• 제목/요약/키워드: $C_P$(Power Coefficient)

검색결과 71건 처리시간 0.026초

Structural and Optical Properties of Copper Indium Gallium Selenide Thin Films Prepared by RF Magnetron Sputtering

  • Kong, Seon-Mi;Fan, Rong;Kim, Dong-Chan;Chung, Chee-Won
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.158-158
    • /
    • 2011
  • $Cu(In_xGa_{1-x})Se_2$ (CIGS) thin film solar cell is one of the most promising solar cells in photovoltaic devices. CIGS has a direct band gap which varied from 1.0 to 1.26 eV, depending on the Ga to In ratio. Also, CIGS has been studying for an absorber in thin film solar cells due to their highest absorption coefficient which is $1{\times}10^5cm^{-1}$ and good stability for deposition process at high temperature of $450{\sim}590^{\circ}C$. Currently, the highest efficiency of CIGS thin film solar cell is approximately 20.3%, which is closely approaching to the efficiency of poly-silicon solar cell. The deposition technique is one of the most important points in preparing CIGS thin film solar cells. Among the various deposition techniques, the sputtering is known to be very effective and feasible process for mass production. In this study, CIGS thin films have been prepared by rf magnetron sputtering method using a single target. The optical and structural properties of CIGS films are generally dependent on deposition parameters. Therefore, we will explore the influence of deposition power on the properties of CIGS films and the films will be deposited by rf magnetron sputtering using CIGS single target on Mo coated soda lime glass at $500^{\circ}C$. The thickness of CIGS films will be measured by Tencor-P1 profiler. The optical properties will be measured by UV-visible spectroscopy. The crystal structure will be analyzed using X-ray diffraction (XRD). Finally the optimal deposition conditions for CIGS thin films will be developed.

  • PDF

근적외선 분광법을 이용한 돈분뇨 액비 성분분석기 개발을 위한 기초 연구 (Basic Study on the Development of Analytical Instrument for Liquid Pig Manure Component Using Near Infra-Red Spectroscopy)

  • 최동윤;곽정훈;박치호;정광화;김재환;송준익;유용희;정만순;양창범
    • 한국축산시설환경학회지
    • /
    • 제13권2호
    • /
    • pp.113-120
    • /
    • 2007
  • 본 시험은 근적외선분광법을 이용한 돈분뇨 액비의 질소, 인산, 칼리, 수분 및 유기물의 분석 가능성을 구명하고, 이를 활용한 분석기의 개발을 목적으로 수행하였으며, 그 결과는 다음과 같다. 1. 돈분뇨 액비시료는 $400{\sim}2,500nm$ 대역의 근적외선을 시료에 투과하여 측정하였으며, 동일시료에 대한 습식분석 결과, N, $P_2O_5,\;K_2O$, 수분 및 유기물 함량은 각각 1,555mg/l, 302mg/l, 240mg/l, 98.8%, 0.53%로 조사되었다. 2. 근적외선 분광광도법을 이용한 분석에서 N, $P_2O_5,\;K_2O$, 수분 및 유기물에 대한 RSQ ($r^2$, R, Coefficient of determination)는 각각 0.9190, 0.9749, 0.5046, 0.9883 및 0.9777이었고 SEC(Standard Error of Calibration)는 2.1649, 0.5019, 1.9252, 0.1180 및 0.0789였다. 3. 액비에 대한 이화학적 습식분석과 NIR 흡수스펙트럼 측정결과를 비교 분석하여 돈 분뇨 액비에 포함된 질소, 인산, 칼리, 수분 및 유기물 함량을 실시간으로 분석하고 액비 성분량을 자동 계산할 수 있는 알고리즘을 도입한 액비분석 프로그램을 작성하였다. 4. 액비 성분분석 시작기는 근적외선(NIR : Near InfraRed)을 받아들여 실시간으로 액비성분의 흡수율을 측정하는 광검출장치(NIR Spectrometer), 근적외선 Light Source로부터 나오는 빛을 반사시키는 반사경, 액비성분 분석용 시료를 넣어 측정하는 Cell Mount, $400{\sim}2,500nm$ 대역의 가시광선-근적외선을 방출하는 Tungsten halogen lamp, NIR Spectrometer와 Tungsten halogen lamp로 전압을 입력시켜 주는 Power Supply Module 및 전체를 Black Anodizing한 외형으로 구성되었다. 5. 실험결과, 칼리를 제외한 액비내 모든 성분이 광을 흡수하는 강도는 성분의 농도에 비례하였으며 원시 스펙트럼의 중첩 제거 및 빛의 산란보정을 통해 액비의 질소, 인산성분, 수분 및 유기물 함량을 측정하는데 효과적으로 이용할 수 있을 것으로 사료되며, 분광분석법을 이용한 액비성분 분석기 개발이 완료되면 현장에서 신속하고 정확한 분석이 가능할 것으로 판단된다.

