• Title/Summary/Keyword: $NO_2$ Sensor

Search Result 604, Processing Time 0.026 seconds

A study on the $NO_2$ Gas Detection Characteristics of Octa(2-ethylhexyloxy)Copper-Phthalocyanine Langmuir-Blodgett films (Octa(2-ethylhexyloxy)Copper-Phthalocyanine LB막의 $NO_2$ 가스 탐지 특성에 관한 연구)

  • 임준석;김영관;김정수
    • Electrical & Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.419-424
    • /
    • 1997
  • It is well known that the metallo-phthalocyanines (MPcs) are sensitive to toxic gaseous molecules such as NO$_2$ as well as are chemically and thermally stable. Therefore, lots of MPcs have been studied as the potential chemical sensor for NO$_2$gas using quartz crystal microbalance(QCM) or electrical conductivity. In this study, thin films of octa(2-ethylhexyloxy)copper-phthalocyanine were prepared by Langmuir-Blodgett method and characterized by using UV-VIS absorption spectroscopy and ellipsometry. Optimal transfer condition of LB films was investigated and preliminary results of current-voltage(I-V) characteristics of these films exposed to NO$_2$gas as a function of film thickness, temperature and concentration were discussed.

  • PDF

A Study on the Loss and Damage Ratio of Railroad Tunnel Maintenance Monitoring Sensor (철도터널 유지관리 계측센서의 손망실율 연구)

  • Woo, Jong-Tae
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.262-270
    • /
    • 2018
  • Purpose: This paper investigates and analyzes the loss and damage ratio of maintenance monitoring sensor in metropolitan and high speed railroad tunnel in Korea and abroad. Method: After 5~6 years from the installation, the maintenance monitoring sensor on metropolitan transit tunnels showed the loss and damage ratio from 14.2% to 14.8% in Seoul metro line no. 5, 6, 7, 9, and 13.9% in UK channel tunnel. Based on the result, 15% is thought to be a proper set for the elapsed years, which is 5 years from the installation. Results: The maintenance monitoring sensor on high speed railroad tunnels showed the loss and damage ratio of 60.9% in Ho-Nam high speed railroad on 1 stage after 3 ~ 5 years from the installation, which was approximately 4 times as high as that of Seoul metro line no. 5, 6, 7, 9. Conclusion: Kyung-Bu high speed railroad on 2 stage, after 8~10 years from the installation, showed the loss and damage ratio of 66.8%. Based on the result, it can be inferred that the loss and damage ratio increases drastically after 5~10 years from the installation. Therefore, it is necessary to study on the loss and damage ratio of long term elapsed years, especially more than 10 years from the installation.

SAW Gas Sensor using WO$_3$Thin Film (WO$_3$박막을 이용한 SAW 가스 센서)

  • 정영우;허두오;이해민;안형근;한득영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.11a
    • /
    • pp.187-189
    • /
    • 1995
  • A Surface Acoustic Wave Gas sensor for NO, CO, H$_2$gas detection was designed fabricated, and tested. A delay line device was designed to composite a single mode SAW oscillator which enables to measure a SAW velocity. To reduce the effect of temperature and humidity, dual delay line oscillator circuit was used. And final output was measured by digital frequency counter. NO, CO, H$_2$gas were detected by WO$_3$thin film deposited on the path of the Delay Line.

  • PDF

A study on the $NO_2$ Gas Detection Characteristics of Octa(2-ethylhexyloxy)copper-phthalocyanine LB Films (Octa(2-ethylhexyloxy)copper-phthalocyanine LB막의 $NO_2$ 가스 탐지 특성에 관한연구)

  • Yim, Jun-Seok;Kim, Young-Kwan;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1716-1718
    • /
    • 1996
  • It is well known that the metallophthalocyanine (MPcs) are sensitive to toxic gaseous molecules such as $NO_2$ and also chemically and thermally stable. Therefore, lots of MPcs are studied for the potential chemical sensor for $NO_2$ gas using quartz crystal microbalance(QCM) or electrical conductivity. In this study, thin films of octa(2-ethylhexyloxy) copper-phthalocyanine were prepared by Langmuir-Blodgett method and characterized by using UV-VIS spectrascopy and ellipsometry. Transfer condition, film characterization, and preliminary results of current-voltage(I-V) characteristics of these films exposed to $NO_2$ gas as a function of film thickness will be discussed.

  • PDF

A study on the NO$_2$ Gas Detection Characteristics of Octa(2-ethylhexyloxy)copper-phthalocyanine LB films (Octa(2-ethylhexyloxy)copper-phnthalocyanine LB막의 NO$_2$ 가스 탐지 특성에 관한 연구)

  • 임준석;김영관;김정수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.05a
    • /
    • pp.162-165
    • /
    • 1996
  • It is well shown that the metallophthalocyanine (MPcs) are sensitive to tonic gaseous molecules such as NO$_2$ and also chemically and thermally stable. Therefore, lots of MPcs are studied for the potential chemical sensor for NO$_2$ gas using quartz crystal microbalance(QCM) or electrical conductivity. In this study, thin films of octa(2-ethylhexyloxy) copper-phthalocyaninc ware prepared by Langmuir-Blodgett method and characterized by using UV-VIS spectrascopy and cllipsometry. Transfer condition, film characterization, and preliminary results of current-voltage(I-V) characteristics of these films exposed to NO$_2$ gas as a function of film thickness will be discusscd.

