• 제목/요약/키워드: $FT_1$

검색결과 2,196건 처리시간 0.032초

건강한 한국인 성인의 혈청 갑상선호르몬 참고치 (Reference Interval of Serum Thyroid Hormones in Healthy Korean Adults)

  • 장윤영;김창윤;황태윤;김경동;이채훈
    • Journal of Preventive Medicine and Public Health
    • /
    • 제41권2호
    • /
    • pp.128-134
    • /
    • 2008
  • Objectives : This study was conducted to determine the reference interval of serum thyroid hormones(TSH, $FT_3$, $FT_4$) in healthy Korean adults. Methods : Health examination data from 1,591 healthy Korean adults who visited an university hospital were analyzed. Patients with specific health conditions capable of altering laboratory results were excluded from the study. Serum thyroid hormones were measured using IMMULITE 2000 (DPC, USA, 2002). Subjects were 18-65 years old; 911 were male, and 690 were female. Results : The arithmetic means of TSH, $FT_3$, and $FT_4$ values for male subjects were $1.28{\pm}1.84\;{\mu}IU/ml$, $3.23{\pm}0.57\;pg/ml$, and $1.42{\pm}0.22\;ng/dl$, respectively. In female subjects, the arithmetic means of TSH, FT3, and FT4 values were $1.49{\pm}2.08\;{\mu}IU/ml$, $3.08{\pm}0.54\;pg/ml$, and $1.29{\pm}0.24\;ng/dl$, respectively. The arithmetic mean $FT_4$ value for males decreased with age (p<0.01). The arithmetic mean $FT_3$ value for females increased with age (p<0.01). The arithmetic mean thyroid hormone values of all study subjects differed significantly based on season. The arithmetic mean of male $FT_4$ decreased with increasing BMI (p<0.01). The arithmetic mean of female $FT_3$ increased with increasing BMI (p<0.01). The reference intervals recommended by the IMMULITE 2000 manufacturer are $0.40-4.00\;{\mu}IU/ml$ for TSH, 1.80-4.20 pg/ml for $FT_3$, and 0.80-1.90 ng/dl for $FT_4$ (same values for both genders). Conclusions : There was a significant difference in the interval of thyroid hormones between males and females, but the reference interval of IMMULITE 2000 was not established by gender. There is a need to reestablish the reference interval for thyroid hormones in Korean healthy adults.

세라믹 정밀여과에 의한 고도정수처리 시스템에서 물 역세척 시간 및 주기의 영향 (Effect of Water-back-flushing Time and Period in Advanced Water Treatment System by Ceramic Microfiltration)

  • 박진용;이혁찬;조재형
    • 멤브레인
    • /
    • 제18권1호
    • /
    • pp.26-34
    • /
    • 2008
  • 본 연구에서 처리수를 이용한 주기적인 역세척은 세라믹 정밀여과에 의한 고도정수처리 시스템에서 막오염을 저감하고 투과선속을 향상시키고자 수행되었으며, 물 역세척 주기(FT) 및 시간(BT)의 영향과 최적 운전조건을 규명하고자 하였다. FT의 영향을 알아보기 위해 일정한 BT 3초에서 FT를 $30{\sim}120$초로 변화시켰고, BT 영향 실험에서 일정한 FT 120초에서 BT를 $3{\sim}12$초로 변화시켰다. 그리고 다른 운전변수인 막간압력차는 1.52 bar, 물 역세척 압력 0.98 bar, 유입유량 0.5 L/min, 공급액의 온도 $20^{\circ}C$로 일정하게 유지하였다. 그 결과, 일정한 BT 3초에서 본 실험 범위의 최적 FT는 30초로, 이것은 빈번한 역세척이 막오염의 저감에 더 효과적임을 의미한다. 그러나 너무 짧은 BT로 인하여 FT의 영향은 크지 않았다. 한편, 일정한 FT 120초에서 BT가 증가함에 따라 막오염에 의한 저항($R_f$)은 감소하고 투과선속(J)과 무차원화한 투과선속 ($J/J_o$)은 증가하는 경향을 나타내어, 최대 BT인 12초에서 가장 많은 총여과부피($V_T$)를 얻을 수 있었다.

FT의 빠른 신뢰도 계산을 위한 연구

  • 이광원;이일재
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 1997년도 춘계 학술논문발표회
    • /
    • pp.95-109
    • /
    • 1997
  • 보통 시스템은 신뢰도 계산을 위하여 graph나 fault tree(FT)등으로 그 시스템의 신뢰도 특성을 표현하게 된다. 전산망이나 교통망등은 보통 하나의 부품이 graph의 한선에 1:1로 대응하는 linear graph로 표현되나 화학공장이나 원자력 발전소의 신뢰성 분석을 위하여 쓰이는 FT는 보통 하나의 부품 또는 사건이 여러 곳에서 나타나는 non linear graph이다. (중략)

  • PDF

능동소나 linear frequency modulation 신호의 fractional Fourier transform 분석에 기반한 표적의 거리 추정 (Estimation of target distance based on fractional Fourier transform analysis of active sonar linear frequency modulation signals)

