• Title/Summary/Keyword: $CO_2$sensor

Search Result 908, Processing Time 0.024 seconds

The Method of Thermograph using Thermoelectric Sensor Device in the Carbon fiber Thick Films (Carbon fiber 후막형 열전센서 소자를 이용한 적외선 체열진단)

  • Song, M.J.;Kim, M.H.;Ryu, S.M.;Lee, H.S.;Lee, W.J.;Park, C.B.;Choi, W.S.;Kim, T.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04b
    • /
    • pp.1-2
    • /
    • 2008
  • Thick films of Carbon fiber were prepared by a heating element of plan shape made in Darin co.. We have investigated surface morphology of the specimen depending on second heat-treatment temperatures. X-ray diffraction patterns of Carbon fiber thick films show that the specimen heat treated below $600^{\circ}C$ was an amorphous phase and the one heat treated above $1100^{\circ}C$ forms a poly-crystallization. Scanning electron microscope(SEM) image of Carbon fiber thick films of the specimen heat treated in between 900 and $1100^{\circ}C$ shows a grain growth. At $1100^{\circ}C$, the specimen stops grain-growing and becomes a poly-crystallization.

  • PDF

Smart Safety Belt for High Rise Worker at Industrial Field

  • Lee, Se-Hoon;Moon, Hyo-Jae;Tak, Jin-Hyun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.2
    • /
    • pp.63-70
    • /
    • 2018
  • Safety management agent manages the risk behavior of the worker with the naked eye, but there is a real difficulty for one the agent to manage all the workers. In this paper, IoT device is attached to a harness safety belt that a worker wears to solve this problem, and behavior data is upload to the cloud in real time. We analyze the upload data through the deep learning and analyze the risk behavior of the worker. When the analysis result is judged to be dangerous behavior, we designed and implemented a system that informs the manager through monitoring application. In order to confirm that the risk behavior analysis through the deep learning is normally performed, the data values of 4 behaviors (walking, running, standing and sitting) were collected from IMU sensor for 60 minutes and learned through Tensorflow, Inception model. In order to verify the accuracy of the proposed system, we conducted inference experiments five times for each of the four behaviors, and confirmed the accuracy of the inference result to be 96.0%.

Application and Verification of Fully-Integrated Design Environment for Piezoelectric Energy Harvester (압전형 에너지 수확장치를 위한 통합 해석환경의 적용 및 검증)

  • Liu, Jian;Welham, Chris;Han, Seungoh
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.364-368
    • /
    • 2013
  • Vibrational energy harvester based on piezoelectricity has been expected to be the dominant energy harvesting technology due to the advantages of high conversion efficiency, light weight and small size, night operation, etc. Its commercialization is just around the corner but the integration with power management electronics should be solved in advance. In this paper, therefore, fully-integrated design environment for piezoelectric energy harvesting systems is presented to assist co-design with the power management electronics. The proposed design environment is capable of analyzing the energy harvester including the package-induced damping effects and simulating the device and its power management electronics simultaneously. When the developed design environment was applied to the fabricated device, the simulated resonant frequency matched well with the experimental result with a difference of 2.97% only. Also, the complex transient response was completed in short simulation time of 3,001 seconds including the displacement distribution over the device geometry. Furthermore, a full-bridge power management circuit was modeled and simulated with the energy harvester simultaneously. Therefore the proposed, fully-integrated design environment is accurate and fast enough for the contribution on successful commercialization of piezoelectric energy harvester.

Development of Tank Lorry Monitoring System for Safety Using Intelligent Computing Device (지능형 단말기를 사용한 탱크로리 운행 안전 모니터링 시스템 개발)

  • Lee, Choon-Young;Bae, Ki-Man;Park, Geun-Young;Lee, Dong-Jin;Lim, Jeong-Sik;Lee, Sang-Ryong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.42-47
    • /
    • 2008
  • It is important for national safety that tank lorry or bulk lorry which is carrying toxic gas or explosive materials should be monitored during the maneuvering from starting point to destination as well as vehicle or tank status. Therefore, we propose a safety monitoring system for tank lorry to check driving condition and the vehicle status. We studied the integration of central control system with in-vehicle computer system connected with various sensors for monitoring through a communication network.

