• Title/Summary/Keyword: $H_2$ sensor

Search Result 1,048, Processing Time 0.032 seconds

Spectrum analysis of the FBG sensor signal and location determination of FBG sensor into the $H_2$ pressure vessel (해석적인 기법을 통한 FBG 센서의 스펙트럼 분석 및 수소고압용기의 센서 삽입위치 결정)

  • Park, S.O.;Kim, C.U.;Park, J.S.;Kim, C.G.
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.25-28
    • /
    • 2005
  • The optical fiber is known for the proper sensor which can accomplish the structural health monitoring, Fiber Bragg Grating sensors are being studied more than any other fiber optic sensors due to good multiplexing capabilities. But because the signal stability of FBG sensors can be influenced by the strain gradient, it needs to analyze signal of FBG sensors. Particularly acoording to strain gradient induced by structural geometry or cracks, the spectrum peak of the FBG sensor signal can be split easily. In this paper, the spectrum analysis of the FBG sensor signal was performed and the region of embedment of FBG sensors was determined in $H_2$ pressure vessel by numerical method.

  • PDF

High-Sensitive Fiber-Optic pH Sensor Using Neutral Red Immobilized in Porous Sol-Gel Film (뉴트럴레드가 고정화된 다공성 졸-겔 필름을 이용한 고감도 광섬유 pH 센서의 특성)

  • Jeon, Da-Yeong;Yoo, Wook-Jae;Shin, Sang-Hun;Han, Ki-Tek;Park, Jang-Yeon;Park, Byung-Gi;Cho, Seung-Hyun;Lee, Bong-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.223-228
    • /
    • 2012
  • In this study, a fiber-optic pH sensor based on a pH sol-gel film is fabricated. The sol-gel film is made by co-polymerizing tetramethoxysilane, trimethoxymethylsilane, ethanol and distilled water. As a pH indicator, a neutral red is immobilized in a thin porous film formed by the sol-gel process. The pH change in a sensing probe gives rise to a change in the color of the pH sol-gel film, and the absorbance of reflected light through the pH sol-gel film is also changed. By using a spectrometer, therefore, the spectra of reflected lights in the sensing probe with different pH values are measured. Also, the relationships between the pH values and the absorbance are analyzed on the basis of the color variations of the pH sol-gel films. In repeated experiments, the fiber-optic pH sensor shows that it has reversibility, a high reproducibility and a wide absorbance change in a pH range from pH 5 to 9. Also, we confirmed that the fabricated pH sol-gel film exhibits a fast response time, little or no pH indicator leaching and a dynamic range of 2.04 dB from pH 5 to 9. Based on the results of this study, a fiber-optic pH sensor can be developed for the pH monitoring in the harsh environments.

Fabrication and Characteristics of FET Type Semiconductor Urea and Glucose Sensor Employing Photolithography Techniques (사진식각기술을 이용한 FET형 반도체 요소 및 포도당센서의 제조와 그 특성)

  • Cho, Byung-Woog;Kim, Chang-Soo;Seo, Hwa-Il;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.2
    • /
    • pp.101-106
    • /
    • 1992
  • pH-ISFETs, the semiconductor pH sensors, were combined with immobilized enzyme membranes to prepare FET type urea and glucose sensors and its operational characteristics were investigated. Photolithography techniques were applied to immobilize enzymes on the $H^{+}$ sensing membrane of the pH-ISFET with photo-sensitive polymers, PVA-SbQ. Fabricated urea and glucose sensors could determine $0.5{\sim}50{\;}mg/dl$ urea concentrations and $10{\sim}1000{\;}mg/dl$ glucose concentrations, respectively.

  • PDF

Portable Soil pH Sensor Using ISFET Electrode

  • Hong, Youngsin;Chung, Sun-Ok;Park, Jongwon;Hong, Youngki
    • Journal of information and communication convergence engineering
    • /
    • v.20 no.1
    • /
    • pp.49-57
    • /
    • 2022
  • Fertilizers have long been used to increase crop yields; however, farmers are still having difficulties in managing fertilizers for growing crops as well as economic problems. The conventional method of soil sampling and laboratory analysis to determine soil pH is time consuming and costly; therefore, a portable pH sensor is developed to characterize spatial or temporal variability within fields via rapid and dense data acquisition. The portable pH sensor comprises an electrode unit, a portable console, and a USB connector. The soil water content (SWC) and electrical conductivity (EC) affect the electrical resistance of soil. An artificial test soil is performed to evaluate the effect of SWC and EC on soil pH. The test results show that stable pH measurements are achieved at SWCs greater than 20 mL (16.3%). Regardless of the SWC, the electric potential difference (EPD) remains at 2.5 g of NaCl. As the EC increases in the soil samples, the EPD increases.

Signal processing of multichannel FET type electrolyte sensors using neural network (신경회로망을 이용한 다중채널 FET형 전해질 센서의 신호처리)

  • 이정민;이창수;손병기;이은석;이흥락
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.11
    • /
    • pp.148-155
    • /
    • 1997
  • Ths signal processing technqiue of FET type electrolyte sensors using the back propagation neural network was studied to reduce the interference effects of the different electrolytes. The FET-type electrolyte sensors, pH-ISFET, K-ISFET, and Ca-ISFET, were prepared to measure the pH, K, and Ca electrolytes. Neural network consisted of three layers was learned with 8 patterns and 9 patterns. The sensor output obtained with arbitrary concentrations was processed by the learned neural network. The errors obtained from calibration curve for pH, K, and Ca were .+-.0.039 pH, .+-.2.508 mmol/l, and .+-.1.807 mmol/l, respectively, without considering the interference effects. The errors of the network output for pH, K, and Ca were reduced to .+-.0.005 pH, .+-.0.436 mmol/l, and .+-.0.381 mmol/l in case of 9 patterns, respectively. the signal processing using the neural network can reduce the errors ofthe electrolyte sensor outputs caused by the interference effect, thereby providing effectiveness in the improvement of the sensor selectivity.

