• Title/Summary/Keyword: $Molloplast-B^{(R)}$

Search Result 5, Processing Time 0.014 seconds

A STUDY ON THE EFFECT OF THERMOCYCLING TO THE PHYSICAL PROPERTIES OF DENTURE LINERS (열 순환에 따른 의치이장채의 물리적 성질의 변화에 관한 연구)

  • Lee Dong-Su;Lim Heon-Song;Lim Ju-Hwan;Cho In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.5
    • /
    • pp.556-575
    • /
    • 2001
  • For the improvement of denture fitness of changed residual ridge, denture liner can be used. Denture liner should be very stable physically in various environments of the mouth as well as be bonded strongly with denture resin. In this study. the specimens bonded with four kinds of soft denture liner and three kinds of hard denture liner were used to test the physical properties of the liners. All experimental groups were stored in $37{\pm}1^{\circ}C$ distilled water for 24hours, followed by thermocycling between $15^{\circ}C$ and $45^{\circ}C$ with 15 second dwell time. 1000, 2000, 3000 cycles of thermocycling were excuted and physical properties were measured by Instron Universal Testing Machine. The obtained results were as follows : 1. In tensile bond test of sea liners, it was shown that both of $Molloplast-B^{(R)}$ specimens before and after thermocycling had the highest tensile strength, and in case of hard liners, Dura-Liner $II^{(R)}$ specimen had the highest tensile strength before and after thermocycling. Depending on thermocycling, $Soft-Relining^{(R)}$, $Denture-Relining^{(R)}$, $Molloplast-B^{(R)}$, $Coe-Soft^{(R)}$ and $Kooliner^{(R)}$ specimen showed significant difference(p<0.05). 2. In strain test of soft liners, it was shown that $Molloplast-B^{(R)}$ specimen before thermocycling and the $Coe-Soft^{(R)}$ after thermocycling showed highest results, and in case of hard liners, the Dura-Liner $II^{(R)}$ specimen before and after thermocycling had the highest result. Depending on thormocycling, $Denture-Relining^{(R)}$, $Molloplast-B^{(R)}$ and Dura-Liner $II^{(R)}$ specimen showed significant difference(p<0.05). 3. In maximum distance test of soft liners. the $Molloplast-B^{(R)}$ specimen before thermocycling and the $Coe-Soft^{(R)}$ after thermocycling showed highest results. and in case of hard liners, the Dura-Liner $II^{(R)}$ specimen before and after thermocycling showed highest result. Depending on thermocycling, $Denture-Relining^{(R)}$, $Molloplast-B^{(R)}$ specimens showed significant difference(p<0.05). 4. In elasticity test of soft liners, the $Molloplast-B^{(R)}$ specimen before and after thermocycling showed highest result. and in case of hard liners, the Dura-Liner $II^{(R)}$ specimen before thermocycling and the $Tokuso-Rebase^{(R)}$ after thermocycling showed highest results. Depending on thermocycling, $Soft-Relining^{(R)}$ $Molloplast-B^{(R)}$ specimens showed significant difference (p<0.05).

  • PDF

THE STUDY ON THE PHYSICAL PROPERTY OF THE PERMANENT SOFT DENTURE LINERS (영구 연성 의치상 이장재의 물리적 성질에 관한 연구)

  • Kim, Yeon-Mi;Bae, Jeong-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.6
    • /
    • pp.809-818
    • /
    • 1999
  • This study was performed to evaluate the tensile bond strength and modulus of elasticity of three permanent soft denture liners (Molloplast $B^{(R)}$, Ufi Gel $C^{(R)},\;Tokuyama^{(R)}$) before and after thermocycling. And their water sorption were also evaluated. Each soft denture liner was bonded to PMMA denture base resin blocks and the tensile bond strength and modulus of elasticity were measured by using universal testing machine. For the water sorption, weight measured after immersion of sea denture liners in $37{\pm}1^{\circ}C$ water bath for 4 weeks. The results were as follows : 1. Molloplast $B^{(R)}$ had the highest tensile bond strength, while Tokuyama had the lowest tensile bond strength. There was no significant difference between $Tokuyama^{(R)}$ and Molloplast $B^{(R)}$ in the both nonthermocycling and thermocycling. There was significant difference in tensile strength of $Tokuyama^{(R)}$ before and after thermocycling(p<0.05). 2. For the modulus of elasticity, there was no significant difference between Ufi Gel $C^{(R)}\;and\;Tokuyama^{(R)}$ in the both nonthermocycling and thermocycling. There was significant difference in modulus of elasticity of $Tokuyama^{(R)}$ before and after thermocycling(p<0.05). 3 The failure modes of Molloplast $B^{(R)}$ and Ufi Gel $C^{(R)}$ were mainley adhesive type and that of $Tokuyama^{(R)}$ was mainly mixed type in case of nonthermocycling and cohesive type after thermocycling. 4. The water sorption of each soft liners was within ${\pm}2%$ in times (p<0.05) but. there was no significant difference among the soft liners in times.

  • PDF

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.

THE EFFECT OF FERMENTED FOODS ON THE COLOR CHANGE OF SOFT DENTURE LINERS (발효음식에 의한 연성 의치상 이장재의 색상 변화에 관한 연구)

  • Cho Seong-Hwan;Lim Heon-Song;Shin Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.572-582
    • /
    • 2004
  • Statement of problem: The clinical criteria of soft lining materials are resilience over an extended period, capability of forming a strong bond with denture base materials, dimensional stability, adequate tear strength, and color stability. Many researches and reports dealt with food colorants or denture cleanser, but not with fermented foods. Purpose : This study was designed to assess what fermented foods, such as soy sauce and red pepper paste that many Koreans have eaten, influence on the color stability of soft denture liners. Material and methods: The color differences (${\Delta}E^*$) were measured by spectrophotometer with different immersion time. For the procedure, thirty disk-shape specimens per 4 soft denture linears(Molloplast-$B^{(R)}$, Ufi Gel $SC^{(R)}$, Dura $Base^{(R)}$, Sofreliner $MS^{(R)}$) were fabricated with a thickness of 2mm and 16mm in diameter. Each 10 specimen were immersed into the beakers of fermented foods distilled water, and $L^*$, $a^*$, $b^*$ values were measured for the color difference(${\Delta}E^*$), on the 1st, 7th, and 28th day with spectrophotometer. Result and conclusion : 1. There were significant differences between samples(soy sauces, red pepper pastes, and distilled water) in Sofreliner $MS^{(R)}$ of 1st day after immersion(p<0.05). There were significant differences between samples in Sofieliner $MS^{(R)}$ and Ufi Gel $SC^{(R)}$ of 7th days after immersion(p<0.05). There were significant differences between samples in Molloplast-$B^{(R)}$ of 28th day after immers ion(p<0.05). 2. In red pepper pastes, ${\Delta}E^*$ values of Molloplast-$B^{(R)}$, Ufi Gel $SC^{(R)}$, Sofrelinev $MS^{(R)}$ weve higher than 3.3. Those values were not clinically acceptable. In soy sauces, ${\Delta}E^*$ values of all denture liners were lower than 3.3. ${\Delta}E^*$values of Ufi Gel $SC^{(R)}$ were higher than those of other denture liners 3. Based on the above results , red pepper paste causes more discoloration than soy sauce.