  • PDF

Development of a LoRaWAN-based Real-time Ocean-current Draft Observation System using a multi-GPS Triangulation Method Correction Algorithm (다중 GPS 삼각측량보정법을 이용한 LoRaWAN기반 실시간 해류관측시스템 개발)

  • Kang, Young-Gwan;Lee, Woo-Jin;Yim, Jae-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.64-68
    • /
    • 2022
  • Herein, we propose a LoRaWAN-based small draft system that can measure the ocean current flow (speed, direction, and distance) in real time at the request of the Coast Guard to develop a device that can promptly find survivors at sea. This system has been implemented and verified in the early stages of rescue after maritime vessel accidents, which are frequent. GPS signals often transmit considerable errors, so correction algorithms using the improved triangulation method algorithm are required to accurately indicate the direction of currents in real time. This paper is structured in the following manner. The introduction section elucidates rescue activities in the case of a maritime accident. Chapter 2 explains the characteristics and main parameters of the GPS surveying technique and LoRaWAN communication, which are related studies. It explains and expands on the critical distance error correction algorithm for GPS signals and its improvement. Chapter 3 discusses the design and analysis of small draft buoys. Chapter 4 presents the testing and validation of the implemented system in both onshore and offshore environments. Finally, Section 5 concludes the study with the expected impact and effects in the future.

Organopalladium(II) Complexes as Ionophores for Thiocyanate Ion-Selective Electrodes

  • Kim, Dong-Wan;Lee, So-Hyun;Kim, Jung-Hwan;Kim, Jin-Eun;Park, Jong-Keun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2303-2308
    • /
    • 2009
  • A thiocyanate poly(vinyl chloride) (PVC) membrane electrode based on [1,2-bis(diphenylphosphino)ethane]dihalopalladium( II), [(dppe)$PdX_2$, X = Cl ($L^1$), X = I ($L^2$)] as active sensor has been developed. The diiodopalladium complex, [(dppe)$PdI_2](L^2$) displays an anti-Hofmeister selectivity sequence: $SCN^-\;>\;I^-\;>\;{ClO_4}^-\;>\;Sal^-\;>\;Br^-\;>\;{NO_2}^-\;>\;{HPO_4}^-\;>\;AcO^-\;>\;{NO_3}^-\;>\;{H_2PO_4}^-\;>\;{CO_3}^{2-}$. The electrode exhibits a Nernstian response (-59.8 mV/decade) over a wide linear concentration range of thiocyanate ($(1.0\;{\times}\;10^{-1}\;to\;5.0\;{\times}\;10^{-6}$ M), low detection limit ($(1.1\;{\times}\;10^{-6}$ M), fast response $(t_{90%}$ = 24 s), and applicability over a wide pH range (3.5∼11). Addition of anionic sites, potassium tetrakis[p-chlorophenyl] borate (KTpClPB) is shown to improve potentiometric anion selectivity, suggesting that the palladium complex may operate as a partially charged carrier-type ionophore within the polymer membrane phase. The reaction mechanism is discussed with respect to UV-Vis and IR spectroscopy. Application of the electrode to the potentiometric titration of thiocyanate ion with silver nitrate is reported.

Via Cleaning Process for Laser TSV process (Laser TSV 공정에 있어서 Via 세정에 관한 연구)

  • Seo, Won;Park, Jae-Hyun;Lee, Ji-Young;Cho, Min-Kyo;Kim, Gu-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.1
    • /
    • pp.45-50
    • /
    • 2009
  • By Laser Through-Silicon-Via process, debris and particles occur when you are forming. Therefore the research of TSV cleaning become important to remove those particles and debris. Both chemical cleaning method that uses a surfactant and physical cleaning method that uses a brush were studied with the via of $30{\mu}m$ diameter and $100{\mu}m$ depth on the 8 inch CMOS Image Sensor wafer. On the DI water and a surfactant in mixture ratio of 2:1, debris show $73{\mu}m^2$ per $0.054mm^2$. Cleaning is superior by lower mixture ratio of DI water and surfactant. In addition, It is less than 5% of debris distribution in the laser condition changed by Laser's frequency and its speed and cleaning had no effect. In the physical cleaning, there are no crack and damage when the system condition is set by $1000{\sim}3000rpm$ strip, $50{\sim}3000rpm$ rinsing, and $200{\sim}300rpm$ brushing Therefore, debris and particles can be removed by enforced chemical method and physical method.