  • PDF

The Studies for the Malate Tissue Biosensor Using Malate Dehydrogenase(Decarboxylating) in the Bundle Sheath Cell of the Corn Leaf (옥수수잎의 유관속초세포내에 들어 있는 Malate Dehydrogenase(Decarboxylating)을 이용한 Malate 측정용 조직바이오센서에 관한 연구)

  • 김의락;노광수
    • KSBB Journal
    • /
    • v.9 no.3
    • /
    • pp.319-324
    • /
    • 1994
  • A biosensor for the measurement of malate has been constructed by the sodium-alginate immobilized bundle sheath cell tissue of corn leaf containing malate dehydrogenase (decarboxylating) (EC 1. 1. 1. 40) on the CO2 gas-sensing electrode. The proposed tissue sensor had the linear in the range of malate concentration $5.5{\times}10^{-5}M∼2.5{\times}10^{-2}M$ with a slope of 53.5 mV/decade in 0.02M Tris-HCl buffer solution at optimum pH 8.0, and $25^{\circ}C$. A response time was 16∼18min. The present L-malate sensing tissue sensor is stable for more than one week. At pH 7.4, Km value was $0.6{\times}10^{-5}M$. The various kinds of salt did not effect the signal of malate tissue biosensor as the inhibitor. We can measure the malate by the CO2 electrode at the pH=8.0. Thus, the proposed tissue sensor will be useful for the measurement of malate.

  • PDF

Fabrication of CO2 Sensor Membrane by Photolithographic Method (사진식각법을 이용한 CO2 센서 감지막의 제조)

  • Park, Lee Soon;Kim, Sang Tae;Koh, Kwang-Nak
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.6-12
    • /
    • 1998
  • A FET(Field Effect Transistor) type dissolved $CO_2$ sensor based on Severinghaus type $CO_2$ sensor was fabricated by the photolithographic process. The sensor consists of Ag/AgCl reference electrode and membranes (hydrogel membrane and $CO_2$ gas permeable membrane) on the pH-ISFET base chip. Ag/AgCl reference electrode was fabricated as follows. Ag layer was thermally evaporated and then its upper surface was chemically chloridized into the AgCl. The hydrogel used as an internal electrolyte solution was fabricated by a photolithographic method using 2-hydroxyethyl methacrylate(HEMA) and acrylamide. $CO_2$ permeable membrane on the top of the hydrogel layer was formed by photolithographic process with UV-oligomer. The FET type $pCO_2$ sensor fabricated by photolithographic method showed good linearity within the concentration range of $10^{-3}{\sim}10^0mole/{\ell}$ of dissolved $CO_2$ in aqueous solution with high sensitivity.

  • PDF

Preparation of the Citrobacter freundii Bio-Sensor for the Determination of Glucose and Its Applications (Glucose 정량을 위한 Citrobacter freundii Bio-Sensor의 개발과 그 응용)

  • Ihn Gwon-Shik;Hong Young-Seuk;Kim Ui-Rak;Jang Seh-Yong;Sohn Moo-Jeong
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.5
    • /
    • pp.424-429
    • /
    • 1990
  • A bio-sensor for the determination of glucose has been constructed by immobilizing the Citrobacter freundii or its organelle on carbon dioxide gas-sensor. The bacterial sensor was better than organelle in response, but the latter showed a shorter response time. The bacterial sensor gave linearity between 7.0 ${\times}\;10^{-4}$ and 1.0 ${\times}\;10^{-2}$ M glucose with a slope of 42.2 mV/decade in pH 7.0, 0.2 M tris-HCl buffer at 30$^{\circ}C$. The selectivity of this sensor was very high for glucose. Employing for the determination of glucose in serum, the sensor showed a good agreement with a routine analyzer.

  • PDF

Preparation of a New $K^{+}-ISFET$ Modified with 4'-Aminobenzo-15-crown-5 and Its Response Characteristics (4'-Aminobenzo-15-crown-5를 수식한 새로운 $K^{+}-ISFET$의 제조와 감응특성)

  • Lee, H.L.;Yun, J.H.;Yang, S.T.;Jung, D.S.;Sohn, B.K.
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.85-92
    • /
    • 1992
  • A new potassium sensitive field effect transistor modified with 4'-aminobenzo-15-crown-5 was prepared and its response characteristics were evaluated. The response slope of $K^{+}-ISFET$ for pH was 30.0 mV/decade and the response time was mere than 3 minutes. And the response slope and time of the $K^{+}-ISFET$ for potassium ion as $19.5{\pm}0.2{\;}mV/decade$ and about 3 minutes, respectively. The linear response range of the sensor for potassium ion was $2.0{\times}10^{-4}{\sim}1.0{\times}10^{-2}M$. The selectivity coefficients of the $K^{+}-ISFET$ for the alkali and alkaline earth metal ions were also evaluated. Sodium, ammonium and calcium ions exhibited relatively significant interference. The long term stability of the sensor was remarkably improved and it could be used for more than 50 days.

  • PDF