• 제목/요약/키워드: $K_0$-standardization

검색결과 435건 처리시간 0.024초

국내 재배산 익모초의 품질관리 연구 (Studies on Quality Control of Domestic Leonurus japonicus Houttuyn)

  • 한민우;박재성;곽이성;안희준;서정범;이영종;박채규
    • 한국약용작물학회지
    • /
    • 제24권6호
    • /
    • pp.451-457
    • /
    • 2016
  • Background: Leonurine is a the aerial part of Leonurus japonicus Houttuyn, which has been used as a traditional medicines and is registered in the Korean Pharmacopoeia. Methods and Results: In the present study we performed a heavy metals and thin layer chromatography and measured loss on drying, as well as the contents of total ash, acid-insoluble ash, ethanol soluble compounds, and leonurine, using 15 domestically collected L. japonicus samples. The methods were performed according to the 'crude drugs test of the general test, processes and apparatus', published by MFDS, Korea (2014). The purity test (heavy metals) indicated that levels of Pb and Hg were 0.35 - 3.64, and 0.001 ppm, respectively, whereas the levels of As and Cd were undetectable, and stachydrine was identified by thin layer chromatography ($R_f$ : 0.15). We found that 5.93 - 10.62% (average: $8.58{\pm}1.8%$) of the sample mass was lost during drying, and the contents of total ash, acid-insoluble ash, ethanol soluble compounds, and leonurine were 7.87 - 10.84% (average: $9.62{\pm}0.82%$), 0.99 - 1.76% (average: $1.38{\pm}0.24%$), 16.70 - 23.11% (average: $19.49{\pm}2.14%$) and 0.04 - 0.17% (average: $0.11{\pm}0.04%$) respectively. In addition, HPLC profiling detected leonurine (5.94 min), rutin (16.43 min) and myricetin (26.78 min). Conclusions: We hope that this the rusult of the present study will contribute to the standardization and quality control of Korean herbal medicines.

국내산 상지(桑枝)의 품질관리 연구 (Studies on quality control of domestic Morus alba Linne)

  • 박유미;백미은;이영종;원재희
    • 대한본초학회지
    • /
    • 제31권3호
    • /
    • pp.71-75
    • /
    • 2016
  • Objectives : Mori Ramulus is a young branch of Morus alba Linne, which has been used as traditional medicines for antidiarrhea, antibacteria, and antihypertension in Korea. With the basis on these medicinal activities, it is registered at the Korean Herbal Pharmacopoeia. The standard for quality control in use, however, is not yet validated.Methods : We experiment on heavy metals test, TLC, loss on drying, ash, acid-insoluble ash, contents of ethanolsoluble extracts and contents of oxyresveratrol by using the 15 samples of Mori Ramulus which are collected domestically. We tested items according to the General Test, processes and apparatus, Crude Drugs Test of KP(2011).Results : Purity test(Heavy metals) showed contents for Pb, As, Hg, and Cd range of 0.1~1.1 ppm, 0.0~0.2 ppm, 0.00~0.01 ppm, and 0.00~0.02 ppm. Identification test(Thin layer chromatography) was on comparing with morucine standard solution in Rf value, all samples showed morucine spot (dark blue, Rf : 0.3) as same as Rf value of morucine-standard solution. Loss on drying was ranged from 5.1 to 8.9 %, ash and acid-insoluble ash were between the range 3.0~6.3% and 0.3~0.8%. Contents of ethanol-soluble extracts was ranged from 6.2 to 12.0%. Content of oxyresveratrol was ranged from 0.01 to 0.16 % based on the oxyresveratrol standard curve.Conclusions : We sincerely hope that this study will be contributed to the standardization and quality control of Korean herbal medicines.

