• Title/Summary/Keyword: $GB_{34}$

Search Result 161, Processing Time 0.03 seconds

1-Gb/s Readout Amplifier Array for Panoramic Scan LADAR Systems (파노라믹 스캔 라이다용 1-Gb/s 리드아웃 증폭기 어레이)

  • Kim, Dayeong;Park, Sung Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.452-456
    • /
    • 2016
  • In this paper, a dual-channel readout amplifier array is realized in a standard $0.18{\mu}m$ CMOS technology for the applications of panoramic scan LADAR systems. Each channel consists of a PIN photodiode with 0.9 A/W responsivity and a 1.0 Gb/s readout amplifier(ROA). The proposed ROA shares the basic configuration of the previously reported feedforward TIA, except that it exploits a replica input to exclude a low pass filter(LPF), thus reducing chip area and improving integration level, and to efficiently reject common-mode noises. Measured results demonstrate that each channel achieves $70dB{\Omega}$ transimpedance gain, 829 MHz bandwidth, -22 dBm sensitivity for $10^{-9}BER$, -34 dB crosstalk between adjacent channels, and 45 mW power dissipation from a single 1.8 V supply.

Effects of acupuncture on bone mineral density in ovariectomized rats (자극(刺鍼)이 난소(卵巢)를 절제(切除)한 흰쥐의 골밀도(骨密度)에 미치는 영향(影響))

  • Kim Mi-Ryeo;Yang Chae-Ha
    • Journal of Acupuncture Research
    • /
    • v.15 no.2
    • /
    • pp.279-285
    • /
    • 1998
  • Effects of acupuncture at Sanyinjiao(SP6) and Yanglingquan(GB34) on bone mineral sensity(BMD) was investigated in ovariectomized(OVX) rats. BMD of OVX rats was measured left femur and tibia 2 and 4 weeks after acupuncture stimulation, respectively. Compared with sham-operated rats, a significant decrease in spine, pelvic and left femoral and tibial BMD was observed 2 and 4 weeks after OVX, respectively. In contrast, a significant increase of spinal, pelvic and left femoral and tibial BMD was elicited 2 and/or 4 weeks after acupuncture stimulation, respectively. These results show the possibility that acupuncture can play a role of ameliorating osteoporosis by elevating serum levels of female hormones related with bone metabolism.

  • PDF

Acupuncture Stimulation for Motor Cortex Activities: Evidence from 3T Functional MRI Study

  • Choe, Bo-Young;Kang, Sei-Kwon;Chul, Myung-Ja;Jeun, Sin-Soo;Yoo, Seung-Schik;Park, Gi-Soon;Park, Sang-Dong;Lim, Eun-Chul;Chung, Sung-Taek
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.132-132
    • /
    • 2002
  • Purpose: To investigate whether or not acupuncture of GB34 produces a significant response of the modulation of somatomotor areas by functional magnetic resonance imaging (fMRI) study. The acupoint, GB34, located in the back of the knee, is known to be effective in recovering motor function after stroke.

  • PDF

Synthesis of Cyclic Peticdes Related to GBⅠ-Ⅱand Study of Their Inhibitory Activity for Proteinases (GBⅠ-Ⅱ 와 관련된 Cyclic Peptide 들의 합성과 단백질 분해 효소에 대한 저해활성 연구)

  • Gang, Sin Won;Heo, Nam Won
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.288-296
    • /
    • 1990
  • Antielastic fragment in GBⅠ-Ⅱ differ on $P_1$ site with that of antitryptic fragment in LBI. To obtain further understanding of the role of amino acid residue near the reactive site, specificity of $P_1$ site and loop size, Tyr substituted cyclic nonapeptide and cyclic pentapeptide were synthesized and the inhibition constants for some proteinases were calculated by Dixon method. Cyclic nonapeptide showed no inhibition for chymotrypsin but appeared low inhibitory activity for trypsin and elastase and that of cyclic pentapeptide possessed inhibitory activity for chymotrypsin.

  • PDF

Effects of Electroacupuncture on the Regulation of Chemokine Induced Spinal Activation of Microglia in the Rat Model of Neuropathic Pain (흰쥐 신경병증성 통증 모델에서 전침이 케모카인이 유도하는 척수 교세포 활성화 조절에 미치는 영향)

  • Sindhuri, Vishnumolakala;Lee, Ji Eun;Park, Hye-Ji;Kim, So-Hee;Koo, Sungtae
    • Korean Journal of Acupuncture
    • /
    • v.36 no.4
    • /
    • pp.264-273
    • /
    • 2019
  • Objectives : Microglia play a crucial role in electroacupuncture (EA) analgesia on neuropathic pain. The role of chemokines in producing analgesic effects of EA, however, is largely unknown. In the present study, we investigated the role of chemokines in producing analgesic effects of EA in the neuropathic pain model. Methods : Sprague-Dawley rats were randomly assigned into three groups (anesthetized group (ANE), non-acupoint EA group (NAP), and ST36 - GB34 EA group (ACU)). Neuropathic pain was induced by tight ligation of L5 spinal nerve. Mechanical and thermal hypersensitivity of hind paw was tested. Western blot tests and immunofluorescence assay for C-C motif chemokine ligand 2 (CCL2) levels and microglia activation were performed on spinal cord L5/6. EA was treated once daily from the 3rd day after surgery for 5 days. Results : EA treatments applied to ST36 and GB34 significantly reduced both mechanical and thermal hypersensitivity after two and three times of treatment, respectively. While CCL2 expression significantly increased in neuropathic rats, it was significantly reduced in the ACU. In addition, co-localization of CCL2 and activated microglia significantly decreased in the ACU compared to those of ANE and NAP in the spinal cord L5/L6 dorsal horn. Conclusions : The present results suggest that EA applied to ST36 and GB34 modulates the reduction of CCL2 release from the injured neurons and consequently decreases microglia activation in the spinal cord. Regulation of chemokine induced spinal activation of microglia plays a key role in analgesic effects of EA in the rat model of neuropathic pain.

Research for the Construction of Six Command Points (육총혈에 배속되는 경혈에 관한 연구)

  • Kwon, Sunoh;Seo, Byung-Kwan;Kim, Seungtae
    • Korean Journal of Acupuncture
    • /
    • v.33 no.2
    • /
    • pp.47-57
    • /
    • 2016
  • Objectives : Six command points are individual points that have strong and broad effects on their related part of the body, but there is a controversy about which acupoints are should be included in the six command points. This research was reviewed which acupoints are suitable for the construction of the six command points. Methods : We searched acupoints mentioned six command points in literatures, then investigated the effects of the acupoints to identify that they can be included in the six command points. And we deliberated which acupoints are suitable for the six command points. Results : Acupoints mentioned the six command points are LU7, LI4, ST36, BL40, PC6, TE6, GV26, ouch point, GB34 and SP6. Among the acupoints, LU7, LI4, ST36, BL40 and PC6 was included in the six command points in all of searched literatures. And GV26, ouch point, GB34 and SP6 were excluded because GV26 and ouch point were not fit the definition of the six command points, ST36 can be an alternative to SP6 based on their effects, and GB34 has a similar but little effect compared to TE6. Conclusions : Based on the definition of six command points and the effect of the acupoints, we suggest that the six command points should be composed of LU7, LI4, ST36, BL40, PC6 and TE6.

Differential Expression of microRNAs Following Electroacupuncture Applied to ST36 and GB34 in Rat Models of Chronic Pain (족삼리 양릉천 전침 자극 후 흰쥐 통증 모델에서 microRNA의 차등 발현)

