• Title/Summary/Keyword: $M_1$-index

Search Result 3,460, Processing Time 0.033 seconds

METALLICITY DETERMINATION FOR A GLOBULAR CLUSTER BY SPECTRAL INDICES

  • LEE SANG-GAK
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.2
    • /
    • pp.157-170
    • /
    • 1996
  • In order to determine the metallicity of a globuar cluster, M3,by using the spectral indices, a kind of index grid has been establshed by stars in globular clusters, M3, M15, M71 and old open cluster, NGC 188. The indices were measured from the medium resolution spectra of about $2{\AA}$. The summed indices were used to determine metallicity in order to increase signals. It is found that the core depth index is measured more accurately and leads result more accurate than the pseudo-equivalent width index. This method can be further improved by including many more calibration globular clusters of various metallicity to make finer grids. By this method, the metallicity of M3 is determined as $[Fe/H] = -1.46\pm0.15$.

  • PDF

Optimum analysis of optical waveguide refractive index for directional couple ins (방향성 결합을 위한 광도파로 굴절율의 최적화 해석)

  • 전용우;채기병;소대화;장지호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.11a
    • /
    • pp.39-42
    • /
    • 1993
  • In this paper, we performed theoretical simulation for directional coupler using BPM program. Simulation results shored that the optimum optical waveguide refractive index between the guides were 3$\mu\textrm{m}$. Using the parameters of n$_1$=2.25, n$_2$=2.25, n$_3$=2.2, gap=3$\mu\textrm{m}$, W= 30$\mu\textrm{m}$, $\Delta$z=0.l$\mu\textrm{m}$, λ=1.5$\mu\textrm{m}$, we decided other design parameters. When we applied 40[V] in the optimum condition of the directional coupling effect, we concluded the refractive index variation of 0.001.

  • PDF

Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation (디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로)

  • Jin, Seong-jin;Im, In-Chul;Cho, Ji-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was $30.17{\pm}4.73$ and the average waist circumference was $66.91{\pm}4.67cm$. The mean Body Mass Index value was $20.21{\pm}2.23$, the mean value of mAs was $3.04{\pm}0.78$, and the mean value of Bureau of Radiological Health was $79.83{\pm}8.45$. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

Ecological Changes of Seunghwanglim -Natural Monument No. 93- Wonju Seungnamri (원주 성남리 성황림-천연기념물 제 93호-의 생태적 변화)

  • Kim, Gab-Tae
    • Korean Journal of Environment and Ecology
    • /
    • v.21 no.6
    • /
    • pp.559-564
    • /
    • 2007
  • This research is aimed at finding out the ecological change of Seunghwanglim through the examination of vegetational change of tree seedlings of old giant trees growing at Seunghwanglim [Seunghwang Forest designated as a Natural Monument No.93] after the installation of protective iron fence. The survey results are as follows: First, as a result of keeping out people by installing a protective iron fence in 1989, soil hardness of the plane forest was greatly improved except the area used as roads. The seedlings of the plane forest, whose damage index is 2,3,4, were found to have the highest 1,202 $individuals/400m^2$, and those of the plane forest, whose damage index is 1, were revealed to have 565 $individuals/400m^2$, and those of the slope forest were found to have 403 $individuals/400m^2$. The number of the young sapling[taller than 2 meters] individuals of the plane forest whose damage index is 1 was found to be the most $48/400m^2$, and that of the plane forest whose damage index is 2, 3, 4- was $31/400m^2$, and that of the slope forest proved to be $14/400m^2$. In the plane forest whose damage index is 2, 3, 4, the saplings of the Ulmus davidiana var. japonica and Acer triflorum are relatively much distributed, and in the plane forest whose damage index is 1, many saplings of the Prunus padus and Styrax obassia, were found to grow and in the slope forest, many saplings of the Acer pictum subsp. mono and Acer pseudo-sieboldianum. were found to grow. Many seedlings of Rubus spp. - R. oldhamii, R. coreanus and R. crataegifolius. - and Akebia quinata were growing vigorously on plane forest, but they might decrease in number with the increasing number of the tree saplings.

Effect of General Ventilation Rate on Concentrations of Gaseous Pollutants Emitted from Enclosed Pig Building (밀폐형 돈사 작업장의 전체 환기율이 가스상 오염물질 노출 농도 변화에 미치는 영향)