  • PDF

A study on the NO$_2$Gas Detection chracteristics of the Octa (2-ethylhexyloxy) copper-phthalocyanine LB film (Octa (2-ethyls expel oxy) copper-phthalocyanine LB막의 NO$_2$가스 탐지 특성에 관한 연구)

  • 임준석;김영관;김정수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.121-124
    • /
    • 1996
  • It is well known that the metallo- phthalocyanine (MPcs) are sensitive to toxic gaseous molecules such as NO$_2$and also chemically and thermally stable. Therefore, lots of MPcs have been studied for the potential chemical sensor for NO$_2$gas using quartz crystal microbalance(QCM) or electrical conductivity. In this study, thin films of octa(2-ethylhexyloxy) copper-phthalocyanine were prepared by Langmuir -Blodgett method and characterized by using UV-VIS spectroscopy and ellipsometry. Transfer condition, and characterization of LB films were investigated and preliminary results of current-voltage(I-V) characteristics of these films exposed to NO$_2$gas as a function of film thickness, temperature and temperature were discussed.

  • PDF

A Study on the characteristics of degradation sensor for insulation oil (절연유(絶緣油) 열화(劣化)센서 특성(特性) 연구(硏究))

  • Chon, Y.K.;Sun, J.H.;Kang, D.S.;Joo, B.S.;Yoon, J.Y.;Chung, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1371-1374
    • /
    • 1995
  • It is well known that the degradation of transformer oil conseqently lead to the failure of transformer. This paper discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor is composed of base ring, electrodes and porous ceramic, passed through the transformer oil and checks the transformer oil condition through sensor's leakage current. So it is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts the characteristics of V-T-I and DC 2 KV and other examinations were performed. It is verified that ionized transformer oil caused by the expansion of temperature increases in the leakage current of porous ceramic sensor. It is certification that the leakage current of other parts of porous ceramic is very small(about 2%) compared with the porous ceramic body and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

CCD Image Sensor with Variable Reset Operation

  • Park, Sang-Sik;Uh, Hyung-Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 2003
  • The reset operation of a CCD image sensor was improved using charge trapping of a MOS structure to realize a loe voltage driving. A DC bias generating circuit was added to the reset structure which sets reference voltage and holds the signal charge to be detected. The generated DC bias is added to the reset pulse to give an optimized voltage margin to the reset operation, and is controlled by adjustment of the threshold voltage of a MOS transistor in the circuit. By the pulse-type stress voltage applied to the gate, the electrons and holes were injected to the gate dielectrics, and the threshold voltage could be adjusted ranging from 0.2V to 5.5V, which is suitable for controlling the incomplete reset operation due to the process variation. The charges trapped in the silicon nitride lead to the positive and negative shift of the threshold voltage, and this phenomenon is explained by Poole-Frenkel conduction and Fowler-Nordheim conduction. A CCD image sensor with $492(H){\;}{\times}{\;}510(V)$ pixels adopting this structure showed complete reset operation with the driving voltage of 3.0V. The resolution chart taken with the image sensor shows no image flow to the illumination of 30 lux, even in the driving voltage of 3.0V.

A study on the characteristics of degradation sensor for transformer insulation oil (변압기(變壓器) 절연유(絶緣油) 열화(劣化)센서의 특성연구(特性硏究))

  • Chon, Y.K.;Sun, J.H.;Kang, D.S.;Kim, M.D.;Kweon, D.J.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1765-1768
    • /
    • 1996
  • It is well known that the degradation transformer oil is mainly effected to the failure of transformer. In this paper it is discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor composed with base ring, electrodes and porous ceramic passed through the transformer oil and checked the transformer oil condition with sensor's leakage current. It is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts it is examined the characteristics of V-T-I and DC 2 KV and other examinations. It is verified that ionized transformer caused by the expansion of oil temperature increase in the leakage current of porous ceramic sensor. It is certificated that the leakage current of other parts of porous ceramic is very small (about 2 %) than the porous ceramic and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

Real-Time Visualization Techniques for Sensor Array Patterns Using PCA and Sammon Mapping Analysis (PCA와 Sammon Mapping 분석을 통한 센서 어레이 패턴들의 실시간 가시화 방법)

  • Byun, Hyung-Gi;Choi, Jang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.99-104
    • /
    • 2014
  • Sensor arrays based on chemical sensors produce multidimensional patterns of data that may be used discriminate between different chemicals. For the human observer, visualization of multidimensional data is difficult, since the eye and brain process visual information in two or three dimensions. To devise a simple means of data inspection from the response of sensor arrays, PCA (Principal Component Analysis) or Sammon's nonlinear mapping technique can be applied. The PCA, which is a well-known statistical method and widely used in data analysis, has disadvantages including data distortion and the axes for plotting the dimensionally reduced data have no physical meaning in terms of how different one cluster is from another. In this paper, we have investigated two techniques and proposed a combination technique of PCA and nonlinear Sammom mapping for visualization of multidimensional patterns to two dimensions using data sets from odor sensing system. We conclude the combination technique has shown more advantages comparing with the PCA and Sammon nonlinear technique individually.