  • So-Hee, Kim;Vishnumolakala, Sindhuri;Sungtae, Koo
    • Korean Journal of Acupuncture
    • /
    • v.39 no.4
    • /
    • pp.132-141
    • /
    • 2022
  • Objectives : Some acupoints are commonly utilized to treat a variety of diseases. The acupoints appear to have a wide range of effects caused by several mechanisms. The purpose of this study is to investigate into the potential role of microRNAs (miRNAs) in the multipotent effects of individual acupoint stimulation. Methods : We examined the miRNA expressions in the dorsal root ganglia (DRG) of neuropathic or inflammatory pain rats following ST36 and GB34 electroacupuncture (EA) stimulation. Neuropathic pain was induced by L5 spinal nerve ligation. Inflammatory pain was induced by knee joint injection of Complete Freund's adjuvant (CFA). EA was given under gaseous anesthesia with the same parameters (1mA, 2Hz, 30 min) in 5 consecutive days. Pain behaviors and miRNA expressions were analyzed. Results : In rats with neuropathic and inflammatory pain, EA treatments significantly enhanced the paw withdrawal threshold and weight-bearing force. After nerve injury, 36 miRNAs were upregulated in the DRG of neuropathic rats, while EA downregulated 10 of them. Furthermore, 14 miRNAs were downregulated following nerve damage, while one was increased by EA. 15 miRNAs were increased in the DRG of inflammatory rats following CFA injection, while 5 were downregulated by EA. Furthermore, 17 miRNAs were downregulated following CFA injection, while 7 were increased by EA. The miRNAs rno-miR-335, rno-miR-381-5p, rno-miR-1306-3p, and rno-miR-1839-3p were regulated by EA in both models. Conclusions : In two pain models, EA applied to ST36 and GB34 regulated miRNA expression differently. There appeared to be both acupoint-specific and non-specific miRNAs, and miRNA regulation of differential protein expression may modulate a variety of EA mechanisms.

Estimation of Genetic Parameters for Economic Traits in Korean Native Chicken Using Multiple Trait Animal Model (다형질 Animal Model에 의한 한국재래계의 주요 경제형질의 유전모수 추정)

  • 상병돈;최철환;김학규;나재천;김상호;송치은;정행기;상병찬;한성욱
    • Korean Journal of Poultry Science
    • /
    • v.27 no.1
    • /
    • pp.51-61
    • /
    • 2000
  • This study was conducted to estimate the general production performance, heritabilities, and genetic phenotypic correlations on several economic traits by multiple trait animal model in Korean native chicken. The data were collected from the records of 5,192 pullets produced from 2,029 dams and 250 sires in Daejon Branch, National Livestock Research Institute from April 10. 1994 to February 10. 1997. Body weights of Red Brown (RB), Yellow Brown (YB), Grey Brown (GB) and Black (B) strains were 1,649.9, 1,439.6, 1,455.6 and 1,575.3g at age of 150 days and 1,923.5, 1,689.6, 1,812.4 and 1,924.0g at age of 270 days, respectively. The ranges of coefficient of variation for body weight were 11.52 to 14.02 at age of 150 days and 12.82 to 14.59% at age of 270 days, respectively. The first eggs of RB, YB, GB and B strains were produced at 147.4, 146.5, 151.1 and 152.1 days, respectively and the coefficients of variation were 7.80 to 8.41%. Egg weight at 270 days were 49.7, 47.6, 48.8 and 48.7 g for RB, YB, GB nd B strains, and coefficients of variation were 6.99 to 7.94% . The number of eggs at age of 270days were 75.8, 78.0, 76.7 and 68.8 for RB, YB, GB and B strains, respectively, and coefficient of variations were 23.87 to 29.89%. On heritability estimates in RB, YB, GB and strains body weight were 0.40, 0.10, 0.09 and 0.57 for RB, YB, GB and B strains at age of 150 days, and 0.23, 0.09, 0.38 and 0.24 at age of 270 days were 0.39, 0.47, 0.60 and 0.62, and egg weights at 270 days and age at 1st egg were 0.36, 0.12, 0.38 and 0.26, number of egg production at 270 days were 0.44, 0.36, 0.58 and 0.49, respectively. The genetic correlation coefficients of body weight with the age of first egg, egg weight and number of egg production at 270days were -0.07∼0.67, -0.24∼0.70 and 0.12∼0.41, respectively ; age of first egg with number of egg production at 270days and egg weight were -0.75∼0.91 and 0.34∼0.97 ; and egg weight with number of egg production at 270days were 0.18∼0.68. The phenotypic correlation coefficients of body weight with at age of first egg, egg weight and number of egg production at 270days were -0.01∼0.74, -0.04∼0.72 and 0.25∼0.57 ; age of first egg with number of egg production at 270days and egg weight were 0.26∼0.52 and 0.52∼0.92, respectively ; and egg weight with number of egg production at 270days were 0.34∼0.91.