  • PDF

수확시기에 따른 대학찰옥수수의 전분특성 (Starch Properties of Daehak Waxy Corn with Different Harvest Times)

  • 이상훈;황인국;김현영;이하규;이성희;우선희;이준수;정헌상
    • 한국식품영양과학회지
    • /
    • 제39권4호
    • /
    • pp.573-579
    • /
    • 2010
  • 대학찰옥수수의 수확시기에 따른 전분특성을 규명하기 위하여 수확적기, 전기(-4일) 및 후기(+4일) 옥수수로부터 분리된 전분의 수율, 효소적 소화율, 물결합력, 팽윤력, 용해도 및 점도를 살펴보았다. 수확시기별 대학찰옥수수 전분의 수율은 43.21~52.73% 범위로 수확시기가 늦어질수록 높게 나타났으며, 아밀로펙틴의 함량은 90.79~92.83% 범위에서 증가하였다. 수확시기가 늦어짐에 따라 전분의 효소적 소화율과 용해도는 각각 81.43에서 80.58%와 10.23에서 9.23%로 감소하였으나, 전분의 물결합력과 팽윤력은 각각 227.94에서 244.88%와 24.75%에서 29.74%로 증가하였다. 점도는 최초 측정온도인 $90^{\circ}C$에서는 큰 차이가 없었으나, 전분 겔이 노화됨에 따라 점도는 증가하였으며, 수확시기가 늦어질수록 점도는 낮게 나타났다. 전분특성 관련 인자들 사이의 상관관계를 분석한 결과 높은 양 또는 음의 상관관계를 보였으며(p<0.01), 아밀로펙틴의 함량이 높을수록 효소적 소화율, 용해도 및 노화점도는 감소하였으나, 물결합력과 팽윤력은 증가하였다.

분할접합비에 따른 (Pb,Sn)Te/(Bi,Sb)2Te3 경사기능소자의 열전발전특성 (Thermoelectric Power Generation Characteristics of the (Pb,Sn)Te/(Bi,Sb)2Te3Functional Gradient Materials with Various Segment Ratios)

  • 이광용;현도빈;오태성
    • 한국재료학회지
    • /
    • 제12권12호
    • /
    • pp.911-917
    • /
    • 2002
  • 0.5 at% $Na_2$Te-doped ($Pb_{0.7}Sn_{0.3}$)Te and ($Bi_{0.2}Sb_{0.8}$)$_2$$Te_3$ powders were fabricated by mechanical alloying process. 0.5 at% Na$_2$Te-doped ($Pb_{0.7}Sn_{0.3}$)Te powders were charged at one end of mold and ($Bi_{0.2}Sb_{0.8}$)$_2$$Te_3$ powders were charged at the other end of a mold. Then these powders were hot-pressed to form p-type ($Pb_{0.7}Sn_{0.3}$)Te/($Bi_{0.2}Sb_{0.8}$)$_2$$Te_3$ functional gradient materials with the segment ratios (the ratio of ($Pb_{0.7}Sn_{0.3}$)Te to ($Bi_{0.2}Sb_{0.8}$)$_2$$Te_3$ ) of 1:2, 1:1, and 2:1. Power generation characteristics of the ($Pb_{0.7}Sn_{0.3}$)Te/($Bi_{0.2}Sb_{0.8}$)$_2$$Te_3$ were measured. When the temperature difference ΔT at both ends of the specimen was larger than $300^{\circ}C$, the ($Pb_{0.7}Sn_{0.3}$)Te/($Bi_{0.2}Sb_{0.8}$)$_2$$Te_3$ with the segment ratios of 1:2 and 1:1 exhibited larger output power than those of the ($Bi_{0.2}Sb_{0.8}$)$_2$$Te_3$ and 0.5 at% $Na_2$ Te-doped ($Pb_{0.7}Sn_{0.3}$)Te alloys. The maximum output power of the ($Pb_{0.7}Sn_{0.3}$)Te/($Bi_{0.2}Sb_{0.8}$)$_2$$Te_3$ predicted with the measured Seebeck coefficient and the estimated electrical resistivity was in good agreement with the measured maximum output power.

