• 제목/요약/키워드: $Cr_2N$ nitride

검색결과 53건 처리시간 0.023초

고압용 박막형 압력센서의 특성 (Characteristics of thin-film type pressure sensors for high pressure)

  • 서정환;최성규;정찬익;류지구;남효덕;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.737-740
    • /
    • 2001
  • This paper describes the fabrication and characteristics of CrN thin-film type pessure sensors, which the sensing elements were deposited on SUS. 630 diaphragm by DC reactive magnetron sputtering in an argon-nitride atmosphere(Ar-(10%)N$_2$). The optimized condition of CrN thin-film sensing elements was thickness range of 3500${\AA}$ and annealing condition(300$^{\circ}C$, 3 hr) in Ar-10 %N$_2$deposition atmosphere. Under optimum conditions, the CrN thin-films for strain gauges is obtained a high resistivity, $\rho$=1147.65 ${\mu}$$\Omega$cm, a low temperature coefficient of resistance, TCR=-186 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal, 11.17. The output sensitivity of fabricated CrN thin-film type pressure sensors is 2.36 mV/V, 4∼20 mA and the maximum non-linearity is 0.4 %FS and hysteresis is less than 0.2 %FS.

  • PDF

Growth and Properties of CrNx/TiNy/Al Based on N2 Gas Flow Rate for Solar Thermal Applications

  • Ju, Sang-Jun;Jang, Gun-Eik;Jang, Yeo-Won;Kim, Hyun-Hoo;Lee, Cheon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권3호
    • /
    • pp.146-149
    • /
    • 2016
  • The CrN/TiN/Al thin films for solar selective absorber were prepared by dc reactive magnetron sputtering with multi targets. The binary nitride CrN layer deposited with change in N2 gas flow rates. The gas mixture of Ar and N2 was an important parameter during sputtering deposition because the metal volume fraction (MVF) was controlled by the N2 gas flow rate. In this study, the crystallinity and surface properties of the CrN/TiN/Al thin films were estimated by X-ray diffraction (XRD), atomic force microscopy (AFM) and field emission scanning electron microscopy (FESEM). The composition and depth profile of thin films were investigated using Auger electron spectroscopy (AES). The absorptance and reflectance with wavelength spectrum were recorded by UV-Vis-NIR spectrophotometry at a range of 300~1,100 nm.

Effectiveness of medical coating materials in decreasing friction between orthodontic brackets and archwires

  • Arici, Nursel;Akdeniz, Berat S.;Oz, Abdullah A.;Gencer, Yucel;Tarakci, Mehmet;Arici, Selim
    • 대한치과교정학회지
    • /
    • 제51권4호
    • /
    • pp.270-281
    • /
    • 2021
  • Objective: The aim of this in vitro study was to evaluate the changes in friction between orthodontic brackets and archwires coated with aluminum oxide (Al2O3), titanium nitride (TiN), or chromium nitride (CrN). In addition, the resistance of the coatings to intraoral conditions was evaluated. Methods: Stainless steel canine brackets, 0.016-inch round nickel-titanium archwires, and 0.019 × 0.025-inch stainless steel archwires were coated with Al2O3, TiN, and CrN using radio frequency magnetron sputtering. The coated materials were examined using scanning electron microscopy, an X-ray diffractometer, atomic force microscopy, and surface profilometry. In addition, the samples were subjected to thermal cycling and in vitro brushing tests, and the effects of the simulated intraoral conditions on the coating structure were evaluated. Results: Coating of the metal bracket as well as nickel-titanium archwire with Al2O3 reduced the coefficients of friction (CoFs) for the bracket-archwire combination (p < 0.01). When the bracket and stainless steel archwire were coated with Al2O3 and TiN, the CoFs were significantly lower (0.207 and 0.372, respectively) than that recorded when this bracket-archwire combination was left uncoated (0.552; p < 0.01). The friction, thermal, and brushing tests did not deteriorate the overall quality of the Al2O3 coatings; however, some small areas of peeling were evident for the TiN coatings, whereas comparatively larger areas of peeling were observed for the CrN coatings. Conclusions: Our findings suggest that the CoFs for metal bracket-archwire combinations used in orthodontic treatment can be decreased by coating with Al2O3 and TiN thin films.

