• 제목/요약/키워드: $ER\

검색결과 2,490건 처리시간 0.03초

ER댐퍼의 동특성 해석 및 성능연구

  • 이육형;박명관
    • 한국정밀공학회지
    • /
    • 제17권3호
    • /
    • pp.39-46
    • /
    • 2000
  • In this paper, the analysis of dynamic characteristics and performance investigation of the ER damper are investigated. The ER damper is based on a double rod actuator and an electric field are applied to the moving electrode composed of cylinder and piston. The performance of the ER damper is length of piston electrode field and its velocities. The experimental and calculated results show that the characteristic of the ER damper varies with the magnitude of the electric field.

  • PDF

ER인서트를 이용한 Hull Mount에서의 진동저감에 관한 연구 (Vibration reduction in a Hull mount using the ER inserts)

  • Kim, Ji-Seon;Kim, Jae-Hwan;Park, Seung-Bok;Kim, Kung-Su
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.348.1-348
    • /
    • 2002
  • This paper deals with the vibration reduction of the hull mount system of ship structures brought by ER smart structures. The hull mount is used to isolate the vibration form the immersed structures. Utilizing the tunable characteristics of ER fluids, ER insert are made In the hull mountint structure. Different types of ER inserts are proposed and the vibration characteristics are investigated. (omitted)

  • PDF

청국장에 존재하는 Isoflavone의 Mass분석 (Mass Analysis of Isoflavones in Chungkookjang)

  • 유형재;황재성;김한복
    • 미생물학회지
    • /
    • 제43권1호
    • /
    • pp.54-58
    • /
    • 2007
  • 청국장은 미생물, 효소, 다양한 생리활성물질을 포함하는 대두발효식품으로 정장, 핼액순환개선 효과 등이 알려져 있다. 청국장에 존재하는 isoflavone이 유방암, 전립선암의 억제와 관련이 있을 수 있다. 본 연구에서는 HPLC와 Mass 분석을 통해 분말청국장 100% ethanol추출물에 aglycone 형태의genistein, daidzein, glyciten이 존재함을 확인했다. 당이 붙어 있는 genistin, daidzin, OH기가 추가적으로 붙어 있는 8-OH-genistein, 8-OH-daidzein은 존재하지 않았다. Estrogen 수용체에는 $ER{\alpha},ER{\beta}$가 있다. $ER{\alpha}$는 유방암, 전립선암의 촉진에, $ER{\beta}$는 이들 암의 억제와 관련이 있을 것으로 추정한다. 인간의 estrogen 수용체가 cloning되어 있는 효모의 전사촉진 assay를 이용하여, 청국장에 있는 isoflavone이 $ER{\beta}_{1}$를 선택적으로 자극할 수 있음을 확인했다.

유압제어시스템 적용을 위한 ER 밸브의 내구성 평가 (Durability Evaluation of ER Fluids in Hydraulic Control Systems)

  • 김도태;장성철
    • 한국공작기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.100-105
    • /
    • 2007
  • Electro-rheological(ER) fluid and valve are fabricated and evaluated experimentally in its durability to utilize the hydraulic control systems for long term operation. The two-ports ER valve used in the experiment consist of twelve parallel multi-layer electrodes and provide a restriction to the passage of ER fluid because of the viscous pressure drop and a component induced by the electric field. The durability test of ER valve are performed by measuring the surface roughness of electrodes with variation of an electric field strength and test time(1000 or 1800min.). Also, the shear stress and shear rate are measured to evaluate the durability of ER fluid as function of time. After durability test, ER shear stress increases approximately proportional to the shear rate with applied electric field intensity, In the ER valve, the center line average height roughness(Ra) of copper electrode increases about 1.56 times and ten-point median height roughness(Rz) increases about 2.2 times after the durability test. An understanding of these durability is essential to predicting the service life of ER fluid and valves.