  • 형성웅;박명호;황수복;배건성
    • 한국음향학회지
    • /
    • 제35권1호
    • /
    • pp.8-15
    • /
    • 2016
  • Fractional 푸리에 변환(Fractional Fourier Transform : FrFT)은 기존의 푸리에 변환의 일반화된 형태로서, 변환차수 ${\alpha}$에 따라 임의의 시간-주파수 영역에서의 신호해석이 가능하다. FrFT는 특히 LFM(Linear Frequency Modulation) 신호의 분석에 있어 잡음에 강한 특성으로 인해 많은 장점을 가진다. 본 논문에서는 능동소나에서 표적에 맞고 반향된 수신신호의 FrFT 스펙트럼으로부터 표적과의 거리를 추정하는 새로운 방법을 제안하였다. 합성한 표적 신호를 통해 제안한 방법의 타당성을 검증하였으며, 실제 수중 실험을 통해 얻은 잡음 및 잔향 환경에서의 신호에서도 신뢰성 있는 표적과의 거리 추정이 가능함을 확인하였다.

FT-IR Spectroscopic Study of Preparation of Lead Zirconium Titanate (PZT) by Sol-Gel Processing

  • 오영재;황인욱;심인보;김용록
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권6호
    • /
    • pp.588-594
    • /
    • 1997
  • Gelation time, gel structure and volatility of by-products during gelation of PZT sol-gel processing were investigated by FT-IR spectroscopy. FT-IR spectroscopic study was performed on PZT gels with the various H₂O contents (1, 2 and 3 mol) and the several types (HNO₃, NH₄OH) and amounts (0.1, 0.2 mol) of catalysts, monitoring temporal (0, 1, 3, 10 weeks, 3 months and 3 years) and thermal (100-700 ℃) changes of FT-IR spectra. The interpretation of temporal change of the spectra revealed two trends. One is under the condition of 1 mol H₂O, 1 mol H₂O+0.1 mol HNO₃, 3 mol H₂O and the other is for 1 mol H₂O+0.1 mol NH₄OH, 2 mol H₂O, 1 mol H₂O+0.2 mol HNO₃. The gel structures and the gelation times for these conditions were discussed in comparison with the reported results of SiO₂, and we suggested the reaction mechanisms for these structural characteristics. Thermal variation of FT-IR spectra was interpreted as the evolution processes of gel by investigating the evaporation of solvent and the decomposition of organic residues.

방사면역측정법(放射免疫測定法)에 의한 혈중(血中) 유리(遊離) Thyroxine 농도측정(濃度測定)의 임상적(臨床的) 의의(意義)에 대(對)한 검토(檢討) (Studies on the Clinical Significance of Free Thyroxine Concentration in Serum by Radioimmunoassay)

  • 이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제11권1호
    • /
    • pp.25-31
    • /
    • 1988
  • Studies on the clinical significance with Amerlex $FT_{4}$ RIA kit observing the determination of $FT_{4}$ were investigated using a tracer as $^{125}I-T_{4}$ derivative which is not almostly bound to thyroxine binding globulin, etc. The results are followed; 1. $FT_{4}$ value($1,55{\pm}0.38ng/100ml$) of normal group was not accorded that of hyperthyroidism with Amerlex $FT_{4}$ RIA kit, and was higher than that of hypothyroidism. 2. $FT_{4}$ value was lower level in chronic-kidney disfunction syndrome whereas, it was normal in a cancer patient, a woman in pregnancy and a patient in TBG disfunction. 3. The value of this method is a good corelationship at that of equilibrium dialysis method. (r=0.931) 4. $FT_{4}$ value by this kit was linear relationship to those of the other kit (Gamma Coat and Liquisol), and the normal value of each methods was also similar. As mentioned above, this method is more simple and rapid, compared to the other method. Therefore, it was thought that this method is a very useful clinically.

  • PDF

담수 및 해수사육 감성돔, Acanthopagrus schlegeli의 생리활성과 성장에 미치는 갑상선 호르몬의 효과 (Effects of Oral Administration of Thyroid Hormone on Physiological Activity and Growth of Black Porgy Reared in Freshwater or Seawater)

  • 민병화;노경언;정민환;강덕영;최철영;방인철;장영진
    • 한국양식학회지
    • /
    • 제19권3호
    • /
    • pp.149-156
    • /
    • 2006
  • 본 연구에서는 담수 및 해수사육 감성돔을 대상으로 $T_3$가 처리된 사료(10 mg/kg사료)를 90일간 공급하면서 어체의 스트레스, 삼투압조절 및 성장을 조사하였다. 혈장 $T_3$ 농도는 60일째에 FN, FT이 SN, ST에 비해 낮았으며, 또한 FN은 FT보다 유의하게 낮았다. 혈장 cortisol은 60일째를 제외하고는 실험구 사이에서 차이가 없었다 60일째에 FT $(21.0{\pm}3.3ng/ml)$$FN(5.1{\pm}1.4ng/ml)$보다 4배정도 높았으며, 또한 유의한 차이는 인정되지 않았지만 ST가 SN에 비해 다소 높은 것으로 나타났다. FN, FT의 혈장 glucose는 실험기간동안 SN, ST에 비해 낮은 경향을 보였으나, 담수 및 해수사육 감성돔에서 호르몬 처리에 의한 차이는 나타나지 않았다. 해수사육 감성돔의 AST 및 ALT는 실험기간동안 차이가 없었으나, 실험개시시 FN, FT의 AST및 ALT는 SN, ST보다 높았다. 또한 FN, FT의 AST의 해수수준으로 회복은 각각 실험종료시와 30일째에 해수수준으로 나타나 호르몬을 처리한 FT가 더 빨랐다. 그러나, 담수 및 해수사육 감성돔의 삼투압조절 향상 및 성장촉진을 위한 외인성 $T_3$ 공급 효과는 나타나지 않았다.