  • Kim, Ki Youn;Seo, Sung Chul;Choi, Jeong-Hak
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.1
    • /
    • pp.46-51
    • /
    • 2014
  • Objectives: The principal aim of this study was to compare the concentrations of gaseous pollutants emitted in enclosed pig buildings between different rates of general ventilation and determine the variations in the patterns of gaseous pollutants as affected by ventilation rate. Materials and Methods: The experiment was performed in the growing/finishing room($20.0m{\times}12.0m{\times}3.0m$) of a pig confinement building located on the experimental farm of Seoul National University. The conditions of the general ventilation rate for three treatments were 30%($4.12m^3s^{-1}$), 50%($6.87m^3s^{-1}$) and 70%($9.61m^3s^{-1}$). The data presented in the study were collected overa total of 45 days, 15 days for each of the three treatments from March to May 2011. A total of six air samplings were taken at 1.5m above the floor of the pig building. The environmental agents measured in the pig building were ammonia, hydrogen sulfide and odor concentration index for gaseous pollutants with temperature and hydrogen sulfide for thermal factors. Results: There were significant differences in the ammonia and odor concentration index in the pig building among the three general ventilation rate conditions(p<0.05), whereas hydrogen sulfide did not show a significant difference among three conditions of general ventilation rate(p>0.05). As the general ventilation rate applied to the pig building increases, it appears that all the indoor environmental agents measured in this study simultaneously decrease. Conclusions: The gaseous pollutants significantly affected by the general ventilation rate in pig building were ammonia and odor concentration index(p<0.05). However, it was found that hydrogen sulfide and thermal factors, temperature and relative humidity were not influenced significantly by variation in the general ventilation rate.

The Structure of Plant Community in Jungdaesa-Birobong Area, Odaesan National Park (오대산국립공원 중대사-비로봉 구간 식물군집구조)

  • Han, Bong-ho;Choi, Jin-woo;Noh, Tai-hwan;Kim, Dong-wook
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.5
    • /
    • pp.764-776
    • /
    • 2015
  • This study aims to identify the structure of the plant community, and the ecological succession sere and the change in the forest ecosystem in Jungdaesa-Birobong area, Odaesan National Park_(i._e., located at high altitudes(over 1,000m)). It seeks to offer the basic data for the planning of vegetation management. In order to verify the status of the forest vegetation between Jungdaesa-Birobong, seventeen plots(size is $20m{\times}20m$) were set up as research sites at high altitudes. Importance value, distribution by diameter at breast height(DBH), the growth volume and age of the sample trees, similarity index and species diversity index of each survey plot were analysed. According to the results of DCA(Detrended Correspondence Analysis), one of the multivariate statistical techniques. It was found that the plant communities were classified into five groups: community I_(Quercus mongolica-Tilia amurensis community), community II_(Q. mongolica-Deciduous broad-leaved community), community III_(Q. mongolica-Pinus koraiensis community), community IV_(Abies holophylla-Q. mongolica community) and community V_(A. holophylla-Deciduous broad-leaved community). Community I which is dominated by Quercus mongolica and Deciduous broad-leaved communities is located at an altitude of over 1,300 meters(ranging from 1,335m to 1,495m), the community IV and V which are dominated by Abies holophylla are located at an altitude of under 1,200 meters(ranging from 1,115m to 1,175m) and the community II and III which include the main species of Quercus mongolica, Pinus koraiensis and Abies holophylla are located at an altitude of between 1,160 meters and 1,300 meters. The results showed that Quercus mongolica tends to have a higher importance value of woody species at a higher altitude while Abies holophylla tends to have higher importance value at a lower altitude. For the importance value woody species and -DBH class distribution, the communites I, II and III are expected to continuously maintain the present status. Whereas, for the influence of communities IV and V, Q. mongolica is predicted to be weakened. The age of sample trees was between 85 and 161; the average age was 123. The index of Shannon's Species diversity (H') showed heterogeneity was found among community I_(i._e., located at high altitude) and communities IV and V_(i._e., located at low altitude). As a results of analysing the index of Shannon's Species diversity (H': unit: $400m^2$), community III showed the highest diversity intex with 1.1109 followed by community II with 1.0475, community I with 1.0125, community IV with 0.9918 and community V with 0.8686. This study verified that the index of Shannon's species was significantly different by plant communities. For instance, when comparing the index of Shannon's species diversity in Quercus mongolica communities of this study and that of past relevant research, the value of index is very similar. However, the diversity index for the community which is dominated by Abies holophylla showed lower value when compared to the results from past relevant research.

Analysis of the Relationship between the Preoperative Pulmonary Artery Index and the Postoperative Cardiac Performance in Cyanotic Congenital Heart Disease. (폐혈류감소를 동반한 선천성 심장기형에서 술전 폐동맥발육과 조기 술후 혈역학적 변화와의 관계)

  • Han, Jae-Jin;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.601-608
    • /
    • 1989
  • We sought the relationship between the pulmonary artery development and cardiac performance from the analysis of the 36 cyanotic congenital heart disease patients [mainly TOF] who were operated and indwelled the pulmonary artery and left atrial pressure monitoring catheters for the postoperative care at the department of Thoracic and Cardiovascular Surgery SNUH in 1988. They were pre-evaluated of the pulmonary artery index from the cineangiographic films and post-operatively, calculated the cardiac index from the arterial and mixed venous blood gas and also measured the mean left atrial pressure and total inotropic supporting amount after operation. The post-operative cardiac indices were 3.46 * 1.03 1/min/M2 [immediate postoperative], 3.31 [ 1.08 [postoperative 6 hrs], 3.29 [ 1.01 [12 hrs], 3.54 * 1.02 [24 hrs], 3.92 * 1.14 [48 hrs], respectively. We divided the patients the group A and group B from the size of the pulmonary artery index, that is, group A was below 200 mm2/M2 and group B above 200 mm2/M2 of the pulmonary artery index. The cardiac indices and left atrial pressure between the group A and B were not different in the view of the statistical significance but the total post-operative inotropic amount of group A was more than group B and it was significant statistically. We concluded that the smaller the pulmonary artery index is, the more postoperative supportive treatment [for example, inotropics] for the enhancement of cardiac performance is needed, and indirectly, which means that the pulmonary artery index was correlated with the postoperative cardiac performance in cyanotic congenital heart disease.

