• Title/Summary/Keyword: $Cr^{6+}$

검색결과 2,929건 처리시간 0.034초

다공성 Cr2O3 나노육각기둥을 이용한 C2H5OH 센서 (C2H5OH Sensor Using Porous Cr2O3 Nano-Hexaprisms)

  • 정현묵;이종흔
    • 센서학회지
    • /
    • 제21권6호
    • /
    • pp.451-455
    • /
    • 2012
  • Dense Cr-precursor nano-hexaprisms were prepared by heating the Cr-nitrate aqueous solution containing Hexamethylenetetramine and polyvinylpyrrolidone, which were converted into porous $Cr_2O_3$ nano-hexaprisms containing nanoparticles by heat treatment of Cr-precursors at $600^{\circ}C$ for 2 h in air atmosphere. At the sensor temperature of $300^{\circ}C$, porous $Cr_2O_3$ nano-hexaprism showed the high response ($R_g/R_a$, $R_g$: resistance in gas, $R_a$: resistance in air) to 100 ppm $C_2H_5OH$ ($R_g/R_a=69.8$) with negligible cross-responses to 100 ppm CO and 5 ppm $C_6H_6$. The sensitive and selective detection of $C_2H_5OH$ in porous $Cr_2O_3$ nano-hexaprism were discussed in relation to the morphology of nanostructures.

$Al_2O_3-CaO-Cr_2O_3$ 계 내화물의 고온 안정성 (High Temperature Stability for Refractories of the System $Al_2O_3-CaO-Cr_2O_3$)

  • 이홍립
    • 한국세라믹학회지
    • /
    • 제17권1호
    • /
    • pp.8-12
    • /
    • 1980
  • CaO was added to the $MgAlCrO_4$ spinel, a main component of the mag-chro refractroies, by 0, 1, 5 and 10 mol% before sintering at 135$0^{\circ}C$ in air. The X-ray diffraction analysis produced an additional X-ray diffraction pattern of 8CaO.$6Al_2O_3$.$2CrO_3$ besides that of $MgAlCrO_4$. The formation of 8CaO.$6Al_2O_3$.$2CrO_3$ was interpreted as due to the presence of CaO.8CaO.$6Al_2O_3$.$2CrO_3$ was unstable and easily vaporized. It was concluded that formation of the unstable pollutant 8CaO.$6Al_2O_3$.$2CrO_3$ could be prevented in reducing atmospheres. It was found that the basic refractories containing $Al_2 O_3 -CaO-Cr_2 O_3$ system would be more stable and much less toxic in reducing at mospheres than in oxidizing stmosphere.

  • PDF

Ferroelectric Properties of Substituted Aurivillius Phases SrBi2Nb2-xMxO9 (M=Cr, Mo)

  • Moon, S.-Y.;Choi, K. S.;Jung, K. W.;Lee, H.;Jung, D.
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권10호
    • /
    • pp.1463-1482
    • /
    • 2002
  • Partially doped Aurivillius phases SrBi2N$b_{2-x}M_xO_9$ (M=Cr and Mo) were successfully synthesized and characterized. The extent of the substitution was limited at ~20 mole % because of the size differences between $Nb^{5+}$ and $Cr^{6+}$, and between $Nb^{5+}$ and $Mo^{6+}$. When the amount of substitution exceeded ~20 mole%, the phases began to collapse and the second phases were made. The dielectric constants of substituted compounds were enlarged nevertheless Cr or Mo is substituted. The increment is bigger in the Mo substituted compound than in the Cr doped one although the Nb(Cr)$O_6$ octahedra could be more strongly distorted than the Nb(Mo)$O_6$ octahedra since the ionic size difference between $Nb^{5+}$ and of $Cr^{6+}$ is much bigger than that between $Nb^{5+}$ and $Mo^{6+}$. Consequently, the dielectric constant of the substituted Aurivillius phase $Bi_2$A_{n-1}B_{n-x}M_xO_{3n+1}$$ depends on the extent of distortion of the B$O_6$ octahedra and more strongly on the polarizability of the metal.

Cr-51 EDTA GFR 검사 결과의 분석 및 의의 (Estimation of Glomerular Filtration Rate using Chromium-51 EDTA)

  • 임수연;문형호;유선희;조시만
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.98-103
    • /
    • 2009
  • Purpose: Correct estimation of Glomerular filtration rate (GFR) is very important for an accurate clinical assessment of the kidney function. This study compares four GFR markers, a serum creatinine-based estimation using MDRD formula, Cystatin-C, Cr-51 EDTA 2 samples and 6 samples. Materials and Methods: Serum creatinine concentrations, Cystatin-C serum concentrations and Cr-51 EDTA clearance are measured in 43 patients who received or donated kidney. Results: The correlation coefficient between serum based estimated GFR (MDRD) and Cr-51 EDTA 6 samples was 0.817 (p<0.01). The correlation coefficient between Cystatin-C based GFR and EDTA 6 samples was 0.7322 (p<0.01). Regression analysis showed a statistically significant correlation between Cr-51 EDTA 2 samples and 6 samples (r=0.971, p<0.01). Mean value and ${\pm}2SD$ for the difference between Cr-51 EDTA 2 samples and 6 samples were 4.7 mL/min and ${\pm}9.3$ respectively. Conclusions: The estimation of two samples Cr-51 EDTA showed that the method can be simplified by reducing blood samples without losing its high accuracy.