전계인가 진공 증착법으로 제작된$\beta$ -PVDF (Poly(vinylidene fluoride)) 박막의 초전 특성 (Pyroelectric Properties of the $\beta$-PVDF (Poly(vilnylidene fluoride)) Thin Film Prepared by Vacuum Deposition with Applying Electric Field)

  • 장동훈;강성준;윤영섭
    • 대한전자공학회논문지SD
    • /
    • 제39권5호
    • /
    • pp.23-30
    • /
    • 2002
  • 전계인가 진공증착법으로 β상을 가지는 PVDF (Polyvinylidene Fluoride) 박막을 제작한 후, dynamic 방법으로 초전 특성을 측정하여 초전형 적외선 센서의 응용가능성에 대하여 조사하였다. PVDF 박막의 응답특성이 저주파와 고주파 영역에 따른 변조 주파수의 주파수 분산 (dispersion)으로 고려되었고, 그에 따른 초전 특성의 주파수 의존성을 관찰하였다. 저주파 (2∼100㎐) 영역에서 분역의 재배향 (reorientation) 되는 속도는 변조주파수의 속도보다 빠르므로 분극의 변화량이 증가하여 최대 값을 나타낸다. 반면에 고주파 (100∼1000㎐) 영역에서 분역의 재배향은 주파수 증가에 따라 방해를 받아 분극의 변화량이 억제되어 초전 응답이 감소하는 것을 알 수 있다. 초전계수와 전압감도 및 비검출능을 위한 재료평가지수는 각각 3.2×10/sup -10/C/㎠·K, 2.34×10/sup -10/C·cm/J 1.32×10/sup -9/C·cm/J이었고, 잡음등가전력과 비검출능은 각각 1.66×10/sup -7/W/㎐/sup ½/, 6.03×10/sup 5/cm·㎐/sup ½/W로 나타났다.

발전소 취수구에 대량으로 유입하는 해양생물에 대한 스크린 설비의 성능분석 (Performance Analysis of Intake Screens in Power Plants on Mass Impingement of Marine Organisms)

  • 이재학;최현우;채진호;김동성;이승백
    • Ocean and Polar Research
    • /
    • 제28권4호
    • /
    • pp.385-393
    • /
    • 2006
  • Screening performance of the existing intake screens (drum and travelling screen) on mass impingement of marine animals, a euphausiid, Euphausia pacifica and a scyphozoan medusae, Aurelia aurita that have often clogged intake screens of the Uljin Nuclear Power Plant, was tested. The maximum tolerable densities of marine animals in the inflowing seawater upon the screen were estimated with two different approaches. First the maximum density of jellyfish was calculated from (1) passing amount of seawater per unit time through the screens and (2) the covered area of animals on the screens clogged. The maximum density of krill tolerable in the drum screen was cited from a simulated record of Uljin NPP, then those in the travelling screens were also calculated using the data of drum screen and ratio of seawater amount passing through the screens under the condition of 0.5m water column (W.C.) of the differential pressure (AP) produced by screens, an established permissible limit of ${\Delta}P$. Secondly, the screening performances were also tested by hydrodynamic measurements with various screen models in a circulating water channel equipped with a speed-controlling pump and a differential pressure gauge. From the first approach, the maximum tolerable densities of drum and travelling screen were calculated as 2.0 and $1.5ind/m^3$ for the Jellyfish and 900 and $680ind./m^3$ for the euphausiid, respectively. These densities estimated from the second approach were 2.1 and $0.8ind/m^3$ for the jellyfish and 1059 and $504ind/m^3$ for the euphausiid, respectively. These estimates were compared with the data from historic clogging events to evaluate the practical performance of these intake screens. The comparisons suggest a newly improved intake-screen of which performance should be at least seven times (approximately) better than the existing ones ior the krill and 3.2 times for the jellyfish, respectively, for preventing mass impingement, and for maintaining the condition of the differential pressure between the screens below 0.3 m W.C.

Electrochemical performance of double perovskite structured cathodes for intermediate temperature SOFCs

  • Jo, Seung-Hwan;Muralidharan, P.;Kim, Do-Kyung
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 춘계학술발표대회
    • /
    • pp.56.1-56.1
    • /
    • 2009
  • The intermediate operating temperature of solid oxide fuel cells (IT-SOFCs) have achieved considerable importance in the area of power fabrication. This is because to improve materials compatibility, their long-term stability and cost saving potential. However, to conserve rational cell performance at reduced-temperature regime, cathode performance should be obtained without negotiating the internal resistance and the electrode kinetics of the cell. Recently, double perovskite structure cathodes have been studied with great attention as a potential material for IT-SOFCs. In this study, double-perovskite structured cathodes of $GdBaCoCuO_{5+\delta}$, $GdBaCo_{2/3}Cu_{2/3}Fe_{2/3}O_{5+\delta}$ compositions and $(1-x)GdBaCo_2O_{5+\delta}+xCe_{0.9}Gd_{0.1}O_{1.95}$ (x = 10, 20, 30 and 40 wt.%) composites were evaluated as the cathode for intermediate temperature solid oxide fuel cells(IT-SOFCs). Electrical conductivity of the cathodes were measured by DC 4-probe method, and the thermal expansion coefficient of each sample was measured up to $900^{\circ}C$ by a dilatometer study. Area specific resistances(ASR) of the $GdBaCo_{2/3}Cu_{2/3}Fe_{2/3}O_{5+\delta}$ cathode and 70 wt.% $GdBaCo_2O5+\delta$ + 30wt.% Ce0.9Gd0.1O1.95 composite cathode on CGO electrolyte substrate were analyzed using AC 3-probe impedance study. The obtained results demonstrate that double perovskite-based compositions are promising cathode materials for IT-SOFCs.

