• Title/Summary/Keyword: $E_2/E_3$ ratio

Search Result 2,471, Processing Time 0.038 seconds

Evaluation of cardiac function by tissue Doppler imaging in children with cancer (Tissue Doppler imaging을 이용한 소아 종양 환자에서의 심기능 평가)

  • Kim, Yeo Hyang
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.4
    • /
    • pp.417-423
    • /
    • 2006
  • Purpose : The objectives of this study were to assess ventricular function by tissue Doppler imaging in children who were receiving chemotherapy or who had received chemotherapy, and to apply repeated tissue Doppler imaging to make an early assessment in cardiac toxicity studies. Methods : This study was conducted on 23 oncology patients on-treatment or off-treatment from April 2005 to July 2005 at Dongsan Medical Center, Keimyung University. All patients(group 1) were divided into two groups, fractional shortening(FS) over 29 percent(group 2) and FS under 28 percent (group 3) in the first category. These same patients were also divided into the following groups : group treated with anthracyclin(group 4) and group treated without anthracyclin(group 5). Deceleration time(DT), isovolumic relaxation time(IVRT), FS, peak early diastolic(E), and peak late diastolic (A) velocity of transmitral flow were measured by M-mode and pulsed wave Doppler. Systolic(Sm), peak early diastolic(Em), and peak late diastolic(Am) velocity in apical 4-chamber and 2-chamber views were measured by tissue Doppler imaging. The author calculated a modified Tei index, E/A, E/Em ratio by using measured values. Results : Twenty three patients were enrolled : 12 boys and 11 girls. The average age of patients was 8 years and 4 months. Thirteen out of 23 patients were in the group treated with anthracyclin (group 4) and 6 had FS under 28 percent(group 3). E/Em ratio showed a significant difference between group 1 and control group($6.46{\pm}1.85$ vs $7.06{\pm}1.64$, P<0.05). Other parameters had no difference statistically. Conclusion : This study showed that the change of cardiac function developed earlier in diastolic function than in systolic function, as E/Em ratio reflecting the mean LV diastolic pressure showed a significant difference between the control group and chemotherapy groups. Echocardiography using tissue Doppler imaging is a non-invasive, comfortable and reliable method for post-chemotherapy follow up.

Unconfined Compressive Strength Characteristics of Eco-Friendly Stabilizers and Carbon Fiber Reinforced Soil (친환경고화재와 탄소섬유 보강토의 일축압축강도 특성)

  • Sewook Oh;Sunghwan Yang;Hongseok Kim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.8
    • /
    • pp.13-19
    • /
    • 2024
  • In this study, to reinforce the surface layer of weathered soil slopes where erosion and collapse of surface layer occur, compression strength tests were conducted by mixing carbon fiber and eco-friendly stabilizer (E.S.B.) To determine the optimal mixing ratio of E.S.B. and carbon fiber, E.S.B. was set at conditions of 10%, 20%, and 30%, and carbon fiber at 0.3%, 0.6%, 0.9%, and 1.2%. Additionally, to analyze the changes in compressive strength according to dry density and curing period, 85% and 95% of the maximum dry unit weight were applied, and curing periods were set to 3 days, 7 days, and 28 days. The standard strength for surface layer reinforcement of slopes is proposed as 4 MPa at 7 days and 6 MPa at 28 days according to ACI 230.1R-09 (2009). The compression test results showed that the unconfined compressive strength of E.S.B. reinforced soil met the standard strength at an E.S.B. mixing ratio of 10% or more for 95% compaction. Moreover, when carbon fiber was mixed with E.S.B. reinforced soil, a ductile fracture pattern was observed after the yield point due to compressive strength, indicating that the mixture could compensate for post-yield failure. It was analyzed that the maximum strength is exhibited at a carbon fiber mixing ratio of 0.6%. The unconfined compressive strength of carbon fiber reinforced soil increases by approximately 54-70% compared to the condition without carbon fiber.