Influence of Deposition Temperature on the Film Growth Behavior and Mechanical Properties of Chromium Aluminum Nitride Coatings Prepared by Cathodic Arc Evaporation Technique

  • Heo, Sungbo;Kim, Wang Ryeol
    • 한국표면공학회지
    • /
    • 제54권3호
    • /
    • pp.139-143
    • /
    • 2021
  • Cr-Al-N coatings were deposited onto WC-Co substrates using a cathodic arc evaporation (CAE) system. CAE technique is recognized to be a very useful process for hard coatings because it has many advantages such as high packing density and good adhesion to metallic substrates. In this study, the influence of deposition temperature as a key process parameter on film growth behavior and mechanical properties of Cr-Al-N coatings were systematically investigated and correlated with microstructural changes. From various analyses, the Cr-Al-N coatings prepared at deposition temperature of 450℃ in the CAE process showed excellent mechanical properties with higher deposition rate. The Cr-Al-N coatings with deposition temperature around 450℃ exhibited the highest hardness of about 35 GPa and elastic modulus of 442 GPa. The resistance to elastic strain to failure (H/E ratio) and the index of plastic deformation (H3/E2 ratio) were also good values of 0.079 and 0.221 GPa, respectively, at the deposition temperature of 450℃. Based on the XRD, SEM and TEM analyses, the Cr-Al-N coatings exhibited a dense columnar structure with f.c.c. (Cr,Al)N multi-oriented phases in which crystallites showed irregular shapes (50~100nm in size) with many edge dislocations and lattice mismatches.

$Si_3N_4$ 기판 위에 PECVD 법으로 형성한 Tungsten Nitride 박막의 특성 (Characteristic of PECVD-$WN_x$ Thin Films Deposited on $Si_3N_4$ Substrate)

  • 배성찬;박병남;손승현;이종현;최시영
    • 전자공학회논문지D
    • /
    • 제36D권7호
    • /
    • pp.17-25
    • /
    • 1999
  • PECVD 법을 이용하여 Tungsten Nitride($WN_x$) 박막을 $WSi_3N_4$ 기판위에 형성하였다. $WN_x$ 박막은 기관온도, 가스의 유량, rf power 등의 공정변수를 변화시키면서 형성되었고, 서로 다른 질소원으로 $NH_3$$N_2$를 각각 사용하여 박막의 특성을 조사하였다. $WN_x$ 막 내의 질소함량은 $NH_3$$N_2$의 유량에 따라 0~45% 정도로 변화하였으며, $NH_3$를 사용하였을 때, 최고 160nm/min의 높은 성장률을 나타내었다. $WSi_3N_4$ 기판 위에서는 TiN이나 Si 위에서보다 높은 성장률을 나타내었다. $WN_x$ 박막의 순도를 AES로 측정해 본 결과 $NH_3$를 사용했을 때 고순도의 박막을 얻을 수 있었다. XRD 분석으로 순수한 다결정의 W가 비정질의 $WN_x$로 변화되는 것을 알 수 있었으며, 이것은 $WN_x$가 식각 공정시 미세 패턴 형성이 W보다 유리할 것이라는 것을 보여준다. TiN, NiCr, Al 등의 다양한 기판 위에 형성해 본 결과 Al 위에서 최대 $1.6 {\mu}m$의 두꺼운 막이 형성되었다.