  • PDF

Microstructure and Mechanical Properties of Cr-Mo Steels for Nuclear Industry Applications

  • Kim, Sung-Ho;Ryu, Woo-Seong;Kuk, Il-Hiun
    • Nuclear Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.561-571
    • /
    • 1999
  • Microstructure and mechanical properties of five Cr-Mo steels for nuclear industry applications have been investigated. Transmission electron microscopy, energy dispersive spectrometer, differential scanning calorimeter, hardness, tensile, and impact test were used to evaluate the Cr and W effect on the microstructure and mechanical properties. Microstructures of Cr-Mo steels after tempering are classified into three types : bainitic 2.25Cr-lMo steel, martensitic Mod.9Cr-lMo, HT9M, and HT9W steels, and dual phase HT9 steel. The majority of the precipitates were found to be M$_{23}$C$_{6}$ carbides. As minor phases, fine needle-like V(C,N), spherical NbC, fine needle-like Cr-rich Cr$_2$N, and Cr-rich M$_{7}$C$_3$were also found. Addition of 2wt.% W in Cr-Mo steels retarded the formation of subgrain and dissolution of Cr$_2$N precipitates. Hardness and ultimate tensile strength increased with increasing Cr content. Though Cr content of HT9W steel was lower than that of HT9 steel, the hardness of HT9W was higher due to the higher W content. W added HT9W steel had the highest ultimate tensile strength above $600^{\circ}C$. But impact toughness of W added steel (HT9W) and high Cr steel (HT9) was low.w.w.

  • PDF

공기 중에서 금속 헥사카르보닐 착물 $M(CO)_6$ (M=Cr, Mo, W)를 이용한 폴러렌 산화물 $[C_{70}O_n](n=1{\sim}2)$의 초음파화학 합성 (Sonochemical Synthesis of Fullerene Oxides $[C_{70}O_n](n=1{\sim}2)$ Using Metal Hexacarbonyl Complexes $M(CO)_6$ (M=Cr, Mo, W) Under Air Atmosphere)

  • 고원배;박영환
    • Elastomers and Composites
    • /
    • 제40권3호
    • /
    • pp.174-180
    • /
    • 2005
  • 공기 중 초음파 조건에서 풀러렌$[C_{70}]$과 금속 헥사카르보닐 착물 $M(CO)_6$ (M=Cr, Mo, W)을 반응시켜 풀러렌 산화물 $[C_{70}O_n](n=1{\sim}2)$을 합성하였다. 동일한 초음파 조건에서 풀러렌$[C_{70}]$과 여러 가지 금속 헥사카르보닐 착물 $M(CO)_6$ (M=Cr, Mo, W)의 반응성은 $Mo(CO)_6$ > $W(CO)_6$ > $Cr(CO)_6$ 순으로 증가함을 나타냈다. MALDI-TOF-MS, UV-visible 스펙트럼과 HPLC를 사용하여 분석한 결과 초음파화학 반응의 생성물은 $[C_{70}O_n](n=1{\sim}2)$ 임을 알 수 있었다.

말똥성게(Hemicentrotus pulcherrimus)의 수정 및 배아 발생률에 대한 비소와 크롬의 독성영향 (Toxic Effects of Arsenic and Chromium on the Fertilization and Embryo Development Rates in the Sea Urchin (Hemicentrotus pulcherrimus))

  • 황운기;류향미;유준;강한승
    • 환경생물
    • /
    • 제31권2호
    • /
    • pp.69-77
    • /
    • 2013
  • 말똥성게 (Hemicentrotus pulcherrimus)의 생식세포 및 pluteus 유생을 이용하여 중금속인 Arsenic (As)와 Chromium (Cr)이 정상 수정률 및 배아 발생률에 미치는 독성 영향을 조사하였다. H. pulcherrimus의 수정률 및 배아 발생률에 미치는 As와 Cr의 독성은 6.25, 12.5, 25, 50, 100 ppb의 농도에서 조사하였다. 0.5 M KCl 용액을 이용하여 방란 및 방정을 유도하였고, 정상 수정률 및 배아발생률은 수정 후 각각 10분 및 64시간째 관찰하였다. As와 Cr을 첨가하지 않은 대조구에서 정상 수정률과 배아 발생률은 각각 94%와 93% 이상을 나타냈다. 이들 중금속 첨가에 의해 수정률은 아무런 변화가 나타나지 않았지만 배아 발생률은 농도 의존적 감소하는 것으로 나타났으며, As의 첨가에 의해 배아 발생률은 6.25 ppb에서 유의적으로 감소하였으며 (P<0.01), Cr의 경우는 25 ppb에서 유의적인 감소를 나타냈다 (P<0.05). H. pulcherrimus의 정상 배아 발생률에 대한 LOEC는 As의 경우는 6.25 ppb를 Cr은 25 ppb를 나타냈다. 이들 연구결과로 해양생태계 내에서 As가 6.25 ppb, Cr이 25 ppb를 초과하는 농도일 때는 H. pulcherrimus와 같은 무척추동물의 정상 부화율은 급격히 감소할 것으로 판단된다. 본 연구결과를 바탕으로, H. pulcherrimus의 정상 배아 발생률을 이용한 생물학적 평가방법은 중금속과 같은 유해물질에 대한 해양생태계의 영향을 판단하기 위한 시험방법으로 유용하게 이용될 수 있을 것으로 판단된다.

