• Title/Summary/Keyword: %24CO_2%24 storage

Search Result 146, Processing Time 0.03 seconds

Variation of Nephrotoxicity Biomarkers by Urinary Storage Condition in Rats

  • Lee, Jung-Min;Han, Young-Hwan;Choi, Su-Jeong;Park, Ju-Seong;Jang, Jeong-Jun;Bae, Re-Ji-Na;Lee, Mi Ju;Kim, Myoung Jun;Lee, Yong-Hoon;Kim, Duyeol;Lee, Hye-Young;Park, Sun-Hee;Park, Cheol-Beom;Kang, Jin Seok;Kang, Jong-Koo
    • Toxicological Research
    • /
    • v.30 no.4
    • /
    • pp.305-309
    • /
    • 2014
  • Recently, there has been an increase in the use of several nephrotoxicity biomarkers in preclinical experiments. In addition, it has been indicated that the result may have been influenced by secondary factors, such as sample storage condition or storage period. In this study, we have assessed the variation in urinary nephrotoxicity biomarkers as a result of urine storage conditions and storage period of the urine. Urine was sampled from specific pathogen-free Sprague-Dawley rats (19 weeks old), which were housed individually in hanged stainless steel wire mesh cages. Urine was stored at $20^{\circ}C$, at $4^{\circ}C$, or at $-70^{\circ}C$ after sampling. The levels of the biomarkers such as beta-2 microglobulin (B2M), cystatin-C (Cys-C), N-acetyl-${\beta}$-D-glucosaminidase (NAG), micro albumin (MA), micro protein (MP) were measured at 6, 24, 48 and 144 hr after sampling. The B2M level was significantly decreased at 6, 24, 48, and 144 hr compared to 0 hr at $-70^{\circ}C$ (p < 0.05, p < 0.01, p < 0.05, and p < 0.05, respectively) and 24 and 144 hr at $20^{\circ}C$ (p < 0.01, p < 0.01, respectively). The Cys-C level was significantly decreased at 144 hr compared to 0 hr at $4^{\circ}C$ (p < 0.01), at $20^{\circ}C$ (p < 0.05) and at $70^{\circ}C$ (p < 0.01). MP and MA levels were not different for 144 hr in all storage conditions. Taken together, B2M and Cys-C levels were modulated by storage temperature and period. For the enhancement of test accuracy, it is suggested that strict protocols be established for samples to minimize the effects of the storage conditions on the detected levels of biomarkers.

Quality Changes of 'Yeobong' Strawberry with CA Storage Conditions (CA저장조건에 따른 '여봉' 딸기의 품질변화)

  • Kim, Ji-Gang;Hong, Seong-Sik;Jeong, Seok-Tae;Kim, Young-Bae;Jang, Hyun-Sae
    • Korean Journal of Food Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.871-876
    • /
    • 1998
  • 'Yeobong' strawberries were stored at $2^{\circ}C$ under controlled atmosphere (CA) containing the combinations of $O_2{\;}(3.8%)$ and $CO_2{\;}(10,{\;}15,{\;}20%)$ and air as control. Atmospheres of $3%{\;}O_2+15%{\;}CO_2$ and $8%{\;}O_2+15%{\;}CO_2$ reduced respiration and ethylene production rates. Fruits kept under CA conditions of 10% and 15% $CO_2$ were harder than those stored under 20% $CO_2$ and air. The CA conditions of 10% or 15% $CO_2$ maintained approximately 80% of vitamin C for 24 days. Redness were increased and then decreased, but the changing trends were not clear among the storage conditions. Anthocyanin contents in $3%{\;}O_2+15%{\;}CO_2$ and $8%{\;}O_2+15%{\;}CO_2$ were slightly increased for 16 days and then decreased thereafter, while anthocyanin content in air was rapidly increased for 8 days. After 16 days of storage, off-flavor were perceived in all CA storage. And strawberries stored in 20% $CO_2$ conditions were unacceptable after 20 days. The 20% $CO_2$ significantly affected off-flavor of strawberries, but there was no significant difference between 10% $CO_2$ and 15% $CO_2$ conditions. Ethanol which is in relation to off-flavor was higher with elevated $CO_2$ levels. Although CA conditions under $3%{\;}O_2+15%{\;}CO_2$ was effective in delaying the quality changes, there was high ethanol content compared to $8%{\;}O_2+15%{\;}CO_2$ condition. Strawberry kept under $8%{\;}O_2+15%{\;}CO_2$ was maintained the shelf-life for 24 days and the condition prolonged more $4{\sim}8$ days and 12 days than the other CA conditions and air, resectively.

