• 제목/요약/키워드: $M_2X$(M = Cr)

검색결과 236건 처리시간 0.03초

다단 생물반응기에 의한 질소제거 (Nitrogen Removal from Wastewater by a Multi-stage Bio-reactor)

  • 최규철;정일현
    • 환경위생공학
    • /
    • 제13권1호
    • /
    • pp.91-103
    • /
    • 1998
  • Design data for COD and nitrogen removal from wastewater were collected from Pilot's Multi-stage Bio-reactor. Hyraulic conditions and pollutant loadings were varied in order to optimize the biological and operational parameters. Pilot's experimental results summarize as followings. 1. T-N removal efficiency in the organic volumetric loading 0.2 kgCOD/m$^{3}$·d was obtained as maxium of 85% at internal recycle ratio 2.5 and in more ratio than this it was decreased. Organic removal efficiency was about 91% under the overall experimental conditions and not influenced by recycle ratio.. 2. Nitrification reaction was shown as maxium in the SCOD$_{cr}$/NH$^{+}$-N ratio of 6.5 and in more ratio than this it was decreased. Denitrification rate was the maxium as 85% in more than 7.5 of SCOD$_{cr}$/NO$_{x}$-N ratio and in the ratio over this ratio it becomes constant. 3. By utilizing an applied new model of Stover-Kincannon from Monod's kinetic model, concentration of T-N in the effluent according to flow quanity in the influent was estimated as 8.74 and -67.5 respectively. The formula for estimating T-N concentration of effluent was obtained like this: N$_e$=N$_0$(1- $\frac{8.74}{(QN$_0$/A)-67.05}$)

  • PDF

원발 혹은 재발성 비소세포 폐암 환자에서 사이버나이프률 이용한 체부 방사선 수술의 치료 결과 (Treatment Results of CyberKnife Radiosurgery for Patients with Primary or Recurrent Non-Small Cell Lung Cancer)

  • 김우철;김헌정;박정훈;허현도;최상현
    • Radiation Oncology Journal
    • /
    • 제29권1호
    • /
    • pp.28-35
    • /
    • 2011
  • 목 적: 초기 비소세포성 폐암 환자에서 수술적 절제 이외의 국소 치료로 최근 방사선 수술의 사용이 늘고 있다. 이에 저자들은 초기 혹은 재발한 비소세포성 폐암 환자를 대상으로 시행한 체부 방사선 수술의 치료 결과를 분석하여 그 유용성을 알아 보고하고자 한다. 대상 및 방법: 비소세포성 폐 종양에 대하여 방사선 수술이 시행되었던 24명의 환자, 28 lesion에 대하여 후향적 분석을 시행하였다. 이 중 원발성 종양은 19명 재발한 환자는 5명이었고 재발한 환자 5명 중 3명이 이전 치료 부위에서 재발한 환자 이었다. 원발성 종양 19명 중에서 4명은 외부 방사선 치료 후 추가로 방사선 수술을 시행 받았다. 24명의 초기 병기는 IA, IB, IIA, IIB, IIIA, IIIB, IV가 각각 7, 3, 2, 2, 3, 1, 6명이었고, 방사선 수술 당시의 T 병기는 T1 lesion이 13곳, T2가 12곳, T3가 3곳이었다. 방사선 수술은 6 MV X-ray를 이용하였고 planning target volume 1 (PTV1)에 총 방사선량 15~60 Gy(median, 50 Gy)를 3회 혹은 5회에 걸쳐 처방하여 시행하였다. 중앙 추적관찰기간은 469일이었다. 결 과: 28곳의 GTV는 0.7~108.7 mL (median, 22.9 m L)이었고, PTV1 은 5.3~184.8 mL (median, 65.4 m L)이었다. 3개월 반응률은 complete response (CR) 14곳, partial response (PR) 11곳, stable disease (SD) 3곳이었고, 마지막 추적에서의 치료반응은 CR 13곳, PR 9곳, SD 2곳, progressive disease (PD) 4곳이었다. 원발종양으로 초기 병기 IA, IB 10명에서는 50일만에 1명이 폐렴으로 사망하였고 1명이 국소재발 하였으나 나머지 환자는 6개월에서 2년간 국소재발 없이 추적관찰 되고 있으며, IIA-IIB 환자는 4명으로 환자 수가 적어서 뚜렷한 결론을 내리기 어려웠고, 재발성 폐암 환자 5명을 포함하는 10명의 IIIA-IV 병기에서는 사망 3명, 국소재발 1명, loco-regional failure 1명, regional failure 2명으로 좋지 않은 치료 결과를 보였다. 이 중에서 방사선 수술을 시행한 장소에서 재발한 경우는 총 28 1esion 중 4곳으로 85.8%의 국소제어율을 보였다. 방사선치료 양은 biologically equivalent dose (BEd) 100 $Gy_{10}$ 이하인 8 lesion 중에서 3 lesion에서 국소 재발하여 100 $Gy_{10}$ 이상인 20 lesion 중에서는 1 lesion에서만 재발한 경우보다 나빴다. 또한 중앙부의 종양과 방사선수술 당시의 병기가 T2 이상인 경우가 재발이 많았다. 결 론: 비소세포성 폐암환자에서 사이버나이프를 이용한 체부 방사선 수술은 부작용이 적으면서 높은 국소제어율을 얻을 수 있는 치료이며, 주변부의 T1 병기의 폐암에 대해서 BED 100 $Gy_{10}$ 이상의 방사선 치료가 국소제어율을 높이는데 도움이 된다고생각된다.

Ni Nanoparticles Supported on MIL-101 as a Potential Catalyst for Urea Oxidation in Direct Urea Fuel Cells

  • Tran, Ngan Thao Quynh;Gil, Hyo Sun;Das, Gautam;Kim, Bo Hyun;Yoon, Hyon Hee
    • Korean Chemical Engineering Research
    • /
    • 제57권3호
    • /
    • pp.387-391
    • /
    • 2019
  • A highly porous Ni@MIL-101catalyst for urea oxidation was synthesized by anchoring Ni into a Cr-based metal-organic framework, MIL-101, particles. The morphology, structure, and composition of as synthesized Ni@MIL-101 catalysts were characterized by X-Ray diffraction, Fourier transform infrared spectroscopy, scanning electron microscopy, and transmission electron microscopy. The electro-catalytic activity of the Ni@MIL-101catalysts towards urea oxidation was investigated using cyclic voltammetry. It was found that the structure of Ni@MIL-101 retained that of the parent MIL-101, featuring a high BET surface area of $916m^2g^{-1}$, and thus excellent electro-catalytic activity for urea oxidation. A $urea/H_2O_2$ fuel cell with Ni@MIL-101 as anode material exhibited an excellent performance with maximum power density of $8.7mWcm^{-2}$ with an open circuit voltage of 0.7 V. Thus, this work shows that the highly porous three-dimensional Ni@MIL-101 catalysts can be used for urea oxidation and as an efficient anode material for urea fuel cells.

Manufacturing and Macroscopic Properties of Kinetic Spray Ni-Cr-Al-Y Coating Layer