함산소불화 활성탄소섬유를 이용한 저농도 크롬이온의 흡착 특성 (Adsorption Characteristics of Chromium Ion at Low Concentration Using Oxyfluorinated Activated Carbon Fibers)

  • 김민지;정민정;최석순;이영석
    • 공업화학
    • /
    • 제26권4호
    • /
    • pp.432-438
    • /
    • 2015
  • 본 연구에서는 활성탄소섬유(ACFs)에 함산소불화 표면처리를 수행하여 수용액상에 존재하는 저농도 $Cr^{6+}$ 이온의 흡착특성을 조사하였다. ACFs의 기공구조와 표면특성은 BET와 X선 광전자 분광기(XPS)를 통해 각각 확인하였다. ACFs의 함산소불화 처리는 ACFs의 표면에 중금속 흡착 능력에 영향을 미치는 C-O 결합의 비율을 크게 증가시켰으며, 그 결과 $Cr^{6+}$ 흡착이 10 min 이내에 빠르게 평형에 도달할 수 있었다. 또한 초기 $Cr^{6+}$ 농도 20 ppm에서 최대 $Cr^{6+}$ 제거효율은 미처리 ACFs와 비교하여 약 100% 증가하였다. 이러한 결과로부터 ACFs의 함산소불화 반응은 저농도 $Cr^{6+}$의 흡착을 위한 표면처리법으로 응용될 수 있을 것이다.

시멘트 6가 크롬 (Cr(VI))정량분석법에 관한 고찰 - 분석과정에서 Cr(VI) 의 환원에 따른 오차제어- (Reduction of hexavalent chromium (Cr(VI)) under acidic conditions during its determination in cement)

  • 문세흠;정재홍;이승훈;이승헌
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.897-900
    • /
    • 2008
  • 시멘트내 6가 크롬의 분석은, 산성조건에서 6가 크롬이 디페닐카르바지드(DPC)와 결합하여 적자색의 착화합물을 형성하는 것을 원리로 한다. 그러나 6가 크롬은 산성조건에서 강한 산화력을 가지고 있기 때문에 철, 황화물, 유기물 등이 존재하는 경우 해당물질을 산화시키고 3가로 환원된다. 시멘트에는철, 황화물 등의 다양한 환원물질이 존재하기 때문에 분석과정에서 6가 크롬이 과소측정될 가능성이있다. 본 논문에서는 최근 제정된 "시멘트 중 6가 크롬의 정량분석 방법 (KS L 5221)"의 근간이 되는 JCAS I-51 실험방법 중 황산첨가 후 DPC 첨가의 경과시간에 따른 6가 크롬의 실험오차에 대해 검증하였다. 실험결과 황산첨가 후 시간이 경과함에 따라 측정되는 6가 크롬의 농도가 감소하였으며 감소효과는 시멘트마다 다르게 나타내었다. 인위적으로 용출액에 크롬을 첨가한 후 회수율을 측정한 결과, 산-DPC를 동시에 투입한 경우 $94.3{\sim}106.7$%의 회수율을 나타내었다.

  • PDF

중간층 조건에 따른 Cr-Mo-N 막의 상형성 및 마찰마모 거동 연구 (Tribology and Phase Evolution of Cr-Mo-N Coatings with Different Interlayer Condition)

  • 양영환;여인웅;박상진;임대순;오윤석
    • 한국표면공학회지
    • /
    • 제44권6호
    • /
    • pp.269-276
    • /
    • 2011
  • Phase evolution and tribological behavior of Cr-Mo-N multi compositional films with different interlayer were investigated. The films were deposited by hybrid PVD (Physical Vapor Deposition) system consisted of dc unbalanced magnetron (UBM) sputtering and arc ion plating (AIP) sources. A pure molybdenum (Mo) was used as sputtering target and also a pure Cr was used as AIP target to form the Cr-Mo-N films. Various growth planes were found, no textured surface, in all of the multi composition films. Maximum value of microhardness was measured in Cr-Mo-N film with Mo interlayer as 29 GPa. Composition film was mainly showed the aspect of the adhesive wear than CrN film. The friction coefficient was decreased from 0.6 for pure CrN coating to 0.35 for Cr-Mo-N film with Mo interlayer. This result may come from the formation of metal oxide tribo-layer which is known as solid lubricant during the wear test.