• 제목/요약/키워드: $LSF_6$

검색결과 29건 처리시간 0.022초

$LSF_6$의 교류 밀 직류전압에 대한 절연특성연구 (The breakdown characteristics in $LSF_6$ for AC&DC voltage)

  • 최은혁;박광서;임창호;김이국;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.178-179
    • /
    • 2006
  • In this paper the experiments of breakdown characteristics SF6 liquid ($LSF_6$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, The ability of $LSF_6$ insulation is higher than high-pressurized SF6 gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery which will be studied and developed in the future.

  • PDF

Breakdown Characteristics of SF6 and Liquefied SF6 at Decreased Temperature

  • Choi, Eun-Hyeok;Kim, Ki-Chai;Lee, Kwang-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.765-771
    • /
    • 2012
  • $SF_6$ gas has been used as arc quenching and insulating medium for high and extra high voltage switching devices due to its high dielectric strength, its excellent arc-quenching capabilities, its high chemical stability and non toxicity. Despite of its significant contributions, the gas was classified as one of the greenhouse gas in the Kyoto Protocol. Thus, many researches are conducted to find out the replacement materials and to develop the $SF_6$ gas useless electrical equipment. This paper describes experiments on the temperature change-related breakdown characteristics of $SF_6$ gas ($SF_6$) and $SF_6$ liquid ($LSF_6$) in a model GIS(Gas-Insulated Switchgear) chamber in order to show the possibility of more stable and safe usages of $SF_6$ gas. The breakdown characteristics are classified into three stages, namely the gas stage of $SF_6$ according to Paschen's law, the coexisting stage of $SF_6$ gas with liquid in considerable deviation at lower temperature, and the stage of $LSF_6$ and remaining air. The result shows that the ability of the $LSF_6$ insulation is higher than the high-pressurized $SF_6$. Moreover, it reveals that the breakdown characteristics of $LSF_6$ are produced by bubble-formed $LSF_6$ evaporation and bubbles caused by high electric emission and the corona. In addition, the property of dielectric breakdown of $LSF_6$ is determined by electrode form, electrode arrangement, bubble formation and movement, arc extinguishing capacity of the media, difficulty in corona formation, and the distance between electrodes. The bubble formation and flow separation phenomena were identified for $LSF_6$. It provides fundamental data not only for $SF_6$ gas useless equipment but also for electric insulation design of high-temperature superconductor and cryogenic equipment machinery, which will be developed in future studies.

Breakdown Characteristics of SF6 in Different State and Bubble Movements under AC High-Voltage

  • Choi, Eun-Hyeok;Lim, Chang-Ho;Yoon, Dae-Hee;Park, Kwang-Seo;Kim, Lee-Kook;Lee, Kwang-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.257-262
    • /
    • 2007
  • In this paper the experiments of breakdown characteristics by temperature change of $SF_6$ gas($GSF_6$), and $SF_6$ liquid ($LSF_6$) in model GIS (Gas Insulated Switchgear) are described. From the experiment's results, the breakdown characteristics classify the vapor stage of $SF_6$ according to Paschen's law, in which the gas & liquid coexisted stage of voltage value increases, resulting in much deviation and the breakdown of voltage ($V_B$) low stage as the interior of the chamber gets filled with a mixture of $SF_6$ that is not liquefacted and remaining air that cannot be ventilated. The ability of $LSF_6$ insulation is higher than the high-pressurized $SF_6$ gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubbles caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery that will be studied and developed in the future.

액체 $SF_6$의 기포발생과 거동에 따른 절연파괴특성 (The Discharge Characteristics through the Bubble Production & Motion in Liquid $SF_6$)

  • 최은혁;최상태;박원주;김이국;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.39-43
    • /
    • 2007
  • In this paper the experiments of breakdown characteristics $SF_6$ liquid ($LSF_6$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, The ability of $LSF_6$ insulation is higher than high-pressurized $SF_6$ gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery which will be studied and developed in the future.

  • PDF

평등전계시 $SF_6$의 상변화에 따른 절연파괴특성 (Breakdown Characteristics about $SF_6$ in Different Slate under Uniform Fields)

  • 최은혁;박혜리;우성훈;장승호;김이국;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.261-264
    • /
    • 2008
  • In this paper the experiments of breakdown characteristics $SF_6$ liquid ($LSF_6$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, The ability of $LSF_6$ insulation is higher than high-pressurized $SF_6$ gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery which will be studied and developed in the future.

  • PDF

액체 $SF_6$의 전극별 기포유동현상과 절연파괴특성 (The discharge characteristics & Bubble Movement for various electrode shapes in Liquid $SF_6$)

  • 최은혁;임창호;장승호;김이국;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.252-253
    • /
    • 2007
  • In this paper the experiments of breakdown characteristics $SF_6$ liquid ($LSF_6$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, The ability of $LSF_6$ insulation is higher than high-pressurized $SF_6$ gas. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machinery which will be studied and developed in the future.

