• Title/Summary/Keyword: %24CO_2%24 storage capacity

Search Result 18, Processing Time 0.032 seconds

Estimation of Reservoir Area and Capacity Curve Equation using UAV Photogrammetry (무인항공기 사진측량에 의한 저수면적과 저수량 곡선식 산정)

  • Lee, Geun Sang;Choi, Yun Woong;Lee, Suk Bae;Kim, Seok Gu
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.3
    • /
    • pp.93-101
    • /
    • 2016
  • Reservoir area and reservoir capacity must be evaluated for reservoir management such a water supply, water-purity control and so on. In this paper, the reservoir area and reservoir capacity according to the level of storage range of water(149~156 El.m) could be calculated by using TIN data model of study area, Gyoyeon reservoir, TIN data model was made of DSM which was created by using UAV and GCP survey. From the results of applying the various functions to reservoir area and capacity, reservoir area and reservoir capacity according to the level of storage range of water showed the highest coefficient of determination of 0.97 in fourth-order polynomial, and 0.99 in second-order polynomial, respectively. Thus, it could be expected the efficient reservoir management by estimating reservoir area and capacity curve equation through UAV photogrammetry.

Determination of an LNT Regeneration Condition Based on a NOx Storage Fraction in a 2.2L Direct Injection Diesel Engine (2.2L 디젤 엔진에서 NOx 흡장률 기반 LNT 재생 조건 결정)

  • Chun, Bongsu;Lee, Jungwoo;Han, Manbae
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.3
    • /
    • pp.345-351
    • /
    • 2016
  • This study was carried out to determine an optimal lean $NO_x$ trap (LNT) regeneration condition based on a $NO_x$ storage fraction. The LNT regeneration was performed by an in-cylinder post fuel injection method. A $NO_x$ storage fraction is defined by the ratio of current cumulated $NO_x$ amount in the LNT to the $NO_x$ storage capacity: 0 means empty and 1 fully loaded. In this study five engine operating conditions were chosen to represent the New European Driving Cycle. With various $NO_x$ storage fractions each engine operating condition, the LNT regeneration was executed and then $NO_x$ conversion efficiency, additional fuel consumption, CO and THC slip, peak catalyst temperature were measured. The results showed that there exist an optimal condition to regenerate the LNT, eg. 1500 rpm 6 bar BMEP with below 0.7 $NO_x$ storage fraction in this experimental constraint.

Economic Feasibility Study for CO2 Ocean Sequestration (CO2 해양격리시스템의 기술.경제적 가능성평가)

  • Park, Se-Hun;Oh, Wee-Yeong;Kwon, Moon-Sang
    • Ocean and Polar Research
    • /
    • v.27 no.4
    • /
    • pp.451-461
    • /
    • 2005
  • The $CO_2$ storage in geologic and oceanic reservoirs is considered to be one of the carbon management strategies for responding to global climate change. Ocean carbon sequestration is purposeful storage acceleration into the ocean of large amounts of carbon that would accumulate in the atmosphere and naturally enter the ocean over a longer timespan. Some technologies for $CO_2$ ocean sequestrations have been developed as a nation project. However, $CO_2$ ocean sequestrations are attractive because they have the advantage of vast capacity sequestration far away from industrial areas, and offer easier monitoring whereas less economic advantage has been indicated as one of the key barriers compared with $CO_2$ geosphere sequestration, which is produced as a byproduct. In this paper, a conceptual design for $CO_2$ ocean sequestration is introduced, and the preliminary examination is described. As a result, the $CO_2$ price, US$ 24/t shows far away from the economics. The causes come from the expensive $CO_2$ recovery cost and the low $CO_2$ price. The expensive $CO_2$ recovery cost is because too much electricity and water are consumed. In order to look for an economic balance point for $CO_2$ ocean sequestration, NPV=0, it is increases the $CO_2$ price. Finally 60.4$ per ton is found to be the balance price.

Comparison of Soil Characteristics and Carbon Storage between Urban and Natural Lands - Case of Chunchon - (도심지와 자연지간 토양 특성 및 탄소저장량 비교 - 춘천시를 대상으로 -)

  • Jo, Hyun-Kil;Han, Gab-Soo
    • Journal of Forest and Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.71-76
    • /
    • 1999
  • This study compared soil characteristics and carbon storage between urban and natural lands in Chunchon. Soil pH was lower in natural lands (5.0) than in urban lands (6.6), and therefore exchangeable cation was a little lower in natural lands. Organic matter and cation exchange capacity were respectively, 1.4 and 1.7 times higher in natural lands than in urban lands, while available $P_2O_5$ was about 3.2 times higher in urban lands. Organic carbon storage in soils averaged $24.8{\pm}1.6$ (standard error) t/ha in urban lands and $31.6{\pm}1.6t/ha$ in natural lands, 1.3 times greater than in urban lands. Annual carbon accumulation in soils of natural lands was 1.3 t/ha/yr (litterfall minus decomposition). The carbon storage in Chunchon' s soils equaled about 31% of annual carbon emission (245,590 t/yr).

  • PDF

Volume of Water Storage and Evapotranspiration by Inserted Materials at a Reservoir of Porous Grass Block (저수형 잔디블록 저수조 내 충진재료에 따른 저수량 및 초종별 증발산량)

  • Han, Seung-Ho;Choi, Joon-Soo;Yang, Geun-Mo;Yang, Byoung-E;Kang, Jin-Hyoung;Kim, Won-Tae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.5 s.118
    • /
    • pp.76-83
    • /
    • 2006
  • The purpose of this study was to investigate the performance of porous grass block. For the investigation, Festuca arundinacea and Zoysia japonica 'Zenith' were planted, and the volume of evapotranspiration and remains were examined based on different materials in the water tank in the experiment of Festuca arundinacea, the volume of water storage of treatment with perlite ($10.84{\iota}/m^2$) was higher than that with drainage ($7l/m^2$). The difference between the two was $3.84/m^2$. The drainage treatment without water storage capacity showed the higher degree of dryness in turf grass. The volume of evapo-transpiration of treatment with perlite was the highest (21.57mm/week). The volume of evapotranspiration of treatment with sand was 19.57mm/week, and with treatment with drainage was 18.24mm/week. Based on the measured volume of daily evapotranspiration of $2.60{\sim}3.08mm\;d^{-1}$, it was determined that the unit with water storage capacity would store water of one to two days usage compared to unite without such storage capacity. In the experiment of Zoysia japonica 'Zenith', the volume of water storage of treatment with perlite was $10.77l/m^2$ which was similar to the former experiment. The volume of evapotranspiration of treatment with perlite and sand were 21.64mm/week and 20.64mm/week, respectively. In case of airtight water tank, the volume was measured as 22.06mm/week. Each treatment has no notable difference in the volume of evapotranspiration. In conclusion, from the investigation in this study, porous grass block with water tank was found to be effective in plant growth under low irrigation. As the ecological area ratio and vegetated porous pavement have became more emphasized, additional study of rain infiltration and reservoir effect are needed in the future.

Low Temperature Storage of Rough Rice Using Cold-Air in Winter(I) - Storage Characteristics after Rough Rice Cooling - (겨울철 냉기를 이용한 벼의 저온저장(I) - 벼 냉각 후 저장특성 -)

  • Lee J. S.;Han C. S.;Ham T. M.;Yon K. S.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.3 s.110
    • /
    • pp.155-160
    • /
    • 2005
  • The objective of this research was to establish a domestically available cooling storage technique by cold-air in winter, using winter cool air ventilation fur determining rough rice cooling method in the storage and dry bin. The rough rice storage characteristics of two test conditions, winter cool-air ventilation storage and ambient temperature storage, were evaluated from January to July 2001, using a storage and dry bin of 300-ton capacity. Results of this research are as follows: Grain temperature was from $-5.1\~-8.5^{\circ}C$ after winter cool-air ventilation, and grain initial temperature for ambient temperature bin storage was $0.3\~1.9^{\circ}C$. Moisture content of rough rice decreased from $0.28\;to\;0.93\%$ and from $1.53\;to\;1.92\%$ to compare with original moisture contents for winter cool-air ventilation, and for ambient temperature bin storage, respectively. Broken ratio of brown rice from winter cool-air ventilation bin increased from $0.16\;to\; 0.92\%$, and brown rice broken ratio was from $2.24\;to\;2.86\%$ for ambient temperature bin storage to compare with initial broken ratio. Hardness of stored rice increased along storage period increase in alt storage methods, and cooling bin storage increased rice hardness of 0.271kgf: this increasing was lower then the other methods from 0.059 to 2.239kgf. Germination rates were decreased approximately 9.03, 3.14 and $3.20\%$ for upper, middle, and bottom of ventilating winter air bin, respectively, and germination rates of 2.70, 3.47 and $4.14\%$ were approximately decreased for upper, middle, and bottom parts of ambient temperature bin storage, respectively.

Surface Modification of $AB_2$ Type Hydrogen Storage Alloys by Ball Milling for Ni-MH Battery (Ni-MH 전극용 $AB_2$계 수소저장합금의 볼밀링 처리에 의한 표면개질 연구)

  • Moon, Hong-Gi;Park, Choong-Nyeon;Yoo, Joung-Hyun;Park, Chan-Jin;Choi, Jeon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.4
    • /
    • pp.418-424
    • /
    • 2006
  • In order to improve the activation properties of the $AB_2$ type hydrogen storage alloys for Ni-MH battery, the alloy surface was modified by employing high energy ball milling. The $Zr_{0.54}Ti_{0.45}V_{0.54}Ni_{0.87}Cr_{0.15}Co_{0.21}Mn_{0.24}$ alloy powder was ball milled for various period by using the high energy ball mill. As the ball milling time increased, activation of the $AB_2$ type composite powder electrodes were enhanced regardless of additives. When the ball milling time was small discharge capacities of the $AB_2$ type composite powder electrodes increased with the milling time. On the other hand for large milling time it decreased with increasing milling time. The maximum discharge capacity was obtained by ball milling for 3-4 min.