  • Kim, Ji Won;Lee, Ji Hye;Jang, Hae Chang;Lee, Kee-Ahn
    • 한국분말재료학회지
    • /
    • 제22권6호
    • /
    • pp.408-412
    • /
    • 2015
  • This study attempts to manufacture a Ni-Cr-Al-Y coating layer using a kinetic spray process and investigates the microstructure and physical properties of the manufactured layer. The Ni-22Cr-10Al-1Y (wt.%) composition powder is used, and it has a spherical shape with an average diameter of $23.7{\mu}m$. Cu plate is used as the substrate. Optical microscope, X-ray diffraction, scanning electron microscope and Vickers hardness test are carried out to characterize the macroscopic properties of the coating layer. Furthermore, the coating layer underwent vacuum heat treatment at temperatures of $400^{\circ}C$ and $600^{\circ}C$ for 1 hour to check the effect of heat treatment temperature on the properties. The manufactured coating layer is 1.5 mm thick, and featured identical phases to those found in the powder. The porosity of the coating layer is measured at 2.99%, and the hardness is obtained at $490.57H_v$. The layer shows reduced porosity as heat treatment temperature increased, and hardness is reduced at $400^{\circ}C$ but shows a slight increase at $600^{\circ}C$. Based on the findings described above, this study also discusses possible manufacturing methods for a Ni-Cr-Al-Y coating layer using the kinetic spray process.

Ni-22Cr-18Fe-9Mo계 ODS 합금의 미세조직 및 고온인장 특성 평가 (Microstructural Evaluation and High Temperature Mechanical Properties of Ni-22Cr-18Fe-9Mo ODS Alloy)

  • 정석환;강석훈;한창희;김태규;김도향;장진성
    • 한국분말재료학회지
    • /
    • 제18권5호
    • /
    • pp.456-462
    • /
    • 2011
  • Yttrium oxide is one of the most thermo-dynamically stable materials, so that it is generally used as a dispersoid in many kinds of dispersion strengthed alloys. In this study, a nickel-base superalloy is strengthened by dispersion of yttrium oxide particles. Elemental powders with the composition of Ni-22Cr-18Fe-9Mo were mechanically alloyed(M.A.) with 0.6 wt% $Y_2O_3$. The MA powders were then HIP(hot isotactic press)ed and hot rolled. Most oxide particles in Ni-22Cr-18Fe-9Mo base ODS alloy were found to be Y-Ti-O type. The oxide particles were uniformly dispersed in the matrix and also on the grain boundaries. Tensile test results show that the yield strength and ultimate tensile strength of ODS alloy specimens were 1.2~1.7 times higher than those of the conventional $Hastelloy^{TM}$ X(R), which has the same chemical compositions with ODS alloy specimens except the oxide particles.

일반 X-선 촬영에서의 환자피폭선량에 관한 조사연구 (Patient Dose for Diagnostic Radiological Procedures in Korea)

  • 김유현;최종학;김성수;이창엽;이영배;김철민
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2004년도 제29회 추계학술대회 발표논문집
    • /
    • pp.59-63
    • /
    • 2004
  • IAEA에서 제공한 선량기준은 서양 사람을 기준으로 개발된 것이어서 우리 한국 사람에게는 맞지 않고, 상대적으로 우리나라의 환자선량은 적으리라 예상된다. 따라서 선량기준을 따로 개발해야할 필요가 있다. 그래서 본 연구팀은 병원협회에 등록되어 있는 종합병원 278개를 대상으로 환자 피폭에 대한 설문조사를 실시하였다. 설문회수율은 57.9%였으며 각 병원에서의 촬영조건을 기초로 NDD법을 이용하여 환자 피폭선량을 계산하였고 설문지를 분석한 결과를 보고한다.

  • PDF

Demonstration of Nonpolar a-plane Light Emitting Diodes on r-plane Sapphire Substrate by MOCVD

