• Title/Summary/Keyword: $Cl^-$-ISEs

Search Result 2, Processing Time 0.016 seconds

An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes

  • Cho, Woo Jae;Kim, Dong-Wook;Jung, Dae Hyun;Cho, Sang Sun;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.75-84
    • /
    • 2016
  • Purpose: In-situ water quality monitoring based on ion-selective electrodes (ISEs) is a promising technique because ISEs can be used directly in the medium to be tested, have a compact size, and are inexpensive. However, signal drift can be a major concern with on-line management systems because continuous immersion of the ISEs in water causes electrode degradation, affecting the stability, repeatability, and selectivity over time. In this study, a computer-based nitrate monitoring system including automatic electrode rinsing and calibration was developed to measure the nitrate concentration in water samples in real-time. Methods: The capabilities of two different types of poly(vinyl chloride) membrane-based ISEs, an electrode with a liquid filling and a carbon paste-based solid state electrode, were used in the monitoring system and evaluated on their sensitivities, selectivities, and durabilities. A feasibility test for the continuous detection of nitrate ions in water using the developed system was conducted using water samples obtained from various water sources. Results: Both prepared ISEs were capable of detecting low concentrations of nitrate in solution, i.e., 0.7 mg/L $NO_3-N$. Furthermore, the electrodes have the same order of selectivity for nitrate: $NO_3{^-}{\gg}HCO_3{^-}$ > $Cl^-$ > $H_2PO_4{^-}$ > $SO{_4}^{2-}$, and maintain their sensitivity by > 40 mV/decade over a period of 90 days. Conclusions: The use of an automated ISE-based nitrate measurement system that includes automatic electrode rinsing and two-point normalization proved to be feasible in measuring $NO_3-N$ in water samples obtained from different water sources. A one-to-one relationship between the levels of $NO_3-N$ measured with the ISEs and standard analytical instruments was obtained.

Synthesis of Azo-functionalized Calix[4]arenes and Its Application to Chloride-selective Electrode as Ionophores

  • Lee, Hyo-Kyoung;Yeo, Hee-Kyoung;Park, Duck-Hee;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1737-1741
    • /
    • 2003
  • Azo-functionalized calix[4]arenes as ionophores for chloride-selective electrode, 5,11,17,23-Tetra-tert-butyl-25,27-bis[(N,N-dimethyl-aniline-azo-phenylthioureido)ethyl]oxy-26,28-dihydroxycalix[4]arene (4a) and 5,11,17,23-Tetra-tert-butyl-25,27-bis[(N,N-dimethyl-aniline-azo-phenylthioureido)ethyl]oxy-26,28-dimethoxycalix[4]arene (4b) were synthesized. The PVC membrane electrode based on azo-functionalized calix[4]arene 4a with o-NPOE exhibits a linear stable response over a wide concentration range ($1.5{\times}10^{-4}-1.0{\times}10^{-1}$) with a slope of -52.0 mV/decade and a detection limit of log[$Cl^-$] = -4.02. This ionophore-based membrane exhibited improved selectivity for chloride anion compared with classical Hofmeister series.