• Title/Summary/Keyword: $CO_2$emission rate

Search Result 386, Processing Time 0.024 seconds

Experimental Study on the Effect of $CO_2$ Feeding on the Oxygen Combustion Characteristics by using Inverse Type Multi-hole Burner (역확산 다공 연소기에서 $CO_2$ 첨가에 따른 순산소 연소 특성에 관한 실험적 연구)

  • Seo, Jeong-Il;Guahk, Young-Tae;Bae, Soo-Ho;Hong, Jung-Goo;Lee, Uen-Do;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.162-169
    • /
    • 2005
  • The performance of oxygen combustion with $CO_2$ feeding was investigated in a pyrex tube furnace. The inverse type multi-hole burner was used for improving mixing and wide operating range. It introduced oxygen, fuel, and oxygen, respectively, from center tube to outer tubes. Oxygen combustion characteristics with excess oxygen ratio, oxygen feeding ratio, and $CO_2$ feeding flow rate were studied to optimize the operating condition and to apply the oxygen combustion with recirculation of flue gas to a real furnace. This paper presents results on the effect of $CO_2$ feeding flow rate on the structure of the flames and concentrations of NO and CO emissions. The visible flame length was shortest due to well mixing between fuel and oxygen when the oxygen feeding ratio was 0.25. The NO emission was reduced drastically regardless of excess oxygen ratio when the $CO_2$ feeding flow rate was larger than 15 lpm. The CO emission is varied by changing the $CO_2$ feeding flow rate but the CO emission characteristics is highly affected by excess oxygen ratio. When the excess oxygen ratio is below ${\lamda}=1.1$, the CO emission increased as the $CO_2$ feeding flow rate increased.

  • PDF

Property Analysis of Municipal Solid Waste and Estimation of CO2 Emissions from Waste Incinerators (생활폐기물 특성 분석 및 소각시설의 CO2 배출량 평가)

  • Kim, Byung-Soon;Kim, Shin-Do;Kim, Chang-Hwan;Lee, Tae-Jung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.657-665
    • /
    • 2010
  • Carbon dioxide ($CO_2$) is known to be a major greenhouse gas partially emitted from waste combustion facilities. According to the greenhouse gas emission inventory in Korea, the quantity of the gas emitted from waste sector in 2005 represents approximately 2.5 percent of all domestic greenhouse gas emission. Currently, the emission rate of greenhouse gas from the waste sector is relatively constant partly because of both the reduced waste disposal in landfills and the increased amounts of waste materials for recycling. However, the greenhouse gas emission rate in waste sectors is anticipated to continually increase, mainly due to increased incineration of solid waste. The objective of this study was to analyze the property of Municipal Solid Waste (MSW) and estimate $CO_2$ emissions from domestic MSW incineration facilities. The $CO_2$ emission rates obtained from the facilities were surveyed, along with other two methods, including Tier 2a based on 2006 IPCC Guideline default emission factor and Tier 3 based on facility specific value. The $CO_2$ emission rates were calculated by using $CO_2$ concentrations and gas flows measured from the stacks. Other parameters such as waste composition, dry matter content, carbon content, oxidation coefficient of waste were included for the calculation. The $CO_2$ average emission rate by the Tier 2a was 34,545 ton/y, while Tier 3 was 31,066 ton/y. Based on this study, we conclude that Tier 2a was overestimated by 11.2 percent for the $CO_2$ emission observed by Tier 3. Further study is still needed to determine accurate $CO_2$ emission rates from municipal solid waste incineration facilities and other various combustion facilities by obtaining country-specific emission factor, rather than relying on IPCC default emission factor.

Estimation and Feature of Greenhouse Gas Emission in Building Sector by National Energy Statistic (국가 에너지통계에 따른 건물부문 온실가스 배출량 추계 및 특성)

  • Jeong, Young-Sun;Kim, Tae-Hyoung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.187-195
    • /
    • 2019
  • In December 2015, The Paris Agreement was adopted to undertake ambitious efforts to combat climate change. Korean government announced its goal of reducing the country's greenhouse gas emissions by up to 37% below business as usual projections by 2030 in 2015. The purpose of this study was to set up the calculation methodology of GHG emission($CO_{2e}$) in building sector and to estimate the annual GHG emission in building sector based on national energy consumption statistic. The GHG emission from buildings is about 135.8 million ton $CO_{2e}$ as of 2015, taking up about 19.6% of Korea's entire emission and is about 144.7 million ton $CO_{2e}$ in 2017. The GHG emission of building sector is increasing at annual rate of 2.0% from 2001 to 2017. The GHG emission from electricity consumption in buildings is 91.8 million ton $CO_{2e}$ in 2017, is the highest $CO_2$ emission by energy source. The results show that the intensity of GHG emission of residential building sector is $40.6kg-CO_{2e}/m^2{\cdot}yr$ and that of commercial building sector is $68.4kg-CO_{2e}/m^2{\cdot}yr$.

