alone in the group with an ADA between 40-75 IU/L. Conclusion: The ADA multiplied by the lymphocyte-to-neutrophil ratio might provide a more definitive diagnosis of tuberculous pleurisy.

Effect of Carbon Couch Side Rail and Vac-lok In case of Lung RPO irradiation (Lung RPO 선량전달시, Carbon Couch Side Rail과 Vac-lok이 미치는 영향)

  • Kim, Seok Min;Gwak, Geun Tak;Lee, Seung Hun;Kim, Jung Soo;Kwon, Hyoung Cheol;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.27-34
    • /
    • 2018
  • Purpose : To evaluate the effect of carbon couch side rail and vacuum immobilization device in case of lung RPO irradiation. Materials and Methods : The 10, 20, 30 mm thickness of vac-lok's right side were obtained. To measure of doses, glass dosimeters were used and measured reference point is left lung center at the phantom. A, B, C, and D points are left, right, down, and up directions based on the center point. In the state of Side-Rail-Out, place the without vac-lok, with the thickness of 10, 20, and 30 mm vac-lok. After the glass dosimeters was inserted in center, A, B, C, and D points, 100 MU of 6 MV X-ray were irradiated to the referenced center point in the condition of $10{\times}10cm^2$ field size, SAD 100 cm, gantry angle 225, 300 MU/min dose rate. Five measurements were made for each point. In the state of Side-Rail-In, five measurement were made for each point under the same conditions. The average is measured on each of the five Side-Rail-Out and Side-Rail-In measurements. Results : In the presence of side rail, the dose reduction ratio was -11.8 %, -12.3 %, -4.1 %, -12.3 %, -7.3 % for each A, B, C, and D points. In the state of Side-Rail-Out, the dose reduction ratio for the using 10 mm thickness of vac-lok was -0.9 % than without vac-lok. The dose reduction ratio for the using 20 mm thickness of vac-lok was -2.0 %, for the using 30 mm thickness of the vac-lok was -3.0 % than without vac-lok. In the state of Side-Rail-In, the dose reduction ratio for the using 10 mm thickness of vac-lok was -1.0 % than without vac-lok. The dose reduction ratio for the using 20 mm vac-lok was -2.1 %, for the using 30 mm vac-lok was -3.0 % than without vac-lok. Based on the value of no vac-lok dose in the Side-Rail-In state, The dose reduction ratios for the using 10 mm, 20 mm and 30 mm thickness of vac-loks In the Side-Rail-Out that the center point were -12.7 %, -13.7 %, -14.2 % and -12.8 %, -13.8 %, -14.5 % respectively at point A. The dose reduction ratios for the same conditions to the B point were -4.9 %, -6.1 %, -7.1 % and -13.4 %, -14.4 %, -15.5 % respectively at point C. The dose reduction ratios for the same conditions to the D point were -8.4 %, -9.0 %, -10.4 % respectively. Conclusion : The attenuation was caused by presence of side rails and thickness of vac-lok. Pay attention to these attenuation factors, making it a more effective radiation therapy.

  • PDF

Hyperfractionation Radiation Therapy in Advanced Head and Neck Cancer (진행된 두경부암에서 다분할 방사선치료)

  • Kim, Jin-Hee;Ye, Ji-Won
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.112-117
    • /
    • 2003
  • Purpose: The effects of hypefractionation radiation therapy, such as the failure pattern and survival, on the treatment results in advanced stage head and neck cancer were studied. Materials and Methods: Between September 1990 and October 1998, 24 patients with advanced stage (III, IV) head and neck cancers, were treated using hyperfractionation radiation therapy in the Department of Radiation Oncology at the Keimyung University Dongsan Medical Center. The male to female ratio was 7 : 1, and the age range from 38 to 71 years with the median of 56 years. With regard to the TNM stage, 11 patients were stage III and 13 were stage IV. The sites of primary cancer were the nasopharynx in six, the hypopharynx in 6, the larynx in five, the oropharynx in three, the maxillary sinus in three, and the oral cavity in one patient. The radiotherapy was delivered by 6 MV X-ray, with a fraction size of 1.2 Gy at two fractions a day, with at least 6 hours inter-fractional interval. The mean total radiation doses was 72 Gy, (ranging from 64.4 to 75.8 Gy). Follow-up periods ranged between 3 and 136 months, with the median of 52 months. Results: The overall survival rates at 3 and 5 years in all patients were 66.7$\%$, and 52.4$\%$. The disease-free survival rates at 3 and S years (3YDFS, 5YDFS) in all patients were 66.7$\%$ and 47.6$\%$. The 3YDFS and 5YDFS in stage III patients were 81.8$\%$ and 63.6$\%$, and those in stage IV patients were 53.8$\%$ and 32.3$\%$. Ten patients were alive with no local nor distant failures at the time of analyses. Six patients (25$\%$) died due to distant metastasis and 12.5$\%$ died due to local failure. Distant metastasis was the major cause of failure, but 2 patients died due to unknown failures and 3 of other diseases. The distant metastasis sites were the lung (3 patients), the bone (1 patient), and the liver (2 patients). One patient died of second esophageal cancer. There were no severe late complications, with the exception of 1 osteo-radionecrosis of the mandible 58 months after treatment. Conclusion: Although this study was peformed on small patients group, we considered hypefractionated radiation therapy for the treatment of advanced stage head and neck cancer might improve the disease free survival and decrease the local failure with no increase in late complications despite of the slight Increase in acute complications.