인산 에스테르 반응 셀룰로오스 미립자의 활성화가 비수계 ER 유체의 전기유변학적 특성에 미치는 영향 (The Effect of the Activation of Phosphoric Ester Cellulose Particles on the Electrotheological Properties of Anhydrous ER Fluids)

  • 안병길;최웅수;권오관;문탁진
    • Tribology and Lubricants
    • /
    • 제14권3호
    • /
    • pp.7-16
    • /
    • 1998
  • The electrorheological (ER) behavior of suspensions in silicone oil of phosphoric ester cellulose powder (average particle size: 17.77 $\mu$m) was investigated at room temperature with electric fields up to 2.5 KV/mm. For development of anhydrous ER suspensions using at wide temperature range, we aimed to know the effect of activation of phosphoric ester cellulose particles on the ER activities. As a first step, the anhydrous ER suspensions mixing with the phosphoric ester cellulose particles which were treated with 2M phosporic acid and 4M urea were measured. After activating the anhydrous ER suspensions at 12$0^{\circ}C$, not only the analysis of dispersing cellulose particles which were reacted by phosphoric ester but also the electrorheological characteristics of ER suspensions such as dielectric constant, current density, electrical conductivity and rheological properties were studied. From the experimental results, the activation of phosphoric ester cellulose particles had an influence on the ER properties of anhydrous ER suspensions. As the activation time went by, the size and number of dispersing particles, the electrical properties and the initial apparent viscosity $(η_0)$ of ER suspensions were increased till the activation time passed 5 hours. Also, it was possible, the electrorheological effect $($\tau$/$\tau$_0)$ of ER fluids was grown by the activation of phosphoric ester cellulose particles.

지능형 공정제어 시스템 적용을 위한 ER 작동기의 진동제어 특성에 관한 연구 (Study on the Vibration Control Characteristics of ER Actuator for Application in Intelligence Process Control Systems(PLC))

  • 장성철
    • 한국기계가공학회지
    • /
    • 제4권1호
    • /
    • pp.49-55
    • /
    • 2005
  • This paper presents experiments on the evaluation of characteristics of ER fluids used for vibration control of application in intelligence type process control systems. Dynamic characteristics of the actuator(beam) embedded with the ER fluid can be controlled by changing the strength of the electric field applied on the ER fluids, thus provides a mean to avoid the resonance. In case electric field is supplied to the smart structure with ER fluids, vibration energy is dissipated more than the beam without electric field, because particles in ER fluid form a chain structure in the presence of electric field. The damping and stiffness of the beam with ER fluid are increased when the applied electric field increases. The characteristics of damping and stiffness of the ER fluid with various electric field strength were investigated by conducting a vibration test of the beam with ER fluid. If it applies characteristics of the ER fluids, it will be able to apply in the PLC control system for the vibration which occurs from process system.

  • PDF

ER 유체를 이용한 반능동 현가장치용 고전압 전원장치의 개발 (Development of High Voltage Power Supply for Semi-Active Suspension System Using ER Fluids)

  • 정세교;신휘범
    • 전력전자학회논문지
    • /
    • 제7권5호
    • /
    • pp.453-464
    • /
    • 2002
  • ER 유체(Electrorheological fluid)는 인가 전계에 따라 유체의 점도(Viscosity)와 댐핑력(Damping force)이 변화하는 혼합물질이며 반능동 현가장치, 고속 클러치, 진동 흡수장치 등에 적용되고 있다. ER 유체의 응용을 위해서는 강한 전계를 인가해 줄 수 있는 고전압 가변 전원장치가 필요하다. 본 논문에서는 반능동 현가장치에 적용하기 위한 전원장치의 개발에 대하여 기술하였다. ER 유체의 전기적 특성, 고전압 전원장치의 요구조건, 전원장치의 설계 및 제작에 대하여 설명하였으며 최종적으로 실험을 통하여 개발된 고전압 전원장치가 ER 유체 응용에 적합함을 검증하였다.