A Study on the Characteristics of Combustion for Substituting $CO_2\;for\;N_2$ in Combustion Air (연소용 공기중 $N_2$$CO_2$대체에 대한 연소특성 해석)

  • Kim, Han-Seok;Ahn, Kook-Young;Kim, Ho-Keun;Lee, Yun-Won;Lee, Chang-Eon
    • Journal of the Korean Society of Combustion
    • /
    • v.7 no.4
    • /
    • pp.29-35
    • /
    • 2002
  • [$CO_2$] is a well-known greenhouse gas, which is the major source of global warming. Many researchers have studied to reduce $CO_2$ emission in combustion processes. The central method of low $CO_2$ emission is Oxygen/CxHy combustion. Theoretically Oxygen/CxHy combustion only produces $CO_2\;and\;H_2O$ and allows convenient recovery of $CO_2$. The combustion characteristics, flame stability, composition in the flame zone and temperature profile were studied experimentally for various compositions of oxidant by substituting $CO_2\;for\;N_2$ with the constant $O_2$ concentration. Results showed that flame became unstable due to the high heat capacity, low transport rate and strong radiation effect of $CO_2$ in comparison with those of $N_2$. The reaction zone was quenched and broadened, as the ratio of $CO_2\;to\;N_2$ was increased. The emission of NOx in flue gas decreased due to the decreased temperature of the reaction zone. As the conversion ratio of $CO_2\;to\;N_2$ was increased, the emission of CO and the higher temperature zone increased due to decrease of reaction rate by the a quenching effect.

  • PDF

A CO2 Emission Reduction Method through Correlation Analysis of Design Parameters in Buildings (건축물 설계변수의 상관관계 분석을 통한 CO2 배출저감 방안)

  • Lee, Hyun-Woo;Chae, Min-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.100-106
    • /
    • 2011
  • This study proposes a $CO_2$ emission reduction method through correlation analysis of a sample building. First, energy saving factors of heating, cooling, lighting were determined for the correlation analysis and $CO_2$ emission contribution rate of the design parameters have been analyzed. Then optimal combination of each design parameter has been drawn. Heat transfer coefficient of walls and windows, air permeability, windows area ratio, and shading devices were selected as applicable energy saving factors of the sample building. Also computer simulation was conducted using experimental design by Orthogonal Arrays of the statistical method. And the contribution rate was estimated by Analysis of Variance-ANOVA. As a result, the $CO_2$ emission in heating was reduced to 51.9%; in cooling to 16.8%; and in lighting to 2% compared to the existing building. The majority of the reduction was presented by heating energy.

Characteristics for Effects of Co2 Addition to Oxygen-Enriched Combustion (산소부화연소에서 Co2 첨가에 대한 연소 특성)

  • Kim, Han-Seok;Kim, Ho-Keun;Ahn, Kook-Young;Kim, Yong-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.1
    • /
    • pp.9-15
    • /
    • 2004
  • $CO_2$ is a well-known green house gas as well as the major source of global warming. Many researchers have studied to reduce $CO_2$ emission in combustion processes. Among the method for reducing $CO_2$ emission, oxygen-enriched combustion has been proposed. Because its adiabatic flame temperature is relatively too high, existing facilities must be changed or the flame temperature in the combustion zone should be reduced. The combustion characteristics, composition in the flame zone, temperature profile and emission gases were investigated experimentally for the various oxygen-enriched ratios(OER) by the addition of $CO_2$, under constant $O_2$ flow rate. Results showed that the reaction zone was quenched and broadened as the addition of $CO_2$ was increased. The emission of NOx in flue gas was decreased as decreasing temperature in reaction zone. It was also shown that the reaction was delayed by the cooling effect. As the addition of $CO_2$ was increased, the composition of CO in the flame zone was increased due to the increase of reaction rate by increasing mixing effect of oxidant/fuel at OER=0%, but the composition of CO was decreased by quenching effect at OER=50% and 100%.