분무 열분해법을 이용해 제조된 VOx/Mesoporous Titania 상에서 1,2-dichlorobenzene의 분해반응에 대한 in situ FT-IR 연구 (In situ FT-IR Study of 1,2-dichlorobenzene Decomposition over VOx/Mesoporous Titania by Prepared Spray Pyrolysis)

  • 전종기;정경열;박영권
    • 공업화학
    • /
    • 제22권5호
    • /
    • pp.582-585
    • /
    • 2011
  • 본 연구에서는 분무 열분해 방법으로 제조된 메조기공 $V_2O_5/TiO_2$ 촉매 상에서 1,2-dichlorobenzene (1,2-DCB)의 표면 활성종을 파악하고자 하였다. 이를 위하여 in situ FT-IR cell을 이용하여 1,2-DCB의 흡착/탈착을 수행하였다. 또한 기존의 $TiO_2$와 incipient wetness로 제조된 $V_2O_5/TiO_2$ 상의 흡착종들과의 비교도 함께 수행되었다.

만성요통환자의 레이져 수술전과 수술6주후의 요부신전근력에 관한 비교 (The comparison about lumbar extensor strength between pre op group and post op(after 6 weeks) group in HIVD patient)

  • 박성광;석혜경;김명준
    • 대한물리치료과학회지
    • /
    • 제7권1호
    • /
    • pp.353-365
    • /
    • 2000
  • The purpose of this study were to compare the lumbar extensor strength between pre op patients group and after 6 weeks post op patients group. To evaluate lumbar extensor strength of total 273 patients with HIVD. Lumbar extensor strength was measured in 151 male patients and 122 female patients(Lumbar extensor strength was measured in 91 PELD patients group and 182 OLM group patients) by Medx lumbar extension machine. Maximum voluntary lumbar extension strength was appear $149.36{\pm}61.92ft$-lbs in pre op of PELD group, $158.47{\pm}54.67ft$-lbs in post op of PELD group and $135.54{\pm}54.24ft$-lbs in pre op of OLM group. $147.19{\pm}52.42ft$-lbs in post op of OLM group in male. Maximum voluntary lumbar extension strength was appear $83.85{\pm}30.22ft$-lbs in pre op of PELD group. $92.99{\pm}28.66ft$-lbs in post op of PELD group and $75.16{\pm}24.98ft$-lbs in pre op of OLM group, $79.88{\pm}25.25ft$-lbs in post op of OLM group in female. Male and female lumbar extension strength was statistically significant difference(P<.05). Lumbar flexion/extension ratio of the two group was 2.14:1 pre op and 2.05:1 post op in lumbar flexion 72 and 0 degree. The ratio of post op group was lesser than pre op group.

  • PDF

FT-IR을 이용한 계면활성제 혼합물의 정량 (A quantitative determination of surfactant mixtures by FT-IR)

  • 최종근;노경원
    • 대한화장품학회지
    • /
    • 제21권2호
    • /
    • pp.129-139
    • /
    • 1995
  • FT-IR의 정량 법 중 Partial least-squares(PLS) 방법과 Multiple scattering correction(MSC) 방법을 이용한 계면활성제 분석의 타당성을 조사하기 위하여 LAS, MES 그리고 ELA-9을 이들 방법으로 정량 하였다. 계면활성제 표준품을 각각 다른 비율로, 50% 에탄올에 가열 용해 시킨 다음, 건조 시켜 액막법으로 IR 스펙트럼을 측정하였다. 얻어진 스펙트럼으로부터 Variance(분산 ) 스펙트럼을 구하고 이를 참고하여 여러 파수 영역에서 반복하여 검량선을 작성하고 상관계수를 구하였다. 1245-1130 cm -1 의 범위와 1070-1010 cm -1 범위의 파수를 선정한 결과 상관계수의 값이 모두 1.000이었다. 또한 정량 결과, 오차가 0.32%이하로써 매우 만족할 만한 결과를 얻었다. 따라서 FT-IR을 이용한 정량 법에서 PLS 방법과 MSC 방법은 계면활성제 분석에 유효하며, 본 정량 방법이 매우 간단하므로 품질관리 목적의 분석에 적합하다는 결론에 도달하였다.

  • PDF