  • PDF

Study on the Enhanced Specific Surface Area of Mesoporous Titania by Annealing Time Control: Gas Sensing Property (열처리 시간에 따른 메조기공 타이타니아의 비표면적 향상 연구: 가스센싱 특성 변화)

  • Hong, M.-H.;Park, Ch.-S.;Park, H.-H.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.2
    • /
    • pp.21-26
    • /
    • 2015
  • Mesoporous ceramic materials were applied in various fields such as adsorbent and gas sensor because of low thermal conductivity and high specific surface area properties. This structure could be divided into open-pore structure and closed-pore structure. Although closed-pore structure mesoporous ceramic materials have higher mechanical property than open-pore structure, it has a restriction on the application because the increase of specific surface area is limited. So, in this work, specific surface area of closed-pore structure $TiO_2$ was increased by anneal time. As increased annealing time, crystallization and grain growth of $TiO_2$ skeleton structured material in mesoporous structure induced a collapse and agglomeration of pores. Through this pore structural change, pore connectivity and specific surface area could be enhanced. After anneal for 24 hrs, porosity was decreased from 36.3% to 34.1%, but specific surface area was increased from $48m^2/g$ to $156m^2/g$. CO gas sensitivity was also increased by about 7.4 times due to an increase of specific surface area.

Analysis of the Mean Uranium Valence of $U_{1-y}Er_{y}O_{2{\pm}x}$ Solid Solutions in terms of Lattice Parameter and Oneen Potential (격자상수 및 산소포텐샬에 의한 $U_{1-y}Er_{y}O_{2{\pm}x}$ 고용체의 평균우라늄원자가 분석)

  • Kim, Han-Soo;Sohn, Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.118-128
    • /
    • 1996
  • The lattice parameters of stoichiometric $UO_2$ and $U_{1-y}Er_{y}O_2$ in the range of y=0.01 to y =0.33 were determined with use of X-ray diffraction data. Oxygen potentials have been measured by means of a thermogravimetric method in the range of 1200~$1500^{\circ}C$ and $10^{-14}$ $\leq$ $Po_2$ $\leq$ $10^{-3}$ for pure $UO_2$ and $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions with y=0.02, y=0.06 and y=0.20, respectively. Their oxygen partial pressures were maintained by controlling $CO_2$/CO mixture atmosphere, and the $Po_2$ values corresponding to x of $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions were measured with an electrolyte oxygen sensor. The lattice parameter decreases linearly with an increase in the erbium content. The change of the lattice parameter can be expressed in a linear equation of y as a($\AA$) =5.4695-0.220y for 0 $\leq$y$\leq$0.33. The experimental coefficient of y -0.220 in $U_{1-y}Er_{y}O_2$ was an intermediate value between the calculated values -0.273 and -0.156 in the case of $U^{5+}$ and $U^{6+}$, respectively. The (equation omitted) has been found to undergo abrupt increase in the range of -360 to -270 kJ/mole for y=0.06 and -320 to -220 H/mole for y=0.20, respectively, in the temperature range of 1200-$1500^{\circ}C$. (equation omitted) increases with erbium content, but the effect of the dopant for x =0.01 is less significant than that for stoichiometry. The oxygen potentials for $UO_2$ and $U_{0.98}Er_{0.02}O_{2+x}$ can be approximately represented by the $U^{5+}$/$U^{4+}$ model but those for y$\geq$ 0.06 in $U_{1-y}Er_{y}O_{2{\pm}x}$ solid solutions cannot be interpreted by the mean uranium valence model.

  • PDF

Bio-monitoring System for Early Detection of Toxic Dinoflagellate Alexandrium pacificum Using the Shell Valve Movements of Bivalves (유독 와편모조류 Alexandrium pacificum의 조기 탐지를 위한 이매패류 패각운동 생물모니터링 시스템 연구)

  • Jeong, Soo Yong;Kim, Dae Hyun;Oh, Seok Jin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_3
    • /
    • pp.979-989
    • /
    • 2022
  • We examined changes in the shell valve movements (SVMs) of Mytilus edulis and Crassostrea gigas using a Hall element sensor to investigate the early detection of the toxic dinoflagellate Alexandrium pacificum. No increase or decrease was observed in SVMs caused by the non-toxic algae Isochrysis galbana in both M. edulis and C. gigas. However, when M. edulis and C. gigas were exposed to A. pacificum, which causes paralytic shellfish poisoning, the average SVMs for 12 hours before and after exposure increased from 1.25 times/hr to 2.13 times/hr and 2.23 times/hr to 8.91 times/hr, respectively. After exposure to A. pacificum, the SVMs of M. edulis increased rapidly within 1 hour and then decreased gradually. However, C. gigas showed high SVMs until 4 hours after exposure. SVMs of C. gigas appeared to be more sensitive to toxic dinoflagellate than those of M. edulis. Therefore, these results are expected to be used as basic data for the establishment of a biological monitoring system for early detection of the toxic dinoflagellate A. pacificum.