  • PDF

A Study on the Oral Hygien Index Change according to Comprehensive Dental Hygiene Care Treatment (포괄 치위생처치에 따른 구강환경지수변화 연구)

  • Lee, Eun-Sook;Lee, Cheon-Hee
    • The Korean Journal of Health Service Management
    • /
    • v.5 no.3
    • /
    • pp.145-155
    • /
    • 2011
  • This study is Dental Hygiene Department of G University for comprehensive dental hygiene control and treatment weekly for four weeks from September 16 to October 20, 2010, excluding those who visited for ambulatory treatment of systemic diseases. For the 90 subjects, we performed oral examination, measured Simplified Oral Hygiene Index (S-OHI), Modified Patient Hygiene Performance (PHP-M), and O' Leary Index, and applied comprehensive dental hygiene control. First, as to the change of OHI according to age, the index in the 1st measurement was 3.43 in those under 35 and 3.17 in those aged 35 or older, so it was higher in the younger group, but in the 2nd measurement it was 1.89 in those under 35 and 2.14 in those aged 35 or older, and in the 3rd measurement it was 1.22 in those aged 35 or older, so it was higher in the older group. Second, as to the change of PHP-M according to age, the index in the 1st measurement was 50.35 in those under 35 and 43.16 in those aged 35 or older, soit was higher in the younger group, but in the 2nd measurement it was 31.97 in those under 35 and 28.88 in those aged 35 or older, and in the 3rd measurement it was 21.31 in those aged 35 or older, so it was higher in the older group.

Distribution of millipedes in relation to altitude and flora on mt. chiri (智異山의 植生과 標高에 따른 노래기類의 分布)

  • Lim, kil-young;Tae-heung kim;Joon-soo kwak
    • The Korean Journal of Ecology
    • /
    • v.15 no.4
    • /
    • pp.329-335
    • /
    • 1992
  • Bionomics of diplopodes was studid near chongyongchi in the chiri mountains from sept. 1990 to dec. 1991 by surveying 10 sample sites at 12 occasions. During this period 13 species of diplopodes from 11 genera, 8 families, and 6 orders were collected. Species were more diversed under quercus mongolica followed by quercus serrata and pinus densiflora sp. epenerchodus koreanus bifidus, and e. k. koreanus were found in all sample sites and these 6 species have been reported to be distributed throughout south korea. yamasinaium sp., riukiaria semicirculalis, parafontaria koreanus, and sicotanus eurygaster were found only under quercus mongolica community and postulated to be related to diet meanwhile other enviromental factors such as temperature, soil ph, and altitude should be taken into consideration. Species diversity index was higher at altitude 700m followed by at 900m, 1, 000m, 800m, 600m, 500m, 1, 100m, 400m, 300m, and 1, 200m in discending order likely due to the enviromental factors such as climatic and edaphic affects, disturbance by human, and degree of floral diversity. Species similarity index was highest 0.78 between altitude 500m and 600m sample sites could be grouped into 3, namely first 300m, 400m, second 500m, 600m, 700m, 1, 000m, 800m, 900m, and third 1, 100m, 1, 200m.

  • PDF

Measurement of Effective Refractive Index of Nematic Liquid Crystal in Fabry-Perot Etalon

  • Ko, Myeong Ock;Kim, Sung-Jo;Kim, Jong-Hyun;Lee, Bong Wan;Jeon, Min Yong
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.346-350
    • /
    • 2015
  • We report a measurement of the effective refractive index of a nematic liquid crystal (NLC) inside a Fabry-Perot (FP) etalon according to the applied electric fields. The effective refractive index of the NLC depends on the intensity of the applied electric field. A wavelength-swept laser with a polygon-scanner-based wavelength filter is used as a wide-band optical source to measure the effective refractive index of the NLC. The bandwidth of the optical source is greater than 90 nm around 1300 nm. The fabricated NLC FP etalon consists of glass substrates, gold layers as the electrodes with highly reflective surfaces, polyimide layers as the planar alignment layers, and an LC layer. Furthermore, we measured the Freedericksz transition voltages for three types of NLC FP etalons having thicknesses of $30.6{\mu}m$, $55.4{\mu}m$, and $108.8{\mu}m$. The Freedericksz transition voltages in the three cases are nearly equal. The measured effective refractive indices in the three cases decreased from 1.67 to 1.51 as the applied electric field intensity was increased. Beyond the threshold electric field, the effective refractive indices quickly decreased and eventually saturated at a value of 1.51 for all cases.