• Title/Summary/Keyword: $Cu^{2+}$ detection

Search Result 185, Processing Time 0.029 seconds

Novel Solid Phase Extraction Procedure for Some Trace Elements in Various Samples Prior to Their Determinations by FAAS

  • Sacmaci, Srife;Kartal, Senol;Sacmaci, Mustafa;Soykan, Cengiz
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.444-450
    • /
    • 2011
  • A novel method that utilizes poly(5-methyl-2-thiozyl methacrylamide-co-2-acrylamido-2-methyl-1-propanesulfonic acid-co-divinylbenzene) [MTMAAm/AMPS/DVB] as a solid-phase extractant was developed for simultaneous preconcentration of trace Cd(II), Co(II), Cr(III), Cu(II), Fe(III), Mn(II), Ni(II), Pb(II), and Zn(II) prior to the measurement by flame atomic absorpiton spectrometry (FAAS). Experimental conditions for effective adsorption of the metal ions were optimized using column procedures. The optimum pH value for the simultaneously separation of the metal ions on the new adsorbent was 2.5. Effects of concentration and volume of elution solution, sample flow rate, sample volume and interfering ions on the recovery of the analytes were investigated. A high preconcentration factor, 100, and low relative standard deviation values, $\leq$1.5% (n = 10), were obtained. The detection limits (${\mu}gL^{-1}$) based on the 3s criterion were 0.18 for Cd(II), 0.11 for Co(II), 0.07 for Cr(III), 0.12 for Cu(II), 0.18 for Fe(III), 0.67 for Mn(II), 0.13 for Ni(II), 0.06 for Pb(II), and 0.09 for Zn(II). The validation of the procedure was performed by the analysis of two certified reference materials. The presented method was applied to the determination of the analytes in various environmental samples with satisfactory results.

Sorption of Thiocyanate Silver Complexes and Determination of Silver by Diffuse Reflectance Spectroscopy

  • Kononova, O.N.;Goryaeva, N.G.;Vorontsova, T.V.;Bulavskaya, T.A.;Kachin, S.V.;Kholmogorov, A.G.
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.11
    • /
    • pp.1832-1838
    • /
    • 2006
  • The present paper is focused on sorption concentration of silver (I) on some complex-forming ion exchangers in the initial thiocyanate form and subsequent determination of Ag(I) in the phase of anion exchanger AN-25 by diffuse reflectance spectroscopy. The sorption and kinetic characteristics of the sorbents were investigated. The apparent stability constants of thiocyanate silver complexes in the ion exchanger phase were calculated. The sorption-spectroscopic method is proposed for Ag(I) determination in aqueous solutions. The calibration curve is linear in the concentration range of 10-200 mg/L (sample volume is 10.0 mL) and the detection limit is 2 $\mu$g/mL. The presence of $Na^+,\;K^+,\;Mg^{2+}$ (macrocomponents) as well as of Ni (II), Co (II), Cu (II) do not hinder the determination of silver (I).

Determination of Chromium(VI) by Differential-Pulse Polarography with a Sodium Borate Supporting Electrolyte

  • Hong, Tae-kee;Czae, Myung-Zoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.9 no.2
    • /
    • pp.77-80
    • /
    • 1988
  • A suituable choice of supporting electrolyte medium for trace level determinations of chromium(VI) by differential pulse polarography is described. A comparative study suggests that sodium borate buffer is superior to ammonium acetate, ammonium tartrate, and especially to NaF which was recently known to be one of the most proper medium for the purpose. With 0.01 M borate, the best combination of high sensitivity, well-defined base line, and freedom from common interferents was attained. With $5.0{\times}10^{-7}$M Cr(VI), tenfold excesses of Cu(II) and Fe(III), and a five hundred-fold excess of $Cl^-$ do not change the peak current by more than about 1%. And the detection limit was $5.0{\times}10^{-8}$M Cr(VI).

Bombesin-based Radiopharmaceuticals for Imaging and Therapy of Cancers Expressing Gastrin-releasing Peptide Receptor

  • Hwi-Soo Lim;Choong Mo Kang
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.8 no.2
    • /
    • pp.129-137
    • /
    • 2022
  • Bombesin has a high binding affinity to gastrin-releasing peptide receptor (GRPR) and can be used as a targeting ligand in GRPR-related cancers. Because GRPR is overexpressed in prostate cancer, bombesin analogues have been investigated extensively for diagnosis and treatment of prostate cancer. In nuclear medicine, bombesin derivatives labeled with radiometals such as 55/57Co, 64Cu, 68Ga, 99mTc, and 177Lu or radiohalogen such as 131I and 211At were developed as markers for early detection of tumors and theragnostic tool for cancer treatment. This review focuses on the introduction of bombesin-based radiopharmaceuticals that are studied in pre-clinical or clinical research.

Nanoplasmonic Spectroscopic Imaging and Molecular Probes

  • Choe, Yeon-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.85-85
    • /
    • 2013
  • Label-free, sensitive and selective detection methods with high spatial resolution are critically required for future applications in chemical sensor, biological sensor, and nanospectroscopic imaging. Here I describe the development of Plasmon Resonance Energy Transfer (PRET)-based molecular imaging in living cells as the first demonstration of intracellular imaging with PRET-based nanospectroscopy. In-vivo PRET imaging relied on the overlap between plasmon resonance frequency of gold nanoplasmonic probe (GNP) and absorption peak frequencies of conjugated molecules, which leads to create 'quantized quenching dips' in Rayleigh scattering spectrum of GNP. The position of these dips exactly matched with the absorption peaks of target molecules. As another innovative application of PRET, I present a highly selective and sensitive detection of metal ions by creating conjugated metal-ligand complexes on a single GNP. In addition to conferring high spatial resolution due to the small size of the metal ion probes (50 nm in diameter), this method is 100 to 1,000 folds more sensitive than organic reporter-based methods. Moreover, this technique achieves high selectivity due to the selective formation of Cu2+complexes and selective resonant quenching of GNP by the conjugated complexes. Since many metal ion ligand complexes generate new absorption peak due to the d-d transition in the metal ligand complex when a specific metal ion is inserted into the complex, we can match with the scattering frequency of nanoplasmonic metal ligand systems and the new absorption peak.

  • PDF

Investigation of Heavy Metal Contents by Milling Degrees of Rice (쌀의 도정도에 따른 중금속 함량 변화)

  • Kim, Jin-Kug;Lee, Ji-Hwan;Kim, Ji-Eun;Bae, In-Ae;Kim, Kwang-Seon;Lee, Eun-Suk;Kwon, Soon-Duck;Park, Ju-Hwan;Lee, Kyu-Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.303-308
    • /
    • 2015
  • BACKGROUND: Recently, various rice by milling degree is sold for health and taste. To provide safe food to consumers, it is need to know the change of heavy metal contents according to milling degree of rice.METHODS AND RESULTS: This study was to investigate residual the levels of cadmium (Cd), lead (Pb), copper (Cu) and zinc (Zn) as stated in the milling degree of the rice contaminated Cd and Pb from 2011 to 2012 in Chungcheongnam-do. Rice samples exceeded the maximum residue limits (MRL) of Cd and Pb were milled by five degrees (0.0, 2.45, 8.02, 10.48, 15.09%). Milled rice was digested by microwave method, and analyzed heavy metal contents using ICP-OES. Recovery ratios of 4 heavy metals such as Cd, Pb, Cu and Zn were ranged for 79.7-98.9%, and limits of detection (LOD) and limits of quantitation (LOQ) were fulfilled with the normal analytical standards. Concentrations of Cd, Pb, Cu and Zn were ranged 0.416-0.433 mg/kg, 0.183-0.26 mg/kg, 3.639- 3.882 mg/kg and 16.868-19.801 mg/kg, respectively.CONCLUSION: From these results, conforming with increase of milling degree of rice, Cd, Pb, Cu, and Zn contents tended to decrease. The contents of heavy metals were decreased 3.1% in Cd, 29.3% in Pb, 6.4% in Cu and 15.1% in Zn, in according to the highest milling degree of 15.09%.

Effects of ischemic preconditioning, KATP channel on the SOD activation and apoptosis in ischemic reperfused skeletal muscle of rat (허혈양상화와 KATP 통로가 허혈후 재관류된 흰쥐의 골격근육에서 SOD 활성 및 apoptosis에 미치는 영향)