  • PDF

Detection of Potential Flow Paths of Leaked CO2 from Underground Storage Using Electrical Resistivity Survey (전기비저항탐사 방법에 의한 지중 저장 이산화탄소 누출 가능 경로 탐지)

  • Lim, Woo-Ri;Hamm, Se-Yeong;Hwang, Hak-Soo;Kim, Sung-Wook;Jeon, Hang-Tak
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.69-79
    • /
    • 2018
  • The Korean government attempts to reduce $CO_2$ emissions by 37% to 314.7 Mt $CO_2$, down from the estimated 850.6 Mt $CO_2$ until 2030 in order to confront green house effect. In this context, in 2014, Korean government launched $CO_2$ Storage Environmental Management Research (K-COSEM) Center for carrying out pilot-scale research on $CO_2$ leakage from underground $CO_2$ storage facilities. For the detection of $CO_2$ leakage, it is necessary to identify hydrologeological and geophysical characteristics of the subject area. In the study site of Naesan-ri, Daeso-myeon, Eumseong-gun, Chungbuk Province, two times injection tests (June 28-July 24, 2017 and August 07-September 11, 2017) of $CO_2$ and $SF_6$ dissolved waters, respectively, was conducted to understand the leakage behavior of $CO_2$ from underground. The injection well was drilled to a depth of 24 m with a 21-m casing and screen interval of 21~24 m depth. Two times resistivity surveys on August 18, 2017 and September 1, 2017, were conducted for revealing the flow of the injected water as well as the electrical properties of the study site. The study results have shown that the high-resistivity zone and the low-resistivity zone are clearly contrasted with each other and the flow direction of the injected water is similar to natural groundwater flow. Besides, the low resistivity zone is widely formed from the depth of injection to the shallow topsoil, indicating that the weathered zone of high permeability has high $CO_2$ leakage potential.

Seismic Imaging of Ocean-bottom Seismic Data for Finding a Carbon Capture and Storage Site: Two-dimensional Reverse-time Migration of Ocean-bottom Seismic Data Acquired in the Pohang Basin, South Korea (이산화탄소 지중저장 부지 선정을 위한 해저면 탄성파 탐사자료의 영상화: 포항 영일만 해저면 탐사자료의 2차원 역시간 구조보정)

  • Park, Sea-Eun;Li, Xiangyue;Kim, Byoung Yeop;Oh, Ju-Won;Min, Dong-Joo;Kim, Hyoung-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.3
    • /
    • pp.78-88
    • /
    • 2021
  • Owing to the abnormal weather conditions due to global warming, carbon capture and storage (CCS) technology has attracted global attention as a countermeasure to reduce CO2 emissions. In the Pohang CCS demonstration project in South Korea, 100 tons of CO2 were successfully injected into the subsurface CO2 storage in early 2017. However, after the 2017 Pohang earthquake, the Pohang CCS demonstration project was suspended due to an increase in social concerns about the safety of the CCS project. In this study, to reconfirm the structural suitability of the CO2 storage site in the Pohang Basin, we employed seismic imaging based on reverse-time migration (RTM) to analyze small-scale ocean-bottom seismic data, which have not been utilized in previous studies. Compared with seismic images using marine streamer data, the continuity of subsurface layers in the RTM image using the ocean-bottom seismic data is improved. Based on the obtained subsurface image, we discuss the structural suitability of the Pohang CO2 storage site.

Effect of $CO_{2}$ Gas Packaging on the Shelf-life of Refrigerated Pork Cuts (탄산가스 포장에 의한 신선돈육의 저장성향상에 관한 연구)

  • Kim, Yong-Su;Kim, Yun-Ji;Yoo, Ick-Jong
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.246-249
    • /
    • 1994
  • Shelf-life of pork packaged under $CO_{2}$ was observed and the optimal volume of $CO_{2}$ gas was determined. High gas barrier film, EVOH($CO_{2}$ permiability; 1 $cc/cm^{2}{\cdot}24\;h{\cdot}atm$) was used as packaging material and the volume ratios of sample to $CO_{2}$ of 1 : 1, 1 : 3 and 1 : 5 were tried using the control of vacuum packaged pork. To ev.3luate quality of pork cuts, total plate counts, TBA, color and sensory score were monitored during the storage at $4{\pm}1^{\circ}C$ for 31 days. TPC of vacuum packaged pork increased up to $4.6{\times}10^{6}\;CFU/cm^{2}$ in 24 days while that of $CO_{2}$ gas packaged pork $4.5{\times}10^{5}\;CFU/cm^{2}$ at the same storage period, and it took 7 days more for gas packaged pork to reach the same TPC count. There was no significant difference in TBA value between vacuum packaged and gas packaged pork. In the color L and a values were not affected by treatment but vacuum packaged pork cuts showed higher b value than gas packaged pork. According to sensory evaluation, gas packaged pork showed less off flavor, better flavor and freshness than vacuum packaged one (P<0.05).