A Study of NO Fmission Characteristics in a Non-premixed Counterflow Flame with $H_2/CO_2/Ar$ Blended-fuel (수소/이산화탄소/알곤 혼합 연료의 비예혼합 대향류 화염에서 NO 배출 특성 연구)

  • Lee, Kee-Man
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.4
    • /
    • pp.146-153
    • /
    • 2007
  • The detailed chemistry with reaction mechanism of GRI 2.11, which consists of 49 species and 279 elementary reactions, have been numerically conducted to investigate the flame structure and NO emission characteristics in a non-premixed counterflow flame of blended fuel of $H_2/CO_2/Ar$. The combination of $H_2,\;CO_2$, and Ar as fuel is selected to clearly display the contribution of hydrocarbon products to flame structure and NO emission characteristics due to the breakdown of $CO_2$. Radiative heat loss term is involved to correctly describe the flame dynamics especially at low strain rates. All mechanisms including thermal, $NO_2,\;N_2O$, and Fenimore are also taken into account to separately evaluate the effects of $CO_2$ addition on NO emission characteristics. The increase of added $CO_2$ quantity causes flame temperature to fall since at high strain rates diluent effect is prevailing and at low strain rates the breakdown of $CO_2$ produces relatively populous hydrocarbon products and thus the existence of hydrocarbon products inhibits chain branching. It is also found that the ratio of the contribution by Fenimore mechanism to that by thermal mechanism in the total mole production rate becomes much larger with increase in the $CO_2$ quantity and strain rate, even though the absolute quantity of NO production is deceased. Consequently, as strain rate and $CO_2$ quantity increase, NO production by Fenimore mechanism is remarkably augmented.

Relationship between $CO_2$ emission and fuel consumption rate according to used fuels at driving mode (주행모드에서 사용연료에 따른 자동차의 $CO_2$ 배출특성과 연료소비율의 상관관계 비교 분석)

  • Kim, Yong-Tae;Lee, Ho-Kil;Kang, Jeong-Ho;Han, Sung-Bin;Chung, Yon-Jong
    • Journal of Energy Engineering
    • /
    • v.17 no.4
    • /
    • pp.227-232
    • /
    • 2008
  • Carbon dioxide is considered a major greenhouse gas that contributes to global wanning. $CO_2$ is a major component of the exhaust in the combustion of any hydrocarbon fuel. The regulation for $CO_2$ emission from vehicles has become much more stringent in recent years. These more stringent regulations require vehicle manufacturers to develop alternative fuels that reduce exhaust emissions. This paper evaluated the correlation of $CO_2$ emission and fuel economy in the Gasoline, Diesel, and LPG vehicles according to FTP-75 and NEDC(ECE15+EUDC) driving mode. From this study, we discovered that the decrease rate of $CO_2$ emission is higher for fuels of lower carbon concentration. When the relationship between $CO_2$ emission and fuel consumption rate according to used fuels is expressed as a function, one can find out that they have a high correlation. LPG vehicles produce less $CO_2$ emission than gasoline and diesel vehicles.

The influence of Flame holder design on Ion voltage and CO emission (보염기 형상이 이온전압과 배기배출물에 미치는 영향)

  • Wie, Jae-Hyug;Kim, Young-Soo;Yang, Dae-Bong;Kim, Yang-Ho;Jeong, Young-Ki;Ryu, Jeong-Wan;Lim, Jae-Beom;Chang, Young-June;Jeon, Chung-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2186-2191
    • /
    • 2008
  • An experimental study was performed to investigate the effect of swirl condition and secondary air rate on the Ion voltage and CO emission characteristics. In this study, the combustion characteristics were investigated with the variation of swirler diameter, vane angle, suction air rate. The result of this study, the Ion voltage increase with increasing the diameter of the swirler. Additionally with increasing the suction air rate, the Ion voltage is the same. The CO concentration depends on suction air rate. In the other hand, it is almost unaffected by swirler's diameter. The flame length and Ion voltage decease with decreasing O2 percentage of surrounding air.

  • PDF

Environmental Effect Analysis for PV system using LCA (LCA를 이용한 태양광발전의 환경영향분석)

  • Choi, Bong-Ha;Park, Soo-Uk;Lee, Deok-Ki
    • New & Renewable Energy
    • /
    • v.3 no.2 s.10
    • /
    • pp.11-16
    • /
    • 2007
  • This paper analyses the environmental effect of 100kw PV system installed in Tibet using Life Cycle Assessment(LCA). Then, energy payback time(EPT) and life-cycle CO2 emission rate are estimated based on life-cycle of the PV system. As a result of the estimation, 6 year of EPT and 20 g-C/kWh of CO2 emission rate are obtained. In China, average CO2 emission rate of fossil fuel power generation plant is 260 g-C/kWh. This shows that PV system would be very promising for global environmental issues. For advanced LCA, we need to collect detailed and various data about raw material of PV system.

  • PDF