  • Son, Ji-Su;Baik, Kwang-Hyeon;Song, Hoo-Young;Kim, Ji-Hoon;Kim, Tae-Geun;Hwang, Sung-Min
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.147-147
    • /
    • 2011
  • High crystalline nonpolar a-plane (11-20) nitride light emitting diodes (LEDs) have been fabricated on r-plane (1-102) sapphire substrates by metalorganic chemical-vapor deposition (MOCVD). The multi-quantum wells (MQWs) active region is consists of 4 periods the nonpolar a-plane InGaN/GaN(a-InGaN/GaN) on a high quality a-plane GaN (a-GaN) template grown by using the multibuffer layer technique. The full widths at half maximum (FWHMs) of x-ray rocking curve (XRC) obtained from phiscan of the specimen that was grown up to nonpolar a-plane GaN LED layers with double crystal x-ray diffraction. The FWHM values were decreased down to 477 arc sec for $0^{\circ}$ and 505 arc sec for $-90^{\circ}$, respectively. After fabricating a conventional lateral LED chip which size was $300{\times}600{\mu}m^2$, we measured the optical output power by on-wafer measurements. N-electrode was made with Cr/Au contact, and ITO on p-GaN was formed with Ohmic contact using Ni/Au followed by inductively coupled plasma etching for mesa isolation. The optical output power of 1.08 mW was obtained at drive current of 20 mA with the peak emission wavelength of 502 nm.

  • PDF

경북 봉화지역 홍제사 화강암 내에 배태하는 견운모광상의 산상 및 구성광물 (Occurrence and Mineralogy of Sericite Deposit in the Hongjesa Granite from the Bonghwa Area in Kyungsangbuk-do, Korea)

  • 오지호;황진연;고상모;곽규원;이효민;지세정
    • 한국광물학회지
    • /
    • 제21권1호
    • /
    • pp.67-83
    • /
    • 2008
  • 경북 봉화지역의 선캠브리아기 홍제사 화강암 내에는 견운모 광상이 분포한다. 이 지역의 대현광산과 성황광산에서 산출되는 견운모에 대하여 현미경 관찰, X-선회절분석, 전자현미분석, X-선형광분석, ICP분석 등을 통하여 지화학적 및 광물학적 특성을 조사하고 그 형성과정을 검토하였다. 이 지역 견운모광상은 열수변질작용에 의해 화강암을 모암으로 한 견운모화작용에 의해 형성되었다. 이곳에 나타나는 광물조합과 그 산출상태로부터 4가지치 변질대로 구분되었다. 이러한 변질대는 점이적인 열수변질작용에 의해 형성된 것으로 나타났다. 이곳에서 산출하는 견운모는 광물화학적으로 모두 일라이트에 해당되는 것으로 나타났으며, 다구조형도 모두 $2M_1$으로 매우 단순한 형태를 보였다. 거의 순수한 견운모 광석은 여러 색을 나타냈으나, 주화학성분이나, 결정구조에서의 차이는 나타나지 않았다. 미량성분을 검토한 결과 진한 녹색을 띠는 것은 Cr이 상대적으로 다량 함유되고, 흑색의 것은 Ti이 상대적으로 많은 것으로 나타났다. 모암인 홍제사 화강암내에서 견운모 광상이 발달하는 것은 단층과 같은 단열구조와 관련되는 것으로 나타났다. 엽납석 및 고령석 등의 다른 변질광물은 나타나지 않으며, 열극대를 따라 변질된 단순한 형태의 열수광상인 것으로 나타났다.

Na-셀룰로스에 대한 금속이온들의 흡착성에 관한 연구 (Adsorption Behavior of Metal ions by Na-Cellulose)

  • 이택혁;윤국중
    • 분석과학
    • /
    • 제7권3호
    • /
    • pp.271-276
    • /
    • 1994
  • 셀룰로스에 대한 +2와 +3가 금속이온들의 흡착성을 최적 조건에서 실험하였는데, +2가 금속이온으로 Cu(II), Zn(II), Pb(II) 및 Cd(II) 이온을 선택하였으며, +3가 금속이온으로 Cr(III)와 Fe(III) 이온을 선택하여 실험하였다. 셀룰로스에 대한 흡착능을 증대시키기 위하여 셀룰로스를 2M NaOH로 처리하여 Na-셀룰로스를 제소하였다. 셀룰로스에 대한 금속이온 흡착능은 매우 작아서 고분자 흡착제로서의 효과가 없었으나 Na-셀룰로스는 고분자 흡착제로서 매우 효과적이었다. Na-셀룰로스에 대한 금속이온들의 흡착은 뱃치법으로 실험하였다. 최적 조건에서 Na-셀룰로스에 대한 금속이온들의 흡착은 +2가 금속이온들은 1:2, +3가 금속이온들은 1:3의 흡착비로 흡착하는 이온교환 흡착이었다. Na-셀룰로스에 대한 금속이온들의 흡착엔탈피는 -18kcal/mol 정도였으며, carboxymethylcellulose(CMC)와 Dowex 50W-X8 수지와 비교 실험한 결과, Na-셀룰로스에 대한 금속이온들은 흡착은 이온교환흡착으로, 비슷한 작용기를 가지고 있는 CMC와 비슷한 흡착엔탈피를 보였다.