  • PDF

VoIP 손실 환경에 강인한 저지연 LSF FEC 기법 (Low-Delay LSF FEC Technique Robust in Lossy VoIP Environment)

  • 양해용;이경훈;황인호
    • 대한전자공학회논문지SP
    • /
    • 제39권6호
    • /
    • pp.687-695
    • /
    • 2002
  • VoIP 음성 패킷 손실에 대한 대응 방안으로 제시되고 있는 매체 종속 FEC 기법은 통화 품질을 개선시키는 효과를 갖는데 반하여 한 프레임에 해당하는 추가지연이 발생하는 단점을 갖는다. 본 논문에서는 패킷 손실 복원에 사용되는 잉여 정보로 미래 프레임의 LSF 성분을 사용함으로써, 전송 지연을 줄이고 통화 품질을 개선할 수 있는 LSF FEC 기법을 제안하고 그 성능을 평가한다. 성능 평가를 위해서 VoIP에서 사용하는 ITU-T G.723.1, G.729 코덱을 Gilbert 손실 모델에 적용하고, PESQ 음질 측정 알고리즘을 사용하여 각 손실률 별로 MOS를 추정하는 방법을 사용한다. 본 논문에서 제안한 기법은 기존의 매체 종속 FEC 기법에 비해서 6.5ms∼27ms 이상의 지연 감소 효과를 가지고 있는 것으로 나타났으며, FEC를 적용하지 않은 경우와의 복원 음성 품질 비교 시뮬레이션 결과, 5% 정도의 현실적인 손실 환경에서 MOS 0.1 이상의 음질 개선 효과를 보였다.

$SF_6$와 액체 질소의 절연파괴특성과 정기포현상 (The Positive Bubble Effect and the Breakdown Characteristics in $SF_6$ and $LN_2$)

  • 이광식;최은혁;박광서;김종환;임창호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권8호
    • /
    • pp.355-360
    • /
    • 2005
  • In this paper the experiments of breakdown characteristics by temperature change of $SF_6$ gas, $SF_6$ liquid ($LSF_6$) and $N_2$ liquid ($LN_2$) in model GIS(Gas Insulated Switchgear) were described. From the experiments results, the breakdown voltage of $SF_6$ increases with the drop of temperature and the increase of the inner pressure in model GIS. The ability of $LSF_6$ insulation is higher than high-pressurized $SF_6$ gas and $LN_2$. The breakdown characteristics of $LSF_6$ were produced by bubble formed evaporation of $LSF_6$ and bubble caused by high electric emission. It is considered in this paper that the results are fundamental data for electric insulation design of superconductor and cryogenic equipments machine교 which will be studied and developed in the future.

포만트 공간에서의 주파수 변환을 이용한 이중 언어 음성 변환 연구 (Bilingual Voice Conversion Using Frequency Warping on Formant Space)

  • 채의근;윤영선;정진만;은성배
    • 말소리와 음성과학
    • /
    • 제6권4호
    • /
    • pp.133-139
    • /
    • 2014
  • This paper describes several approaches to transform a speaker's individuality to another's individuality using frequency warping between bilingual formant frequencies on different language environments. The proposed methods are simple and intuitive voice conversion algorithms that do not use training data between different languages. The approaches find the warping function from source speaker's frequency to target speaker's frequency on formant space. The formant space comprises four representative monophthongs for each language. The warping functions can be represented by piecewise linear equations, inverse matrix. The used features are pure frequency components including magnitudes, phases, and line spectral frequencies (LSF). The experiments show that the LSF-based voice conversion methods give better performance than other methods.

슬래그를 클링커 혼합원료로 사용한 시멘트의 물리적 특성 (Physical Properties of Cement Using Slag as Raw Mix of Clinker)

  • 이영준;권도영;;추용식
    • 자원리싸이클링
    • /
    • 제33권3호
    • /
    • pp.12-20
    • /
    • 2024
  • 세계 시멘트 산업의 온실가스 배출량은 약 29억 톤이며, 이중 17.4~18.9억 톤이 시멘트 클링커의 주원료인 석회석으로부터 배출된다. 따라서 비탄산 CaO 원료인 슬래그류 사용이 연구되어야 하며, 이때 시멘트의 물리적 특성도 충분히 발현되어야 한다. 본 연구에서는 슬래그류 사용에 따른 혼합원료 배합 조건과 시멘트 물성을 분석하였다. 슬래그류 단독 사용 시 CaCO3 대체율은 한계를 갖으나, 혼합 슬래그 사용 시 CaCO3 대체율이 12 % 이상 증가하였다. 단독 슬래그 사용 시멘트의 압축강도는 OPC 대비 감소하였으며, 압축강도 증진을 위해 혼합원료의 LSF 및 시멘트 분말도를 상향시켰다. 분말도 상향 시멘트의 압축강도는 CaCO33 대체율 6 %까지 OPC와 유사하였으나, 9 % 이상에서는 소폭 하락하였다. 하지만 혼합 슬래그 사용 시멘트의 분말도와 LSF를 모두 상향 시, CaCO3 대체율 12 % 시멘트도 OPC와 유사한 압축강도가 발현되었다. 또한 CaCO3 대체율 12 % 시멘트의 플로우 값도 OPC와 유사하였다.