  • Abn, Dong-choon;Paik, Doo-jin;Yang, Hong-hyun
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.5
    • /
    • pp.878-895
    • /
    • 1999
  • Ischemic preconditioing (IPC), i.e., a preliminary brief episode of ischemia and reperfusion, has been shown to reduce the cell damage induced by long ischemia and reperfusion. Superoxide radical which is produced during reperfusion after ischemia was recognized as a factor of the ischemic injury and it is dismutated into $H_2O_2$ and $O_2$ by two types of intracellular superoxide dismutase (SOD), Cu,Zn-SOD in cytoplasm and Mn-SOD in mitochondria. Recently oxygen free radicals are suggested to induce the apoptosis, however mechanism of the reduced apoptosis by ischemic preconditioing was unknown, while many studies performed in mammalian heart indicated that ATP-sensitive $K^+$ ($K_{APT}$) channel activation related with the protective effects. The aim of present study is to investigate 1) whether IP upregulate the Cu,Zn-SOD and Mn-SOD activities, and 2) whether ischemic preconditioning decreases apoptosis via $K_{APT}$ channel activation in timely reperfused skeletal muscle after long ishemia. The experimental animals, Sprague-Dawley rats weighing 250~300g, were divided into 8 groups; 1) control group, 2) ischemic preconditioning only groups, 3) pinacidil, a $K_{APT}$ channel opener, treatment only groups, 4) glibenclamide, a $K_{APT}$ channel blocker, treatment only groups, 5) ischemia groups, 6) ischemia after IPC groups, 7) ischemia and pinacidil treatment groups, and 8) IP and ischemia after glibenclamide pretreatment groups. Animals of the control group were administered with the vehicle (DMSO) alone. Pinacidil (1mg/kg) was administered intravenously 5 minutes after initiation of ischemia, and glibenclamide (0.5mg/kg) was injected intravenously 20 minutes before IPC. In rats that were ischemic preconditioned, the left common iliac artery was occluded for 5 minutes followed by 5 minutes of reperfusion by three times using vascular clamp. Ischemia was done by occlusion of the same artery for 4 hours. The specimens of left rectus femoris muscle were obtained immediately (0 hour), 12 hours, 24 hours after drug administrations, IP or ischemia and reperfusion. The immunoreactivities of SOD and its alterations were observed by use of sheep antihuman Cu,Zn-SOD and Mn-SOD antibodies on the $10{\mu}m$ cryosections. The incidencies of apoptosis were observed by TUNEL methods with in situ apoptosis detection kit on $6{\mu}m$ paraffine section. The results obtained were as follows : 1. After IPC, immunoreactivities of Cu,Zn-SOD mainly in the small-sized fibers were increased by 24 hours, that of Mn-SOD at 0 hour and 24 hours. 2. No significant changes in immunoreactivities of SOD was observed in the pinacidil and in the glibenclamide treatment only groups, and in the ischemia only groups. 3. The immunoreactivities of the Cu,Zn-SOD were increased in the ischemia after IPC groups and the ischemia and pinacidil treatment groups. 4. The immunoreactivities of the Cu,Zn-SOD in the IPC and ischemia after glibenclamide pretreatment groups were not increased except for the 12 hours reperfusion group. But, Mn-SOD immunoreactivities were increased in the 0 hours, 12 hours and 24 hours after reperfusion. 5. In the control group, the IPC only groups, and the pinacidil treatment only groups, negative or trace apoptotic reactions were observed, but the positive apoptotic reaction occured in the glibenclamide treatment groups. 6. Moderate or many number of apoptosis were revealed in the ischemia groups, and also the IPC and ischemia after glibenclamide pretreatment group except for 12 hours and 24 hours after reperfusion. However, the incidence of apoptosis was decreased in the ischemia after IPC groups and in the ischemia and pinacidil treatment groups. 7. There is a coincidence between the increase of Cu,Zn-SOD immunoreactivities and the decrease of apoptosis in the presence of ischemia and reperfusion. These results suggest that the protective effects of ishemic preconditioing may related to the SOD activation, and the ischemic preconditioning decreases the apoptosis partially via $K_{APT}$ channel activation in timely reperfused rat skeletal muscle. It is also suggested that inhibition of apoptosis by IPC may related with the SOD activation.

  • PDF

A Study on the Water Quality of Reservoir Tank in the Building Complex on Jeonnam Area (대형건축물 저수조의 수질실태 및 개선방안에 관한 연구)