  • PDF

복부 단순촬영의 이상적 영상구현을 위한 F. S system과 C.R system의 촬영조건 비교분석 (The Comparative Analysis of Exposure Conditions between F/S and C/R System for an Ideal Image in Simple Abdomen)

  • 손상혁;송영근;김제봉
    • 대한디지털의료영상학회논문지
    • /
    • 제9권1호
    • /
    • pp.37-43
    • /
    • 2007
  • I. 목적 : 본 연구에서는 복부의 이상적 영상 구현을 위한 Film Screen (F.S) System과 Computed Radiography(C.R) System의 촬영조건의 차이를 비교 분석해 보고, C.R system에서 촬영조건 변화에 따른 영상의 특성을 분석함으로써, C.R 환경에서 촬영조건 설정의 중요성을 살펴보고자 한다. II. 대상 및 방법 : F.S system에서 촬영 조건을 70kVp로 고정시키고, mAs를 단계적으로 변화시켜 복부 단순겸사를 시행하여 영상을 획득한 후, 진단방사선과 전문의와 방사선사로 구성된 영상평가 팀의 정량적, 정성적 분석을 통하여 F.S system 최적의 영상을 선정하였다. 동일 환자를 대상으로 C.R system 에서 위와 동일한 방법으로 영상을 획득한 후, F.S system과 C.R system의 영상의 특성곡선(Characteristic Curves)을 비교분석하고, C.R system에서 촬영조건 변화에 따른 복부 장기의 농도변화 및 영상의 특정을 비교 평가하였다. 마지막으로, F.S system과 C.R system의 최적의 영상 획득을 위한 촬영조건의 차이를 비교 분석하고, C.R 환경에서 촬영조건의 중요성을 살펴보았다. III. 결과 : F.S system에서 영상평가팀의 평가를 통하여 선택된 최적 영상의 촬영 조건은 70kVp, 20mAs로 나타났다. C.R system에서는 촬영조건 12mAs, 70kVp에서 복벽과 직접노출구역의 농도 차이가 최대인, 진단적 가치가 높은 영상을 얻을 수 있었다. C.R system에서는 (70kVp로 고정)변화한 mAs량(3.2mAs, 8mAs, 12mAs, 16mAs, 20mAs)에 상관없이 복부 장기는 거의 통일한 농도를 나타냈으며 12mAs 기준으로 노출 조건의 감소 또는 증가에 따라서 복벽과 직접노출부분의 명확한 구분이 불가능하였으며, mAs량이 낮아질수록 양자반점(Quantum Mottle)으로 인한 artifact는 증가함을 볼 수 있었다. IV. 결론 : 위의 실험 결과 본원 system의 복부단순검사에서는 C.R system 사용 시 F.S system 보다 촬영 조건을 약 40% 감소시킬 수 있었다. C.R환경에서 x-ray장치 Image processing 장치, 자동 감도조절(EDR : exposure data recognition processing) 장치, PACS 등 사용하는 장비들의 특성을 분석하여 적정 노출조건을 재설정한다면, 최소의 피폭선량으로 최대의 영상정보를 지닌 진단적 가치가 높은 영상의 획득이 가능하다고 사료된다.

  • PDF