  • PDF

Numerical study of CO2 hydrate dissolution rates in the ocean: Effect of pressure, temperature, and salinity

  • Kyung, Daeseung;Ji, Sukwon;Lee, Woojin
    • Advances in environmental research
    • /
    • v.4 no.1
    • /
    • pp.17-24
    • /
    • 2015
  • In this study, we numerically investigated the effect of pressure (100-250 bar), temperature (274-288 K), and salinity (3.5% w/w electrolytes) on $CO_2$ hydrate dissolution rates in the ocean. Mass transfer equations and $CO_2$ solubility data were used to estimate the $CO_2$ hydrate dissolution rates. The higher pressure and lower temperature significantly reduced the $CO_2$ hydrate dissolution rates due to the increase of $CO_2$ particle density. In the high salinity condition, the rates of $CO_2$ hydrate dissolution were decreased compared to pure water control. This is due to decrease of $CO_2$ solubility in surrounding water, thus reducing the mass transfer of $CO_2$ from the hydrate particle to $CO_2$ under-saturated water. The results obtained from this study could provide fundamental knowledge to slow down or prevent the $CO_2$ hydrate dissolution for long-term stable $CO_2$ storage in the ocean as a form of $CO_2$ hydrate.

Changes of carbon-13 Isotope of Dissolved Inorganic Carbon Within Low-pH CO2-rich Water during CO2 Degassing (pH가 낮은 탄산수의 CO2 탈기에 따른 용존탄소동위원소 변화)

  • Chae, Gitak;Yu, Soonyoung;Kim, Chan Yeong;Park, Jinyoung;Bang, Haeun;Lee, Inhye;Koh, Dong-Chan;Shinn, Young Jae;Oh, Jinman
    • Journal of Soil and Groundwater Environment
    • /
    • v.24 no.3
    • /
    • pp.24-35
    • /
    • 2019
  • It is known that ${\delta}^{13}C_{DIC}$ (carbon-13 isotope of dissolved inorganic carbonate (DIC) ions) of water increases when dissolved $CO_2$ degases. However, ${\delta}^{13}C_{DIC}$ could decrease when the pH of water is lower than 5.5 at the early stage of degassing. Laboratory experiments were performed to observe the changes of ${\delta}^{13}C_{DIC}$ as $CO_2$ degassed from three different artificial $CO_2$-rich waters (ACWs) in which the initial pH was 4.9, 5.4, and 6.4, respectively. The pH, alkalinity and ${\delta}^{13}C_{DIC}$ were measured until 240 hours after degassing began and those data were compared with kinetic isotope fractionation calculations. Furthermore, same experiment was conducted with the natural $CO_2$-rich water (pH 4.9) from Daepyeong, Sejong City. As a result of experiments, we could observe the decrease of DIC and increase of pH as the degassing progressed. ACW with an initial pH of 6.4, ${\delta}^{13}C_{DIC}$ kept increasing but, in cases where the initial pH was lower than 5.5, ${\delta}^{13}C_{DIC}$ decreased until 6 hours. After 6 hours ${\delta}^{13}C_{DIC}$ increased within all cases because the $CO_2$ degassing caused pH increase and subsequently the ratio of $HCO_3{^-}$ in solution. In the early stage of $CO_2$ degassing, the laboratory measurements were well matched with the calculations, but after about 48 hours, the experiment results were deviated from the calculations, probably due to the equilibrium interaction with the atmosphere and precipitation of carbonates. The result of this study may be not applicable to all natural environments because the pressure and $CO_2$ concentration in headspace of reaction vessels was not maintained constant as well as the temperature. Nevertheless, this study provides fundamental knowledge on the ${\delta}^{13}C_{DIC}$ evolution during $CO_2$ degassing, and therefore it can be utilized in the studies about carbonated water with low pH and the monitoring of geologic carbon sequestration.