  • PDF

Saccharification of Foodwastes Using Cellulolytic and Amylolytic Enzymes from Trichoderma harzianum FJ1 and Its Kinetics

  • Kim Kyoung-Cheol;Kim Si-Wouk;Kim Myong-Jun;Kim Seong-Jun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제10권1호
    • /
    • pp.52-59
    • /
    • 2005
  • The study was targeted to saccharify foodwastes with the cellulolytic and amylolytic enzymes obtained from culture supernatant of Trichoderma harzianum FJ1 and analyze the kinetics of the saccharification in order to enlarge the utilization in industrial application. T. harzianum FJ1 highly produced various cellulolytic (filter paperase 0.9, carboxymethyl cellulase 22.0, ${\beta}$-glucosidase 1.2, Avicelase 0.4, xylanase 30.8, as U/mL-supernatant) and amylolytic (${alpha}$-amylase 5.6, ${\beta}$-amylase 3.1, glucoamylase 2.6, as U/mL-supernatant) enzymes. The $23{\sim}98\;g/L$ of reducing sugars were obtained under various experimental conditions by changing FPase to between $0.2{\sim}0.6\;U/mL$ and foodwastes between $5{\sim}20\%$ (w/v), with fixed conditions at $50^{\circ}C$, pH 5.0, and 100 rpm for 24 h. As the enzymatic hydrolysis of foodwastes were performed in a heterogeneous solid-liquid reaction system, it was significantly influenced by enzyme and substrate concentrations used, where the pH and temperature were fixed at their experimental optima of 5.0 and $50^{\circ}C$, respectively. An empirical model was employed to simplify the kinetics of the saccharification reaction. The reducing sugars concentration (X, g/L) in the saccharification reaction was expressed by a power curve ($X=K{\cdot}t^n$) for the reaction time (t), where the coefficient, K and n. were related to functions of the enzymes concentrations (E) and foodwastes concentrations (S), as follow: $K=10.894{\cdot}Ln(E{\cdot}S^2)-56.768,\;n=0.0608{\cdot}(E/S)^{-0.2130}$. The kinetic developed to analyze the effective saccharification of foodwastes composed of complex organic compounds could adequately explain the cases under various saccharification conditions. The kinetics results would be available for reducing sugars production processes, with the reducing sugars obtained at a lower cost can be used as carbon and energy sources in various fermentation industries.

약쑥엑스제 쑥뜸방식에 의한 체간 온도 변화와 당뇨병 임상에 관한 연구 (A Study on the Variations of the Trunk Temperature and the Clinical Test for the Diabetics by the Artemisia Extract Moxibustion Method)

  • 윤동업;조봉관;배종일;구자성;김종원;이현민;조훈석;신우진;서상호;박동일;홍상훈
    • 대한한의학회지
    • /
    • 제27권1호
    • /
    • pp.165-183
    • /
    • 2006
  • Objectives : We implemented the Artemisia Extract Moxibustion Method and had the clinical tests for the diabetes with it. Methods : We implemented Artemisia extract made by extracting the vasodilator and antioxidant compounds from Artemisia-CH2C12 fraction and the moxibustion method constructed with DC Power supply, controller, Artemisia pad. single and multiple heating terminal with PTC(Positive Temperature Coefficient) thermistor. And we performed to estimate the efficiency on the questionnaire and the clinical tests with 23 cases of the diabetics. Results : We have estimated the improvement over 60% the symptoms that were the upper and lower limbs pain, frequent urination, spontaneous perspiration, thirst, decrease of body weight, and malaise after the moxibustion treatment on 5 cases among 23 cases. And the 19 cases took the biochemical check-up after the moxibustion treatment. From the results of biochemical check-up, the average HbAlc of before treatment was 8.400%, and after treatment 7.632%. The average HbAlc was decreased significantly after treatment (P<0.001). And the average urinary blood of before treatment was 0.73 and after treatment 0.27. The average urinary blood was decreased significantly after treatment (P<0.001). In addition the average FBS before treatment was 182.64 mg/dl, after treatment 161.77 mg/dl. Conclusions : We could estimate that our proposed moxibustion method was a significant treatment method for the diabetes.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF