• Title/Summary/Keyword: $C_{}$ f(mean)/

Search Result 485, Processing Time 0.032 seconds

A Study on the Quality Assuranc of Chemical Analysis Data of Precipitation Samples (강수 분석자료의 신뢰성 검토에 관한 연구)

  • 강공언
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.85-98
    • /
    • 1995
  • In order to ensure that all major cations and anions were accurately measured, the quality assurance checks of chemical analysis data by considering ion and conductivity balance of each precipitation sample were performed. To check the quality assurance of chemical analysis data, precipitation samples were collected by wet- only precipitation sampler at Seoul site and their chemical components were analyzed. By checking the problems for the screening methods of chemical analysis data used until recently, the f value expressed as the ratio of the sum of cations and anions equivalent concentration( $\Sigma $C/$\Sigma $A ) was found to be not ap priorate for data screening. Also, the scattering plot between cation and anion equivalent concentrations in each sample was found to show the general tendency of ion balance but was proved to not quantitate the standard of data screening at a set of samples of various concentration levels.4 more appropriate value was therefore required, h value is defined as (A-C)/C for C≥A and ( A-C)/A for C<4. This value was showed to check the ion balance in a viewpoint of quantitative as well as qualitative and to be useful in applying this expression to a measurement data set. However, the standard o( data screening must vary in response to the ion concentration of sample. In this study, the quality assurance of chemical analysis data was checked by considering both the ion balance evaluating by h value and the electrical conductivity. As these quality assurance checks were applied to Seoul data serf 67 valid samples were obtained. The result of statistical summary in the analytical parameter of precipitation samples collected for a certain period was found to be computed in the precipitation volume- weighted mean( VWM) rather than the arithmetic mean( AM), but PH In the VWM of hydrogen ion concentration. The annual VWM of pH values was 5.0(4.9 ∼ 5.1).

  • PDF

Studies on Genetic Analysis by the Diallel Crosses in $F_2$ Generation of Cowpea(Vigna sinensis savi.) (동부 Diallel Cross$ F_2$세대의 유전분석에 관한 연구)

  • Kim, J.H.;Ko, M.S.;Chang, K.Y.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.28 no.2
    • /
    • pp.216-226
    • /
    • 1983
  • Genetic studies on the $F_2$ generation of a set of half diallel crosses involving six cowpea varieties were conducted. by the randomized block design with three replications to determine combining ability, gene action and the relationships between parents and their $F_2$ hybrids. The 12 agronomic characters namely, days to flowering, days from flowering to maturity, days to maturity, diameter of stem, length of internode, number of branches per plant, length of pod, number of pods per plant, number of grains per pod, number of grains per plant, 100 grain weight and grain weight per plot were observed, and the $F_2$ generation of this diallel set of crosses was analysed for each character according to the method by Jinks and Hayman. The results obtained are summarized as follows: 1. Vr-Wr graphical analyses; The following seven characters, days to flowering, number of branches per plant, length of pod, number of pods per plant, number of grains per plant, 100 grain weight and grain weight per plot appeared to be partially dominant, and over dominance was found for days from flowering to maturity, days to maturity, length of internode and number of grains per pod. But diameter of stem indicated partial dominance near complete dominance. 2. Estimates of genetic variance components; In the degree of dominance,. eight characters, that is, days to flowering, days from flowering to maturity, days to maturity, length of internode, number of pods per plant, number of grains per pod, number of grains per plant and grain weight per plot were expressed larger than 1. And the characters, days from flowering to maturity, number of branches per plant and number of grains per plant as the degree of mean dominance ($H_1$/D) were found to be negative value over other characters. On the other hand, apprent asymmetry of dominance-recessive allele ($H_2$ /$4H_1$) produced comparatively estimates with lower value on days from flowering to maturity, length of internode, number of branches per plant and number of grains per pod. 3. Analyses of combining ability; Mean square value of GCA(general combining ability) appeared to be more important than those of SCA (specific combining ability) for most characters, and among them, grain weight per plot showed the highest mean square value in GCA and SCA. 4. Effect of combining ability; Variety 178 was expressed as the highest GCA effects in five characters (days to flowering days to maturity, number of pods per plant, number of grains per plant and grain weight per plot). SCA effects were differed from parents, characters and crosses, but crosses between TVu 1857 $\times$ TVu 2885 and TVu 2702 $\times$ J78 were shown to be highly with SCA effects on yield.

  • PDF

Chemical and Bacteriological Water Qualify of the Sonakdong River (서낙동강 강수의 화학적${\cdot}$세균학적 수질)

  • KIM Yong Gwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.4
    • /
    • pp.347-355
    • /
    • 1986
  • The Sonakdong river is very important water source not only for agricultural water of Kimhae field but also for fishery water. Recently the middle and lower areas of the river have the tendency to be heavily contaminated by domestic sewage and agricultural chemicals. Fifty six water samples were collected from 8 stations from July to December in 1985 for the experiment (Fig. 1). To evaluate the water quality, pH, water temperature, electrical conductivity, chloride ion, nutrients ($NO^{-}_{2}-N,\;NO^{-}_{3}-N,\;NH^{+}_{4}-N,\;PO^{3-}_{4}-P,\;SiO_2-Si$), total coliform, fecal coliform, and fecal streptococcus were determined. Range and mean value of the samples were as follows; pH $6.3{\sim}9.4$, 7.91; water temperature $6.1{\sim}34.8^{\circ}C,\;23.88^{\circ}C$; electrical conductivity (from St. A to G) $1.575{\times}10^2{\sim}30.50{\times}10^2{\mu}{\mho}/cm,\;6.57{\times}10^2{\mu}{\mho}/cm$; chloride ion $23.5{\sim}14,300mg/l$, 770.0mg/l; nitrite-nitrogen $0.007{\sim}0.110mg/l$, 0.053mg/l; nitrate-nitrogen $0.001{\sim}1.638mg/l$, 0.649 mg/l; ammonia-nitrogen $0.017{\sim}4.200mg/l$, 0.497mg/l; phosphate-phoshorus $0.011{\sim}0.281mg/l$, 0.086mg/l; and silicate-silicious $2.4{\sim}6.5mg/l$, 4.43mg/l. Electrical conductivity and chloride ion of the station F(Chomanpo) were $2.676{\times}10^2{\mu}{\Omega}cm$ and 123.99mg/l which were lower than those of others. Among the analyzed nutrients, silicate-silicious concentration was the highest through all the samples. The bacterial density of the samples ranged $36{\sim}110,000/100ml$ for total coliform, $15{\sim}46,000/100ml$ for fecal coliform and $3.6{\sim}15,000/100ml$ for fecal streptococcus. The range and the mean of the TC/FC ratio were $3.0{\sim}9.6$, 5.51 and those of the FC/FS ratio were $1.1{\sim}9.2$, 6.19, respectively. On the other hand, fecal coliform was not detected in about $78\%$ of the water samples examined. Composition of coliform was $52\%$ Escherichia coli group, $3\%$ Citrobacter freundii group, $13\%$ Enterobacter aerogenes group and $31\%$ others.

  • PDF

Energy efficient joint iterative SIC-MMSE MIMO detection (에너지 효율적 반복 SIC-MMSE MIMO 검출)

  • Ngayahala, F.C. Kamaha;Ahmed, Saleem;Kim, Sooyoung
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.1
    • /
    • pp.22-28
    • /
    • 2015
  • In this paper, we propose a new computationally efficient joint iterative multi-input multi-output (MIMO) detection scheme using a soft interference cancellation and minimum mean squared-error (SIC-MMSE) method. The critical computational burden of the SIC-MMSE scheme lies in the multiple inverse operations of the complex matrices. We find a new way which requires only a single matrix inversion by utilizing the Taylor series expansion of the matrix, and thus the computational complexity can be reduced. The computational complexity reduction increases as the number of antennas is increased. The simulation results show that our method produces almost the same performances as the conventional SIC-MMSE with reduced computational complexity.

An experimental study on the characteristics of the swirl ratio distribution with an intake port geometry (흡기포트 형상에 따른 선회비 분포특성에 관한 실험적 연구)

  • Lee, Ji-Geun;Ju, Bong-Cheol;No, Byeong-Jun;Gang, Sin-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.6
    • /
    • pp.725-734
    • /
    • 1997
  • The effect of helical intake port geometry on in-cylinder swirl flow characteristics was studied. Two helical intake ports were selected to change swirl ratio, mean flow coefficient with the variation of valve lifts, valve eccentricity ratios and axial distance. The measurements were made by using an impulse swirl meter. The port B modified to increase the swirl ratio( $R_{s}$) had the tendency of the increased non-dimensional rig swirl ( $N_{r}$) distribution in comparison with that of the port A. And the $N_{r}$ distribution was remarkably improved at low valve lifts. The modification of the geometry to increase the swirl ratio ( $R_{s}$) in helical intake port resulted in the decrease of the mean flow coefficient ( $C_{f(mean)}$) regardless of valve eccentricity ratio ( $N_{y}$). And also non-dimensional rig swirl ( $N_{r}$) in the high valve lift affected the calculation of swirl ratio considerably.onsiderably.

Distributions of the velocity and pressure of the pulsatile laminar flow in a pipe with the various frequencies (주파수의 변화에 따른 원형관로내 층류맥동유동의 속도와 압력의 분포)

  • Bae, S.C.;Mo, Y.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.561-571
    • /
    • 1997
  • In this paper, the fundamental equations are developed for the pulsatile laminar flow generated by changing the oscillatory flow with $0{\leq}f{\leq}48Hz$ into a steady one with $0{\leq}Re{\leq}2500$ in a rigid circular pipe. Analytical solutions for the wave propagation factor k, the axial distributions of cross-sectional mean velocity $u_m$ and pressure p are schematically derived and confirmed experimentally. The axial distributions of centerline velocity and pressure were measured by using Pitot-static tubes and strain gauge type pressure transducers, respectively. The cross-sectional mean velocity was calculated from the centerline velocity by applying the parabolic distribution of the laminar flow and it was confirmed by using the ultrasonic flowmeter. It was found that the axial distributions of cross-sectional mean velocity and pressure agree well with theoretical ones and depend only on the Reynolds number Re and angular velocity $\omega$.

  • PDF

In vitro and in vivo Antibacterial Activities and Pharmacokinetics of 8-Fluorociprofloxacin and Ciprofloxacin (8-Fluorociprofloxacin과 Ciprofloxacin의 시험관내 및 생체내 항균효과와 약물동태의 비교)

  • 최경업;정용환;김제학
    • YAKHAK HOEJI
    • /
    • v.37 no.3
    • /
    • pp.235-242
    • /
    • 1993
  • 8-Fluorociprofloxacin(8-FCP) is an investigational quinolone derivative that is substituted with fluorine at the C-8 position of ciprofloxacin(CP). It was found that the in vitro activity of 8-FCP against Gram(+) bacteria was more potent that of CP, but the opposite against Gram(-) bacteria was true. However, 8-FCP showed better in vivo efficacy than CP against representative Gram(-) organisms, E. coli and K pneumoniae. In an attempt to seek for factors causing this discrepancy in the antibacterial activities, a comparative pharmacokinetic study of 8-FCP and CP was conducted in mice and rats treated either intravenously or orally at a single dose of 30 mg/kg. The pharmacokinetic parameters in mice were as follows; the mean peak serum concentrations(C$_{max}$) following i.v. and oral doses were 12.4 and 5.3 $\mu\textrm{g}$/ml for 8-FCP, and 9.5 and 2.5 $\mu\textrm{g}$/ml for CP, respectively. The terminal half-life(t$_{1/2\beta}$) was 72.9 min for 8-FCP, and 98.2 min for CP, and the oral bioavailability(F) was 89.9% for 8-FCP, and 50.5% for CP. In rats, the mean ($\pm$SD) $C_{max}$ after i.v. administration were 11.6$\pm$1.6 $\mu\textrm{g}$/ml for 8-FCP, and 10.2$\pm$1.3 $\mu\textrm{g}$/ml for CP, whereas oral administration produced $C_{max}$ of 5.9$\pm$1.8 $\mu\textrm{g}$/ml for 8-FCP and 1.1$\pm$0.9 $\mu\textrm{g}$/ml for CP, respectively. The t$_{1/2\beta}$ was 67.9$\pm$8.4 min for 8-FCP, and 76.4$\pm$7.2 min for CP. The F was 88.6$\pm$6.3% for 8-FCP, and 40.7$\pm$6.5% for CP. Marked differences were observed between the two quinolones in the $C_{max}$ and the area under the concentration-time curve obtained after oral administration in mice and rats. The extent of 8-FCP absorption in both mice and rats was approximately 2-fold higher than that of CP, suggesting that the fluorine atom attached to C-8 plays an important role in facilitating oral absorption from the gastrointestinal tract.

  • PDF

A Study on Job Stress, Fatigue and Job Satisfaction of 119 Emergency Medical Technician (119구급대원의 업무스트레스와 피로 및 직무만족도에 관한 연구)