D.C. magnetron sputter를 이용한 Ag layer 건식 도금층의 특성 평가 국제 표준화에 대한 연구 (A Study on the standardize the characteristic evaluation of DC magnetron sputtered silver coatings for engineering purposes)

  • ;최진혁;임태관;정명준;이수완
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 추계학술대회 논문집
    • /
    • pp.249-249
    • /
    • 2015
  • Silver films have been of considerable interest for years due to their better performance relative to other metal films for engineering applications. A series of multi-layer silver coatings with different thickness (i.e. 0.3 um to 1.5 um) were prepared on Aluminium substrate containing copper undercoat by direct current (DC) magnetron sputtering method. For the comparative purpose, similar thickness silver coatings were prepared by electrolytic deposition method. Microstructural, morphological, and mechanical characteristics of the silver coatings were evaluated by means of scanning electron microscope (SEM), X-ray diffraction (XRD), Surface roughness test, microhardness test and nano-scratch test. From the results, it has been elucidated that the silver films prepared by DC magnetron sputtering method has superior properties in comparison to the wet coating method. On the other hand, DC magnetron sputtering method is relatively easier, faster, eco-friendly and more productive than the electrolytic deposition method that uses several kinds of hazardous chemicals for bath formulation. Therefore, a New Work Item Proposal (NWIP) for the test methods standardization of DC magnetron sputtered silver coatings has recently been proposed via KATS, Korea and a NP ballot is being progressed within a technical committee "ISO/TC107-metallic and other inorganic coating".

  • PDF

L2 Proficiency Effect on the Acoustic Cue-Weighting Pattern by Korean L2 Learners of English: Production and Perception of English Stops

  • Kong, Eun Jong;Yoon, In Hee
    • 말소리와 음성과학
    • /
    • 제5권4호
    • /
    • pp.81-90
    • /
    • 2013
  • This study explored how Korean L2 learners of English utilize multiple acoustic cues (VOT and F0) in perceiving and producing the English alveolar stop with a voicing contrast. Thirty-four 18-year-old high-school students participated in the study. Their English proficiency level was classified as either 'high' (HEP) or 'low' (LEP) according to high-school English level standardization. Thirty different synthesized syllables were presented in audio stimuli by combining a 6-step VOTs and a 5-step F0s. The listeners judged how close the audio stimulus was to /t/ or /d/ in L2 using a visual analogue scale. The L2 /d/ and /t/ productions collected from the 22 learners (12 HEP, 10 LEP) were acoustically analyzed by measuring VOT and F0 at the vowel onset. Results showed that LEP listeners attended to the F0 in the stimuli more sensitively than HEP listeners, suggesting that HEP listeners could inhibit less important acoustic dimensions better than LEP listeners in their L2 perception. The L2 production patterns also exhibited a group-difference between HEP and LEP in that HEP speakers utilized their VOT dimension (primary cue in L2) more effectively than LEP speakers. Taken together, the study showed that the relative cue-weighting strategies in L2 perception and production are closely related to the learner's L2 proficiency level in that more proficient learners had a better control of inhibiting and enhancing the relevant acoustic parameters.

빈혈환자에서 자동 ESR 기기인 Test 1과 Westergren법의 비교 (Comparative Evaluation of Erythrocyte Sedimentation Rate by the Test 1 Analyzer and Westergren method in Patients with Anemia)

  • 김일택;김종석;박연보;임재실
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.137-143
    • /
    • 2004
  • Erythrocyte sedimentation rate(ESR) measurements were performed in a total of 191 blood samples from patients below a hematocrit of 35% by both the Test-1(SIRE Analytical Systems, Udine, Italy) and the Westergren method, endorsed as the reference method for ESR by the International Council for Standardization in Hematology(ICSH). The corrected Westergren ESR values were also obtained applying the formula of Fabry (corrected ESR = ESR measured x 15/55-Hct). Linear regression analysis showed a close correlation (r=0.85) between the two methods both before and after ESR correction in total samples. There was no significant correlation difference between two methods in both two groups with hemoglobin $${\geq_-}9g/dl$$ and <9g/dl before and after ESR correction (r=0.873, r=0.827 respectively before correction and r=0.867, r=0.830 respectively after correction). Also, for two groups with hematocrit $${\geq_-}24%$$ and <24%, no significant difference was observed (r=0.859, r=0.792 respectively before correction and r=0.782, r=0.842 respectively after correction). However, for samples with <60mm of Westergren ESR before correction, a better correlation coefficient was obtained than samples with $${\geq_-}60mm$$(r=0.701, r=0.541 respectively). In corrected Westergren ESR, also samples that were obtained with <40mm showed better correlation than samples with $${\geq_-}40mm$$ (r=0.690, r=0.347 respectively). In conclusion, we found a good correlation between Test-1 and Westergren measurements in patients with anemia but an expert group discussion is required to solve discrepancy between two methods in blood samples with very high ESR.