Regulation of Estrogen Receptor Under Hypoxia in Breast Cancer Cells

  • Lee, Young-Joo
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 2008년도 Proceedings of the Convention
    • /
    • pp.55-74
    • /
    • 2008
  • Previously, we have shown that hypoxia, through HIF-1, induces ligand-independent $ER{\alpha}$ activation and the physical interaction of HIF-1 and $ER{\alpha}$. However, the effect of hypoxia on the transactivation of $ER{\beta}$ is not yet known. In the present study, we found that hypoxia activated the $ER{\beta}$-mediated transcriptional response in the HEK 293 cell line, as determined by the transient expression of$ER{\beta}$ and ER-responsive reporter plasmids. The hypoxia-induced estrogen response element-mediated transcriptional response was dependent on $ER{\beta}$ expression and was inhibited by the ER antagonist ICI 182,780. Transactivation of $ER{\beta}$ was induced by the expression of HIF-$1{\alpha}$ under normoxic conditions, as determined by the expression of oxygen-independent stable GFP-HIF-$1{\alpha}$. HIF-$1{\alpha}$-induced $ER{\beta}$ transactivation was abolished by the inhibition of HIF-$1{\alpha}$ activation. This was determined by using chemical inhibitors for the MAPK pathway. In addition, HIF-$1{\alpha}$ interacted with $ER{\beta}$ in a mammalian-two hybrid assay. We conclude that hypoxia activates $ER{\beta}$ in a ligand-independent manner, possibly through the interaction of HIF-$1{\alpha}$ and $ER{\beta}$.

  • PDF

A Study on the Control Characteristics of ER Valve-FHA System and Durability Test

  • Jang Sung-Cheol;Chang Tae-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권8호
    • /
    • pp.1621-1631
    • /
    • 2005
  • In this paper, making the best use of the features of the electro-rheological (ER) valve, a two-port pressure control valve using ER fluids is proposed and manufactured. The ER-Valve characteristics are evaluated by changing the intensity of the electric field and the number of electrode. As only with electrical signal change to the ER-Valve in which ER fluid flowing, ER fluid flow is controlled, so development of simple ER-Valves have been tried. The ER-Valves and pressure drop check method are considered to be applied to the fluid power industry. Using the manufactured pressure control valve, a one-link manipulator with FHA (Flexible Hydraulic Actuator) is driven. As a result, it is experimentally confirmed that the pressure control valve using ER fluids is applicable to use in driving actuator. If it applies characteristics of the ER fluids, it will be able to apply in the control system for the ER Valve which occurs from industrial controller. After having durability test, shear stress increased regularly because of starch particles crushed by pump and particle size that was almost the same. Moreover, Ra of copper electrode increased about 1.56 times rather than before those of performing durability test, and Rz increased about 2.2 times.

The Estrogen Receptor Negative-Progesterone Receptor Positive Breast Carcinoma is a Biological Entity and not a Technical Artifact

  • Ng, Char Hong;Pathy, Nirmala Bhoo;Taib, Nur Aishah;Mun, Kein Seong;Rhodes, Anthony;Yip, Cheng Har
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권4호
    • /
    • pp.1111-1113
    • /
    • 2012
  • The ER-/PR+ breast tumor may be the result of a false ER negative result. The aim of this study was to investigate whether there is a difference in patient and tumor characteristics of the ER-/PR+ phenotype in an Asian setting. A total of 2629 breast cancer patients were categorized on the basis of their age, ethnicity, tumor hormonal receptor phenotype, grade and histological type. There were 1230 (46.8%) ER+/PR+, 306 (11.6%) ER+/PR-, 122 (4.6%) ER-/PR+ and 972 (37%) ER-/PR-. ER-/PR+ tumors were 2.5 times more likely to be younger than 50 years at diagnosis (OR: 2.52; 95% CI: 1.72-3.67). Compared to ER+/PR+ tumors, the ER-/PR+ phenotype was twice more likely to be associated with grade 3 tumors (OR:2.02; 95%CI: 1.00-4.10). In contrast, compared to ER-/PR- tumors, the ER-/PR+ phenotype was 90% less likely to be associated with a grade 3 tumor (OR: 0.12; 95%CI:0.05-0.26), and more likely to have invasive lobular than invasive ductal histology (OR: 3.66; 95%CI: 1.47-9.11). These results show that the ER-/PR+ phenotype occurs in a younger age group and is associated with intermediate histopathological characteristics compared to ER+/PR+ and ER-/PR- tumors. This may imply that it is a distinct entity and not a technical artifact.