  • Lee, J.H.;Lee, H.H.;Kim, H.B.;Ahn, G.W.;Park, K.N.;Kim, Y.K.;Bae, J.S.;Mun, H.;Park, C.U.;Oh, E.H.;Park, S.I.;Seo, Y.G.
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.59-77
    • /
    • 2000
  • This study was carried out to investigate on several factors, which contaminative the water quality through the water pipe during feeding water, in 42 largescaled apart-ments(total 84 cases) and assayed the Volatile Organic Compounds(VOCs) and concen-tration of heavy metals that inflow and outflow in reservior water in Jeonnam area(Mokpo, Suncheon, Yeosu) from January 1999 to December 1999. The results obtained were summarized as follows ; 1. The quality of the water pipe composition in the order of frequency in the quality of water pipes were Copper(45.2%)> Zinc(38.9%)> Stainless steel(9.5%)> PVC(4.8%)> PM(2.4%) in observing 42 sites. All of the drain pipes were used the cast iron quality. 2. The result of certification curve from 12 items(17kind) of VOCs was $1.0-4.0{\mu{g}}/{\ell}$ range, a coefficient of correlation was shown 0.99 over. A MDL of each substance range was within $0.1-1.0{\mu{g}}/{\ell}$. 3. The result of the assay, 5 kinds(Viny chloride, Dichloromethane, Ethylbenzene, M,P-xylene, Styrene) of the VOCs of 14 kinds was not detected and the other items were detected slightly. The detection rate of one item and over in total VOCs samples, were 25.9% in inflow and 27.9% in outflow. And frequency of detect in inflow/outflow of THM(Chloroform, Bromodichloro-methane, Dibromochloromethane, Bromoform) were shown higher than 94.1%, 97.0% each stages. It comes to the conclusion that all of the samples were reason able for drinking water standards. 4. The coefficient of correlation were reasonable, it shown 0.999 over in $0.1-1.0{\mu{g}}/{\ell}$ of a measuring range conditions of 4kinds in organic substance(Zn, Cu, Fe, Mn). 5. The results were showed suitability in 78 cases(92.9%) and unsuitability in 6 cases (7.1%), in 84 cases of in organic substances. Compare to inflow stage, mean concentrations of heavy metal, were increased slightly in Zn, Cu, Fe except Mn than outflow stage. The result of the mean concentration in organic substance inflow and outflow in the apartment water tank using Pair-compared T-test, in 95% reliance index, were $0.179mg/{\ell}(0.151-0.307mg/{\ell})$ in Zinc, $0.136mg/{\ell}(0.113-0.230mg/{\ell})$ in Copper, $0.052mg/{\ell}(0.048-0.098mg/{\ell})$ in Fe, and there was a bit growing tendency but there was no differece in Mn. 6. The mean concentration of Copper which used Cu pipe as a water supply pipe in apartment were $0.216mg/{\ell}(0.161-0.338mg/{\ell})$ in case of the Zine pipe were $0.286mg/{\ell}(0.204-0.435mg/{\ell})$. It shows that the detection rate was more higher than the other material used in Cu or Zn as the water supply pipe. We supposed to Cu and Zn substance were gushing out water supply pipe.

  • PDF

Effect of novel luminol-based blood detection reagents on DNA stability (새로운 루미놀 기반 혈흔 탐지 시약이 디엔에이에 미치는 영향에 대한 연구)

  • Jung, Ju Yeon;Oh, Yu-Li;Lee, Jee Won;Lim, Seung;Kim, Jung-mok;Lee, Yang Han;Lim, Si-Keun
    • Analytical Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.71-77
    • /
    • 2018
  • Detection of bloodstains is a very important process in scientific investigations, and luminol is often used for the detection of bloodstains that are not visible. Recently, new preparation methods of blood detection reagents based on luminol (BloodFlareA, B) were developed and reported to have higher active persistence and to be more economical than conventional blood detection reagent, BlueStar forensic. In this paper, we tested the specificity and effect of the BloodFlares (A and B) on DNA and compared them with those of BlueStar forensic. False positive results for the BloodFlares were not observed in semen, saliva, vaginal fluids, urine, sweat, and nasal discharge, but were observed in $CuSO_4$, $FeSO_4$, and bleach solutions, and the observed patterns were similar to those of BlueStar forensic. The effect on DNA was determined by analyzing the DNA yield, degradation index, and DNA profiling. Based on these results, we concluded that the BloodFlares based on luminol do not affect DNA stability and are applicable in forensics.

Novel Incremental Spectrum Sensing in Cooperative Cognitive Radio Networks (협력 인지 통신 네트워크에서 새로운 증분형 스펙트럼 검출)

  • Ha, Nguyen Vu;Kong, Hyung-Yun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.9A
    • /
    • pp.859-867
    • /
    • 2010
  • In this paper, we consider a novel spectrum sensing system in which firstly, the fusion center (FC) senses and makes the own decision then if its sensing result is not useful for achieving the final decision, the local observations from the cognitive users (CUs) will be required. Moreover, in case that FC needs the results from CUs, we will choose only CU having the highest collected energy to send its local decision to FC. Based on this selecting method, the number of sensing bits can be reduced; hence, we can save the power and the bandwidth for reporting stage in the cognitive radio network (CRN). The mathematical analysis of the key metrics of the sensing schemes (probability of detection, false alarm, e.g.) will be investigated and confirmed by the Monte-Carlo simulation results to show the performance enhancement of the proposed schemes.