  • PDF

환경준위 알파입자측정을 위한 다중선 비례계수기 개발(I) (Development of Multiwire Proportional Counter for Measurement of Environmental-level Alpha Particles)

  • 오필제;박태순;이민기;김경화
    • 분석과학
    • /
    • 제9권3호
    • /
    • pp.262-269
    • /
    • 1996
  • 저준위 및 환경준위의 알파입자 방출핵종의 방사능을 측정하기 위한 다중선 비례계수기를 개발하였다. 비례계수기의 외부 크기는 $350{\times}290{\times}30mm$이고, 측정이 가능한 측정선원의 최대 면적은 $250{\times}200mm$이다. 비례계수기의 재질은 최소의 background와 외부충격에 의한 형태변형을 방지하기 위해 스테인리스 스틸을 사용하였고, 양극선 및 음극선의 재질은 직경 $50{\mu}m$의 스테인리스 스틸 wire로서, 전체 전극선의 수는 각각 21개와 42개이다. 계수효율을 최대로 하고 검출기벽에 의한 흡수효과를 제거하기 위해서 측정선원은 검출기 내부에 위치하도록 하였으며, 선원두께에 의한 효율변화를 방지하기 위하여 선원 높이를 10mm까지 조절할 수 있도록 설계하였다. 제작된 검출기는 plateau, 작동전압, background, 계수효율, 선원위치에 따른 감도, 에너지분해능 등의 특성조사를 수행하였다. $^{241}Am$ 핵종의 경우, 시료 1L를 처리하여 50,000초를 측정하였을 때의 LLD(Lower Limit of Detection)는 5.0 mBq/L로 산출되어 ISO(International Organization for Standardization)에서 규정하고 있는 환경준위의 알파업자 측정용 장치의 LLD인 40mBq/L 보다 낮은 방사능을 분석할 수 있는 양호한 환경방사능 측정장치인 것으로 판명되었다.

  • PDF

연소 반응기를 이용한 브롬 및 염소의 함량 측정에 관한 연구 (Characterization of bromine and chlorine in the closed combustion system)

  • 최기인;권덕준;배성진;이동훈
    • 한국결정성장학회지
    • /
    • 제21권6호
    • /
    • pp.274-279
    • /
    • 2011
  • 연소 반응기를 이용하여 고분자 물질에 함유된 할로겐 원소인 브롬과 염소를 정량하기 위한 조건을 연구하였다. 염소농도 측정의 경우, Mohr법이나 전위차 적정법을 이용한 경우가 산-염기 적정법을 이용한 경우보다 분석 데이터 간 편차가 낮게 나타났다. 또한, 연소 반응기에서 단계별로 포집한 용액에 대한 염소와 브롬 측정 결과, 두 원소 모두 증류수를 흡수액으로 사용할 때, 0.3 M NaOH 수용액을 사용할 때보다 더 높은 회수율을 보였으며, 흡수액/세척액에서의 농도가 가스상의 형태로 배출되는 농도에 비해 높은 것으로 나타났다. 한편, 브롬 함량을 측정할 때, 연소 반응기를 이용한 경우가 XRF나 연소-이온크로마토그래피를 이용한 경우에 비해 농도가 상대적으로 낮게 평가되는 것으로 나타났다.

Ultra-low-latency services in 5G systems: A perspective from 3GPP standards

  • Jun, Sunmi;Kang, Yoohwa;Kim, Jaeho;Kim, Changki
    • ETRI Journal
    • /
    • 제42권5호
    • /
    • pp.721-733
    • /
    • 2020
  • Recently, there is an increasing demand for ultra-low-latency (ULL) services such as factory automation, autonomous driving, and telesurgery that must meet an end-to-end latency of less than 10 ms. Fifth-generation (5G) New Radio guarantees 0.5 ms one-way latency, so the feasibility of ULL services is higher than in previous mobile communications. However, this feasibility ensures performance at the radio access network level and requires an innovative 5G network architecture for end-to-end ULL across the entire 5G system. Hence, we survey in detailed two the 3rd Generation Partnership Party (3GPP) standardization activities to ensure low latency at network level. 3GPP standardizes mobile edge computing (MEC), a low-latency solution at the edge network, in Release 15/16 and is standardizing time-sensitive communication in Release 16/17 for interworking 5G systems and IEEE 802.1 time-sensitive networking (TSN), a next-generation industry technology for ensuring low/deterministic latency. We developed a 5G system based on 3GPP Release 15 to support MEC with a potential sub-10 ms end-to-end latency in the edge network. In the near future, to provide ULL services in the external network of a 5G system, we suggest a 5G-IEEE TSN interworking system based on 3GPP Release 16/17 that meets an end-to-end latency of 2 ms.

일체식 엑스선 간섭계를 이용한 나노미터 표준확립 (Establishment of nanometer length standardization using the monolithic x-ray interferometer)

  • 김원경;정용환;박진원;김재완;엄천일;권대갑
    • 한국결정학회:학술대회논문집
    • /
    • 한국결정학회 2002년도 정기총회 및 추계학술연구발표회
    • /
    • pp.35-35
    • /
    • 2002
  • 나노미터 표준을 확립하기 위하여 일체식 엑스선 간섭계에 광간섭계를 결합시킨 복합간섭계를 구성하였다. 복합간섭계는 광간섭계의 Zero crossing 지점부터 표준시편이 올려진 미소이동대의 이동거리를 변화된 위상값으로 읽고 그 변화량을 고분해능 변위 측정기인 엑스선 간섭계로 읽어들이는 구조로 구성된다. 본 연구에서는 미소이동대의 위치 변화와 관련된 광간섭계의 위상 안정도, 엑스선 간섭계 및 미소이동대의 위치 안정도 등이 나노미터 영역의 길이 측정에 매우 중요한 요인이 되므로, 미소이동대의 위치 변화시 정지상태에서의 위상 잠김 (phase locking) 안정도를 측정하였다. 마이켈슨 레이저간섭계의 한쪽 팔을 고정시키고 다른 한 팔은 미소이동대 위에 반사거울을 설치하여 미소이동대의 움직임을 측정하였다. 보다 안정된 위상잠김 상태를 확보하기 위하여 PID feedback loop controller를 사용하였다. 측정 결과 위상 변동폭이 0.022 degree 이하의 높은 위상잠김 안정도를 확보하였으며, 이를 길이단위로 환산하면 정지상태에서 약 0.02 nm 이하의 위치 안정도를 나타낸다.

  • PDF

External Application of Herbal Medicines for Acne Vulgaris: A Systematic Review and Meta Analysis

  • Sung, Soo-Hyun;Choi, Gwang-Ho;Lee, Nam-Woo;Shin, Byung-Cheul
    • 대한약침학회지
    • /
    • 제23권1호
    • /
    • pp.8-17
    • /
    • 2020
  • Aim of the study: The objective of this systematic review is to critically evaluate the evidence of the effectiveness and safety of external application of herbal medicines (EAHM) for acne vurgalis (AV). Methods: English, Chinese and Korean language databases were searched up to May 2018. Randomized clinical trials (RCTs) that reported the effects of EAHM for AV were included and analysed. Results: A total of 10 randomized trials with 656 AV patients were identified. A meta-analysis of two RCTs indicated that EAHM had a significant effect on improving primary outcome 'global assessment' compared with placebo (mean difference (MD) = -2.62, confidence interval (CI) = -4.84 to -0.40, p = 0.02). Furthermore, data extracted from two RCTs showed that EAHM significantly reduce primary outcome 'inflammatory lesion count of acne' (MD = -1.25, CI = -1.68 to -0.83, p < 0.00001) and 'non-inflammatory lesion count of acne' (MD = -1.32, CI = -1.75 to -0.90, p < 0.00001). No significant difference was observed between groups in secondary outcome 'sebum of skin' (MD = -0.21, CI = -0.53 to 0.11, p = 0.20) and 'patient-reported changes in symptom' (relative risk (RR) = 2.56, CI = 0.43 to 15.22, p = 0.30). No severe adverse events (AEs) were found and no treatment was stopped due to AEs of EAHM. Conclusions: EAHM seems to have affirmative effects, but quality of evidence, and non-standardized use of EAHM make our conclusion weak. Our suggestion is rigorously designed RCTs and standardization of EAHM are required in the future.