  • Park, Dae-Sung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.8 no.1
    • /
    • pp.71-86
    • /
    • 2004
  • This study selected emergency medical technicians at 24 fire police boxes in Jeonnam in order to examine the relationship between job stress, fatigue and job satisfaction of 119 emergency medical technicians. Data were collected from Apr. 10 to May 9, 2004, questionnaires were mailed and returned by mail. Total 109 questionnaires were distributed and 89 questionnaires were collected and 80 except 9 omitting answers and showing inappropriate answers were used for final analysis. The results of this study are as follows. A. The total mean of areas composing job stress in the degree of job stress of 119 emergency medical technicians was over the average as 2.54 (SD .44) of 4 full marks. According to the degree of job stress by each area, the highest area of job stress was crisis situation (2.98), followed by role conflict as professional job (2.58), social factors (2.57), involvement in organization (2.55). To the contrary, the areas of the lowest job stress were professional knowledge and technique (2.35), psychological burden of medical limitation (2.38), conflicts in personal relationship and services (2.45) and improper treatment (2.53). B. The degree of fatigue of 119 emergency medical technicians by areas was over mean as 2.09(SD .49) of 4 full scores and physical fatigue was highest (2.18), followed by mental fatigue (2.11) and neurosensory fatigue (1.99). C. The degree of job satisfaction of 119 emergency medical technicians was 2.71 of 5 full scores and working condition area (3.70) showed the highest job satisfaction, followed by requirement of organization (2.85) and the lowest job satisfaction area was job itself (2.18), followed by desire for job (2.49). D. According to differences in demographical characteristics of 119 emergency medical technicians, there was no variable of statistical difference at job stress and job satisfaction in significance level .05, but fatigue showed statistical difference at final education (F=2.393, p=.046). E. According to differences related to job characteristics of 119 emergency medical technicians, job stress showed statistical differences at motif of current services (F=4.935, p=.003), fatigue showed those at health conditions (F=2.732, p=.008), job satisfaction at overtime (F=3.038, p.034) and the greatest reason of having job (F=3.217, p=.017), F. As a result of analyzing correlations between job stress. fatigue and job satisfaction of the subject, job stress showed positive correlations (r=.411, p=.000) with fatigue and negative correlation (r=-.267, p=.008) with job satisfaction. Fatigue showed negative correlation (r=-.287, p=.005) with job satisfaction. Therefore, the hypothesis of this study. "There will be relationship between degree of stress, fatigue and job satisfaction of subjects." was supported.

  • PDF

Effects of Genetic Variants of ${\kappa}$-casein and ${\beta}$-lactoglobulin and Heat Treatment of Milk on Cheese and Whey Compositions

  • Choi, J.W.;Ng-Kwai-Hang, K.F.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.5
    • /
    • pp.732-739
    • /
    • 2002
  • Milk samples with different phenotype combination of $\{kappa}$-casein and ${\beta}$-lactoglobulin and different preheating temperatures of 30, 70, 75 and $80^{\circ}C$ were used for cheesemaking under laboratory conditions. For the 853 batches of cheese, mean composition was 59.64% total solids, 30.24% fat and 23.66% protein, and the whey contained 6.93% total solids, 0.30% fat and 0.87% protein. Least squares analysis of the data indicated that heating temperature of the milk and ${\kappa}$-CN/${\beta}$-LG phenotypes had significant effects on cheese and whey compositions. The total solids, fat and protein contents of cheese were negatively correlated with preheating temperatures of milk. Cheese from BB/BB phenotype milk had the highest and those from AA/AA phenotype milk had the lowest concentrations of total solids, fat and protein. Mean recoveries of milk components in the cheese were 53.71% of total solids, 87.15% of fat, and 80.32% of protein. For the 10 different types of milk, maximum recoveries of milk components in cheese occurred with preheating temperature of $70^{\circ}C$ or $75^{\circ}C$ and lowest recoveries occurred at $80^{\circ}C$. The whey averaged 6.94% total solids, 0.30% fat and 0.87% protein. Losses of milk components in the whey were lowest for milk preheated at $80^{\circ}C$ and for milk containing the BB/BB phenotype.

A New Multivariate System Process Capability Index (다변량 시스템 공정능력지수(SCpsk))

  • 조남호;이용훈
    • Journal of the Korea Safety Management & Science
    • /
    • v.5 no.3
    • /
    • pp.145-156
    • /
    • 2003
  • As we understand it, Process Capability indices are intended to provide single-number assessments of ability to meet specification limits on quality characteristics of interest. As a consequence of the varied ways in which PCIs are used, there have been two natural lines of research work: $\circled1$ studies on the properties of PCIs and their estimators in many different environments; $\circled2$ construction of new PCIs purporting to have better properties in certain circumstances. The most of existing process capability indices are concerned with the single variable. But, in many cases, a quality characteristic is composed with several factors. In that case, we want to know the integrated process capability of a quality characteristic not those of each factor. In this paper, we proposed a new multivariate system process capability index called $MSPCI:SC_{psk}$ which is the geometric mean of performance measure $C_{psk}$'S, and will be used as the criterion to assess multiple response process designs. Numerical illustration is done for $SC_{psk}$, $\overline{C_p}$(f), Cp, Cpk, Cpm, and Cpsk.