• Title/Summary/Keyword: $M_{max}$

Search Result 1,669, Processing Time 0.029 seconds

Adjacent Interference Analysis between M-WiMAX OFDMA/TDD and WCDMA FDD System in the 2.6 GHz Band Part II : Adjacent Interference Analysis with Smart Antenna in M-WiMAX System (2.6 GHz 대역에서 M-WiMAX OFDMA/TDD 시스템과 WCDMA FDD 시스템간의 상호 간섭 분석 Part II : Adjacent Interference Analysis with Smart Antenna in M-WiMAX System)

  • Wang, Yu-Peng;Ko, Sang-Jun;Chang, Kyung-Hi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.6A
    • /
    • pp.588-599
    • /
    • 2007
  • This paper presents the coexistence issues between M-WiMAX TDD and WCDMA FDD systems. To improve the M-WiMAX system performance and to reduce the adjacent channel interference to WCDMA FDD system, transmit and receive beamforming techniques are applied in the base stations of M-WiMAX system. Furthermore, we propose an adjacent channel interference modeling methodology, which captures the effect of transmit beamforming on the adjacent channel interference. Besides, we verify the performance improvement in the uplink of WCDMA system due to the transmit beamforming in M-WiMAX downlink based on the proposed adjacent channel interference modeling methodology. We also verify the performance enhancement due to the receive beamforming in the uplink of M-WiMAX system through system level Monte Carlo simulations, considering random user position, the effect of shadowing and multi-path fading channel. Discussions on the gain of applying transmit and receive beamforming in M-WiMAX system comparing the case of SISO system are also included. Furthermore, we present the performance of cosited M-WiMAX and WCDMA systems, considering commercial deployment, additional channel filter at base stations and the effects of TxBF and RxBF.

MAX-INJECTIVE, MAX-FLAT MODULES AND MAX-COHERENT RINGS

  • Xiang, Yueming
    • Bulletin of the Korean Mathematical Society
    • /
    • v.47 no.3
    • /
    • pp.611-622
    • /
    • 2010
  • A ring R is called left max-coherent provided that every maximal left ideal is finitely presented. $\mathfrak{M}\mathfrak{I}$ (resp. $\mathfrak{M}\mathfrak{F}$) denotes the class of all max-injective left R-modules (resp. all max-flat right R-modules). We prove, in this article, that over a left max-coherent ring every right R-module has an $\mathfrak{M}\mathfrak{F}$-preenvelope, and every left R-module has an $\mathfrak{M}\mathfrak{I}$-cover. Furthermore, it is shown that a ring R is left max-injective if and only if any left R-module has an epic $\mathfrak{M}\mathfrak{I}$-cover if and only if any right R-module has a monic $\mathfrak{M}\mathfrak{F}$-preenvelope. We also give several equivalent characterizations of MI-injectivity and MI-flatness. Finally, $\mathfrak{M}\mathfrak{I}$-dimensions of modules and rings are studied in terms of max-injective modules with the left derived functors of Hom.

Effects of Dexamethasone and DHEA on the Changes of Glutamate and Polyamine Uptake in Rat Astrocytes by Lipopolysaccharide and Antimycin A

  • Choi, Sang-Hyun;Lee, Bum;Shin, Kyung-Ho;Min, Bon-Hong;Chun, Yeon-Sook;Chun, Boe-Gwun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.3 no.2
    • /
    • pp.137-146
    • /
    • 1999
  • Interactions among dexamethasone, dehydroepiandrosterone (DHEA), lipopolysaccharide (LPS), and antimycin A on the glutamate uptake and the polyamine uptake were investigated in primary cultures of rat cerebral cortical astrocytes to examine the effects of dexamethasone and DHEA on the regulatory role of astrocytes in conditions of increased extracellular concentrations of glutamate or polyamines. 1. $[^3H]Glutamate$ uptake: LPS and antimycin A decreased $V_{max},$ but both drugs had little effect on $K_m.$ Dexamethasone also decreased basal $V_{max}$ without any significant effect on $K_m.$ And dexamethasone further decreased the antimycin A-induced decrease of $V_{max}.$ DHEA did not affect the kinetics of basal glutamate uptake and the change by LPS or antimycin A. 2. $[^{14}C]Putrescine$ uptake: LPS increased $V_{max},$ and antimycin A decreased $V_{max}.$ They showed little effect on $K_m.$ Dexamethasone decreased $V_{max}$ of basal uptake and further decreased the antimycin A-induced decrease of $V_{max},$ and also decreased $V_{max}$ to less than control in LPS-treated astrocytes. DHEA did not affect $K_m$ and the change of $V_{max}$ by LPS or antimycin A. 3. $[^{14}C]Spermine$ uptake: Antimycin A decreased $V_{max},$ and LPS might increase $V_{max}.\;K_m$ was little affected by the drugs. Dexamethasone decreased basal $V_{max}$ and might further decrease the antimycin A-induced decrease of $V_{max}.$ And dexamethasone also decreased $V_{max}$ to less than control in LPS-treated astrocytes. DHEA might increase basal $V_{max}$ and $V_{max}$ of LPS-treated astrocytes. 4. $V_{max}$ of glutamate uptake by astrocytes was increased by putrescine (1000 ${\mu}M$ & 2000 ${\mu}M$) and spermidine (200 ${\mu}M,$ 500 ${\mu}M$ & 2000 ${\mu}M$). Spermine, 200 ${\mu}M$ (and 100 ${\mu}M$), also increased $V_{max},$ but a higher dose of 2000 ${\mu}M$ decreased $V_{max}.\;K_m$ of glutamate uptake was not significantly changed by these polyamines, except that higher doses of spermine showed tendency to decrease $K_m$ of glutamate uptake. In astrocytes, dexamethasone inhibited the glutamate uptake and the polyamine uptake in normal or hypoxic conditions, and the polyamine uptake might be stimulated by LPS and DHEA. Polyamines could aid astrocytes to uptake glutamate.

  • PDF

Performance of M-ary QAM demapper with Max-Log-MAP (Max-Log-MAP 방식을 이용한 M-ary QAM Demapper의 성능)

  • Lee Sang-Keun;Lee Yun-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.1
    • /
    • pp.36-41
    • /
    • 2006
  • In this paper, we present the performance of iterative decoding with a Turbo decoder and a M-ary QAM(Quadrature Amplitude Modulation) demapper. The demappers are designed with Max-Log-MAP algorithm and it's approximated one. In addition, we provide implementing block for the approximated algorithm. From the results of computer simulations, the approximated algorithm of the Max-Log-MAP has little bit worse than the Max-Log-MAP but suggests low complexity for practical implementation.

Contrast Sensitivity as a function of spatial frequency by using polarization (편광을 이용한 눈의 공간주파수-대비민감도 함수 측정기구 설계)

  • Kim, Young-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.43-48
    • /
    • 2000
  • It was to adjust the luminance of light by the rotation angle of the polarizes and analyzer. The luminance value Lmax, Lmin of Contrast Sensitivity could be obtained from the rotation angle ${\theta}_m$ of the average luminance($L_m$), the rotation angle(${\theta}_{max}$, ${\theta}_{min}$) of the maximum and the minimum's amplitude. $$L_{max}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1+C_s^{-1})$$ $$L_{min}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1-C_s^{-1})$$ We obtained the rotation angle(${\theta}_{max}$, ${\theta}_{min}$) of the polarizes and analyzer from the rotation angle ${\theta}_m$ of the average luminance($L_m$) and the Contrast Sensitivity($C_s$). $${\theta}_{max}=cos^{-1}[cos{\theta}_m{\cdot}(1+C_s^{-1})^{1/2}]$$ $${\theta}_{min}=cos^{-1}[cos{\theta}_m{\cdot}(1-C_s^{-1})^{1/2}]$$.

  • PDF

Temperature Dependence of DC and RF characteristics of CMOS Devices (RF-CMOS소자의 온도에 따른 DC및 RF 특성)

  • Nam, Sang-Min;Lee, Byeong-Jin;Hong, Seong-Hui;Yu, Jong-Geun;Jeon, Seok-Hui;Gang, Hyeon-Gyu;Park, Jong-Tae
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.3
    • /
    • pp.20-26
    • /
    • 2000
  • In this work, the degradation of g$_{m}$ , f$_{T}$ and f$_{max}$ of RF-CMOS devices have been characterized at elevated temperature. Since MOS transistors in RF applications are usually in saturation region, a simple empirical model for temperature dependence of g$_{m}$ at any measurement bias has been suggested. Because f$_{T}$ and f$_{max}$ of CMOS devices are proportional to g$_{m}$, the temperature dependence of f$_{T}$ and f$_{max}$ could be obtained from the temperature dependence of g$_{m}$. It was found that the degradation of f$_{T}$ and f$_{max}$ at elevated temperature was due to the degradation of g$_{m}$. From the correlation between DC and RF performances of CMOS devices, we can predict the enhanced f$_{T}$ and f$_{max}$ performances at low temperature.

  • PDF

The Development of Prediction Equation for Estimating VO2max from the 20 m PSRT in Korean Middle-School Girls. Exercise Science (20 m 점증 왕복달리기 검사를 이용한 여중생의 VO2max 추정식 개발)

  • Park, Dong-Ho;Song, Jung-Ran;Lee, Sang-Hyun;Kim, Chang-Sun
    • Exercise Science
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • The purpose of this study was to develop and validate regression models to estimate maximal oxygen uptake (VO2max) from the 20 m Progressive Shuttle Run Test (20 m PSRT) in Korean middle-school girls aged 13-15 years. The 20 m PSRT and VO2max were assessed in a sample of 194 participants. The sample was randomly split into validation (n=127) and test-retest reliability (n=99, 32 out of 127 participants also performed validity test) groups. 127 participants performed a graded exercise test (GXT, stationary gas analyser) and the 20 m PSRT (portable gas analyser) once to develop a VO2max prediction model and to analyze the validity of the modified 20 m PSRT protocol (starting at 7.5 km/h and increasing by 0.5 km/h every 1 min). 99 participants performed the 20 m PSRT twice for test-retest reliability purpose. Mean measured VO2max (39.2±5.1 ml/kg/min) from the potable gas analyzer was significantly increased from that measured during the GXT from stationary gas analyzer (37.7±5.7 ml/kg/min, p=.001) using the modified 20 m PSRT protocol. But it was a narrow range (1.5 ml/kg/min). The measured VO2max from the potable and stationary gas analyzers correlated at r=.88(p<.001). Test-retest of the 20 m PSRT yielded comparable results (Laps r=.88 & final speed r=.85). New regression equations were developed from present data to predict VO2max for middle-school girls: y=.231×Laps-.311×weight(in kg)+46.201 (r=.74, SEE=4.29 ml/kg/min). It is concluded that (a) the modified 20 m PSRT protocol is a valid and reliable test and (b) this equation developed in this study provides valid estimates of VO2max of Korean middle-school girl aged 13-15 years.

Explosion Hazards and Flame Velocity in Aluminum Powders (알루미늄 분체의 폭발위험성과 화염전파속도)

  • Han, Ou-Sup;Lee, Su-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.7-13
    • /
    • 2012
  • An experimental study has been done to investigate the explosion characteristics of aluminum powders with different sizes and concentrations in a 20 L spherical explosion vessel. Two different sizes of aluminum powder were used : $15.1{\mu}m$ and $34.8{\mu}m$ with a volume mean diameter. The results revealed that $15.1{\mu}m$ Al powder has a Lower explosion limit (LEL) of $40g/m^3$, a maximun explosion pressure ($P_{max}$) of 9.8 bar and a maximum rate of pressure rise ($[dP/dt]_{max}$) of 1852 bar/s, in $34.8{\mu}m$ Al powder, LEL of $70g/m^3$, $P_{max}$ of 7.9 bar and $[dP/dt]_{max}$ of 322 bar/s. The LEL of Al powders tended to increase with the increase of particle size. Also, it was found that the flame velocity calculated from the powder with $15.1{\mu}m$ was about 5 times higher than that of the powder of $34.8{\mu}m$.

Implementation of a Smart Antenna Base Station for mobile-WiMAX (Mobile-WiMAX를 위한 스마트 안테나 기지국 구현)

  • Lee, Chang-Hoon;Choi, Seung-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.1
    • /
    • pp.43-52
    • /
    • 2010
  • In this paper, the mobile-WiMAX (m-WiMAX) using the Smart antenna technique is implemented. Experiments are performed to compare Smart antenna system with conventional single antenna system. To implement the m-WiMAX smart antenna system there are many considerations, key issues of which are symbol time acquisition, beamforming, calibration. In the paper, symbol time acquisition, beamforming, calibration are implemented in WiMAX Smart antenna system and we verified that Smart antenna system is superior to single antenna system. The experimental results show 5.5 dB performance enhancement of implemented Smart antenna system in throughput compared with a single antenna system. The experimental result is almost same as theoretical result of 6 dB.

Respiratory Gas Exchange and Ventilatory Functions at Maximal Exercise (최대운동시의 호흡성 가스교환 및 환기기능)

  • Cho, Yong-Keun;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.900-912
    • /
    • 1995
  • Background: Although graded exercise stress tests are widely used for the evaluation of cardiorespiratory performance, normal standards on respiratory gas exchange and ventilatory functions at maximal exercise in Koreans have not been well established. The purpose of this study is to provide reference values on these by sex and age, along with derivation of some of their prediction equations. Method: Symptom-limited maximal exercise test was carried out by Bruce protocol in 1,000 healthy adults consisting of 603 males and 397 females, aged 20~66 years. Among them VC, $FEV_1$ and MVV were also determined in 885 cases. All the subjects were members of a health center, excluding athletes. During the exercise, subjects were allowed to hold on to front hand rail of the treadmill for safety purpose. Results: The $VO_2\;max/m^2$, $VCO_2\;max/m^2$ and $V_E\;max/m^2$ were greater in males than in females and decreased with age. The RR max in men and women was similar but decreased slightly with age. The $V_T$ max was markedly greater in men but showed no significant changes with age in either gender. The mean of $V_T$ max/VC, $V_E$ max/MVV and BR revealed that there were considerable ventilatory reserves at maximal exercise even in older females. The regression equations of the cardinal parameters obtained using exercise time(ET, min), age(A, yr), height(Ht, cm), weight(W, kg), sex(S, 0=male; 1=female), VC(L), $FEV_1$(L) and $V_E$ max(L) as variables are as follows: $VO_2\;max/m^2$(L/min)=1.449+0.073 ET-0.007A+0.010W-0.006Ht-0.209S, $VCO_2\;max/m^2$(L/min)=1.672+0.063ET-0.008A+0.010W-0.005Ht-0.319S, VE max/$m^2$(L/min)=58.161+1.503ET-0.315A-9.871S or VE max/$m^2$(L/min)=47.873+6.548 $FEV_1$-5.715 S, and VT max(L)=1.497+0.223VC-0.493S. Conclusion: Respiratory gas exchange and ventilatory variables at maximal exercise were studied in 1,000 non-athletes by Bruce protocol. During exercise, the subjects were allowed to hold on to hand rail of the treadmill for safety purpose. We feel that our results would provide ideal target values for patients and healthy individuals to be achieved, since our study subjects were members of a health center whose physical fitness levels were presumably higher than ordinary population.

  • PDF