Spectral CT Analysis of Hounsfield Unit (HU) according to MonoE (keV) and Dilution Ratio of the Contrast Agent: Use of Spectral CT (단색에너지(keV)와 조영제 희석비율 변화에 따른 HU(Hounsfield Unit)값 분석: Spectral CT 이용)

  • Jung, Hee-Ra;Kang, Jin-woo;Kwon, Oh-Jun;Kim, Ho-Jin;Jung, Dabin;Lee, Jae-Hyun;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.669-676
    • /
    • 2020
  • The purpose of this study was to analyze the changes in the values of Hounsfield Unit (HU) according to the changes in monoenergy (keV) and dilution ratio of the contrast agent, using the spectral CT. Spectral CT was used as the testing device, while 20 cc syringe phantom was used to set a total of six dilution ratios of the contrast agent: 8:2, 7:3, 6:4, 5:5, 4:6, and 3:7. Here, the non-ionic iodine solution (350 mg/ml) was used as a contrast agent. The syringe axial image was reconstructed by adjusting the obtained data on nine MonoE levels; 40 keV, 45 keV, 50 keV, 55 keV, 60 keV, 65 keV, 70 keV, 75 keV, and 80 keV. The HU values were measured at the three points of the reconstructed syringe axial image. The measurements were taken 1,620 times in total. In the analysis of the HU values according to the changes in keV and dilution ratio of the contrast agent, the highest and lowest HU values were obtained from dilution ratio 8:2 and dilution ratio 3:7, respectively, across every MonoE in the comparison of HU according to dilution ratio per MonoE (p<0.05), while the highest and lowest HU values were obtained from 40 keV and 80 keV, respectively, across all dilution ratios in the comparison of HU according to MonoE per dilution ratio (p<0.05). For the correlation per each parameter, a negative correlation of -15.014 ± 0.298 was found for HU per keV (R2=0.519) and a negative correlation of -61.372 ± 3.608 was found for HU per dilution ratio (R2=0.152) (p<0.05). To conclude, an increase in keV or dilution ratio of the contrast agent was shown to decrease the HU, and the findings in this study are anticipated to serve as the basic data in the research of HU-related parameters in Spectral CT.

Conditions for Moire Free Contact-Type 3 Dimensional Displays

  • Song, Yoon-Chul;Saveljev, Vladimir V.;Son, Jung-Young;Yeom, Seok-Won;Vashpanov, Yu. A.
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.93-97
    • /
    • 2008
  • The superposing angle of the viewing zone forming optics and the display panel in the contact type 3 dimensional imaging systems for minimizing $moir{\acute{e}}s$ is found for a rectangular shape pixel with different aspect ratios. The angles are $26.2609^{\circ}$ for square shape pixels and $13.9858^{\circ}$ for the rectangular with aspect ratio 2. These angles result in the $moir{\acute{e}}s$ with the smallest period for the respective aspect ratio. The effectiveness of the angles is also experimentally demonstrated.

Post-pillars design for safe exploitation at Trepça hard rock mine (Kosovo) based on numerical modeling

  • Ibishi, Gzim;Genis, Melih;Yavuz, Mahmut
    • Geomechanics and Engineering
    • /
    • v.28 no.5
    • /
    • pp.463-475
    • /
    • 2022
  • In the mine exploitation stage; one of the critical issues is the stability assessment of post-pillars. The instability of post-pillars leads to serious safety hazards in mining operations. The focus of this study is to assess the stability of post-pillars in the 130# stope in the central ore body at Trepça hard rock mine by employing both conventional (i.e., critical span curve) and numerical methods (i.e., FLAC3D). Moreover, a new numerical based index (i.e., Pillar Yield Ratio-PYR) was proposed. The aim of PYR index is to determine a border line between stable, potentially unstable, and failure state of post-pillars at a specific mine site. The critical value of pillar width to height ratio is 2.5 for deep production stopes (e.g., > 800 m). Results showed that pillar size, mining height and mining depth significantly have affected the post-pillar stability. The reliability of numerical based index (i.e., PYR) is verified based on empirical underground pillar stability graph developed by Lunder, 1994. The proposed pillar yield ratio index and pillar stability graph can be used as a design tool in new mining areas at Trepça hard rock mine and for other situations with similar geotechnical conditions.