Beneficial effects of ton-bag and wire-steel pallet on postharvest handling of onion and the cost evaluation (톤백 및 와이어철제파렛트 이용에 따른 양파의 수확후관리 효율성 증대와 경제성 평가)

  • Kwon, Young-Deuk
    • Food Science and Preservation
    • /
    • v.24 no.7
    • /
    • pp.915-922
    • /
    • 2017
  • This study aimed in onion production by evaluating cost and labor efficiencies of onion storage methods using either a ton-bag or a wire-steel pallet. New methods using ton-bag and wire-steel pallets were developed and applied to postharvest tasks, such as harvest packaging, transportation, and storage. The storage parameters evaluated for their effect on the logistics of onion production were: working duration, working hours, and cost expenditure. The longitudinal tensile strength of the ton-bag developed in this study was 16% higher than that of the conventional ton-bag. The wire-steel pallet developed in this study had 10% more storage capacity in a low-temperature storage room, and its truck loading capacity was more than doubled compared to that of the conventional steel pallet. There was no difference in the wasting rate during bulk storage between the newly developed wire-steel pallet and the conventional steel pallet, for 500 kg of onions. However, the bulk storage of 1,000 kg of onions using the wire-steel pallet was not found to be suitable, because the wasting rate of onions stored using the wire-pallet was 3.7% higher than that of onions stored using a conventional steel pallet. The time and the total investing costs for the bulk method decreased by 50.1% and 46.1%, respectively, compared to those for conventional harvest. In the bulk storage using the wire-steel pallet, the total storage cost decreased by 28.8%. Thus, it is estimated that we could have saved 18.3 billion won if the wire-steel pallet method about 30% of the total onion production (1,298,749 M/T) in 2016.

Electrochemical Study of Electrode Material of Ni-MH Battery for HEV and PEMFC Fuel Cell (HEV 및 PEMFC 연료전지용 니켈수소 전지의 전극재료에 대한 전기화학적 평가)

  • Kim, Ho-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.24-28
    • /
    • 2006
  • Electrochemical hydrogenation/dehydrogenation properties were studied for a single particle of a Mm-based(Mm : misch metal) hydrogen storage alloy($MmNi_{3.55}Co_{0.75}Mn_{0.4}Al_{0.3}$) for the anode of Ni-MH batteries. A carbon fiber microelectrode was manipulated to make electrical contact with an alloy particle, and the cyclic voltammetry and the galvanostatic charge/discharge experiments were performed. A single particle of the alloy showed the discharge capacity of 280[mAh/g], the value being 90[%] of the theoretical capacity. Data were compared with that of the composite film consisting of the alloy particles and a polymer binder, which is more practical form for Ni-MH batteries. Additionally, pulverization of the alloy particles are directly observed. Compared with the conventional composite film electrodes, the single particle measurements using the microelectrode gave more detailed, true information about the hydrogen storage alloy.

Application of an electroless copper coating in alkaline bath to preparation of the metal hydride electrode (금속 수소화물 전극제조에 있어서 알카리 무전해 구리 도금법의 응용)

  • CHOI, Jeon;PARK, Choong-Nyeon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.3 no.2
    • /
    • pp.9-15
    • /
    • 1992
  • Electroless copper plating method using an alkaline bath have been employed in copper coating of the (LM)Ni4.5Co0.1MnO.2A10.2 hydrogen storage alloy powders for electrode preparation. The plating were conducted without any pretreatment of alloy powders. For the preparation of the electrodes, about 0.12g of the copper coated alloy powder (copper to alloy ratio 1/3 by weight) was compacted with pressure of 6 tons/cm2 at room temperature. The disk-type compacts had a diameter of 10mm and thickness of about 0.24mm. The electrode characteristics were examined through SEM observations and electrochemical measurements in a half cell. The electrochemical measurement showed that the maximum discharge capacity of the electrodes prepared by using alkaline bath were 245mAh per gram of coated alloy (327mAh per gram of alloy) and appeared a considerable degradation with increasing number of cycles. The decrease of the discharge capacity after 100 cycles was about 30% It can be suggested that, with a slight of improvement, this electroless copper plating method could be applied to the preparation of the rare earth-nickel based alloy electrode.

  • PDF