  • PDF

Change of Refractive Index of Air in X-band due to Atmospheric Humidity, Temperature and Pressure measured by GB-SAR Interferometry (GB-SAR 간섭기법으로 측정된 X-밴드 대기 굴절률의 상대습도, 기온 및 기압에 따른 변화)

  • Lee, Jae-Hee;Lee, Hoon-Yol;Cho, Seong-Jun;Sung, Nak-Hoon;Kim, Kwang-Eun
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.2
    • /
    • pp.163-170
    • /
    • 2011
  • In this paper, we analyzed the phase change of 5-triangular trihedral comer reflectors by using X-band Ground-Based Synthetic Aperture Radar (GB-SAR) system. Each reflector was set as a stationary target at a different distance from the system. We obtained total 123 full-polarization images during 40 hours continuously at 20 minute interval. Results of SAR interferometric analysis showed phase changes of maximum 2 radians and followed similar pattern with atmospheric data. Through a GB-SAR phase formula that includes refractive index in the air, we performed regression analysis for refractive index as a function of atmospheric humidity, temperature and pressure. As a result, refractive index of air in X-band showed relatively high coefficient of determination with humidity and temperature (0.72 and 0.76 on average, respectively) but not so with pressure (0.34). The refractive index of air in X -band changed by 3.14\;{\times}\;10^{-5}$ during the measuring time with a humidity range of 50% ~ 90% and a temperature range of $-1^{\circ}C$ ~ $9^{\circ}C$. We expect that a total expression of refractive index of air including humidity, temperature and pressure can be calculated when more extensive data would be collected at various atmospheric conditions.

THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES ON PRIMARY AND PERMANENT TEETH (유치와 영구치에서 치과용 접착제의 전단결합강도)

  • Choi, Jin-Young;Choi, Nam-Ki;Park, Yeong-Joon;Choi, Choong-Ho;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.4
    • /
    • pp.579-589
    • /
    • 2007
  • The objective of this study was to compare the shear bond strengths of five adhesive systems to the enamel and dentin of primary and permanent teeth. Fifty noncarious primary and fifty permanent teeth were collected and stored in an 0.1% thymol solution at room temperature after extraction. The tested adhesives were: Adper Scotchbond Multi-purpose Plus Adhesive (SM) Adper Single bond 2 (SB), Clearfil SE Bond (SE), Adper Prompt L-Pop (PL), GBond (GB). For the shear bonding test, the labial and lingual surfaces of primary and permanent teeth were used. To obtain a flat surface, the labial and lingual surfaces of the teeth were sanded on $SiO_2$ with number 600 grit and then divided into 20 groups of 10 surfaces each. All samples were theromocycled in water $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles. The results were as follows: 1. For primary enamel, shear bond strengths of SM and SB were significantly higher than that of SE and also SM, SB, and PL were higher than GB(p<0.05). 2. For primary dentin, there were no significant differences among the shear bond strengths of any other bonding systems except difference between SE and GB. 3. For permanent enamel, SB showed significantly higher mean shear bond strength than those of any other bonding systems(p<0.05). 4. For permanent dentin, SM showed significantly higher mean shear bond strength than that of PL and GB(p<0.05). 5. Between the primary enamel and dentin, there were significant differences in SM, SB, and GB, whereas there was statistically significant difference in PL between the permanent enamel and dentin(p<0.05). 6. Between the primary and permanent teeth on enamel, there were no significant differences among all bonding systems, whereas there were statistically significant differences in SM and SB between the primary and permanent teeth on dentin(p<0.05).

  • PDF