Quality Changes of Nabak Kimchi During Storage with Different Levels of Fermentation (발효 조건과 저장기간에 따른 나박김치의 특성 변화)

  • Lim, Su-Youn;Lee, Hye-Ran;Lee, Jong-Mee
    • Journal of the Korean Society of Food Culture
    • /
    • v.20 no.4
    • /
    • pp.468-475
    • /
    • 2005
  • To determine the effect of different fermentation level on the quality of Nabak Kimchi during storage, this study was carried by analysing the result of physico-chemical properties, microbiological characteristics and sensory evaluation of Nabak Kimchi stored up to 24 days. For the physico-chemical properties, pH, total acidity, reducing sugar, carbon dioxide contents, color values were investigated while for the microbiological characteristics, total microbial counts and lactic acid bacteria were studied. Nabak Kimchi products were fermented at six different level of temperature and time and stored in Kimchi refrigerator at $4^{\circ}C$ for 24 days. As the storage period increased, the pH values of LF15, SF25 and LF25 decreased rapidly after initial fermentation and the pH values of SF4, LF4 and SF15 increased slightly in the beginning and then decreased. total acidity increased as storage period proceeded. the amount of reducing sugar was 4.92mg/ml before fermentation and increased significantly and reached its maximum values then decreased. lightness and redness of Nabak Kimchi decreased as storage period became longer, but yellow of Nabak Kimchi increased during storage. Total microbial counts of SF25 and LF25 reached to the highest at the 6th day and total microbial counts of LF15 reached to the highest at the 12th day and then significantly decreased. However, total microbial counts of SF4, LF4 and SF15 continuously increased up to the 24th day. The number of lactic acid bacteria was similar to the phase of the change of total microbial counts.

Evaluation of Short-Term CO2 Passive Sampler for Monitoring Atmospheric CO2 Levels

  • Yim, Bongbeen;Sim, Yoon-Ah;Kim, Sun-Tae
    • Journal of Climate Change Research
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • In this study, we investigated the applicability of a short-term carbon dioxide ($CO_2$) passive sampler using turbidity change in a solution containing barium hydroxide ($Ba(OH)_2$). The mass of $CO_2$ introduced into the $Ba(OH)_2$ aqueous solution was strongly correlated ($r^2=0.9565$) to the change in turbidity caused by its reaction with the solution. The sampling rates calculated for 1 h and 24 h were $42.4{\pm}5.4mL\;min^{-1}$ and $2.3{\pm}0.3mL\;min^{-1}$, respectively. Both unexposed (blank) and exposed samplers remained stable during the storage period of at least two weeks. The detection limits of the passive sampler for $CO_2$ were 81.5 ppm for 1 h and 61.5 ppm for 24 h. Based on the results, the passive sampler using the change of turbidity in the $Ba(OH)_2$ aqueous solution appears to be a suitable tool for measuring short-term atmospheric concentrations of $CO_2$.

Rapid Cooling Performance Evaluation of a ZrCo bed for a Hydrogen Isotope Storage (수소동위원소 저장용 ZrCo용기의 급속 냉각 성능 평가)

  • Lee, Jungmin;Park, Jongchul;Koo, Daeseo;Chung, Dongyou;Yun, Sei-Hun;paek, Seungwoo;Chung, Hongsuk
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.2
    • /
    • pp.128-135
    • /
    • 2013
  • The nuclear fuel cycle plant is composed of various subsystems such as a fuel storage and delivery system (SDS), a tokamak exhaust processing system, a hydrogen isotope separation system, and a tritium plant analytical system. Korea is sharing in the construction of the International Thermonuclear Experimental Reactor (ITER) fuel cycle plant with the EU, Japan, and the US, and is responsible for the development and supply of the SDS. Hydrogen isotopes are the main fuel for nuclear fusion reactors. Metal hydrides offer a safe and convenient method for hydrogen isotope storage. The storage of hydrogen isotopes is carried out by absorption and desorption in a metal hydride bed. These reactions require heat removal and supply respectively. Accordingly, the rapid storage and delivery of hydrogen isotopes are enabled by a rapid cooling and heating of the metal hydride bed. In this study, we designed and manufactured a vertical-type hydrogen isotope storage bed, which is used to enhance the cooling performance. We present the experimental details of the cooling performances of the bed using various cooling parameters. We also present the modeling results to estimate the heat transport phenomena. We compared the cooling performance of the bed by testing different cooling modes, such as an isolation mode, a natural convection mode, and an outer jacket helium circulation mode. We found that helium circulation mode is the most effective which was confirmed in our model calculations. Thus we can expect a more efficient bed design by employing a forced helium circulation method for new beds.