The effect of powder A2/powder A3 mixing ratio on color and translucency parameters of dental porcelain

  • Lee, Wan-Sun;Kim, So-Yeon;Kim, Ji-Hwan;Kim, Woong-Chul;Kim, Hae-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.400-405
    • /
    • 2015
  • PURPOSE. The purpose of this study is to mix dental ceramic powder in varying ratios and evaluate the effect of the mixing ratio on color and translucency. MATERIALS AND METHODS. The ceramic powder of shade A3 of the same product was mixed with the shade A2 of three products: IPS e.max Ceram (Ivoclar Vivadent, Schaan, Liechtenstein), Vintage Halo (SHOFU Inc., Kyoto, Japan), and Ceramco 3 (Ceramco-Dentsply, Burlington, NJ, USA) in the following fixed ratios (0 wt%, 25 wt%, 50 wt%, 75 wt%, and 100 wt%) and then fired. A total of 150 specimen of ceramic fired were manufactured in a regular size (W: 8.5 mm, L: 10.5 mm, and H: 1.5 mm). For color and translucency, $L^*$, $a^*$, and $b^*$ were measured and Two-way analysis of variance (ANOVA) and One-way analysis of variance (ANOVA) were used for data analysis (${\alpha}$=0.05). RESULTS. The higher the mixing ratio was, $L^*$, $a^*$, and $b^*$ of IPS e.max Ceram were all increased, and $L^*$ of Vintage Halo was reduced and $a^*$ and $b^*$ were increased. $L^*$ and $a^*$ of Ceramco3 were reduced and $b^*$ of Ceramco3 was increased. Color difference (${\Delta}E^*ab$) was increased in all three products as the mixing ratio got higher. Increased mixing ratios resulted in decreased translucency parameter (TP) values for IPS e.max Ceram but increased TP values for Vintage Halo and Ceramco3. CONCLUSION. In this limited study, CIE $L^*$, $a^*$, and $b^*$ were influenced by the mixing ratio of the A3 powders and porcelain powder mixtures represented a various color and translucency.

The Hydrolysis of Soybean Oil by Lipase Enzyme Catalyst (Lipase 효소촉매에 의한 대두유의 가수분해)

  • Lee, Jeong-Tae;Kim, Eui-Yong
    • KSBB Journal
    • /
    • v.23 no.6
    • /
    • pp.509-512
    • /
    • 2008
  • The hydrolysis reaction of soybean oil was conducted experimentally by various source enzymes. The analytical result of hydrolysate of soybean oil showed that the compositions were linoleic acid, olic acid, palmitic acid, and stearic acid in order. The enzymes CR-E and CC-E from Candida rufosa and Candida cylindracea had two hold or more hydrolysis conversions than those of Lipase 16, Novozyme 871, and Lipolase-100L under the same conditions. Therefore CR-E and CC-E were selected for further experiments. These two enzymes had similar ranges of optimun conditions as follows: pH 3-6, $35-45^{\circ}C$, and water to soybean oil ratio of 3.3 or above. They finally got conversions 95% above.

The electrical and optical properties of Cd$_{0.96}$Ze$_{0.04}$Te thin films (Cd$_{0.96}$Ze$_{0.04}$Te 박막의 전기 광학적 특성)

  • 김선옥;현준원
    • Journal of Surface Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.389-392
    • /
    • 1998
  • We have investigated the crystal properties of the Cd0.96Zn0.04Te(CZT) films evaporated on the Si(100) substrates by Elecctron Beam Evaporator(EBE) techique. The compositions of the As-preared films were different about 4% of atomic ratio, The films stucture was observad to be polycrystalline in cubic phase. Diffraction peaks were notable at the substrate temperature of $300^{\circ}C$. The reflectance measurements yield $E_1$=3.25~3.29 eV $E_1$+${\Delta}_1$=3.76~3.83 eV and $E_2$=5.08 eV,showing that the films wear in cubic phase. For the film evaporated at the substrate temperature of $150^{\circ}C$, the peaks of photocurrent are at 720nm and 980nm.

  • PDF

Association of apolipoprotein E polymorphisms with serum lipid profiles in obese adolescent (비만아에서 고지혈증과 Apolipoprotein E 다형성의 관계)

  • Yoon, Jung Min;Lim, Jae Woo;Cheon, Eun Jung;Ko, Kyoung Og
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.1
    • /
    • pp.42-46
    • /
    • 2008
  • Purpose : Apolipoprotein E (Apo E) plays a major role in lipoprotein metabolism and lipid transport. Many investigators have described that Apo E polymorphisms is one of the most important genetic determinants for cardiovascular disease. The purpose of this study was to evaluate the association between Apo E polymorphisms and serum lipid profiles in obese adolescent. Methods : We measured the serum concentrations of glucose, apolipoprotein (Apo) A1, Apo B, total cholesterol (TC), triglyceride (TG), HDL and LDL-cholesterol after overnight fasting in obese adolescent. Apo E polymorphisms were determined by polymerase chain reaction-restriction fragment length polymorphism (PCR-RFLP). Results : 86 obese adolescents participated in this study. The body mass index (BMI) of participants were excess of 95 percentile by age and sex. Male to female ratio was 1.7 and mean age of study group was $16.2{\pm}1.8\;years$. Mean BMI was $27.4{\pm}2.5kg/m^2$. The frequency of ${\varepsilon}2$, ${\varepsilon}3$ and ${\varepsilon}4$ allele were 8.1%, 87.2% and 4.7% respectively. Study populations were classified into the following three genotypes 1) Apo E2 group (n=13, 15.1%) carrying either the ${\varepsilon}2/{\varepsilon}2$ or ${\varepsilon}2/{\varepsilon}3$ 2) Apo E3 group (n=65, 75.6%) carrying the most frequent ${\varepsilon}3/{\varepsilon}3$ 3) Apo E4 group (n=8, 9.3%) carrying either the ${\varepsilon}3/{\varepsilon}4$ or ${\varepsilon}4/{\varepsilon}4$. No differences were found among Apo E genotypes concerning age, sex, weight, height and BMI. Apo B and LDL-cholesterol concentrations were significantly higher in the Apo E4 group (P<0.05). No association were found between Apo E genotypes and glucose, Apo A1, TC, TG and HDL. Conclusions : We confirmed that serum concentrations Apo B and LDL-cholesterol were influenced by Apo E genotypes. Apo E polymorphisms seems to influence some alteration of lipid metabolism associated with obesity in adolescent.

ON THE CATCH OF GILL NET IN THE JEJU ISLAND -Comparison of mackerel catch in monofilament and multifilament gill nets- (제주도 자망이망율에 관하여 -고등어 자망의 이망율 비교-)

  • SHON Tae Jun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.1
    • /
    • pp.7-10
    • /
    • 1975
  • The catches of mackerel by monofilament and multifilament net were compared by means of $x^2$ and t-test method. In order to improve the netting twine of drift nets, 6 shoots 5 different mesh and nylon-monofilament netting twines $(B\times2,\;C\;D,\;F,)$ and 2 shoe nylon-multifilament $(A\times2)$ which are using near the Jeju Island in contemporary days were used for the experiment. These gill no were connected in order of A, ,B, C, A, B, E, F and operated fly fishing boat Taeann Ho (7T) near sea of Jeju Ialand from May 1974 to August 1974. The results obtained are as follows: 1. B type nylon-monofilament gill nets were superior to nylon-multifilament gill nets in catch according to the result of $X^2$ test and t-test, and the catch ratio was $M_A:\;M_B=1:1.8$. 2. 75mm mesh size C, D nylon-monofilament gill nets were superior to 85mm mesh size nylonmonofilament gill nets, and their catch ratio were E, F: C, D=1:2.8. 3. The catch ratio C, D and E, F type nets were compared by means of t-teat, however could not recognized their relationship.

  • PDF