  • PDF

크롬질화박막형 스트레인 게이지의 특성 (The Characteristics of Chromiun Nitride Thin-Film Strain Gauges)

  • 서정환;김일명;이채봉;김순철;정귀상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1989-1991
    • /
    • 1999
  • This paper presents characteristics of CrN thin-film strain gauges, which were deposited on glass by DC reactive magnetron sputtering in an argon-nitrogen atmosphere(Ar-$(5{\sim}25%)N_2$). The physical and electrical characteristics of these films investigated with the thickness range $3500{\AA}$ of CrN thin films, annealing temperature $(100{\sim}300^{\circ}C)$ and annealing $(24{\sim}72hr)$. The optimized condition of CrN thin-film strain gauges were thickness range of $3500{\AA}$ and annealing condition($300^{\circ}C$, 48 hr) in Ar-10 %$N_2$ deposition atmosphere. Under optimum conditions, the CrN thin-films for strain gauge is obtained a high resistivity, ${\rho}=1147.65{\mu}{\Omega}cm$, a low temperature coefficient of resistance, TCR=$-186ppm/^{\circ}C$ and a high temporal stability with a good longitudinal, 11.17. And change in resistance after annealing for the CrN thin-films were quitely linear and stable.

  • PDF

인공관절의 수명 향상을 위해 Plasma Immersion Ion Implantation & Deposition 공정으로 증착된 NbN 박막에 대한 UHMWPE Liner 소재의 마모량 평가

  • 박원웅;김은겸;전준홍;최진영;문선우;임상호;한승희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.137-137
    • /
    • 2012
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등으로 인하여 발생하는 관절의 손상 부위를 대체하기 위하여 고안된 관절의 인공 대용물이다. 인공 관절 중 인공 고관절의 경우 라이너(Liner)와 헤드(Head) 부분이 직접적인 마모 운동을 수행하게 되므로, 이 부분의 소재 특성에 따라 인공관절의 수명이 결정 되게 된다. 현재 헤드 소재로서는 Co-Cr-Mo 합금이, 라이너 소재로서는 고분자 소재인 UHMWPE (Ultra High Molecular Weight Polyethylene)가 주로 사용되고 있다. 이러한 MOP (Metal-On-Polymer) 구조의 인공관절의 경우, 충격흡수의 장점이 있는 반면, 관절 운동시 발생하는 UHMWPE 의wear debris에 의해 골용해가 발생하게 되어 인공관절의 수명이 저하되는 문제점이 있으며, 금속 헤드의 마모로 인한 금속이온의 용출은 세포 독성의 문제를 야기하여 인공관절의 수명을 저하시키는 또 다른 원인이 되고 있다. 따라서 본 연구에서는 PIII&D (Plasma Immersion Ion Implantation & Deposition) 공정을 이용하여 금속 (Co-Cr-Mo 합금)소재 위에 세라믹 (niobium nitride) 박막을 증착하여 상대재인 UHMWPE의 마모를 줄이고자 하는 연구를 진행하였다. 금속 소재 위에 증착된 세라믹 박막은 상대재인 UHMWPE의 마모량을 줄여줄 뿐만 아니라 금속이온의 용출을 막아준다는 장점이 있으나, 장시간의 마모 운동에 의하여 발생하는 박막의 박리 현상은 인공관절의 수명을 급격히 저하시키는 또 다른 원인이 된다. 이러한 단점을 해결하기 위하여, 박막의 증착 초기에 이온주입과 증착을 동시에 수행하는 dynamic ion mixing공정을 수행하였다. Dynamic ion mixing 공정을 수행함에 따라 박막과 금속 사이의 접착력이 증가하게 되어, UHMWPE의 마모량이 2배 가까이 감소하는 것을 확인할 수 있었으며, 장시간의 마모시험에서도 우수한 결과를 얻을 수 있었다. 또한 UHMWPE의 마모량을 감소시키기 위하여 박막을 증착하기 전에 금속 소재에 질소 이온주입을 수행하는 pre-ion implantation 공정을 도입하였다. 질소 이온주입 결과 Co-Cr-Mo 합금 표면에 부분적으로 CrN, Cr2N의 세라믹 상이 형성 되는 것을 확인할 수 있었으며, 그에 따라 UHMWPE의 마모량이 2배 이상 감소 되는 것을 확인 할 수 있었다.

