• Title/Summary/Keyword: $K_{\beta}$이탈률

Search Result 2, Processing Time 0.015 seconds

A Study on the Comparison of HPGe Detector Response Data for Low Energy Photons Using MCNP, EGS, and ITS Codes (MCNP, EGS, ITS코드를 이용한 고순도 게르마늄 검출기의 저에너지 광자에 대한 반응 비교연구)

  • Kim, Soon-Young;Kim, Jong-Kyung;Kim, Jong-Oh;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.2
    • /
    • pp.125-129
    • /
    • 1996
  • The energy response of HPGe detector for low energy Photons was determined by using three Monte Carlo codes. MCNP4A. EGS4, and CYLTRAN in ITS3. In this study. bare HPGe detector$(100 mm^2{\times}10mm)$ was used and a pencil beam was incident perpendicularly on the center of the detector surface. The photopeak efficiency, $K_{\alpha}$ and $K_{\beta}$ escape fractions were calculated as a function of incident X-ray energies ranging from 12 to 60 keV in 2-keV increments. Since the Compton. elastic. ana penetration fraction were negligible in this energy range. they were ignored in the calculation. Although MCNP. EGS, and CYLTRAN codes calculated slightly different energy response of HPGe detector for low energy Photons, it appears that the three Monte Carlo codes can Predict the low energy Photon scattering Processes accurately. The MCNP results, which are generally known as to be less accurate at low energy ranges than the EGS and ITS results. are comparable to the results of EGS and ITS and are applicable to the calculation of the low energy response data of a detector.

  • PDF

Thermoluminescence from X-Ray Irradiated Beta-Eucryptite (X-선 조사된 Beta-eucryptite의 열자극 발광)

  • 김태규;이병용;최범식;강현식;추성실;황정남
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.9-18
    • /
    • 1992
  • In this study, beta-eucryptite is fabricated and the thermal parameters of this material have been investigated. The thermoluminescence from 4MeV X-ray irradiated beta-eucryptite have been measured over the temperature range of 300K-600K. Thermoluminescence curve from X-ray irradiated beta-eucryptite shows five peaks located at 342K, 392K, 438K, 474K, and 527K. $\tau$, $\delta$ and $\omega$ of peak at 527K are 35K, 39K and 74K, respectively and this peak is found to be 2nd order kinetics. The activation energy of peak shape method is calculated to be 1.03eV and the frequency factor for 527K curve is calculated to be 3.9x10$\^$8/sec$\^$-1/. Based on the various heating rates methods, the activation energy of the peak is computed to be 1.02${\pm}$0.05eV that is similar to 1.19${\pm}$0.03eV of initial rise method. The linearity of thermoluminescence intensity and radiation flux is valid up to 50Gy and beyond higher dose the supralinearity and saturation come out.

  • PDF