  • PDF

드릴공구의 이종질화막상 DLC 희생층 적용을 통한 공구 수명 개선 연구 (A Study on the Improvement of Tool's Life by Applying DLC Sacrificial Layer on Nitride Hard Coated Drill Tools)

  • 강용진;김도현;장영준;김종국
    • 한국표면공학회지
    • /
    • 제53권6호
    • /
    • pp.271-279
    • /
    • 2020
  • Non-ferrous metals, widely used in the mechanical industry, are difficult to machine, particularly by drilling and tapping. Since non-ferrous metals have a strong tendency to adhere to the cutting tool, the tool life is greatly deteriorated. Diamond-like carbon (DLC) is one of the promising candidates to improve the performance and life of cutting tool due to their low frictional property. In this study, a sacrificial DLC layer is applied on the hard nitride coated drill tool to improve the durability. The DLC coatings are fabricated by controlling the acceleration voltage of the linear ion source in the range of 0.6~1.8 kV. As a result, the optimized hardness(20 GPa) and wear resistance(1.4 x 10-8 ㎣/N·m) were obtained at the 1.4 kV. Then, the optimized DLC coating is applied as an sacrificial layer on the hard nitride coating to evaluate the performance and life of cutting tool. The Vickers hardness of the composite coatings were similar to those of the nitride coatings (AlCrN, AlTiSiN), but the friction coefficients were significantly reduced to 0.13 compared to 0.63 of nitride coatings. The drilling test were performed on S55C plate using a drilling machine at rotation speed of 2,500 rpm and penetration rate of 0.25 m/rev. The result showed that the wear width of the composite coated drills were 200 % lower than those of the AlCrN, AlTiSiN coated drills. In addition, the cutting forces of the composite coated drills were 13 and 15 % lower than that of AlCrN, AlTiSiN coated drills, respectively, as it reduced the aluminum clogging. Finally, the application of the DLC sacrificial layer prevents initial chipping through its low friction property and improves drilling quality with efficient chip removal.

다층박막 코팅된 PEMFC (Proton Exchange Membrane Fuel Cell)용 바이폴라 플레이트 (Multi-film coated bipolar plates for PEMFC (Proton Exchange Membrane Fuel Cell) application)

  • 전광연;윤영훈;차인수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.646-648
    • /
    • 2008
  • The multi-films of a metallic film and a transparent conducting oxide (TCO, indium-tin oxide, ITO) film were formed on the stainless steel 316 and 304 plates by a sputtering method and an E-beam method and then the external metallic region of the stainless steel bipolar plates was converted into the metal nitride films through an annealing process. The multi-film formed on the stainless steel bipolar plates showed the XRD patterns of the typical indium-tin oxide, the metallic phase and the metal substrate and the external nitride film. The XRD pattern of the thin film on the bipolar plates modified showed two metal nitride phases of CrN and $Cr_2N$ compound. Surface microstructural morphology of the multi-film deposited bipolar plates was observed by AFM and FE-SEM. The electrical resistivity of the stainless steel bipolar plates modified was evaluated.

  • PDF

고압용 압력센서의 제작과 그 특성 (Fabrication and Characteristics of pressure sensors for high pressure)

  • 최성규;서정환;정귀상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1375-1377
    • /
    • 2001
  • This paper describes the fabrication and characteristics of CrN thin-film type pessure sensors, in which the sensing elements were deposited on SUS. 630 diaphragm by DC reactive magnetron sputtering in an argon-nitride atmosphere(Ar-(10%) $N_2$). The optimized condition of CrN thin-film sensing elements was thickness range of 3500$\AA$ and annealing condition($300^{\circ}C$, 3 hr) in Ar-10 %$N_2$ deposition atmosphere. Under optimum conditions, the CrN thin-films for strain gauges is obtained a high resistivity, $\rho$=1147.65 ${\mu}{\Omega}$cm, a low temperature coefficient of resistance, TCR=-186 ppm/$^{\circ}C$ and a high temporal stability with a good longitudinal, 11.17. The output sensitivity of fabricated CrN thin-film type pressure sensors is 2.36 mV/V, 4$\sim$20 mA and the maximum non-linearity is 0.4 %FS and hysteresis is less than 0.2 %FS..

  • PDF